HomeMy WebLinkAboutWWP2703742.1mw 1149 SEC, 2% 123 mc9 R, 5 E, Como I \ SEWER AND UTILITY SERVICES PLAN z SCALE: 1 "=20' ....■■■■■■■_ ■■■■■■■■■■ 1 ■■■I �■N■ Lzo tow 1 :ii :::ii■iiiiii:i==: 485 Rainier Blvd N, Ste 201 W P.O. Box 1787 425-391-1415 Issaquah, WA 98027 www.teccivil.com W J CALL BETE YOU aG 1-800-424-5555 FOR FIELD LOCATION OF UNDERGROUND UTILITIES KV411 r� b�26�1�f 26,98 kg r EGGS EXISTING I EXISTING FH ---- — ---- — _—--------- / SURVEYED: CITY COMMENTS WNT 6 26 14 ISSUED FOR CONSTRUCTION WNT 6/2/14 DE NT 3 SCWSD DRAWING SET WNT 5 22 14 D1 WT 2 AGENCY COMMENTS WNT 5 9 14 CHEa� T NO. REVISION BY DATE APPR A"w-w- SCALE waffr,1 "=20' HOWOWA`AL NO 1i�eNWD� 3/1j1W1 ONE '"a" DATUM AT FULL WALE S 374201 iF NOT ONE MICli SCALE ACCOM MMY 3 0 44 0 U FW- SEWER SERVICE NOTES: 1. SANITARY SIDE SEWER BUILDING SERVICE PIPE SHALL BE PVC, ASTM D3034, SDR 35 2. COORDINATE INVERT ELEVATION AT THE POINT OF CONNECTION (BUILDING 5-FOOT LINE) WITH BUILDING MECHANICAL DESIGN AND INSTALLATION PRIOR TO INSTALLING THE BUILDING CONNECTION. 3. PROVIDE A CLEANOUT PER TYPICAL DETAIL AT THE POINT OF CONNECTION (BUILDING 5-FOOT LINE) AND ALL HORIZONTAL BENDS EXCEEDING 10 DEGREES. 4. SIDE SEWER BUILDING SERVICE PIPE SHALL BE INSTALLED AT 2% MINIMUM SLOPE UNLESS OTHERWISE INDICATED AND APPROVED BY THE PERMITTING AGENCY. 5. UNLESS OTHERWISE INDICATED, CONNECT SIDE SEWER PIPE TO MAIN WITH MANUFACTURED "WYE" OR "TEE" WITH A 45 DEGREE DROP TO THE MAIN. 6. ALL TRENCHING AND BACKFILL SHALL BY PER TYPICAL DETAIL. 7. EXCEPT WHERE OTHERWISE INDICATED, RESTORE ALL FINISH SURFACES CUT AND REMOVED FOR THE SIDE SEWER TRENCH TO MATCH EXISTING. CONSTRUCTION NOTES.' (DNEW 3/4" 0 WATER SERVICE PIPE TO NEW BUILDING PER SOOS CREEK WATER DISTRICT PLAN SET �2 REBUILD SANITARY SEWER SERVICE WITH SLEEVE UNDER NEW BUILDING, 6" 0 MINIMUM (MATCH EXISTING) PVC SANITARY SEWER SERVICE PIPE AT 0.020 ft/ft MINIMUM SLOPE U 6" 0 PVC SANITARY SEWER SERVICE PIPE TO NEW BUILDING AT 0.020 ft/ft MIN. SLOPE 4 LINE SIZED CLEANOUT PER DETAIL 11 /C5.1 5 FIRE SPRINKLER WATER SERVICE PER SOOS CREEK WATER DISTRICT PLAN SET 6 FIRE HYDRANT ASSEMBLY WITH 5" STORTZ FITTING PER SOOS CREEK WATER DISTRICT PLAN SET 7 FIRE DEPARTMENT CONNECTION PIPE AND RISER SIZED BY UL CERTIFIED SPRINKLER DESIGNER SHEET NOTES. 1. THE WATER SERVICE SIZES SHALL BE DETERMINED BY THE BUILDING MECHANICAL DESIGNER, FOR DOMESTIC, AND A UL CERTIFIED FIRE SPRINKLER DESIGNER FOR FIRE SPRINKLER SERVICE AND FDC CONNECTION. THE SIZES SHOWN HEREON ARE PROVIDED FOR PERMIT REVIEW AND ARE TO BE CONSIDERED APPROXIMATE ESTIMATES. 2. THE BUILDING SANITARY SEWER SERVICE SHALL MEET THE REQUIREMENTS SPECIFIED IN THE SEWER SERVICE NOTES HEREON. THE EXISTING SEWER SERVICE PIPE MAY BE REUSED IF THE SIZE, TYPE, SLOPE AND CONDITION WARRANT AND ALL INDICATED SPECIFICATIONS ARE MET. RECOMMENDED FOR APPROVAL i BY: — — — — — — — — — — — — DATE---i—=— BY: -------------------- DATE ------- BY: _— — — — — — — — DATE ------- BY: -----— — — — — — — — — — — — DATE ------- GRAPHIC SCALE -20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. BUILDING PERMIT CHILD School SEWER AND UTILITY SERVICES 4/25/14 C4,1 D D 0 D 0 c D m• �z m C D m U can � z U) 0 D v CD G Z G7 C m m N x OLn CD CD 1 o�x W J 0 0 om 0 n a. U3 w z C S f 3� 0') T: