HomeMy WebLinkAboutWWP2703812.2r C C` d IS E C i< C LEGEND EXISTING PROPOSED SANITARY SEWER, FLOW DIRECTION ❑ POWER BOX LIGHT POLE 04 SANITARY SEWER MANHOLE E UNDERGROUND POWER (PAINTED LOCATION) FIRE HYDRANT ASPHALT RESTORATION WATER VALVE W WATER LINE (PAINTED LOCATION) TELEPHONE RISER - C - UNDERGROUND COMMUNICATION (PAINTED LOCATION) CB ❑ CATCH BASIN D STORM DRAIN LINE/ CULVERT GAS VALVE T.E.S.0 GAS METER UNDERGROUND GAS LINE (PAINTED LOCATION) SMH SEWER MANHOLE SCO O SEWER CLEANOUT 0 0 0 SILT FENCE S SEWER LINE x ORANGE CONSTRUCTION FENCE 0'-0"E SET HUB W/PIPE DEPTH PER LOCATOR O CB PROTECTION 52.00 64"-76'* GROUND ELEVATION/POT HOLED UTILITY DEPTH Q 1� INLET/OUTLET PROTECTION EDGE OF PAVEMENT SURVEY NOTES: THE MAJORITY OF THE SURVEY INFORMATION SHOWN IN THE ATTACHED PLAN HAS BEEN PROVIDED BY WSDOT. PER THE 1-405 SR 167 IC/DC PROJECT REFERENCE DOCUMENTS SECTION 2.5.2.1: WSDOT PREPARED AND UPDATED MAPPING FOR PROJECT USING 2013 AERIAL PHOTOGRAMMETRY AND TOPOGRAPHIC SURVEYS. PRIMARY AND SECONDARY SURVEY HORIZONTAL AND VERTICAL CONTROLS WERE ESTABLISHED BY WSDOT WITH GIPS EQUIPMENT IN WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE. HORIZONTROL CONTROLS ARE BASED ON THE NORTH AMERICAN DATUM OF 1983 (NAD 83/91)AND VERTICAL CONTROLS ARE BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) AND AS SPECIFIED AS <0.005M (± LINEAR UNCERTAINTY). WSDOT HAS SUPPLIED AN ELECTRONIC DIGITAL TERRAIN MODEL (INROADS FORMAT) AND 2D MICROSTATION .DGN FILES COMPRISED OF PHOTOGRAMMETRIC AND TOPOGRAPHIC SURVEY DATA IN PROJECT DATUM COORDINATES CONVERTED FROM STATE PLANE COORDINATES USING A COMBINED FACTOR OF 1.000006285. Stantec 11130 NE 33rd Place, Bellevue WA 98004 phone: (425) 869-9448 www.stantec.com B1?60 1� pwAS� j Y m, 37847 GISTS SjONAL CONSTRUCTION SEQUENCE 1. ATTEND PRE -CONSTRUCTION MEETING AND PERMIT COMPLIANCE MEETING, AS REQUIRED BY PERMIT. 2. OBTAIN NOTICE TO PROCEED FROM CITY AND ALL REQUIRED PERMITS BEYOND THOSE PROVIDED BY CITY AND WSDOT (SEE SPECIFICATIONS) PRIOR TO COMMENCING WORK. 3. COORDINATE WITH CITY / ENGINEER FOR CONSTRUCTION STAKING. STAKING TO BE PROVIDED BY CONTRACTOR. 4. INSTALL PERIMETER PROTECTION, TEMPORARY EROSION AND SEDIMENT CONTROLS, AND BMPS. 5. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY AND WSDOT STANDARDS AND THESE PLANS AND SPECIFICATIONS THROUGHOUT THE PROJECT. 