Loading...
HomeMy WebLinkAboutTRO4103373.2z z 0 ti y � � o a � L 0 C' I� U HCL c 'B U \ c a c o "'1 cV 4 II cng� 44 z @�5 z (V n j00 2 ff � I 2 99 L I 21 ff ILI to r 2" (TrP) UL LISTED PER STANDARD 0508 SUITABLE FOR USE AS SERVICE M;MRANG EQUIPf� MEETS EUSERC/PSE SPEC. 0.188 WALL BRACKET ALUM. ALLOY 6063-T6 1 /2" BNC LOCKBOLT GR. 18-8 S.S. FLUSH JOINT 4-1/2" O.D. — TAPERED ALUM. POLE 0.188 WALL ALLOY 6063-T6 SATIN GROUND FINISH -- 151 HANDHOLE. 4"x6" OPENING W/COVER AND S.S. SCREWS BASE FLANGE ALLOY 356-T6 WITH BOLT COVERS & S.S. SCREWS 12017AD VAC 2ff . - 4,-2" 99 1601 COMPONENT SCHEC)UL METERBASE: 100 AMP, 4 JAW, AW 1"114T8, 5AFETY !�,')CKET TYPE, 5TH JAW AT 9:00 POSITION (CONTRACTOR TO VERIFY WITH SERVING UTILITY PANELBOARD: 120/240 VAC, 100 AMP, 1 PHASE, 3 WIRE, COPPER BU5 i WESTINGHOUSE BAB BOLT -ON BREAKERS: J 1-100/2 MAIN i 2-20/2 ILLUMINATION BRANCH 1-50/1 SIGNAL BRANCH 1-15A CONTROL CKT BRANCH 1-20/1 GROUND FAULT RECEPTACLE BRANCH CONTACTOR: LIGHTING RATED, 30 AMP, 4 POLE, 1s0 VAC COIL, SQ D'►891GDPA34VO2UI. aTERMINAL BLOCK TO REMOTE PHOTO ELECTRIC CELL. OPHOTO -CELL 5YPA55 5WITCH, 5P5T, 15 AMP; 211 VAC. OGROUND FAULT RECEPTACLE, 120 VAC, DUPLEX, 2.0A CA51NET-NEMA 3R, PADMOUNT, "12 GA PREGAI VANIZED STEEL CONSTRUCTION, 2 SCREENED AND GA,5KETED VENTS DOORS: I-1EAvY DUTY CONCEALED HINGES (LIFT-OFF TYPE) STAINLESS STEEL VAULT HANDLES, PADLOCKABLE METER DOOR 5E6T CX LOCK ON DISTRIBUTION DOOR P0I5HED WIRE GLA55 WINDOW IN METER DOOR CLOSED CELL NEOPRENE GASKET, CARD HOLDER FINISH: POLYESTER POWDER COAT, ALUM NUM OUTSIDE, WHITE INSIDE SERVICE CABINET FOR STREET CONTROL & TRAFFIC SIGNAL \ Y ADOPTED 0 CITY OF RENTON STANDARD PLANS N O� LST DATE: 06/25/03 DWG. NAME: JR— SP PAGE: SIZE AS REQUIRED 4-1 /2" „ O.D. 2 N.PS. " SLIPFI TTER 5 -9 RADIUS --�� f--11-1/4" SQ. 11" TO 12" DIA. BOLT CIRCLE 4 1/2" OF BOLT ABOVE 4" CONCRETE PAD FINISHED GRADE (4) 1" BNC GALV. STEEL ANCHOR BOLTS WITH NUTS AND WASHERS 9.P d d 4,) 2` TYPICAL DESIGN `B' JUNCTION BOX Vet 1rH F&G9 TT T=- I =► i JIB�\�lC� (OP, 5LAMt-*"rR_) SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS 4" CONCRETE PAD , #8 BARE COPPER GROUND WIRE 2 - LIGHTING SYSTEM WIRES TO CONTACTOR (SIZED AS REQ'D.) 5/8"x8' COPPER CLAD GROUND ROD STANDARD 25 FOOT DAVIT POLE Y p ADOPTED CITY OF RENTON + d STANDARD PLANS IN O� LST DATE: 10/30/96 DWG. NAME: JR-01 SP PAGE: J002 FUSE KITS QUICK DISCONNEC' 10 AMP IN LINE FUSE KITS S.E.C. OR EQUAL - GROUND LUG 2" MIN. GROUT UNDER POLE BASE 5„ tip GROUND CLAMP PVC CONDUIT SYSTEM TO LUMINAIRE 1 /4" MINIMUM DRAIN HOLE - I 49 I I I I II i II II I( L� �J I i 