HomeMy WebLinkAboutTRO4103776.3Know what's below. Call before you dig. PORTION OF THE NE 114 OF SECTION 6, TWP. 22 N., RGE. 5E.I W.M. KING COUNTY, WASHINGTON POLE SCHEDULE POLE NO. POLE ID NO, STREET POLE LOCATION GPS POLE OFFSET LAMP WATTAGE LAMP TYPE DLSTRLBU77ON HOUSE -SIDE MOUNTING ARM LENGTH FOUNDATION CIRCUIT NO. SHIELD HEIGHT DEPTH N 5700.99216 1 ROAD A 0+52. 61 E 501.6916 15.00' L 44 LED 3L NO 14' N/A 4.0' A 2 ROAD A 1 +49.66 N 470. 9181 E 501.7188 15.03' L 44 LED 3L NO ]4' N/A 4.0' A 3 ROAD A 2+62.75 N 346.1356 29.34' L 44 LED 3L NO 14' N/A 4.0' A E 501.5826 4 ROAD A 3+38.05 E 436.2215 14.54' L 44 LED 3L NO 14' N A / 4.0' A N 293.1061 5 ROAD A 3+01.55 N 416.1528 50.37' R 44 LED 3L NO 14' N/A 4.0' A 6 ROAD A 2+04.37 N 416.2068E 471.6690 15.02' R 44 LED 3L N0 14' N/A 4.0' A 7 ROAD A 0+93.57 N 527.0009 E 471.2585 15.43' R 44 LED 3L NO 14' N/ A 4.0' A UTILITYCONFLICT NOTE. - CAUTION.• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARLATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT W17H INSIGHT ENGINEERING COMPANY TO RESOLVE ALL PROBLEMS PRIOR CONSULT TO PROCEEDING WITH CONSTRUCTION. NOTE POLE ID NOS. TO BE PROVIDED BY COR FOR CONTRACTOR TO INSTALL AT TIME OF CONSTRUCTION. Wym R pilliq -1 ml_ - Pol 't r A0 SCALE: 1" = 30' 30 15 0 30 60 LEGEND PEDESTRIAN POLE, LUNINAIRE, FOUNDATION AND TYPE 1 JUNCTION BOX WITH CONRETE PAD +- FLASHING BEACON ASSEMBLY 8 TYPE 1 JUNCTION BOX WITH CONCRETE PAD 0 TYPE 2 JUNCTION BOX WITH CONCRETE PAD ® ELECTRICAL SERVICE CABINET PVC CONDUIT (SEE WIRING SCHEDULE) WIRE NOTE 0 CONSTRUCTION NOTE e GENERAL NOTES: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT CITY OF RENTON STANDARD SPECIFICATIONS AND STANDARD DETAILS. 2. ALL JUNCTION BOXES SHALL BE IN ACCORDANCE WITH WSDOT STANDARD PLAN J-40.10-03. ANY JUNCTION BOX PLACED WITH SIDEWALK OR DRIVEWAY SHALL HAVE ANTI SKID ID AND FRAME. 3. INSTALL ALL FOUNDATIONS, POLES, LUMNAIRES, JUNCTION BOXES PER POLE SCHEDULE AND CITY STANDARD DETAILS ON SHEETS C13 & C14. 4. INSTALL ALL CONDUITT AND WIRING PER WIRING SCHEDULE AND CITY STANDARD DETAILS ON SHEETS C 13 & C 14. CONSTRUCTION NOTES: fO INSTALL FOUNDATION AND ELECTRICAL SERVICE CABNET AT TALBOT, STA. 0+54.56, 15.25'R. CABINET SHALL HAVE TWO ILLUMINATION CIRCUITS MINIMUM. USE CITY STANDARD DI AS 122.1 AND 126.1. LABEL CABINETS AS OCOORDINATE WITH PUGET SOUND ENERGY (PSE) OR NEAREST ELECTRICAL POINT OF SERVICE. ROUTE SERVICE ENTERANCE CONDUIT AND CONDUCTORS TO POINT OF SERVICE PER PSE REQUIREMENTS. COORDINATE WITH CDR TRANSPORTATION MAINTENANCE ASSIST. MANAGER, ERIC CU15MALL PHONE 425-430-7423 FOR SERVICE CONNECTION_ WIRING SCHEDULE RUNNO. CONDUIT CONDUCTORS REMARKS Q2" PVC (SCHEDULE 40) 2-18, 1-#8 GREEN Q 2" PVC (SCHEDULE 80) 2-#8, 1-#8 GREEN 2" PVC (SCHEDULE 40) 2-18, 1-#8 GREEN, 3-#12 PHOTOCELL NST r ?ECA:. %UM- BERS VERTICALLY. NSTAL- !N'DRY 'A ATHER, 50' F 'OR j AB C VE. NUMBERING 4 2 EXAMPLES 3 Ct EG 'YPE 3 ` Is7 WATT "' GE j 1 / RC�� iT 1 AFC All fi f t�� 45'� i FLOW r i � I L A EV t j i L - 'I- 3/4„ v 2.. 2" 70 3" REF -EC C'R!ZE€} OOTHIC GOI,D OR IAiHITF --GENC, GN 'BLACK EAC:KCROU!�r} SM. PLAN - 121 P!. HLIC WORKS STREET LIGHT STANDARD UF:I'ARTY.M V1' DECAL NUMBERING SYSTEM RO ED: T=377603 D r1 � Z �1 J c C 030 Dm cy)cjl Nz m m m 0 D _2 ; D T1 O 00 0O c 119 co D m z �m C CO O T m m- 0K N z z m cn 0 D m D Zn Y i Z C ca m m y r Cd 0 a >,yCD 1 N Cam/] C [•ri ■ `d t-' H j m D If 0 v m a OO A 0 ti M n �W n z