6" CRUSHED SURFACING TOP COURSE,
COMPACT TO 95% MODIFIED PROCTOR
(ASTM D1557)
UNDISTURBED
NATIVE
MATERIAL
PVC PIPE
BANK RUN GRAVEL OR NATIVE
BACKFILL IF APPROVED IN
WRITING BY ENGINEER,
COMPACT TO 95% MODIFIED
PROCTOR (ASTM D1557)
6"MIN.
BEDDING MATERIALS
7_.5'MIN.
NOTE: REFERENCE RENTON STD. PLANS
110.1 AND 405 FOR FURTHER DETAIL.
TRENCH DETAIL FOR GRAVITY MAIN
(OPEN CUT/UNPAVED SECTIONS)
NTS
NEW 60"0
PRECAST
MANHOLE BASE
SECTION
WATERTIGHT MANHOLE
ADAPTOR CONNECTION
( TYP. )
- ----- -
----- -----
EX. 8" CLAY��
INV=86.22± - --
FOUNDATION GRAVEL
(6" MINIMUM)
ADJUSTING RINGS
(4"MIN/16"MAX).
GROUT BETWEEN RINGS.
PLASTER INSIDE FACE w/
3/4" GROUT
CITY OF RENTON STD. MH
FRAME AND COVER PER
STD, PLAN 401 (OR FLAT
TOP PER PLANS)
RUBBER GASKETED, GROUT ALL
JOINTS CONTINUOUS ON INSIDE
,'- AND OUTSIDE OF MANHOLE
w
48"m OR 60"o PRECAST
0 CONC. GROUT POLYPROPYLENE 4 SADDLE MH BASE.
MH WALL MANHOLE STEPS
LLI
_J
Li
aCUT OUT TOP OF
PIPE AFTER
BENCH IS FORMED
z
a
a SEE PLAN WATER STOP
i AND PROFILE { AROUND PIPE TO
PROVIDE WATER
w
FOR PIPE TIGHT SEAL
L, DIAMETER
CONSTRUCT CHANNELS
FOR PROPOSED SEWER
CHANNEL DEPTH MAINS, AS SHOWN ON
SHALL BE 3/4 :7
8"MIN PLANS
OF DIAMETER '
OF THE PIPE
z
4"x8"x8" SOLID 6"MIN N
CONCRETE BLOCK i a
Q° ° ° O o ,g. o w o ° o - o v
°S o °mo,
p°O oQQ oo ° ° oog o� oo o
°p°poft
po o o°•°��000aOpp�OoV�o�b 0°%�
off,�•�•p 000go0oogp_ren000Ro00�o0o008JOo°o o0o°°cAS0�2S o°•• \Oo�OooLAdU ^ o�O0.
o�OOp�o
\ooa' ooC�MU°000 \o\0 0 000 �o°poOp00 0 Apo 000 0 00 �o
6" MIN DEPTH COMPACTED CRUSHED SURFACING CAST IN PLACE
(NON -CAISSON CONSTRUCTION METHODS ONLY) BENCH AND
MANHOLE BASE 55
SADDLE MANHOLE DETAIL
NTS
GENERAL INSTALLATION PROCEDURES (SSMH 006A):
ANEW PRECAST
MANHOLE SECTION
TEMPORARY III=
8" PVC I jI
z
2" i
4IIII
`0 III=
EX. 8" CLAY
"fI I II l L-NEW ROMAC 501
=11 TRANSITIONAL COUPLING OR
APPROVED EQUAL (TYP)
INV=86.68±
INSTALL DROP
CONNECTION PER
STD. PLAN 402.2
SSMH 006A INSTALLATION DETAIL
Stantec
11130 NE 33rd Place, Bellevue WA 98C,01
phone: (425) 869-9448 www,stantec.-c ,
NTS
1, TO INSTALL MANHOLE, THE CONTRACTOR WILL TEMPORARILY INSTALL
BY-PASS SYSTEM FROM EXISTING SSMH 2292 TO EXISTING SSMH 0057.
CONTRACTOR CAN ASSUME A PEAK FLOW RATE OF 10 GPM.
2. EXPOSE AND REMOVE SECTION OF EXISTING PIPE.
3, SET MANHOLE IN PLACE TO PROPER ALIGNMENT AND GRADE,
4. INSTALL NEW 8" PVC AND DROP CONNECTION AS SHOWN IN DETAIL.
5. INSTALL TEMPORARY PLUG IN BOTTOM OF DROP CONNECTION UNTIL
CITY HAS APPROVED SWITCHOVER TO NEW SYSTEM.
6, FOR SWITCHOVER, REMOVE TEMPORARY PLUG FROM BOTTOM OF DROP
CONNECTION AND CUT AND REMOVE PIPE SHOWN AS "TEMPORARY 8"
P VC. "
REVISED TO INDICATE
CONSTRUCTION RECORDS
FIELD REP: SCARSELLA BROS
REVISED BY: IZABELLA MIROCHNIK
DATE: 4-6-2017
CONTRACTOR: SCARSELLA BROS
CRD 10 of 11
RECORD DRAWING
These drawings have been prepared based on
information provided by others. Stantec has not verified
the accuracy and/or completeness of this information
and shall not be responsible for any errors or omissions
which may be incorporated herein as a result.
REVISIONS TO WETLAND FILL.
RE'v S0N
50 EXISTING GRADE
45
MIN. 3" HMA (CLASS )¢") MATCH SAWCUT EDGE OF
EX. PAVEMENT DEPTH /—EX. PAVEMENT,
6" CRUSHED SURFACING TOP COURSE, THEN TACK &
COMPACT TO 95% MODIFIED PROCTOR SEAL JOINT
(ASTM 1557) 1 EX PAVEMENT
MIN.
