Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTED4003775.48LiJ
z
C) D
U
w
0 O
a
U.
Z
Q
F-
2
A PORTION OF THE NW 1 /4 OF THE NW 1 /4 OF SECTION 15, TWP. 23 N., RGE. 5 E., W.M., KING COUNTY, WA
.• =X. 7 ; !PF CL INT'X
" STA 1 +76.32, WHITMAN CT NE
" _7, STA. 52+63.97, ROAD B DRIVEWAY APPROACH TABLE
wr r
CL INT'X
- _
STA 1+ 2.14 WHITMAN N
= STA. 5+79.36, ROAD A
t -'`' ' - :
` 4.J '
``''~'
•V-v-i J.L.t
1 2"0
RT
` t
WHITMAN CT NE
C!'X. C8. TIf 1
--- _ ---�
- __ --- -
iMITED
(LRESIDENTIAL-
- -
.
T
_
�s
-r 89.68
-3C
SEE
_ L
P'`i 12„o -
LOT ill
STAIM - OFFSET - ELEVATION
TRACT B
STA.=51 +00.39, 10.00' RT.
387.96
LOTS 13-14
STA. =51 +41.15, 10.00' RT.
387.71
LOTS 1 1-12
STA. = 51 +71.71, 10.00' RT.
387.92
SEE DRIVE
WAY DETAIL F004-1 ON SHEET DT 01
Tr+�. - - _
-- -1_ _ 13+00 , 1 1 4+00 �'40,- N
- --ca #10-
- - - - - - SEE SHEET RD-01 1 - - - _ _ _., - _ = UTILITY CROSSING TABLE 7 CURB HTABLE
---------:' w - Q
o
• _-___.____ - _ _ � I.E. (W.M.) 385 2 8"0 Bc8
- - - - to 1 CR. (S.D.) 383.83. 12"0
1/4
. -_-
- --- SIDEWALK__ W "I.E.. (S.D.) 383.38, 12� ,/2
5 S DEWALK
- - _ . _ _ :�_ _ �. - - ® CR. (S.S.) 380.96. 800 3/4
-` ------ �
�= _ - - - - - - - - - - ECR
- - LE (S.D.) 383.29, 2"0
STATION
OFFSET
ELEV.
50+09.21
14.24' LT.
388.95
389.85
----
----
369.84
___JLT
390.28
5+34.24
12.00
390.73
A-90'01'32" R-20.00' L=31.42'
- - Q _ - 5 c.R. (s.s.> 380.98, 8
Q iv - -'- PAd= Pam_ , 3 4= f PAD=386.40 I.E. (W.M.) 385.03, 1200
\ CL I X '� O TR C 387.So PAD PAD F ® CR. S.D. 384.04, 8"0
_ ROAD A ' � t� #12, TYPE 1 �7.� 387.50 387.50 TR M ( ) g CURB STABLE
.. „+41.21, ROAD B --
-\ STA. 5+00.00, ,�„ O
(� #13. TYPE t
4. [3' I Aa. -6 ® ST BI-DIRECTIONAL GRATE STA ,-�,
ce /22 PAD-W6.40 ALLOWABLE PIPE MATERIALS BCR
w -51 +39.35. 0.42 RT. ry
SEE SHEET SP-03 __ 1 51 +03.70, 0.58' RT. - - - , 4
----- - ROAD B - ___
_ ' tz�._ _ 1, REINFORCED CONCRETE PIPE /
50+00 _'. __ _--------- -;� 7 2. IRON (WATER SUPPLY, CLASS 50 1/2 !�
- DUCTILE (W TE
,,,� 3 -- -. OR 52) 3/4 A
`W �._,.- 4 -, 51 + _ PAD=386.40 3. SOLID WALL POLYETHYLENE PIPE (SWPE E�
-.... _..� LF i "
_.... , n ._ 2 0 SD " - ;-=-----..-.--!.. ALSO KNOWN AS HDPE PIPE OR HDPP)
_ -35- LF, 12 0 SD
TI 1
395
375
STATION
OFFSET
ELEV.
50+73.21
10.00' LT
38823
---
----
388.78
---
----
389.32
---
----
389.87
5+30.00
12.00' RT.
390.42
A-90`00'00"
R=20.00' L-31.42'
C8 i11, TYPE 2-48"0 - 62.2 `
' � 4. CORRUGATED POLYETHYLENE PIPE (CPEP)
r,_- - 35.7 I _� ..
