No preview available
HomeMy WebLinkAboutTED4003736.3w J a LL Z LaiLL z a C F_ it I I I I X L.LJ F- F- 0 M I Q) 0 V V) M N �i 0 N rn E v 0 0 d I rn 0 I N Li) i a� a� c a� i LV L0 cn 0 0 0 Ln oe ui 7 ' 0 01 -7--i .+wVc Ian a.. 'r4 'KAS. C.O.R. ISO TO 1�1 NE 4TH STREET BEET SAWCUT LINE p z 0 (TYP.) a: 0 LLJ .;; m."..VAULT ACCESS ul ! I .—_ — — /1 — _ — — — — — — — — — III Z / if Iuj 1 "R �.� 1 2 RFINISHED GRADE a o a ,A sa d a d 734" EXPANSION JOINT AT 20' INTERVALS CEMENT CONCRETE BARER CURB NOT TO SCALE S-8' o N � P N 1'-8" -I V-4" N (2) COATS TRAFFIC LINE YELLOW 1-06 10 NOTE: 1. PROVIDE YELLOW PAINTED DIRECTIONAL ARROW AT ALL LOCATIONS INDICATED ON SITE AND ARCHITECTURAL PLANS. 2. PROVIDE DIRECTIONAL VARIATIONS OF THESE ARROWS AS INDICATED ON SITE PLAN. N-SIT E DIRECTIONAL ARROWS NOT TO SCALE ATS YELLOW M R-313603 343�CAMERA ".. \ I ,,,_NEW RAMP. SEE SHEET C12. PIED PUSH BUTTON aHEE i F TRAFFIC I j SING/STRIPING Ple II 9 CONDUIT TRENCH HATER' `I METER I( 24 16 URB AND GUTTER 1 DRIVEWAY r—— — — — — —- I I -_-- I I : II I I I' I I I , I I I II I E z NOTE: ALL SIGNS UNDER SEPARATE PERMIT. OA NEW LOGO AND "QFC" TEXT. SEE SHEET A2.0 FOR DETAILS. © NEW ILLUMINATED LOGO SYMBOL. SEE SHEET A2.0 FOR DETAILS. © NEW KIOSK LOGO SIGN. SEE SHEET A2.0 FOR DETAILS. �D NEW PRICE SIGN. SEE SHEET A2.0 FOR DETAILS. CITY OF RENTON Approved by: A Date: /y Approved by: I Date: Approved by: Approved by: Date: Date: T 1 "=20' A" .,,.". END -`ROPOSED ASPHALT PAVEMENT PROPOSED CONCRETE PAVEMENT SAWCUT ------------------ EXISTING CONCRETE CURB ------------------------- NEW CONCRETE CURB NEW CONC. SWALE - - - -- CONSTRUCTION CALL OUTS Ol 84'x4O' PUMP ISLAND CANOPY WITH 5 MPD's AND ISLANDS. SEE CANOPY AND ARCHITECTURAL PLANS FOR CANOPY DETAILS. SEE TANK AND ELECTRICAL PLANS FOR PIPING AND LIGHTING EXTENSIONS. ® REINFORCED CONCRETE DRIVE SLAB BENEATH PUMP ISLAND CANOPY. SEE SHEET A2 FOR CONTROL JOINTS AND SPECIFICATIONS. (1) 10,000/8,r !` '-ON 7 MPARTMENT AND (1) 20,000 GALLON UNDERGROUNDS : €E S ANKS PER TANK PLANS. 