3' SQ. OR DIA. yam" J. J,q"I!, P� of WAS,y� 20734 lU� /FGISTE�E�G\�� OVAL E EXPIRES: 3 f 1 j2006� NO. TYP. CONC. PAD I I �- I U w i-- - - - — - - - - - - - R/W LINE SIDEWALK CURB G ROADWAY CURB SIDEWALK R/W LINE 10' MIN, CLEARANCE FROM DRIVEWAY ALTERNATE PLAN VIEW H 25' 30 35' 40' SL 18'-3" 23'-3' 28'-3' 33'-3' T 0.188 0.188 1 0.219 0.219 TAPERED ALUM. POLE 'T' WALL ALLOY 6063-T6 SATIN GROUND FINISH HANDHOLE 4"x6" OPENING �W/COVER & S.S. SCREWS GROUND LUG INSIDE POLE INSIDE POLE 'H' 2' TO 4' OVERHANG STREET LIGHT CONDUIT--J TRENCH DEPTH 24" ALTERNATE STREET CROSS SECTION 2' TO 4' 1'-2»-� OVERHANG 3'-6" H FACE OF CURB TO SL' R I W CENTER OF POLE ,ROADWAY SIDEWAL7 Ir I ��I` T O PLANTER STRIP STREET LIGHT CONDUIT TRENCH DEPTH 24" TYPICAL STREET LIGHT FOUNDATION LOCATION 12 96 REFORMAT TO 11"x17" DCV DIRT 11 92 TYP. STREET LIGHT FDN, LOCATION IBCA DATE REVISION I BY APPR'D LIGHT BASE AND JUNCTION BOX LOCATIONS y ADOPTED / CITY OF RENTON 4; f STANDARD PLANS N O LST DATE: 12/96 DWG. NAME: JR-35 SP PAGE: J014- LIGHTING STANDARD JUNCTION BOX 7' o — ®ov D ov ° ov Ca ooi� ®° v, 4/ p b \ v ov �b / e®� o v \ n 4 o A®� D I I ® °> \ o ' D° O O e b oI 1— � I vD D = e o 3 I I p O O 4 0 p p ° D 4" DEEP pd dvD ° D b ° I vo TOP OF CONCRETE FOUNDATION TO o a °/ -' I v p BE LEVEL WITH TOP OF SIDEWALK o�� b° OR CURB. D 10 ov��� - \\i/\\\�`�` STREET LIGHT POLE �-JUNCTION BOX ° °Q \V PLAN VIEW \ \\% �dO � : SIDE VIEW \ � _TUwcTioN i3Ox �_ID REQUIRES N ` FOG 7 TF_" OK slnntu�R NI�f'aD INDIVIDUAL JUNCTION �� X HOLE LC (' K I KI & D E.\11�=E_ TCD 13. E- ° NOTE: o �✓ D o Db a o v D CLASS `B' CONCRETE TO BE USED _ II,� U ��C RIa`IG TH� L_1L) ° b v IN CONSTRUCTION OF PAD 3 ''� z" toiG FIN N,� S��I�y ® z b e o = DeD Cat - S 4 _j o O p n 0 v v TYPICAL LIGHTING UNDERGROUND SYSTEM \CY p ADOPTED PLAN VIEWow 1' C1 T CITY OF RENTON STANDARD PLANS CONCRETE PAD DETAILS LST DATE: 12/96 Y C ADOPTED n CITY OF RENTON DWG. NAME: JR-06 SP PAGE: J007 STANDARD PLANS & O LST DATE: 10/30/96 DATE REVISION BY APPR' DWG. NAME: JR-07 SP PAGE: J008 ENGINEER: T4w337 FSD :Ta. c r t�TTE i 3/2 �° 7 REVISION BY I APPR. I DATE JAEGER ENGINEERING 9419 South 204th Place Ken t, WA. 98031 Phone No. (253) 85 0— 0934 Fax No. (253) 850-- 0155 RECOMMENDED FOR APRID!/AL BBY.J ���R��� �;%�x�: � � DATE. BY. ram._/t+,r�' DATE. BY, DATE.• BY.' DATE: CI®T"Y OF Rm1*-7''T®1%.-T DEPARTMENT OF PUBLIC WORKS STREET LIGHTING DETAILS WEBBER SHORT ,FLAT DESIGNED: JJJ DATE: 12/10/05 FILE NAME: DRAWN: JJJ CHECKED: JJJ SCALE: NONE FIELD BOOK: PAGE: APPROVED: DIRECTOR OF PUBiJC WORKS SHEET: 1 OF: 11 C.A.T-W702 ' 3Aw)' It