Loading...
HomeMy WebLinkAboutTED4003776.8PORTION OF THE NE 114 OF SECTION 6, T WP. 22 N. R GE. SE", W. M. KING COUNTY, WASHINGTON 2 co m M = Z cn � a RECTANGULAR NOTCH WIDTH: 0.010 FT s HEIGHT: 2.091 FT 12" FR.O.P. TEE ---- PIPE SUPPORTS. NO. AS REO'D 3" X 0.9 GA. BOLT OR IMBEDDED 23" (MIN.) IN C.B. WALL ® 3' (MAX) SPACING. MIN. 1 ' SUPPORT EL=116.0 ORIFICE #1 = 0.84" DIA. OR 15/16" RESTRICTOR PLATE TO BE SHARP EDGED. SHOP DRILLED 2X 036.00" BOLTED & GASKETED ACCESS COVERS. RISERS & SLAB T&G IMPRESSIONS AS REQUIRED. FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. SEE NOTE 2. TOP SLAB RISER T&G _ IMPRESSION, AS REQUIRED. 018 MAXIMUM. SEE NOTE 3. 1.5 X I 1112" 0 SD - - - - - 0. F EL=126.02 POLYPROPYLENE SAFETY STEPS AND LADDER -� CLEANOUT/SHEAR 2 GATE C8 -- ----�---L-- � --- o t l� N Z g 4' 1 FLOWRESTRICTOR C'8 NOT TO SCALE VENTED OUTLET HOOD. 018" MAXIMUM. SEE NOTE 3. BASE - { �I BASE SECTION. PERK FILTER'"' t .:. CARTRIDGES. CONCRETE FALSE FLOOR. OUTLET CHAMBER. CONCRETE DIVIDER WALL. INLET GALLERY. INLET WEIR/BYPASS ASSEMBLY. 5'x 10' ACCESS OUTLET SUMP NOTES: 1. PRECAST CONCRETE STRUCTURE SHALL BE MANUFACTURED IN ACCORDANCE WITH ASTM DESIGNATION C857 AND C858. 2. FILTER SYSTEM SHALL BE SUPPLIED WITH TRAFFIC RATED (H20) BOLTED & GASKETED 036" CIRCULAR ACCESS COVERS WITH RISERS AS REQUIRED. SHALLOW APPLICATIONS MAY REQUIRE CONFIGURATIONS WITH (H20) BOLTED & GASKETED SQUARE/RECTANGULAR ACCESS HATCHES. CONTACT KRISTAR ENTERPRISES, INC FOR ENGINEERING ASSISTANCE. FIELD POURED CONCRETE COLLARS REQUIRED, BY OTHERS. 3. INLET & OUTLET PIPE(S) (0 18" MAXIMUM) MAY ENTER DEVICE ON ALL THREE SIDES OF THE INLET & OUTLET CHAMBERS RESPECTIVELY. FOR PIPE SIZES GREATER THAN 0 18", CONTACT KRISTAR ENTERPRISES FOR ENGINEERING ASSISTANCE. 4. INLET CHAMBER SHALL BE SUPPLIED WITH DRAIN -DOWN DEVICE, DESIGNED TO REMOVE STANDING WATER BETWEEN STORM EVENTS. 5. PERK -FILTER SYSTEMS MAY BE SUPPLIED WITH INDIVIDUAL OR MULTIPLE 18" OR 12" HIGH PERK -FILTER CARTRIDGES. FILTER CARTRIDGE MAY BE STACKED TO ACCOMMODATE HIGHER FLOW RATES. CONTACT KRISTAR ENTERPRISES FOR CAPACITIES. 6. FOR DEPTHS LESS THAN SPECIFIED MINIMUMS CONTACT KRISTAR ENTERPRISES FOR ENGINEERING ASSISTANCE. *TREATUENT FLOW RATES SHOWN CONFORM TO WASHINCTON STATE CULD SPEC,--CrIT/ 0I15. BAB WA 2ce I �1L LAB FLOATABLES WEIR. PRIMARY BYPASS BETWEEN FLOW THRU TUBES. FLOW THRU TUE INTO FILTER CH, PERFORATED DRAIN-D, FEED-THRU. SITE SPECIFIC DATA REQUIREMENTS STRUCTUREID CB#8 WATER QUALITY FLOW RATE (Cfs) 0-06 PEAK FLOW RATE (cfs) 0.98 RETURN PERIOD OF PEAK FLOW (yrs) 100 YR. # OF CARTRIDGES REQUIRED 5 CARTRIDGE FLOW RATE 17 MEDIA TYPE (CSF, PERLITE, ZPG, GAC, PHS) ZPG PIPE DATA: I.E. MATERIAL DIAMETER INLET PIPE #1 115.86 SD 12" INLET PIPE #2 N/A N/A N/A OUTLET PIPE 112.36 SD 12" RIM ELEVATION N/A ANTI -FLOTATION BALLAST WIDTH HEIGHT NOTES/SPECIAL REQUIREMENTS' W/ SOLID LOCKING LID * PER ENGINEER OF RECORD DETAIL A INLET WEIR/BYPASS ASSEMBLY & DRAIN -DOWN. SCALE: NONE 