Loading...
HomeMy WebLinkAboutWWP2703739.2Nt O N T�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~ Q 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. J n 6. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT, SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 7. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. IIr O 8. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE = SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL (n ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. �' 9. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE z AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 0 O 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE z THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. w 10. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. 11. DATUM SHALL BE CITY OF RENTON, 1988 NAVD. 12. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 13. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7 OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE. 14. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 15. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 12 INCH ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. 2" CLAS *2„ CLA CLA ' ll MIN MIN MINMIN MIN F- 6.5' M I N . ~i 2" DEPTH OF GRIND OR SAWCUT AND REMOVE * SEE DWG# HR-05 FOR MINIMUM STANDARDS OF CURB OR OF PAVEMENT 2" CLASS 'B' ;ENTER LINE OR .ANE LINE 6.5' MIN. 1' 1' 2.5' 1' 1' MIN I MIN MIN MIN MIN I *ACP CLASS 'E' OR 'B' 6" CRUSHED SURFACING TOP COURSE CRUSHED ROCK, FLOWABLE FILL OR AS REQUIRED BY ENGINEER TYPICAL PATCH FOR FLEXIBLE PAVEMENT WHEN PERPENDICULAR TO ROADWAY CENTERLINE ADOPTED CITY OF RENTON STANDARD PLANS LST DATE:12/96 DWG. NAME: HR-23 SP PAGE: H032A TYPICAL PATCH FOR FLEXIBLE PAVEMENT N.T.S. OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425-260-3412 CONTACT: DARRELL OFFE, P.E. titi L 0P L- ° °PEE N�TA0 ., q�^ ti e� z 27460 0 O,x,FSS ONALR�'�G\ 06/11/2014 N0. V S R.ENTON SEWER COVER & FRAME PLAN VIEW BOLTHOLES -- 3 PL.CS EQJAL"Y SPACED 120' APART UN 23 1/16' (586mm) nTA R-C. kFF nFTAILS 25' DIA. [635m", 1" 73/4' �8 3/4' ' # 2 1/2' -- 1 [222MMI 1 :64mfiJ TYP COVER SECTION VIEW 26 1/2' DIA [673nr1) 25 1/4' DIA m) DIAt [27rrnXA] 1 1/I6' Fir- 1/4' C6a1M? DIA NEOPRENE GASKET i 5/8' J ? 23 3/8' DIA CL OPEN I C16nn) [594mm.1 I g 27 5/16' DIA C694mm3 34 1/8' DIA �I COVER BOTTOM VIEW BET SOC. (ALLEN HEAD) 5/8"-11 X 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4' 1 1/16, CFinnx 127mml 1f8' t l amm1 1/8' _, eta�rr; GASKET GROOVE DETAIL [867mm) NOTES: FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN !RON WORKS lNC. No 3717C1 OR EQUAL, 2. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "'SEWER"), OR WATER (SPECIFY "WATER"). •1 r� STD. PLAN - 401 PUBLIC WORKS MANHOLE FRAME AND COVER----- ----- --- �.