No preview available
HomeMy WebLinkAboutTRO4103736.3w Q z U w O 0r a- a z W J IL F- �'F7 VJ U7 1 lL 0- 0- W LL z 0 F_ z Lu U LL 0 SIGNAL & ILLUMINATION WIRING SCHEDULE (AFFECTED RUNS ONLY) RACEWAY CONDUIT SIZE VEH. DETECT. 2C(SH) NEW PPB 2C(SH) NEW E. V. DETECT. 3C(SH) NEW VEH. HEAD 5C NEW CONT. PWR #6 NEW PED. HEAD 5C NEW INTC. NEW VIDEO DETECT. CABLE NEW SERVICE PWR #2 NEW ILLUM #g NEW EQUIP. GRND. NEW PULL WIRE NEW CONDUIT FILL NEW ALLOW. FILL (NEW) ALLOW. FILL (EXIST.) NO. 1 1.5" EXIST. 2 1 0.30 --- 0.83 2 1.5" EXIST. 3 1 0.36 --- 0.83 3 1.5" EXIST. 1 0.18 --- 0.83 4 1.5" EXIST. * 2 1 2 1 0.82 --- 0.83 2" SPARE 1 --- 0.87 1.36 2" EXIST. * 3 2 1 2 1 1.01 --- 1.36 5 2" SPARE 1 --- 0.87 1.36 2" EXIST. * 1 2 2 2 1 0.93 --- 1.36 6 1.5" EXIST. * 1 --- --- 0.83 2" SPARE 1 --- 0.87 1.36 3" EXIST. * 5 4 2 3 1 4 1 1 1 1 2.18 --- 3.00 7 1.5" EXIST. * 2 1 --- --- 0.83 2" SPARE 1 --- 0.87 1.36 2" EXIST. * 1 2 2 1 1 0.79 --- 1.36 8 1.5" EXIST. * 1 --- --- 0.83 2" SPARE 1 --- 0.87 1.36 2" EXIST. * 1 2 2 2 1 1 1.08 --- 1.36 9 1.5" EXIST. * 2 1 --- --- 0.83 2" SPARE 1 --- 0.87 1.36 10 2" SCH40 PVC 1 1 0.15 0.87 --- 11 2" SCH40 PVC 1 2 1 1 1 1 0.65 0.87 --- 2" SPARE 1 --- 0.87 --- 12 2" SCH40 PVC 2 1 0.11 0.87 --- 3" SCH40 PVC 5 5 3 4 1 1.86 1.95 --- 13 3" SCH40 PVC 2 2 4 3 4 1 2 1 1.86 1.95 14 2" SCH40 PVC * 2 1 0.17 0.87 --- 15 2" SCH40 PVC 2 1 0.15 0.87 --- 16 3" SCH80 PVC 3 1 040 1.95 --- 17 2" SCH40 PVC 1 1 1 0.37 0.87 --- 18 3" SCH40 PVC * 1 2 2 2 1 1 0.97 1.95 19 3" SCH80 * 5 4 2 3 4 1 1 1 1 1 2.07 1.95 --- " UIHLK LXIJIINU O;UNUUC;IUKS1FIdLK MAY Fit F'KLJLNI WIRING NOTES 1. ALL CONDUITS CONTAINING COPPER CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WIRE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN #8 AWG OR AS NOTED OTHERWISE IN THE WIRE NOTES). CONDUITS THAT DO NOT CONTAIN ELECTRICAL CONDUCTORS SHALL INCLUDE A DETACHABLE PULL TAPE. SPARE/EMPTY CONDUIT SHALL BE LABELED "CITY OF RENTON" AND SHALL CONTAIN DETECTABLE PULL TAPE. 2. ALL CONDUIT SHALL BE PVC SCH 40, EXCEPT UNDER ROADWAY USE PVC SCHEDULE 80 CONDUIT. ILLUMINATION WIRING DIAGRAM EX. -� NE 4TH STREET 1 EX. EX. EX. NEW SERVICE Z ILLUM A ; ILLUM B Q J J EX.0 NOT TO SCALE 0 SERVICE BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P-100 AMP --- SIGNAL 1 P-60 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B 2P-20 AMP 30 AMP ILLUM C (SPARE) 2P-20 AMP 30 AMP SEE STD PLAN 122.2 FOR ADDITIONAL REQUIREMENTS SEC 15, TWP 23N, RGE 5E, W.M. CONSTRUCTION NOTES TARGET CALCULATION SUMMARY ACTUAL DESIGN CRITERIA CALCULATION UNIFORMITY AREA AVG. MAINTAINED G TFC FOOT CANDLES A MIN. F INTERSECTION 4.00: 1 NE 4TH ST & DUVALL AVE NE1.32 3.04 gl. 4.00: 1 NE 4TH STREET 1.51 3.78 0.90 4.00: 1 DUVALL AVE NE 0.74 3.70 PEDESTRIAN PUSHBUTTON OFFSET DETAIL PEDESTRIAN APS