018" MAXIMUM. SEE NOTE J. �1 A MAXIMUM OPENING OF GATE HANDLE LIFT HANDLE SHALL BE o w/LOCK PIN ATTACHED PER ADJUSTABLE MANUFACTURER'S LOCK HOOK O RECOMMENDATIONS. ECilt.)tti 5. i Rtx)F dK)Va'1tiSF'C3t T CON 112f)L.S w/LOCK SCREW ALTERNATES ARE ACCEPTABLE - PROVIDED MATERIAL SPECIFICATIONS ARE MET AND FLANGE BOLT Ff( (!RF S 13.A P'I, RF'()RA'I'l_ll ST`f'B-OUT CONNE("I'ION PATTERN MATCHES SIX EVENLY SPACED HOLES )N 10 3/8" BOLT CIRCLE OR BOLTING TO FLANGE 'ONNECTION. O - - - ' random fill i 7 a Do Q 4' r;tsrf pips, LEVEL LINE 1 " aun ° (� 90 ° VC 7 a ° o o ° 1112" - 3/4'� washed rock O O OaG4°U Uo b as ° p e pn ° a a s O FRONT SIDE--- 24" 2 CLEANOUT/ SHEAR GATE' C'8 NOT TO SCALE A _ 6' TYPICAL DIMENSION i WALL THICKNESS. 018" MAXIMUM. SEE NOTE 3. 0 00 0000 A 11 INLET WEIR/BYPASS 2X FLOW THRU ASSEMBLY. TUBES PER ASSEMBLY. 2X 036.00" BOLTED & GASKETED ACCESS COVERS. RISERS & SLAB T&G IMPRESSIONS AS REQUIRED. FIELD POURED CONCRETE COLLAR REQUIRED, BY OTHERS. SEE NOTE 2. SEE DETAIL A. WASHINGTON INLET WEIR/BYPASS ASSEMBLY. G U D * 018" MAXIMUM.�� SEE NOTE 3. MINIMUM DEPTH - RIM TO OUTLET INVERT - CARTRIDGE STACK CONFIGURATION 12" 18" 12" + 12" 12" + 18" 4.25' (51.00 ] 5.00' (60.00 ] 5.92' L71.007 6.67' [80.007 DRAIN -DOWN DEVICE. SEE NOTE 4. PERK FILTER'"' CARTRIDGE/STACKS. -CARTRIDGE BYPASS PORT. TREATED OUTLETS. CONCRETE FALSE FLOOR. SECTION A A 4' VAULT TREATMENT FLOW RATES, TOTAL FLOW CAPACITIES & MAXIMUM HEAD LOSS CARTRIDGE STACK QUANTITY A DIMENSION - LENGTH - (ID-FEET) CARTRIDGE STACK CONnGURATION 12" 18" 12" & 12" 12" & 18" TREATMENT FLOW RATE FLOW / CFS) TOTAL FLOW CAPACITY (CFS) TREATMENT FLOW RATE (GPM / CFS) TOTAL FLOW CAPACITY (CFS) TREATMENT FLOW RATE (GPM / CFS) TOTAL FLOW CAPACITY (CFS) TREATMENT FLOW RATE (GPM / CFS) TOTAL FLOW CAPACITY (CFS) 3 7 20.4 / 0.045 2.9 30.6 / 0.068 4.3 40.8 / 0.091 5.0 51.0 / 0.114 6.7 4 9 27.2 / 0.061 2.9 40.8 / 0.091 4.4 54.4 / 0.121 5.0 68.0 / 0.152 6.8 5 9 34.0/0.076 2.9 51.0/0.114 4.4 68.0/0.152 5.1 85.0/0.190 6.8 6 11 40.8 / 0.091 3.0 61.2 / 0.136 4.5 81.6 / 0.182 5.1 102.0 / 0.227 6.9 7 11 47.6/0.106 3.0 71.4/0.159 4.5 95.210.212 5.2 119.0/0.265 7.0 MAXIMUM HEAD LOSS 1.7 FEET 2.3 FEET 2.9 FEET 3.5 FEET TREATMENT FLOW RATES SHOWN CONFORM TO WASHINGTON STATE GOLD SPECIFICATIONS. 4 CB #8 STORMFILTER DETAIL �'g NOT TO SCALE VENTED OUTLET HOOD. 018" MAXIMUM. `SEE NOTE 3. TRENCH X SECTION NTS slope -� to road i drainatle. sVstem 1 2' X 10' level trench E w/pert pipe PLAN VIEW OF ROOF NTS 3 PER, STUB -OUT CONNECTION �R�� �. s . 51,a CI C'8 NOT TO SCALE 1� �a Ga-nnt 1 20 x24" 5/8" I 18 x22" -�_ I- N NOTES: OL YMPIC FO UNDR Y, INC. *MATERIAL: DUCTILE IRON, A-536, CL 80-55-06 BEEHIVE GRATE FOR USE WITH SM60 20 x24" REV. FRAME PART NO. SM60BH VN.' RDCAGEI�ETAIL FOR TYPEI T.S. Know whaYs below. Call before you dig. UTILITY CONFLICT NOTE. - CAUTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR CONSULT TO PROCEEDING WITH CONSTRUCTION. n> 0 0 U O C s i z o z = ti m 'z Z m Cn O T D M z z m M