Loading...
HomeMy WebLinkAboutTRO4103739.1A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SECTION 15, TOWNSHIP 23 N., RANGE 5 EAST, W.M., CITY OF RENTON, WASHINGTON NOTE: Q J n O z 0 z W CONSTRUCTION NOTES 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON DESIGN STANDARDS AND SPECIFICATION. THE APPROPRIATE STATE ELECTRICAL CODES AND THE PROVISIONS OF THE LATEST EDITION OF THE IES LIGHTING HANDBOOK 2. ALL WORK ON THE LIGHTING SYSTEM SHALL BE COMPLETED BY LICENSED CONTRACTORS EXPERIENCED IN THE INSTALLATION OF ILLUMINATION SYSTEMS. 3. THE CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND COORDINATE INSPECTION WITH THE CITY, STATE AND POWER COMPANY AS REQUIRED. 4. CONTRACTOR SHALL CONTACT CITY INSPECTOR A MINIMUM OF 24—HOURS PRIOR TO COMMENCING WORK ON THE LIGHTING SYSTEM. 5. CONTRACTOR SHALL CONTACT PUGET SOUND ENERGY (PSE) FOR POWER DESIGN. 6. CONTRACTOR TO COORDINATE WITH ERIC CATSHALL, COR TRANSPORTATION MAINTENANCE ASSIST. MAGR, 425-430-7423 FOR SERVICE CABINET ELECTRIC HOOKUP. THE POINT OF SERVICE FROM PSE SHALL BE A MAXIMUM OF 50 FEET FROM THE PROPOSED SERVICE CABINET. IF GREATER A HANDHOLE IS REQUIRED. LABEL BACK OF SERVICE CABINET WITH ADDRESS, (SEE STD. PLAN #123.1). 7. INSTALL TYPE 1 JUNCTION BOX W/ CONCRETE PAD ON NORTH SIDE OF NEW SERVICE CABINET. POLE ID. NUMBER TO BE ADDED AT TIME OF CONSTRUCTION POWER SOURCE FROM PSE, COORDINATE AT TIME OF POWER APPLICATION LABEL BACK SIDE OF NEW SERVICE CABINET WITH 1 0 LP 5 STA. 20+43.55, NILE AVENUE NE 2....�.. I STA. 30+00.00, . NE 2nd COURT ILLUMINATION POLE SCHEDULE POLE NO. STREET POLE STATION OFFSET MOUNT VOLTAGE WATTAGE/ LUMINAIRE TYPE BASE COMMENTS ID NO. HEIGHT TYPE DISTRIBUTION LP # 1 NE 2nd COURT 30+44.0 17.0 ' LT. 14' 240 44 LED PRESTIGE CY17TA—VS3AR-3L-44W-4K FIXED NEW POLE PER STD. PLAN #116.1 LP#2 NE 2nd COURT 30+93.0 17.0' RT. 14' 240 44 LED PRESTIGE CY17TA-VS3AR-3L-44W-4K FIXED NEW POLE PER STD. PLAN #116.1 LP#3 NE 2nd COURT 31 +50.0 17.0' LT. 14' 240 44 LED PRESTIGE CY17TA-VS3AR-3L-44W-4K FIXED NEW POLE PER STD. PLAN #1 16.1 LP#4 NE 2nd COURT 32+16.0 17.0 RT. 14 240 44 LED PRESTIGE CY17TA—VS3AR-3L-44W-4K FIXED NEW POLE PER STD. PLAN #116.1 LP 5 # NE 2nd COURT 32+50.0 17.0' RT. 14' 240 44 LED PRESTIGE CY17TA—VS3AR-3L-44W-4K FIXED NEW POLE PER STD. PLAN #116.1 LP # 6 NILE AVE. NE 20+87.66 17.0 ' RT. 35' 240 94 LED ATBO 40BLEDE70 MVOLT 700 mA DRIVER R3 NL FIXED NEW POLE PER STD. PLAN #115 OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425-260-3412 CONTACT: DARRELL OFFE, P.E. z 2 27460 e Q)ST 1 O�FsS/NALR�`�G\ 09 /22 /2014 NO. RELOCATED LP#6 DUE TO EX. UTIL ADDED ILLUMINAIRE AT ENTRY REVISION SURVEYED: SURVEYED DESIGNED: D.L. OFFE, P.E. DLO 09/19/14 DRAWN: D.L. OFFE, P.E. DLO 08/11/14 CHECKED: BY DATE APPR 1 AP'ROvm: SCALE EXISTING UTILITY LOCATI❑NS SHOWN HEREON ARE APPR❑XIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESP❑NSIBILITY TO DETERMINE THE EXACT VERTICAL AND H❑RIZ❑NTAL L❑CATI❑N OF ALL EXISTING UNDERGROUND UTILIITES PRI❑R TO C❑MMENCING C❑NSTRUCTI❑N. NO REPRESENTATI❑N IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATI❑N. CALL BEFORE YOU DIG: 811 ENLARGEMENT OF INTERSECTION SCALE: 1 "=10" R=3 73 923 STREET LIGHTING SYSTEM TO BE INSTALLED T=373904 UNDER A SEPERATE ELECTRICAL PERMIT USE SCHEDULE 40 PVC UNDER SIDEWALKS, 4 T=37390 USE SCHEDULE 80 PVC UNDER PAVED AREAS. CONDUIT AND WIRING SCHEDULE RUN NO. CONDUIT WIRING 2 " P VC SCH. 40 3— #8 T H. W. COPPER F1 2" P VC SCH. 80 3— #8 T H. W. COPPER ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL. NAVD 19M HORIZONTAL: NAD 1983/1991 DATUM - CITY OF RENTON Planning/Building/Public Works Dept. GRAPHIC SCALE 0 15 30 60 1 inch = 30 feet Checked for Compliance to City Standards RENTON 7 SHORT PLAT JAYMARC HOMES, LLC STREET LIGHTING PLAN NE 2nd COURT / NILE AVENUE NE 09/22/2014 PAGE: L-1 EET. 13 OF: 15 IN7 C 2 rn � m m N co Z m z m M m O A n O z G) Z a) M M Z 0 fi - '39saio y