PUSH BUTTON STATION. ORIENTATION SHALL BE TYPE PPB OR DETERMINED BY THE ENGINEER IN TYPE PS POLE THE FIELD. POLARA ' MIN TOP OF CEMENT 10" CONCRETE PEDESTRIAN MAX 00 CURB OR CEMENT CONCRETE PEDESTRIAN 2 ISLAND N TYPE PPB OR TYPE `t PS POLE FOUNDATION TOP OF CEMENT CONCRETE RAMP TYPE 2 OR CEMENT CONCRETE PEDESTRIAN PATHWAY NA P PER CITY OF T FOUNDATION T 4. FURNISH N INSTALL BLACK POWDER COATED FINISH TYPE 111 SIGNAL POLE 1 CONSTRUCT U DATION PER POLE SCHEDULE SHEET S O FURN S AND I S RENTON STANDARDS WITH 28 FT MAST ARM FOR SOUTHBOUND TRAFFIC. INSTALL NEW TWO VEHICULAR SIGNAL HEADS AND ONE VANTAGE VECTOR VIDEO DETECTION CAMERA AND MOUNT. RELOCATE EXISTING PREEMPTION DETECTORS AND SIGNS TO NEW MAST ARM. INSTALL ONE POLARA NAVIGATOR APS PEDESTRIAN PUSHBUTTON ASSEMBLY, ONE PEDESTRIAN SIGNAL HEAD 24 AND ONE TERMINAL CABINET ON SIGNAL POLE. INSTALL ONE 135W80LED4K-ES LUMEC DOMUS 55 SERIES LED LUMINAIRE WITH PHOTOCELL PER THE LUMINAIRE POLE SCHEDULE SHEET TS-02. O2 CONSTRUCT FOUNDATION AND INSTALL LUMINAIRE POLE WITH 135W80LED4K-ES LUMEC OOMUS 55 SERIES LED LUMINAIRE, PHOTOCELL AND ONE 6OW30LED4K-EO LUMEC DOMUS SMALL SERIES LUMINAIRE PER THE LUMINAIRE POLE SCHEDULE, SHEET TS-02 AND CITY OF RENTON STD PLAN 1 17. 1. OCONSTRUCT COMBINATION TRAFFIC SIGNAL CONTROLLER/SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD PLAN 122.2 AND 126.2. CONTRACTOR SHALL FURNISH AND INSTALL NEW TS2-TYPE 1, P PLUS CONTROLLER CABINET (WITH BBS) ON NEW FOUNDATION. THE CABINET DOOR SHALL OPEN TO THE SOUTHWEST. CITY WILL PROVIDE TRAFFIC SIGNAL CONTROLLER AND COMPONENTS AND PERFORM ALL REQUIRED TESTING OF CONTROLLER EQUIPMENT. CONTRACTOR SHALL FURNISH ALL VIDEO DETECTION BOARDS/EQUIPMENT. INSTALL SERVICE CABINET WITH 1201240V SINGLE PHASE POWER PER CITY OF RENTON SPECIAL PROVISIONS. PROVIDE A 60 AMP SIGNAL CIRCUIT BREAKER, THREE 15 AMP ILLUMINATION CIRCUIT BREAKERS, AND OTHER CIRCUIT BREAKERS/COMPONENTS. THE CONTRACTOR SHALL CONFIRM CABINET AND JUNCTION BOX LOCATIONS/LAYOUT WITH THE CITY PRIOR TO INSTALLATION. CITY REQUIRES 30 DAYS FOR TESTING. DELIVER AND PICKUP SIGNAL CABINET TO CITY SIGNAL SHOP FOR TESTING. OREMOVE EXISTING TIMBER LUMINAIRE POLE. CONSTRUCT FOUNDATION AND INSTALL NEW LUMINAIRE POLE WITH 135W80LED4K-ES LUMEC DOMUS 55 SERIES LED LUMINAIRE, PHOTOCELL AND ONE 60W30LED4K-ED LUMEC DOMUS SMALL SERIES LUMINAIRE PER THE LUMINAIRE POLE SCHEDULE SHEET TS-02 AND CITY OF RENTON STD PLAN 117.1. OSIGNAL POLE TO BE DISPOSED OF BY THE CONTRACTOR. RELOCATE EXISTING PREEMPTION DETECTORS AND SIGNS TO NEW MASTARM SIGNAL POLE. REMOVE EXISTING FOUNDATION TO A MINIMUM OF 24" BELOW GRADE. FILL AND COMPACT VOID. O EXISTING OVERHEAD TRAFFIC SIGNAL POWER AND CONDUCTORS LINE TO BE REMOVED BY PSE. COORDINATE WITH PSE. O7 INSTALL ONE VANTAGE VECTOR VIDEO DETECTION