4REINFORCED CONCRETE SLAL VE UNDERGROUND GASOLINE STORAGE TANKS. SEE TANK PLANS FOR DETAILS. ® PREFABRICATED KIOSK ENCLOSURE WITH RESTROOM. SEE ARCHITECTURAL PLAN Al FOR KIOSK FOUNDATION AND EQUIPMENT DETAILS. © INST` 6" CONCRETE BARRIER CURB PER DETAIL 1/C3. O ASP T PAVEMENT SECTION PER DETAIL 5/C7. ® h TAPE PLANTER. CONTRACTOR SHALL PROVIDE TOPSOIL TO TOP OF NEW CURB. SEE PE AND IRRIGATION PLANS FOR PLANTING AND IRRIGATION DETAILS. ® INST - (1) SELF SERVE AIR WATER UNIT MOUNTED ON 4'-0" x 4'-0" x 6" CONCRETE MOUNTING PAD. RUN (1) 3/4" CONDUIT TO KIOSK FOR POWER. SEE DETAIL, SHEET A3. 10 STORAGE TANK VENT STACK PER TANK DRAWINGS. REFER TO DETAIL 6/C7 FOR VENT SLAB AND BOLLARD DETAIL. 11 PERIMETER CONCRETE GUTTER SWALE PER DETAIL 8/C7. 1© BOLLARD PER DETAIL 4, SHEET A3. 13 PROVIDE (2) 3/4" CAPPED CONDUITS FROM KIOSK TO VENT RISER SUPPORT STRUCTURE (FOR POTENTIAL FUTURE VAPOR RECOVERY SYSTEM MODIFICATIONS). 14 INTEGRAL CONCRETE GUTTER SWALE PER DETAIL 9/C7. 15 CONCRETE SIDEWALK PER CITY OF RENTON DETAIL F005 16 CONCRETE CURB AND GUTTER PER CITY OF RENTON DETAIL F001 1© TYPE 3 CEMENT CONCRETE DRIVEWAY ENTRANCE PER CITY OF RENTON DETAIL F004 18 INSTALL 3" CONDUIT WITH 4#4/0 KCMIL THHN/THWN CU AND 1 #2 GROUND TO KIOSK FOR POWER SERVICE. 1 g NEW POWER CONDUIT, SERVICE, AND HANDHOLE BY PSE, PER SEPARATE PSE WORK ORDER. G.C. SHALL COORDINATE INSTALLATION WITH PSE. ©0 "RIGHT -TURN ONLY" SIGN ON STEEL 2"X2" POST AND HARDWARE. 21 COVERED TRASH ENCLOSURE, SEE ARCHITECTURAL PLANS FOR DETAILS. ® SAWCUT PAVEMENT IN SMOOTH, CONTINUOUS LINE FOR NEW WORK. COORDINATE LIMITS WITH DEMOLITION AND IRRIGATION PLANS. 18" IMPORTED SAND/COMPOST BLEND HAVING 8 TO t,� ORY LANDSCAPE PLANS FOR PLANTING DETAILS. SEE S14EET 4" WIDE YELLOW PAINTED PARKING STALLS WITH 4" WIDE PAINTED STRIPES AT 45' DEGRLES AND 2' O.C. WHERE SHOWN. INSTALL (2) 3/4-INCH CONDUIT FROM KIOSK TO PLANTER FOR NEW MONUMENT SIGN POWER AND COMMUNICATIONS. (SIGN AND FOOTING BY OTHERS, SEPARATE PERMIT). COORDINATE EXACT CONDUIT ROUTING AND SIGN PLACEMENT WITH KROGER PROJECT MANAGER SEE ELECTRICAL PLAN FOR WIRING. 6 CONNECT TO EXISTING TRANSFORMER FOR NEW POWER SERVICE. NEW DOMESTIC AND IRRIGATION METERS. REFER TO SHEET C6. ELECTRICAL METER AND MAIN DISCONNECT Q ©g INSTALL APPROVED 3/4" DCVA, IN PROTECTIVE ENCLOSURE, ON WATER SERVICE ADJACENT TO AIR/WATER UNIT. SEE UTILITY PLAN C6. a0 MANUAL TRANSFER SWITCH Q (3 1 (NOT USED) INSTALL CONDUIT FROM KIOSK TO PUMP STATION FOR POWER AND TELEMETRY. SIZE(S) TO BE DETERMINED WITH PUMP STATION DESIGN. TYPE 