STA S
' SIDEWALK
CB �14 + ` --- --- `�- PAD=386.40
Q cm 2 - TR. FHEREON
T CERTIFICATION:
-- SEE SHEET RD-06
H _� �- UILT INFORMATION SHOWN ��1 E•
9 IS BASED UPON A FIELD p� 0A
1
TRACT B
ROAD A / ROAD B
14 13 12 11 I Q PAD=385.40
PAD= PAD= PAD= PAD=
387.30 387.30 387.30 387.30 10
S.D.C.O. 6"0 ROOF DRAIN
(TYP,) ® S=1.0% MIN. (TYP.)
aQ 00 to
IA
N w r-: cF
M
w
Q1
r- w
n
�
to
tr
d O
tD
d w
00
rn K)
N
PO
tD
tn
o O
00 tlo
d'
00 0006
ao a0 0D
ao ao r
00 OD 00 0D
^
00 OD
tD �
Coco 0O
to �
a0 00
tri
a0 CO
u� ^
00 0O
in n
00 00
tti
ao co
rn a0
00 w
�' o;
rn 00
°i rn
00 a0
CL INT'X
A 12+22.14. WHITMAN
CT NE
PVI
STA: 51 +51.30
CL INT'X
= STA. 4+29.73, TRACT
D
PVI
ELEV: 387'26
NE
A 13+76.32,
WHITMAN CT
ELEV: 388.35
LP
LP
STA: 51 +38.64
ELEV: 387.51
= STA. 52+63.97, ROAD B
K: 25.08
ELEV- 389.51
,
PROPOSED GRADE
®
LVC: 75.00
o
cMe,
Co
03
O
EXISTING GRADE 0
CL
'2
r-
a°°o
+fn
+
G
W
to
ILJ
-- _._ ---
0.99x
0.
0.61X
11 TYPE - 0 35.70 S=9�406 1 TYP 1
TG=388.35 0.64X TG=387.51
IE=383:95. 6"0 (W) 384.03
IE=38�811` 12"0 (E) 382,76 �
W/
IE=38�88. 12"0 (N) 382.78 B 12 TYPE 1 IE=3N.48-12"0 (N) 383.E
IE12"0 (S) 382.85 t
- _ - BI-DIRECTIONAL GRATE IE=383.90 6"� E - _.-- _---------_J_.--- -- _-.-
=38F31�} t
TG=387.73 ►
IE=383.06 12"0 383M W �
' IE=383:@6-12"0 353.22 N
' IE=38346 12"0 383.23 S
50+00
Ca12 Wari ip Days Safari You Dfb
tl�faa mm Loeaf in Cwftr
aD�+fr,�oof�,wA�
51 +00
52+00
395 400
390 395
385 390
375 380
53+00
SURVEY BY ME OR UNDER MY DIRECT
SUPER 1I ZOCTER,2015
NORMAN E. SON, L.S. NO. 22338
DATE: /- /9'9 _ffi�gn
C^
-
12-15-2017
NM t000 NFn d�
MOD M �M MM cn �M
CL INT'X
A 50+41.21, ROAD B
= STA. 5+00.00, ROAD A
ELEV: 388.35 PVI STA: 5+45.56
PVI ELEV: 391.85
HP STA 5+60.56
HP ELEV: 392.15 CL NrX
K: 5.27 STA 12+22.14. WHITIiAAN
LVC: 30.00 = STA. 5+79.36, ROAD A
w o w an ELEV: 392.53
Q.
M _ + •ate'
- tn
0.819
-38-LF 1200 SD ® S-6.6 e-
4 p
'- PROPOSED GRADE
- EXISTING GRADE 0 CE
10
CB J11 SEE SHEET RD-01
SEE PROFILE TO LEFT
were
6+00
n
SCALE: 1 "=20' HORIZ.
1 "=5' VERT.
20 10 0 20 40
NOTES:
1. SEE SHEET HOR-01 - HOR-03 FOR HORIZONTAL CURVE DATA.
2. EXISTING DRY UTILITIES SHALL BE REMOVED OR RELOCATED BY THE
APPROPRIATE UTILITY COMPANIES AND COORDINATED WITH THE
CONTRACTOR. NOTIFY THE ENGINEER OF ANY DISCREPANCIES.
3. CONTRACTOR SHALL RECORD ANY FIELD DEVIATION FROM THE
ENGINEERING PLANS. THESE RECORDS SHALL BE KEPT ON
CONSTRUCTION DRAWINGS AND TURNED OVER TO THE ENGINEER
UPON COMPLETION OF THE PROJECT.