CAMERA AND MOUNT ON EXISTING SIGNAL POLE MAST ARM PER CITY OF RENTON SPECIAL PROVISIONS. O8 INTERCEPT EXISTING ILLUMINATION CONDUIT AND EXTEND TO NEW JUNCTION BOX. OINTERCEPT EXISTING SIGNAL CONDUIT AND EXTEND TO NEW JUNCTION BOX. 10 CONTRACTOR SHALL FURNISH AND INSTALL 10' RISER ON EXISTING POWER POLE AND ALL CONDUIT AND CONDUCTORS. CONTRACTOR SHALL LEAVE SUFFICIENT SLACK IN CONDUCTORS FOR FINAL POWER CONNECTION BY PSE. CONTRACTOR SHALL COORDINATE WITH PSE TO MAKE THE FINAL CONNECTION TO THE POWER SOURCE, INCLUDING COMPLETING/SUBMITTING ALL FORMS AND PROVIDING ALL FEES. CONTRACTOR SHALL PROVIDE PSE WITH 4 DAYS NOTICE PRIOR FINAL CONNECTION. 11 COORDINATE TRENCHING LIMITS WITH ASPHALT RESTORATION, TYP. 12 CONSTRUCT FOUNDATION AND INSTALL TYPE PPB POST WITH ONE PEDESTRIAN PUSHBUTTON PER CITY OF RENTON STANDARDS AND WSDOT STANDARD PLAN J-20. 10. 13 CONSTRUCT FOUNDATION PER POLE SCHEDULE, SHEET TS-04. FURNISH AND INSTALL TYPE PS POLE WITH ONE POLARA NAVIGATOR APS PEDESTRIAN PUSHBUTTON ASSEMBLY AND ONE PEDESTRIAN SIGNAL HEAD 33 PER CITY OF RENTON STANDARDS AND WSDOT STANDARD PLAN J-21.10. PEDESTRIAN SIGNAL HEAD SHALL BE TYPE 'D' TOP MOUNTED PER WSDOT STANDARD PLAN J-20.16. 14 REMOVE EXISTING PPB 34. CAP REMAINING HOLE PER CITY APPROVED METHOD. 15 REMOVE EXISTING PPB 23. CAP REMAINING HOLE PER CITY APPROVED METHOD. 16 EXISTING LUMINAIRE AND POLE TO REMAIN. 17 REMOVE EXISTING SERVICE CABINET, CONTROLLER CABINET AND FOUNDATION. EXISTING EQUIPMENT SHALL REMAIN IN OPERATION UNTIL THE NEW SERVICE CABINET AND CONTROLLER ARE FULLY OPERATIONAL. PROTECT EQUIPMENT DURING CONSTRUCTION ACTIVITY. RETURN SALVAGED EQUIPMENT TO THE CITY OF RENTON. 18 REMOVE EXISTING JUNCTION BOX. FILL AND COMPACT VOIDS. 19 VIDEO DETECTION ZONE SHALL BE INSTALLED AS SHOWN. 20 REMOVE EXISTING JUNCTION BOX, CONDUIT BENDS, AND LOOP CONDUCTORS BACK TO THE CONTROLLER. FILL AND COMPACT VOIDS. 21 REMOVE EXISTING LOOP CONDUCTORS BACK TO CONTROLLER. 22 PULL EXISTING FIBER OPTIC CABLE FROM EXISTING CONTROLLER CABINET BACK TO EXISTING JUNCTION BOX. ROUTE EXISTING FIBER OPTIC CABLE TO NEW CONTROLLER CABINET. CONTRACTOR SHALL PERFORM FIBER OPTIC CABLE TERMINATION WITH CITY TRANSPORTATION MAINTENANCE DEPARTMENT SUPERVISOR ERIC CUTSHALL AT (425) 430-7423, AS NECESSARY. SIGNAL & ILLUMINATION GENERAL NOTES 1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE LOCATED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE ENGINEER. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE PROJECT SPECIAL PROVISIONS, CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS. J. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR WITH TRANSPORTATION MAINTENANCE DEPARTMENT SUPERVISOR ERIC CUTSHALL AT (425) 430-7423, AS NECESSARY. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 7. POLE FOUNDATIONS SHALL BE EXCAVATED AND POURED FOLLOWING POLE LOCATIONS APPROVAL BY THE ENGINEER. 8. THE CONTRACTOR SHALL CONFIRM THAT 10 FEET MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED BETWEEN LUMINAIRE POLES AND OVERHEAD POWER LINES. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDA INSTALLATION. 9. NO SPLICES WILL BE ALLOWED IN FIELD WIRING. T=373603 10. CITY SIGNAL SHOP WILL DO FINAL INSPECTION, FLASH OUT SIGNAL CABINET AND PROVIDE FINAL TURN -ON AFTER FINAL INSPECTION. ILLUMINATION POLE SCHEDULE PED. LIGHT PED. LIGHT PED. LIGHT PED. LIGHT LUM. POLE * MOUNT. ARM SERVICE/ WATTAGE LUMINAIRE TYPE - MOUNT. ARM WATTAGE LUMINAIRE TYPE - POLE POLE NO. ID NO. STREET STATION OFFSET HEIGHT VOLTAGE LENGTH CIRCUIT TYPE DISTRIBUTION HEIGHT LENGTH TYPE DISTRIBUTION TYPE BASE COMMENT 135W80LED4K-ES FLAT LENS METAL 1 DUVALL AVE SEE SHEET TS-04 240 ILLUM B 135 LED DUMUS 55 SERIES, TYPE 111 -- ROUND NEW SIGNAL POLE LUMINAIRE. A NE 4 ST 3+22.0 40.0' RT 35' 240 n J,�' ILLUM A 135 LED 135W80LED4K-ES FLAT LENS 14' 4' 60 LED 60W30LED4K-ES FLAT LENS METAL FIXED NEW POLE/FDN PER RENTON STD. PLAN 117.1. DUMUS 55 SERIES, TYPE III DUMUS SMALL SERIES, TYPE III ROUND O NE 4 ST 4+ 13.5 36.5' RT 35' 240 IZ�y4' ILLUM A 135 LED 135W80LED4K-ES FLAT LENS 14' 4' 60 LED 60W30LED4K-ES FLAT LENS METAL FIXED NEW POLE/FDN PER RENTON STD. PLAN 117.1. DUMUS 55 SERIES, TYPE Ill DUMUS SMALL SERIES, TYPE 111 ROUND OC DUVALL AVE EX EX EX 240 EX ILLUM A EX EX -- -- -- -- EX EX EXISTING LUMINAIRE AND POLE TO REMAIN. * POLE ID NO. WILL BE DETERMINED AT TIME OF CONSTRUCTION. CITY OF RENTON APPROVED BY: !? _ _ DATE: ffv�t�l APPROVED BY: DATE: _ 7 �12a& APPROVED BY: DATE: _________ APPROVED BY: ________________ DATE: QZ J 0 2 O Z W a: d T11 r9 U W LL U a I - a N0 t o c 0 Ea 0 0 Z C n O v m.2^=8 Z. om'O (Du� d!-pUp wry w s ` U �.01 � N N O v , C N � �.. �wo�(U o C - O � ol�p ua ) cg:C L pg� a Qa N c og oo� a^ 0 v 3 o s d v � T � � 41 �v f 4, mo 13 () a L o u x: .o LL y In o, O S¢C W O 00 N z�u �`0a'� D2 0Rmu aQ o U - =rn )N000 S.-QC4(V N� U104 01 O 04 Of OO.. Y��vo o-tox �000= 1- n n n ~ o 0 � � N ON \ UJ 00 0 m N �e C m U 0 CC O p F- m � Y O 0 F 0 N N U of Q i Q Q _J Q m m z ro 0 cn cn o z w w w of of 0 I- F- F- L) V) Q Of of LLI a- m m Q_ a Q zI- INI - I -I� Project #: 15432 Store #00871 Address: 4615 NE 4TH STREET RENTON, WA QFC FUELING FACILITY Drawing No.: 2 of 6 SURVEYED: SCALE: 1988 DATE' HORIZONTAL- WD983/1991 �/ �QFC _.>6; { .201 4 DESIGNED:TDR CITY �� Permit NoFUELING U13000883 Y FlELDBOOK: DRAWN: ML RENTON PAGE: TDR ONE INCH DRAWING NO: CHECKED: �AT FULL SCALE SCALE DATUM Planning/Building/Public Works Dept. TRAFFIC SIGNAL & ILLUMINATION PLAN TS-02 EMH IF NOT ONE INCH N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY SHEET: OF: CTB -NNNNAA