HomeMy WebLinkAboutTRO4103735.2N
O
LO
O
O
CM
T
*k
N
Y
M
Q
z
O
Cn
J_
'6
v
Q
CL
z
0
C%)
J
NOTEI
EXISTING UTILITY L❑CATI❑NS SHOWN HEREON ARE
APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND
H❑RIZONTAL L❑CATI❑N OF ALL EXISTING UNDERGROUND
UTILIITES PRI❑R TO C❑MMENCING C❑NSTRUCTION, NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES
ARE SHOWN HERE❑N, THE ENGINEER ASSUMES NO
RESP❑NSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES
NOT SHOWN IN THEIR PROPER LOCATION,
CALL BEFORE YOU DIG: 1-800-424-5555
POWER SOURCE
FROM PSE, COORDINATE
AT TIME OF POWER APPLICATION
LABEL BACK SIDE OF NEW SERVICE CABINET WITH
ADDRESS PER STANDARD PLAN #122.1.
CONDUIT AND WIRING S CHED UL E
RUN NO.
CONDUI T
WIRING
Z�
2" PVC SCH. 40
3- #8 T H. W. COPPER
ZL
2 " P VC SCH. 80
3- #8 T H. W. COPPER
CONSTRUCTION NOTES
1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN
ACCORDANCE WITH THE CITY OF RENTON DESIGN STANDARDS
AND SPECIFICATION. THE APPROPRIATE STATE ELECTRICAL
CODES AND THE PROVISIONS OF THE LATEST EDITION OF THE
IES LIGHTING HANDBOOK
2. ALL WORK ON THE LIGHTING SYSTEM SHALL BE COMPLETED
BY LICENSED CONTRACTORS EXPERIENCED IN THE INSTALLATION
OF ILLUMINATION SYSTEMS.
3. THE CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS
AND COORDINATE INSPECTION WITH THE CITY, STATE AND
POWER COMPANY AS REQUIRED.
4. CONTRACTOR SHALL CONTACT CITY INSPECTOR A MINIMUM LP#1
OF 24-HOURS PRIOR TO COMMENCING WORK ON THE LIGHTING
SYSTEM.
5. CONTRACTOR SHALL CONTACT PUGET SOUND ENERGY (PSE) _
FOR POWER DESIGN. "
6. CONTRACTOR TO COORDINTE WITH PUGET SOUND ENERGY
PSE) CONSTRUCTION SERVICES FOR SERVICE CABINET ELECTRIC
HOOKUP. THE POINT OF SERVICE FROM PSE SHALL BE A
MAXIMUM OF 50 FEET FROM THE PROPOSED SERVICE CABINI ... -
IF GREATER A HANDHOLE IS REQUIRED. LABEL BACK SOUTH 55th ST'REE
OF SERVICE CABINET WITH ADDRESS, (SEE STD. PLAN #123.1).
7. INSTALL TYPE 1 JUNCTION BOX W/ CONCRETE PAD
ON NORTH SIDE OF NEW SERVICE CABINET.
OFFE ENGINEERS
13932 SOUTHEAST 159TH PLACE
RENTON, WASHINGTON 98058
PHONE: 425-260-3412
CONTACT: DARRELL OFFE, P.E.
f
o ti e�
z:
o
27460 e
oFFss ONALR�'��\
5/13/2014
M
\i
1219
REVISION
T=373501
GRAPHIC SCALE
0 15 30 60
1 inch = 30 feet
ILLUMINATION POLE SCHEDULE
POLE NO.
STREET
POLE
STATION
OFFSET
MOUNT
VOLTAGE
WATTAGE/
LUMINAIRE
TYPE
BASE
COMMENTS
ID NO.
HEIGHT
TYPE
DISTRIBUTION
LP#1
MORRIS AVE. SO.
10+27.5
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#2
MORRIS AVE. S0.
11+00.0
19.5'
RT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#3
MORRIS AVE. S0.
11+52.0
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#4
MORRIS AVE. S0.
12+08.0
19.5'
RT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP 5
#
MORRIS AVE. SO.
12+64.8
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP # 6
MORRis AVE. So.
13+25.0
19.5'
RT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP 7
#
S0. 53rd PLACE
13+65.0
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP # 8
S0. 53rd PLACE
14+54.0
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#9
SO. 53rd PLACE
15+58.0
19.5'
LT.
14'
240
44
LED
CY17TA
PRESTIGE -VS3AR-3L-44W-4K
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#10
S0. 53rd PLACE
16+68.0
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#1 1
SMITHERS PL. S.
21 +07.0
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#12
SMITHERS PL. S.
20+07.0
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#13
SMITHERS PL. S.
22+00.0
19.5'
LT.
14'
240
44
LED
CY17TA-VS3AR-3L-44W-4K
PRESTIGE
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
CRAMER NW
DESIGNED:
D.L. OFFE, P.E.
DRAWN:
D.L. OFFE, P.E.
CHECKED:
BY DATE AP P R 11 APPROVED:
VERTrA- NAVD 1988
SCALE HORIZONTAL- NAD 19W/1991
ONE INCH DATU M
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CITY OF
RENTON
Planning/Building/Public Works Dept.
Checked for Compliance to City Standards
6 f /6//V
WILSON PARK & WILSON PARK 2
ROBERT WILSON
720 SOUTH 55th STREET
STREET LIGHTING PLAN
10/2/2013
PAGE
DRAWING NO:
L-1
SHEET-
12 OF. 14
IN7
CDV