1A SIDEWALK RAMP PER CITY OF RENTON STD DETAIL F010 ® TYPE 2A SIDEWALK RAMP PER CITY OF RENTON STD DETAIL F011 3�5 NEW CONCRETE PEDESTRIAN PLAZA W/SEAT WALL. SEE LANDSCAPE PLAN L1 FOR LAYOUT AND DETAILS. ® CONCRETE RETAINING WALL. SEE LANDSCAPE PLAN AND STRUCTURAL PLANS FOR DETAILS. SEE GRADING PLAN (C4) FOR ELEVATIONS. PROVIDE WRAPPED, 6" PERFORATED FOOTING DRAIN WITH CONNECTION TO STORM. RETAINING WALLS OVER 4' HIGH REQUIRE A SEPARATE BUILDING PERMIT. (NOT USED) NEW LUMINAIRE AND FOUNDATION. REFER TO PLANS PREPARED BY TENW. 6J CONDUIT TRENCH. REFER TO PLANS PREPARED BY TENW. PATCH PAVEMENT PER CITY STANDARDS. 40 NEW SIGNAL POLE AND FOUNDATION. REFER TO SEPARATE SIGNAL PLANS PREPARED BY TENW. 41 TRAFFIC SIGNAL ',7" _ER AND SERVICE CABINETS. REFER TO SEPARATE TRAFFIC SIGNAL PLANS PREPARED -<, ILNW. �_`J PEDESTRIAN PUSH BUTTON (TYPICAL). REFER TO TRAFFIC SIGNAL PLANS PREPARED BY TENW. 4 NEW VIDEO DETECTION CAMERA. REFER TO TRAFFIC SIGNAL PLANS PREPARED BY TENW. 44 ON -SITE PAINTED DIRECTION W PER DETAIL 2/C3. 455 (NOT USED) ® INSTALL 3/4" POWER SERVICE CI UIT FROM KIOSK TO BOLLARD(S). COORDINATE EXACT ROUTING IN FIELD. SEE LANDSCAPE PLAN FOR BOLLARD LOCATION/DETAILS AND ELECTRICAL PLAN FOR WIRING DETAILS. 4� INSTALL 2" PHONE SERVICE CONDUIT FROM KIOSK TO STREET FOR NEW PHONE SERVICE. COORDINATE WITH PHONE COMPANY FOR EXACT ROUTING, WIRING, AND CONNECTION TO EXISTING SERVICE. N n a �GM^(V 4 n U O _ t r7hG E N G \N*- 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)2-'` P782 FAX CIVIL F- Nc.._ '_AND PLANNING, SIfliV Y, ATAL SERVICES 0 3 Q ra Z Q L XT \ }, 3 O p o L. a rs, O ao 3 W ,�° �i3u tL e3>U�oa+0 QOrO Q CsaOUo I CL ; mJs 4L. �' C4 W) t N� c Cn Cv r- < -.N O Cr Li x� � Z O Ln W IY tiy`9� 11 o v� z 285' ff9eCIS TER��\��`�' ION A L ENG M M 7 N N N N i? 0 N '1�a �'1� CCV a `� ` t , n 4 cn 0 0� �IYI�I0IIn0a! Q ~ � h= m t= m W N aa CV qh � J Z O m G C= N 1+ n W a R' cr m W a � Q U W y�,� W W W a m® a a m m ZN rn v Ln n Project N: 15432 Store #00871 15432- 03- A. dwg Address: 4615 NE 4TH STREET RENTON, WA WE ffmVeds4 T PLAN QF-c FIJEL.NMG FAM" Drawing No.: C3 of 13 Cl TY OF QFC FUELING FACILITY Permit No. U 13000883 `�`°B°°R' RENTON POW: IQ Planning/Building/Public Works Dept. WWI: OF: cD.TZ-41—ININININJAIA. ro z .p On 1 z C�i