HomeMy WebLinkAboutTRO4103739.1A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SECTION 15, TOWNSHIP 23 N., RANGE 5 EAST, W.M., CITY OF RENTON, WASHINGTON
NOTE:
Q
J
n
O
z
0
z
W
CONSTRUCTION NOTES
1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN
ACCORDANCE WITH THE CITY OF RENTON DESIGN STANDARDS
AND SPECIFICATION. THE APPROPRIATE STATE ELECTRICAL
CODES AND THE PROVISIONS OF THE LATEST EDITION OF THE
IES LIGHTING HANDBOOK
2. ALL WORK ON THE LIGHTING SYSTEM SHALL BE COMPLETED
BY LICENSED CONTRACTORS EXPERIENCED IN THE INSTALLATION
OF ILLUMINATION SYSTEMS.
3. THE CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS
AND COORDINATE INSPECTION WITH THE CITY, STATE AND
POWER COMPANY AS REQUIRED.
4. CONTRACTOR SHALL CONTACT CITY INSPECTOR A MINIMUM
OF 24—HOURS PRIOR TO COMMENCING WORK ON THE LIGHTING
SYSTEM.
5. CONTRACTOR SHALL CONTACT PUGET SOUND ENERGY (PSE)
FOR POWER DESIGN.
6. CONTRACTOR TO COORDINATE WITH ERIC CATSHALL, COR TRANSPORTATION
MAINTENANCE ASSIST. MAGR, 425-430-7423 FOR SERVICE CABINET ELECTRIC
HOOKUP. THE POINT OF SERVICE FROM PSE SHALL BE A
MAXIMUM OF 50 FEET FROM THE PROPOSED SERVICE CABINET.
IF GREATER A HANDHOLE IS REQUIRED. LABEL BACK
OF SERVICE CABINET WITH ADDRESS, (SEE STD. PLAN #123.1).
7. INSTALL TYPE 1 JUNCTION BOX W/ CONCRETE PAD
ON NORTH SIDE OF NEW SERVICE CABINET.
POLE ID. NUMBER TO BE ADDED
AT TIME OF CONSTRUCTION
POWER SOURCE
FROM PSE, COORDINATE
AT TIME OF POWER APPLICATION
LABEL BACK SIDE OF NEW SERVICE CABINET WITH
1
0
LP 5 STA. 20+43.55, NILE AVENUE NE
2....�.. I STA. 30+00.00, . NE 2nd COURT
ILLUMINATION POLE SCHEDULE
POLE NO.
STREET
POLE
STATION
OFFSET
MOUNT
VOLTAGE
WATTAGE/
LUMINAIRE TYPE
BASE
COMMENTS
ID NO.
HEIGHT
TYPE
DISTRIBUTION
LP # 1
NE
2nd
COURT
30+44.0
17.0 '
LT.
14'
240
44 LED
PRESTIGE
CY17TA—VS3AR-3L-44W-4K
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#2
NE
2nd
COURT
30+93.0
17.0'
RT.
14'
240
44 LED
PRESTIGE
CY17TA-VS3AR-3L-44W-4K
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP#3
NE
2nd
COURT
31 +50.0
17.0'
LT.
14'
240
44 LED
PRESTIGE
CY17TA-VS3AR-3L-44W-4K
FIXED
NEW
POLE
PER
STD.
PLAN
#1 16.1
LP#4
NE
2nd
COURT
32+16.0
17.0
RT.
14
240
44 LED
PRESTIGE
CY17TA—VS3AR-3L-44W-4K
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP 5
#
NE
2nd
COURT
32+50.0
17.0'
RT.
14'
240
44 LED
PRESTIGE
CY17TA—VS3AR-3L-44W-4K
FIXED
NEW
POLE
PER
STD.
PLAN
#116.1
LP # 6
NILE AVE. NE
20+87.66
17.0 '
RT.
35'
240
94 LED
ATBO 40BLEDE70 MVOLT
700 mA DRIVER
R3 NL
FIXED
NEW
POLE
PER
STD.
PLAN
#115
OFFE ENGINEERS
13932 SOUTHEAST 159TH PLACE
RENTON, WASHINGTON 98058
PHONE: 425-260-3412
CONTACT: DARRELL OFFE, P.E.
z 2
27460 e
Q)ST
1
O�FsS/NALR�`�G\
09 /22 /2014 NO.
RELOCATED LP#6 DUE TO EX. UTIL
ADDED ILLUMINAIRE AT ENTRY
REVISION
SURVEYED:
SURVEYED
DESIGNED:
D.L. OFFE, P.E.
DLO 09/19/14 DRAWN:
D.L. OFFE, P.E.
DLO 08/11/14 CHECKED:
BY DATE APPR 1 AP'ROvm:
SCALE
EXISTING UTILITY LOCATI❑NS SHOWN HEREON ARE
APPR❑XIMATE ONLY. IT SHALL BE THE CONTRACTOR'S
RESP❑NSIBILITY TO DETERMINE THE EXACT VERTICAL AND
H❑RIZ❑NTAL L❑CATI❑N OF ALL EXISTING UNDERGROUND
UTILIITES PRI❑R TO C❑MMENCING C❑NSTRUCTI❑N. NO
REPRESENTATI❑N IS MADE THAT ALL EXISTING UTILITIES
ARE SHOWN HEREON, THE ENGINEER ASSUMES NO
RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES
NOT SHOWN IN THEIR PROPER LOCATI❑N.
CALL BEFORE YOU DIG: 811
ENLARGEMENT OF INTERSECTION
SCALE: 1 "=10"
R=3 73 923
STREET LIGHTING SYSTEM TO BE INSTALLED T=373904
UNDER A SEPERATE ELECTRICAL PERMIT
USE SCHEDULE 40 PVC UNDER SIDEWALKS, 4 T=37390
USE SCHEDULE 80 PVC UNDER PAVED AREAS.
CONDUIT AND WIRING SCHEDULE
RUN NO.
CONDUIT
WIRING
2 " P VC SCH. 40
3— #8 T H. W. COPPER
F1
2" P VC SCH. 80
3— #8 T H. W. COPPER
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL. NAVD 19M
HORIZONTAL: NAD 1983/1991
DATUM
- CITY OF
RENTON
Planning/Building/Public Works Dept.
GRAPHIC SCALE
0 15 30 60
1 inch = 30 feet
Checked for Compliance to City Standards
RENTON 7 SHORT PLAT
JAYMARC HOMES, LLC
STREET LIGHTING PLAN
NE 2nd COURT / NILE AVENUE NE
09/22/2014
PAGE:
L-1
EET. 13 OF: 15
IN7
C
2
rn
� m m
N
co
Z
m
z
m
M
m
O
A
n
O
z
G)
Z
a)
M
M
Z
0
fi - '39saio y