TED4003776.7
I Oj LL O U ACCESS OPENING W/24 "0 SOLIDLID(TYP) v 1 FENCE (TYP, O I 66 LF 12" PVC WHITE ® 0.57. 15' WIDE ACCESS DRIVEWAY - CB#9 (TYPE-2 - 48"0 NOTE. - DEAD STORAGE SHALL BE AN AVERAGE OF 6 INCHES DEEP. 12" GRATED AIR VENT -I-BUILDING PERMIT REQUIRED FOR IDETENTION VAULT CONCRETE WALLS (TYR) POR TION OF THE NE 114 OF SECTION 6, TWP. 22 N., RGE. 5E., W.M. KING COUNTY, WASHINGTON SCALE: I" = 20' 20 10 0 20 40 5'x 10' ACCESS W/ REMOVABLE GRATE - 48" DIA CB BASE FOR CONTROL STRUCTURE --4LF 12" SD ® 0.5% 49 PERK FILTER VAULT W/5-12'118" CARTRIDGE STACKS RIM=128.2t IE=115.86 (IN) IE=112.36 (OUT) -CHAIN LINK GATE CHAIN LINK GATE TO BE COATED BLACK VINYL. 4" GRAVLL WWAt I LU Utl'1 fi CRUSHED SURFACING TOP COURSE 2 GRAVEL TOPPING DETAIL 7 NOT TO SCALE FENCE (TYP) PULL POST TENSION WIRE FABRIC BAND (TYP.) STRETCHER BAR (TYP.) BOTTOM TENSION WIRE (TYP.) (NOT REQUIRED FOR CHAIN LINK FENCE TYPE 4) 1 CHAINLINKFENCE77PE3 7 NOT TO SCALE WSDOT L-20.10-02 FENCE TO BE COATED BLACK VINYL. GATE POST (TYP.) - 3 1/2" (IN) DIAM. (NOM., SCH. 40) RINGS - SPACED " (IN) MAX. (TYP,),7\ TENSION WIRE TENSION WIRES PULL POST SPACED HOG RINGS (TYP.) SPACED 0 24" MAX. BRACE POST 312" POST AND RAIL SPECIFICATIONS 1 5 " - PIPE ROLL FORMED POST \ NOM. SIZE WEIGHT (SCH. 40) SECTION (Ib/ft) _E 1. D. FENCE LINE END, CORNER, OR PULL POST 2 1/2" DIAM. O 5.10 FABRIC LOOP 2 SIDES O O LINE OR BRACE POST 2" DIAM. OZ 1.85 EYE NUT EYE BOLT TENSION WE EYE BOLT p TURNBUCKLE EYE NUT TURNBUCKLE TIE WIRES (TYP.) ®W1� E SPACED p ` SPACED ® 14" MAX. TENSION WIREMAX ) )UBLE 14 FT CHAIN LINK GATE - PAY LIMIT )UBLE 20 FT CHAIN LINK GATE - PAY LIMIT 14' - 0" OR 20' - 0" TIE WIRES (TYP.) - SPACED 0 14" (IN)MAICH FENCETOP HINGE 180 SELVAGE (TYP.) SWING (TYP. ROD (TYP.) .,,..„,.,,..,,..,,.�,,,,.....,,..,, ,,,. ..,,.., ., ...,- ....... ....... 18 BOTTOM HINGE MATCH FENCE 180� SWING (TYP.) CHAIN LINK FENCE FABRIC SELVAGE (TYP.) 3' 10" - CHAIN LINK FENCE TYPE 3 2' - 0" - CHAIN LINK FENCE TYPE 4 I 12" ROUND TYP.) FABRIC BAND TENSION WIRE (I TURNBUCKLE TENSION WIRES TENSION RES II 11 (TYP.) 11 TENSION WIRE il �-STRETCHER HOG RING ti SPACED , EYE BOLT FABRIC BAND (TYP.) ill t�STRETCHER EYE 1ENSION WIRE BIR (TYP.) ®24' MAX' .. BIR (TYP.) PULL POST (AT END OR CORNER) PULL POST (WITHIN RUN) FABRIC BAND STRETCHER BAR DETAIL n °BRACE DETAIL QD POST Ii u DETAIL NOTES. END OR CORNER (BRACE) POST POST FABRIC 1. ALL CONCRETE POST BASES DETAIL SHALL BE 10" MINIMUM Fc SPACED 15' Max DIAMETER. 2. ALONG THE TOP AND BOTTOM, USING HOG RINGS, FASTEN THE CHAIN CH IN LINK FENCE TYPE 3 OR 4 - METHOD OF FASTENMIG STRETCHER 84R TO POST LINK FENCE FABRIC TO THE TENSION WIRE - PAY LIMIT WITHIN THE 10' - 0" TYP. LIMITS OF THE FIRST FULL FABRIC WEAVE. PULL POST q TENSION WIRE TENSION WIRE 3. DETAILS ARE ILLUSTRATIVE AND SHALL NOT ------ -- LIMIT HARDWARE DESIGN OR B POST SELEC- TION OF ANY PARTICULAR FENCE TYPE. TENSION WIRES `-� HOG RINGS - SPACED'----' FABRa ® 24" (IN) MAX. (TYP.) TOP 3 CHAINLINKGATE 7 NOT TO SCALE WSDOT L-30.10-02 FENCE TO BE COATED BLACK VINYL. 