000°o ° 000 00001
00 00 000 00
'BANK RUN GRAVEL OR NATIVE
UNDISTURBED \// :'::::::`.-::';`::::== \BACKFILL IF APPROVED 9N
NATIVE \/ /WRITING BY ENGINEER,
MATERIAL ,\ • ;:.•:., :• :• : \\ COMPACT TO 95% MODIFIED
PROCTOR
21 MIN.
PVC PIPE
6"MIN.
BEDDING MATERIALS
/./..\ /\\
2.5'MIN.
NOTE: REFERENCE RENTON STD. PLANS
110.1 AND 405 FOR FURTHER DETAIL,
TRENCH DETAIL FOR GRAVITY MAIN
(OPEN CUT/PAVED SECTIONS)
NTS
Ai GRADE TO MATCH EXISTING
FILL MATERIAL TO BE GRAVEL \
BORROW PER SPECIFICATION,
KEY INTO EXISTING SLOPE \
EXISTING 12" CULVERT\\\\ PROP. 18" STL CASING\\� '
35 INV=44.00 W/12" CARRIER PIPE \ \
ETHA FOAM PAD
\\ FILL SLOPE WITH RIPRAP
4" BELOW UD
r
NTS
ACCESS COVER DETAIL, SE 1
10
. a
— PIPE CAP WITH ROUNDHEAD
STAINLESS STEEL BOLT
THROUGH CAP TACK WELD
JJ J,LLL
SEAL PIP!
OR EQ
PIPE &
(SIZE PER PLANS) (TYP.EACH (SIZE PER PLAN)
END)
SECTION A -A NOTES:
12—FT GRAVEL ACCESS
RD PER DTL 9/10 55
PROPOSED BERM
WITH PROTECTIVE RIPRAP 50
(MIN 1' THICK)
38 LF ® 1, 7%
\INV=38.58 ± 35
EX. 12" CULVERT
INV=39.23
CONNECT TO EX.
CULVERT W/COUPLING
TO PIPE CAP. GRAVEL ACCESS
ROAD AS SHOWN
—SPLIT 1 " STAINLESS STEEL ON PLANS
PIPE FOR V-0' AT TIP.
SPREAD ENDS SLIGHTLY,
AND DRNE PIPE TIP BELOW FILL AREA TO MATCH
GROUND SURFACE OR EXISTING GRADE
BOTTOM OF PAVING
2:1 MAX SLOPE
TIP ELEVATION
NEAR SURFACE SETTLEMENT POINT (NSP)
SURFACE SETTLEMENT MONITORING POINT
NTS
SMA 3/30/16 SURVEYED
DESIGNED:
SMA
DRAWN:
CTM
CHECK_:
ELB
BY DATE APPR APPROVED-
0 rA
1. SEAL EACH END OF CASING WITH FLEXIBLE END SEALS SUCH
AS MODEL W BY PIPELINE SEAL & INSULATOR OR EQUAL.
2. CASING SPACERS SHALL BE INSTALLED A MAXIMUM OF 10'
ON CENTER. S L IC
0
�� OF 1 AS�I �IS,
4 PIPE CASING DETAIL 9WI�er�
10 NTS
38087
GISTF,
� SSIONAL
FOR CONSTRUCTION
RECORDS ONLY
These drawings have been prepared based on
information provided by others. Stantec has not verified
the accuracy and/or completeness of this information
and shall not be responsible for any errors or omissions
which may be incorporated herein as a result.
CAST IRON OR STEEL
EXISTING PAVEMENT OR FRAME AND UD,
GROUND SURFACE (AASHTO HS-20 LOAD RATED).
SET FLUSH WITH EXISTING SURFACE.
CONCRETE OR
ASPHALT PAVEMENT
(DEPTH VARIES)
CONCRETE COLLAR
SAW CUT OR CORE DRIL
HOLE FOR FRAME AND IMPROVED AREAS UNIMPROVED AREAS
GROUT IN PLACE
ACCESS COVER IN IMPROVED
AND UNIMPROVED SURFACES
SURFACE SETTLEMENT MONITORING POINT
ACCESS COVER
— CUT AREA TO MATCH
EXISTING GRADE
2:1 MAX SLOPE
- 8"-12" LAYER OF
1-1/4" MINUS GRAVEL
FILL COMPACTED TO 95% PER
SPECIFICATIONS. GEOTECHNICAL
REPRESENTATIVE TO INSPECT
PRIOR TO PLACEMENT.
NTS
S=3812 10
SCALE:
VERTICAL NAVD 1988
CITY O E
AS NOTED HORIZONTAL: NAD 1983183/1991
RENTON
ONE INCH DATUM
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
NTS
REVISED TO INDICATE
CONSTRUCTION RECORDS
FIELD REP: SCARSELLA BROS
REVISED BY: IZABELLA MIROCHNIK
DATE: 7/10/201 7
CONTRACTOR: SCARSELLA BROS
�rL BR0`��
4� 3F WASH
1 co
37847 4
%ISTE��
�SIONAL
1.
W AL IGO
�'1111111,�`�. � pF WASJjrl�
3808,
�GISTEg�\��'�
4400 SIONAL E�
1 CRD SHT. 10 OF 11
DATE:
TALBOT HILL SEWER RELOCATION - 7/10/2017
1-405, SR167 IC/DC PROJECT FIELDBOOK
PAGE:
WWP-27-2812 DRAWING NO:
MISC DETAILS $HEET:10 GE 11