`* DEPARTMENT DECEkIBER 2008 SURVEYED: GEODIMENSIONS, INC. DESIGNED: D.L. OFFE, P.E. DRAWN: D.L. OFFE, P.E. CHECKED: REVISION BY DATE APPR APPROVED: BACKFILL MATERIAL (SEE NOTE 5) CONCRETE CLASS C (SEE NOTE 8) FOUNDATION LEVEL- BACKFILL MATERIAL (SEE NOTE 5) BEDDING MATERIAL FOR RIGID PIPE (SEE NOTE 6) FOUNDATION LEVEL - BEDDING MA_ FOR FLEXIBLE (SEE NOTE 7 FOUNDATION W (SEE NOTE 4) (CLASS A DESIGN) W (SEE NOTE 4) C Do Kel- bm - • (CLASS F DESIGN) BEDDING FOR FLEXIBLE PIPE 1:3:5 MIX CONCRETE BLOCKING LIMITS OF PIPE ZONE LIMITS OF PIPE ZONE C -S OF PIPE ZONE AI NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICTATIONS FOR TRENCH WIDTH "W" AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH, EXCEPT FOR CLASS A BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1-1/2 I.D. + 18". 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING SEWER TRENCHES" IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE BACKFILL MATERIAL. 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS FOR THE MATERIAL SPECIFICATIONS. 7. SEE "BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECTION OF STANDARD SPE.;IFICATION FOR THE MATERIAL SPECIFICATIONS. 8. PIPE MUST BE ANCHORED IN SUCH A MANER AS TO ENSURE FLOW LINE IS MAINTAINED. BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F A 4" MIN. 1/4 I.D. 12" MAX. * * ZERO B 1/4 O.D. 1 /2 O.D. 1/8 O.D. ZERO O.D. C 3/4 O.D. 1/2 O.D. 1/8 O.D. O.D. - * A = 4" MIN. 27" I.D. AND UNDER 6" MIN. OVER 27" I.D. 4-4-97 lCorrected note 4 1 DCVI DT 2-21-91 lRevised notes, 4,5,7,& 8. Added note 6 1 KJ ---- DATE I REVISION 18Y APPR PIPE BEDDING FOR SANITARY SEWER L__) Y ADOPTED CITY OF RENTONSTANDARD PLANS'A�N -� O`; LST DATE: 4/97 DWG. NAME: BW18C SP PAGE: B077 WIPE BEGGING FOR SANITARY SEWEE 6" BUILDING SEWER PIPE TEE WITH 6" SIDE OUTLET 6" SIDE SEWER AND BUILDING SEWER 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. 6" SIDE OUTLET TEE SEWER MAIN 6" MIN. CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER__25 2"x 4" STUD MARKER POST PAINTED WHITE WITH THE WOR "SEWER" STENCILED PROPERTY LINE IN 3" HIGH BLACK LETTERS AND #6 WIRE z WRAPPED AROUND THE STUD AND EXTENDED TO THE TOP OF THE STUD. 0 10 FUTURE BUILDING SEWER z z J }\_6"x6"x6" WYE WITH A SURFACE CLEANOUT WITH o- a CAST IRON RING & COVER 0 (EAST JORDAN IRON WORKS Of a 2975 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID, SEE STD. PLAN 403.1 FOR INSTALLATION) ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN LINES ARE AS FOLLOWS: �NO\s-\ A. VITRIFIED CLAY MAIN -CUT IN A NEW TEE USING FLEXIBLE COUPLINGS(FERNCO OR APPROVED EQUAL). C��<JG B. CONCRETE MAIN -CORE -DRILLED WITH ROMAC SADDLE (OR APPROVED EQUAL). 2 pr1G�� C. PVC MAIN -CORE -DRILLED WITH ROMAC SADDLE (OR APPROVED C 2% MIN SLOPE EQUAL) OR CUT IN NEW TEE USING RIGID COUPLINGS / HORIZONTAL D. DUCTILE IRON MAIN -CORE -DRILLED WITH ROMAC SADDLE (OR APPROVED EQUAL). SEWER MAIN E. MANHOLE CONNECTION -ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE TYPICAL SIDE SEWER ELEVATION STRUCTURE SHALL BE CORE -DRILLED. NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. �T STANDARD SIDE SEWER INSTALLATION (SEWER MAIN TO PROPERTY LINE) STD. PLAN - 406.1 373922 S=373904 S 373902 VERTICAL: NAVD 19M SCALE HORIZONTAL NAD 1983/1991 ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY .- CITY OF RENTON Planning/Building/Public Works Dept. RECOMMENDED FOR APPROVAL By: --,, Date: By: Date: By: Date: By: Date: RENTON 7 SHORT PLAT JAYMARC HOMES, LLC SEWER DETAILS & NOTES NE 2nd COURT / NILE AVENUE NE 02/15/2014 PAGE: SHEET: 10 OR 15