6. CLEAR AND ROUGH GRADE SITE. 7. CONSTRUCT HORIZONTAL DIRECTIONAL DRILL SECTION OF SANITARY SEWER MAIN. 8. CONSTRUCT OPEN CUT SECTION OF SANITARY SEWER MAIN SOUTH OF 1-405 PER PLANS. REFER TO SSMH 006A INSTALLATION NOTES AND SSMH 009 INSTALLATION NOTES. 9. UPON COMPLETION OF SANITARY SEWER ALIGNMENT FROM SOUTH 14TH STREET TO SMITHERS AVE SOUTH, INSTALL TEMPORARY GRAVEL ACCESS ROAD TO APPROXIMATE FINISHED GRADE, AS SHOWN ON PLANS. ADJUST RIM ELEVATIONS OF NEW SSMHS AS NECESSARY TO MEET ADJUSTED GRADE ELEVATIONS. 10. CONSTRUCT GUIDED PIPE RAM SECTION OF SANITARY SEWER MAIN. COMPLETELY REMOVE TEMPORARY SHORING SYSTEM OF BOTH SHAFTS TO PREVENT CONFLICTS WITH FUTURE IMPROVEMENTS. 11. CONSTRUCT OPEN CUT SECTION OF SANITARY SEWER MAIN NORTH OF 1-405. 12. PERFORM LEAKAGE TESTING AND TELEVISION INSPECTION OF NEW SANITARY SEWER MAIN. 13. OBTAIN CITY APPROVAL BEFORE TRANSFERRING SEWAGE TO NEW SANITARY SEWER MAIN. CONNECT TO EXISTING SANITARY SEWER SYSTEM. REFER TO SWITCHOVER SEQUENCE. 14. CCTV THE EXISTING SEWER MAIN BETWEEN SSMH 2267 AND SSMH 2257 TO CONFIRM NO CONNECTIONS. NOTIFY CITY AT LEAST 24 HOURS PRIOR TO CCTV OF MAIN. IF NO CONNECTIONS ARE FOUND DURING CCTV OF MAIN, PLUG EXISTING PIPE AT SSMH 2257 TO THE SOUTH. IF CONNECTION(S) ARE FOUND, PLUG EXISTING PIPE AT SSMH 2267 TO THE SOUTH. 15. ABANDON EXISTING SANITARY SEWER FACILITIES AS SHOWN ON PLANS AND AS REQUIRED IN ABANDONMENT SEQUENCE. 16. PERFORM SURFACE RESTORATION. RESTORE SITE NORTH OF 1-405 TO ITS ORIGINAL CONDITION, UNLESS OTHERWISE REQUIRED BY WSDOT. 17. AFTER ALL DANGER OF EROSION HAS PASSED AND AFTER APPROVAL BY CITY AND WSDOT, COORDINATE REMOVAL OR TRANSFER OF TEMPORARY BMPS WITH FOLLOW-UP CONSTRUCTION PROJECTS. 18. PROVIDE CONSTRUCTION RECORD DRAWINGS. NOTE: THIS IS A POSSIBLE SEQUENCE. FINAL SEQUENCE SHALL BE DEVELOPED BY CONTRACTOR AND SUBJECT TO REVIEW BY OWNER. SSMH 006A INSTALLATION NOTES: 1. INSTALL A TEMPORARY BYPASS SYSTEM AND PUMP SEWAGE FROM EXISTING SSMH 2292 TO EXISTING SSMH 0057. CONTRACTOR CAN EXPECT A PEAK FLOW RATE OF UP TO 25 GPM. 2. EXPOSE AND REMOVE APPLICABLE SECTION OF EXISTING 8" CLAY SEWER MAIN, 3. INSTALL NEW SSMH 006A PER PLANS AND IN DETAIL 7, SHEET 10. 4. PLUG DROP CONNECTION TO PREVENT SEWAGE FROM ENTERING NEW SYSTEM UNTIL THE CITY HAS APPROVED SWITCHOVER. 5. ONCE THE CONTRACTOR HAS RECEIVED APPROVAL FOR DEACTIVATION OF EXISTING SYSTEM AND SWITCHOVER TO NEW SYSTEM, REFER TO SWITCHOVER SEQUENCE, BELOW. SSMH 009 INSTALLATION NOTES: 1. INSTALL A TEMPORARY BYPASS SYSTEM AND PUMP SEWAGE FROM EXISTING SSMH 2270 TO EXISTING SSMH 2269. CONTRACTOR CAN EXPECT A PEAK FLOW RATE OF UP TO 400 GPM. 2. INSTALL NEW SSMH 009 PER PLANS AND CONNECT TO EXISTING SYSTEM TO NORTH AND SOUTH AS WELL AS NEW SYSTEM TO THE EAST. 3. PLUG CONNECTION TO NEW SYSTEM TO THE EAST UNTIL THE CITY HAS APPROVED SWITCHOVER. 