12" AIR VENT 24" SOLID LID 2/4" FRAME & x LEVELING BRICKS GROUND EL=128.52(f) 244" FRAMEL& LEVELING BRICKS I-- -- EL=127.52 - = EL=126.52 2 5' 24.5' ------------------------- -------- ----- 50 YR. EL=126.02------ ---------------------------- 1270 INLET IE=124.0 -' O ------------------------- ------------------------- ---- 2 YR. EL=125.92----------------------------------- 0 O I 0 11� i BUILDING PERMIT III o REQUIRED FOR -III-� K' 8" INTERIOR WALL d - DETENTION WALLS (TYP.) O - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ° EL=116.0 ------------------------------------------- - I - 57 5% 5q° 5% EL=115.69 4" PERFORATED VA T 1 SECTION (A A) UL EL=115.20 WALL DRAIN TO DAYLIGHT (TYP.) SCALE.' 1 "= 5' -12" AIR VENT 5'x 10' ACCESS 2470 SOLID LID 214 " FRAME & W/4" FRAME & LEVELING BRICKS GROUND OPENING LEVELING BRICKS 1' MIN. SOIL COVER EL=128.52 i f I Ili it III iI=4 'il _ ,� -II EL=127.52 _ EL 12652 -I�-111=1i1=I�) ------------------------------ -11 ---------------- - 50YR. EL=126.02------------------------- ----------------------- -------------------------------------------------------------------------------�--------------� -I li �IIIIIII�III�II - ------------ - ------------------- 2YR. EL=125.92----------------------------------------------------------- ------------------------------------------------------------------- o o _-----------o ---------------- _ I! IIII O c 04 0 ° O C O . 810 INLET 1270 INLET w Q 5'x7' INTERIOR e t_' BUILDING PERMIT FLOW RESTRICTOR _ IE.• 124.0 IE 124.0 0 LO OPENING REQUIRED FOR - DETENTION VAULT (SEE DETAIL C8) ___1I=1 O O O 5 x7' INTERIOR o 8" INTERIOR o "? o (i CONCRETE WALLS (TYP.) II- III_ -III= O OPENING WALL o POLYPROPYLENE I=I -I I j270 OUTLET o STEPS (TYP) i =VE-116.0I- - (I - - - ------------------ - ------ 5% --DEAD STORAGE EL=116.0 ------------ ------------------------------------ -------------------------------------------------------------------------------------------- 5% --- = EL-115' - 69 5% .� LEVEL EL=115.20 (I 4 2' -' -- - -- f _ d!- I I, i 4, - I 1;�A�'� 7c�.VAULT I SECTION (B-B) �j / m SCALE: 1 "= 5' 12" AIR VENT 1' MIN. SOIL COVER 12" AIR VENT -------------------------------------------------50YR. EL=126.02------------------------- - DO J O ---- - ------ 2YR. EL=125.92 0 0 O O O r' W 04' II=1�1=I�o0 0 QD 0 I�000 0 =I (=I I ( POLYPROPYLENE (�1 O O o STEPS (TYP) o 11=0 o o ------------- --------------- ------------DEAD STORAGE EL=116.0----------------------------------------------------- -------------------------------------------------------------------------- •5--------------- LEVEL EL=115 20-- - I . I I I-) IIII=i l iIli1 i_! VAULT I SECTION (C-C) SCALE: 1"=5' - EYE NUT Nr T NSION WERE TENSION WIRE JAR GATE POST V DETAIL AO FABRIC BIND (TYP. STRETCHER BAR (TYP.)J PULL POST DETAIL gTENSION R BAR STRETCHER BAR (TYP.) AND TENSION WIRETENSION WIRE RNBUCKLEJE WIRE (TYP.) (NOTtatQQUUIIRED FOR CHAIN UNK OLT TYPE 4) GATE POST PULL POST DETAIL © DETAIL QD NOTE 1. MATERIALS SHALL MEET THE REQUIREMENTS OF STANDARD SPECIFICATION 9-16. • c Know whars below. Call before you dig. UTILITYCONFLICTNOTE:- TURNBUCKLE BOLT TENSION WIRE FABRIC BAND (TYP.) BOLT -INSION WIRE (TYR) (NOT -REQUIRED FOR CHAIN LINK FENCE TYPE 4) R 37760 7 CAUTION• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR CONSULT TO PROCEEDING WITH CONSTRUCTION. m z m umi 0 v D 0 0 10 7 0 c 0 9cn C o . o z �_ o0o n m n S u Z z Ln 0 m G_ Z C m m I � r O a � � x 1 17' I ITi 0 0 O m0 D co A G $ � z