4. STREET NAME SIGNS AND STOP SIGNS TO BE INSTALLED PER CITY
OF RENTON STANDARDS G012 & GO13. FINAL LOCATIONS TO BE
DETERMINED DURING CONSTRUCTION BY THE CITY. SIGNS WILL NEED
TO BE INSTALLED PRIOR TO AS-BUILTS AND COMPLETION OF
CONSTRUCTION.
R THE CURRENT CITY OF
5. ALL TRENCH RESTORATION SHALL BE PER
RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL.
6. STORM DRAINAGE MAINS SHALL BE VIDEOED FOLLOWING
INSTALLATION. VIDEO TO BE PROVIDED TO CITY INSPECTOR.
7. PROVIDE ETHAFOAM PAD WHEN VERTICAL SEPARATION IS LESS THAN
1 FOOT.
8. STORM DRAINAGE MAINS SHALL BE VIDEOED FOLLOWING
INSTALLATION PER THE FOLLOWING PROCEDURE:
A) THE PROJECT DEVELOPER SHALL SUBMIT TO THE CITY THE
CCTV INSPECTION VIDEOS AND WRITTEN REPORTS. THE CCTV
INSPECTION SHALL INCLUDE ALL PROJECT STORM DRAIN LINES
AND CONNECTING CATCH BASIN AND MANHOLE STRUCTURES
THAT WILL BECOME CITY OWNED/MAINTAINED AND ALL PRIVATE
8 INCH DIAMETER OR LARGER DRAIN LINES AND CONNECTING
CATCH BASIN AND MANHOLE STRUCTURES. SAID VIDEOS ARE
TO BE IN COLOR AND COMPATIBLE WITH THE CITY'S VIEWING
AND RECORDING SYSTEMS. THE CITY WILL ONLY ACCEPT VIDEO
SUBMITTALS ON CD OR DVD THAT IS VIEWABLE BY STANDARD
VIDEO PLAYER (I.E. MPG VIDEO FILE FORMAT) AND IS
COMPATIBLE WITH GRANITE XP. THE VIDEO SHALL REFERENCE
EACH PROJECT DRAIN PIPE SEGMENT TO THE UPSTREAM AND
DOWNSTREAM CONNECTING STRUCTURES AS SOWN (AND
IDENTIFIED) ON THE APPROVED PROJECT CONSTRUCTION PLANS.
B) THE COSTS INCURRED IN MAKING THE INITIAL CCTV INSPECTION
SHALL BE BORNE BY THE PROJECT DEVELOPER. THE
DEVELOPER SHALL BEAR ALL COSTS INCURRED IN CORRECTING
ANY DEFICIENCIES FOUND DURING CCTV INSPECTION, INCLUDING
THE COST OF ANY ADDITIONAL CCTV INSPECTION, EXFILTRATION
TESTING OR AIR TESTING THAT MAY BE REQURIED BY THE CITY
TO VERIFY THE CORRECTION OF SAID DEFICIENCY.
C) THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL COSTS
INCURRED IN THE CCTV INSPECTION PERFORMED SOLELY FOR
THE BENEFIT OF THE DEVELOPER.
VIDEO TO 8E PROVIDED TO CITY INSPECTOR.
TI I
395
wo R=377548
9
CHECKED FOR COMPLIANCE TO CITY STANDARDS
�......
CQNSULTING ENCi1NEERS LLC • / • 0 RRST SUBMITTAL ESM 7 1t 14 SGtF o0
® I s I ♦Ili / / HD WO "'�"t CITY OF WHITMAN COURT of/t3/2otl
AMa.we y 1 SECOND SUBMITTAL ESM 26 t o t = noba=_
st,na zos �
Feearai way. WA 9eoo3 a 1w Nw-mm S • 2 THIRD SUBMITTAL ESM 10/29/t
WN'w.esmCwll.Gom �`.. =_. • : 3 FINAL SUBMITT& ESM 11/20/1y""w"wilRENTON
ROAD AND STORM PLAN AND PROFILE N�
E=ng I ( " �,;�`C 4� 4 MYLAR SUBMITTAL ESM 12/01/1 coo At � � DATUM Planning/Building/Public Works Dept. PERMIT #(J14W3W0 RD-05
•• .....•• w Not owE mm
ESM JOB # 1799-001 --01 3 ANAL 3//Ii NO. REVISION BY DATE APPR SO" AO001DOCLY '' "40
n
a
m
e
mm
LT�
Nz
m
m
m
cn
n
I D
m
0
M.
;0moo
n C
O
�m�
9 W
D
° D mz
r�
L
Imo
_mm
rn-
u�
Nz
z
m
0
D
7�7
D
z
L7
C
co
m
30
cn
m
n
o
CD
m o
�o
D
5, W c
Ate : P57 75V8