4. ONCE THE CONTRACTOR HAS RECEIVED APPROVAL FOR DEACTIVATION OF EXISTING SYSTEM AND SWITCHOVER TO NEW SYSTEM, REFER TO SWITCHOVER SEQUENCE, BELOW. SWITCHOVER SEQUENCE 1. AT SSMH 001, CUT OUT TOP OF EXISTING PIPE IN SADDLE MANHOLE. 2. AT SSMH 003, CUT OUT TOP OF EXISTING PIPE IN SADDLE MANHOLE, AND PLUG THE EXISTING PIPE TO THE NORTH. 3. AT SSMH 004 AND SSMH 005B, CUT OUT TOP OF EXISTING PIPE IN SADDLE MANHOLE, AND PLUG THE EXISTING PIPE TO THE NORTH. CONTRACTOR TO START WITH THE MOST DOWNSTREAM MANHOLE (SSMH 004) AND WORK ITS WAY UPSTREAM TO SSMH 007. 4. AT SSMH 006A, REMOVE THE TEMPORARY PLUG FROM THE BOTTOM OF THE DROP CONNECTION AND CUT AND REMOVE THE TEMPORARY 8" PVC PIPE WITHIN THE MANHOLE. REFERENCE SSMH 006A INSTALLATION DETAIL ON THE DETAIL SHEET. 5. AT SSMH 007, CUT OUT TOP OF EXISTING PIPE, AND PLUG THE EXISTING PIPE TO THE NORTH. 6. CONNECT EXISTING SIDE SEWER FOR PARCEL 3340401545 TO NEW SANITARY SEWER SYSTEM. CUT AND CAP EXISTING SIDE SEWER CONNECTION TO EXISTING SANITARY SEWER SYSTEM. 7. AT SSMH 009, REMOVE THE TEMPORARY PLUG AND PLUG THE EXISTING PIPE TO THE NORTH. �S. WALIGO pF WASH SURVEYED: SCALE: HORIZONTAL NAD D1988 1983/1991 DESIGNED: AS NOTED 3 s7 SMA GISTV"?, �� DRAWN: �SSIONAL E�����(0 CTM ONE INCH I DATUM CHEiKSED: AT FULL SCALE �/ n IF NOT ONE INCH N 0. REVISION P DAr E AP P R APPROVED: SCALE ACCORDINGLY Sys WALK WA�� 4ry 7J® 38087 0�� GISTER�� �SSIONAL FOR CONSTRUCTION RECORDS ONLY REVISED TO INDICATE CONSTRUCTION RECORDS FIELD REP: SCARSELLA BROS REVISED BY: IZABELLA MIROCHNIK DATE: 6-3-2017 CONTRACTOR: SCARSELLA BROS '6R C T Y OF "L It RENTON Planning/Building/Public Works Dept. S=381202 RECORD DRAWING These drawings have been prepared based on information provided by others. Stantec has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or omissions which may be incorporated herein as a result. CRD2of11 TALBOT HILL SEWER RELOCATION - 1-405, SR167 IC/DC PROJECT WWP-27-3812 NOTE SHEET DATE: 7/10/2017 FIELDBOOK: PAGE: DRAWING NO: SHEET: OF: 2 11 �m CD c � C7 = C: mC:) m Cy m I u 7 z m �. O D D n 0 m00 O roc ' m C-) W M D ' fzf1 M° ;mm R) z z m 0 D H a r t� 0 x r Hr oz a w1l UQ ~ P o Cn .p. �tTl 1 r coo C) a N °z D n o M 0 00 D �c ED co 2