Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TRO4103738.5
ILLUMINATION POLE SCHEDULE LUM. POLE NO. POLE ID ** NUMBER STREET STATION * OFFSET LATITUDE LONGITUDE MOUNT. VOLTAGE SERVICE/ WATTAGE LUMINAIRE TYPE - BASE COMMENT HEIGHT CIRCUIT ITYPE DISTRIBUTION OCY17T4-VS3AR-3L-44W-4K ROAD A 27+58.0 14.5' LT N047.26'02.29" W 122.10'42.48" 14' 240 ILLUM A 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. O ROAD A 26+66.5 16.2' RT N047.26'02.51 " W 122* 10'41.14" 14' 240 ILLUM A 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. OROAD A 25+72.0 CY17T4-VS3AR-3L-44W-4K PRESTIGE 16.2' RT N047.26'02.50" W122.10'39.76" 14' 240 ILLUM A 44 LED FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K O ROAD A 24+93.5 13.5' LT N047'26'02.18" W 122.10'38.67" 14' 240 ILLUM A 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 51 ROAD A 24+ 1 1.5 19.5' RT N047-26'01.90" W 122.10'37.47" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 1 16. 1. CY17T4-VS3AR-3L-44W-4K OROAD A 23+29.0 13.5' LT N047.26'01.02" W 122.10'37.39" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K O7 ROAD A 22+37.5 19.5' RT N047.26'00.24" W 122* 10'36.51 " 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K OROAD A 21 +53.0 13.5' LT N047.25'59.38" W 122.10'36.89" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K O ROAD A 20+71.5 19.5' RT N047.25'58.60" W122.10'36.33" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 10 ROAD A 19+80.5 13.5' LT N047.25'57.68" W 122.10'36.72" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 1 1 ROAD A 18+89.5 19.5' RT N047.25'56.81 " W 122.10'36.15" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY 17T4- VS3AR-3L-44W-4K 12 ROAD A 18+02.0 13.5' LT N047.25'55.91 " W 122.10'36.52" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY1 7T4- VS3AR-3L-44W-4K 13 ROAD A 17+05.5 19.5' RT N047.25'55.18" W 122.10'35.55" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 14 ROAD A 16+ 17.0 17.5' RT N047.2554.62" W 122' 10'34.71 " 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 15 ROAD A 15+45.5 19.5' LT N047.25'53.93" W 122.10'34.12" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 16 ROAD A 14+62.5 14.5' RT N047.2553.61 " W 122.10'32.90" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 17 ROAD A 13+89.5 14.5' RT N047.25'52.85" W 122' 10'32.74" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 18 ROAD A 13+02.5 14.5' RT N047.25'51.99" W122.10'32.76" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 19 ROAD A 12+ 14.0 19.5' LT N047.25'51.10" W 122* 10'33.15 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 1 16. 1. CY17T4-VS3AR-3L-44W-4K QROAD A 1 1 +25.0 14.5' RT N047.25'50.24" W 122.10'32.61 " 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 21 ROAD B 53+ 16.5 13.5' LT N047.25'53.95" W122* 10'35.68" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K ©2 ROAD B 52+27.0 19.5' RT N047.25'53.03" W122.10'35.96" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY1 7T4- VS3AR-3L-44W-4K QROAD B 51 +36.0 13.5' LT N047.25'52.47" W 122.10'37.08" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K �4 ROAD B 50+55.5 19.5' RT N047.25'51.72" W122.10'37.72" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K ©5 ROAD C 60+90.0 13.5' LT N047.25'49.86" W 122.10'38.61 " 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K ^6 ROAD C 61 +56.5 28.5' RT N047.25'50.51 " W 122.10'37.98" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K ©7 ROAD C 62+29.5 13.5' LT N047.25'51.21 " W 122.10'38.63" 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K Q ROAD C 63+09.0 19.5' RT N047.25'52.06" W 122.10'38.50" 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K �9 ROAD C 63+80.0 13.5' LT N047'25'52.51 " W 122.10'39.44" 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K Q ROAD C 64+60.5 19.5' RT N047.25'53.35" W 122.10'39.70" 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K 31 ROAD C 65+64.5 13.5' LT N047.25'54.15" W 122.10'40.73" 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K ©2 ROAD C 66+39.5 31.5' RT N047'25'54.91 " W 122.10'40.17" 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K ©3 ROAD C 67+04.0 16.5' LT N047.25'55.55" W 122.10'40.85" 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K Q ROAD C 67+57.0 19.5' RT N047.25'56.07" W 122.10'40.31 " 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K ©5 ROAD D 70+35.5 19.5' RT N047.25'55.14" W 122.10'41.78" 14' 240 ILLUM C 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K f H f iviv.3/ Ur r or 13 A►Ct ArrrfCUAIMA i L. UU►V 1 KAG I UK JHALL (:UM IKM AVJU51 MLN►S WII H ENGINEER PRIOR TO IMPLEMENTING. POLES WITHIN PLANTER STRIP SHALL BE A MINIMUM OF 3.5' FROM FACE OF CURB TO CENTER OF POLE PER CITY OF RENTON STANDARD PLAN 124. ** POLE ID NUMBERING TO BE PROVIDED BY CITY AT TIME OF CONSTRUCTION TO BE PROVIDED AND INSTALLED BY CONTRACTOR. SERVICE 1 BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P-100 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B 2P-20 AMP 30 AMP ILLUM C 2P-20 AMP 30 AMP NOT TO SCALE GENERAL NOTES ILLUMINATION WIRING DIAGRAM 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR. 10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL AT THE EARLIEST POSSIBLE DATE. 11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT 1S POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 12. INSTALL FOUNDATION AND ELECTRICAL CABINET AT ROAD A STATION 16+27.0, 19.0' RT. LABEL CABINET USE CITY STANDARD DETAILS 119, 122.1 AND 126.1. 13. COORDINATE WITH PUGET SOUND ENERGY (PSE) FOR NEAREST ELECTRICAL POINT OF SERVICE. ROUTE SERVICE ENTRANCE CONDUIT AND CONDUCTORS TO POINT OF SERVICE PER PSE REQUIREMENTS. COORDINATE WITH CITY OF RENTON TRANSPORTATION MAINTENANCE ASSISTANT MANAGER ERIC CUTSHALL AT 425-430-7423 FOR SERVICE CONNECTION. T=373805 IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY: Gam-•- - Date: BY: Date: BY. Date: BY: Date: C o >W Qo OCO Q Z Q3 0 fN - > m = o r"t o VJ _ QO CO W N W(1) U w o 0 O I U m0 .- - U o CL +- V) LI-I 0 s <„ CL �o to � a� Ln These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited. Z O r z Q U ISSUED 00 �n = r LW Z 0 Z LLI L.L 0 F- U 10 CONSTRUCTION RELEASE SET A2 ADDENDUM #1 SEPTEMBER 16, 2014 M&H NO 4270600-132332.01 DATE April 2, 2015 DESIGNED BY TDR DRAWN BY TDR CHECKED BY: EMH DO NOT SCALE DRAWINGS SHEET CONTENTS ILLUMMINATION NOTES 41 SHEET NO ' L5 OF 6 o-4 C 0 z 7� L 'o C a g M n- co Jz m M c D N a c� o - vl _ j rn 00 I D m 0 mop �o aE m