CITY OF RF.NTON
Approvedby _.. r)ate: 'fr74 r
Approved by:
Apprrsvedby:
Approvedby:
'Date:
Date:
Date:
13"x24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC,
NC. BCE SERIES MSBCF 1324-18 WITH 1.75" THICK DUCTILE
IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS,
INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE
FOR TOUCHREAD PIT LID (SEE DETAIL A -A)
9" MIN
12" MAX
- FINISH GRADE
or - - o
36" MIN COVER N o 0
_ �.\ 22 1/2- �
NEW DUCTILE
IRON
WA TERMAIN
CITY
PRIVAT E
.�
PIPING
I PIPING
I
z
-IN UNIMPROVED RIGHT OF
�I
I
WAY INSTALL METER BOX AT
J
a.
PROPERTY LINE WITH 12"
a
LONG COPPER TAILPIECE.
°
SIDEWALK
a
�
nI
�
a77
TOUCHREAD WATER
II
METER TO BE
12"
SUPPLIED BY THE
Cl TY
TYPE "K" SOFT
I
g
ca
<�
�
IF SERVICE LINE TO HOUSE IS
TO BE INSTALLED IN THE FUTURE
INSTALL FORD C14-33 OR 44 FIPT
x COMPRESSION COUPLING
`LOOP DOWN TO CENTERLINE f
jf OF WATER MAIN TO /
PROVIDE SLACK IN COPPER ZCOPPERSETTER FOR 518"xR 3/4" METEFORD
SERVICE LINE TO METER. \BH72-15W-44-33G, 4R MGDDNALD BRASS: 21-215WCQQ33, OR
MUELLER° 3/4-B-2470-2 WITH ANGLE BALL VALVE ON INLET AND
SINGLE CHECK. VALVE ON CUTLET
CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METER: FORD V13H72-15W-44-44G, OR
TAPERED THREAD (CC). QUICK JOINT MCDONALO BRASS: 21-415WCQQ44, OR MUELLER: 1-B-2470-2
(3/4" F81000-3-0) OR AY MCDONALD 47018 BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON
(1" FRIDOO-4-0) OR AY MCDONALD 4701B INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET -
ALL FITTINGS SHALL BE WITH QUICK JOINT.
NOTE:
ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE
CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUSH BE INSTALLED ON
BOTH SIDES OF METER. BOX.
A- A DRILL 2" Di A. HOLE FOR AMR (AUTOMATIC
METER READ) TOUCHREAD DEVICE
L _ 2-1i/2" MiN. FROM NEAREST
r AND FRONT EDGE OF PIT LID
I
'-TYPICAL
RIB
3/4" OR 1'
GALVANIZED
PLUG
NOTE:
THE CENTER OF THE HOLE MUST BE AT LEAST 1' FROM
UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE
NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN
ONE FIB,
PUBLIC WORKS 3/4" AND 1" WATER SERVICE STD- PLAN - 320-1
« + DEPARTMENT ---
r o NOVEMBER 2009
6" BUILDING SEWER PIPE
TEE WITH 6" SIDE OUTLET
1:3:5 MIX
CONCRETE
BLOCKING
PROPERTY LINE
FUTURE
i BUILDING SEWER
w
�2"x 4" STUD MARKING POST PAINTED
6"X6"X6" WYE WHITE WITH THE WORD "SEWER" STENCILED
SURFACE Cl LNG & COVER WITH
CAST IRON RING IN 3" HIGH BLACK LETTERS AND WIRE
w
WRAPPED AROUND THE STUD AND
(EAST JORDAN IRON WORKS
2975 OR APPROVED EQUAL, EXTENDED TO THE TOP OF THE STUD.
CL SPECIFY "SEWER" ON LID,
SEE STD. PLAN 403A FOR
INSTALLATION)
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN
LINES ARE A5 FOLLOWS:
A. VITRIFIED CLAY MAIN -- CUT IN A NEW SECTION OF SEWER MAIN WITH
A NEW TEE USING FLEXIBLE COUPLINGS
(FERNCO OR APPROVED EQUAL).
B. CONCRETE MAIN - CUT IN A NEW SECTION OF SEWER MAIN WITH
A NEW TEE USING FLEXIBLE COUPLINGS
(FERNCO OR APPROVED EQUAL).
C. PVC MAIN - CORE -DRILLED WiTH A ROMAC SADDLE (OR APPROVED
EQUAL) OR CUT IN A NEW TEE USING RIGID COUPLINGS,
D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR
APPROVED EQUAL)
E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE
AT MANUFACTURED KNOCK -OUTS OR THE
STRUCTURE SHALL BE CORE -DRILLED.
r60" ALLOWABLE MAX,
FOR CAST IRON PIPE
1 OR DUCTILE IRON PIPE. �
` 6" SIDE OUTLET TEE
SEWER
6" MIN. MAIN
QQNCRETE BLOCKING ANGLE
OF TEE_ AT MAIN OVER 25
ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE
A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3--5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
SE10
2X MIN SLOPE
HORIZONTAL
o PUBLIC WORKS STANDARD SIDE SEWER
# ,* DEPARTMENT INSTALLATION
(SEWER WAIN TO PROPERTY LINE)
14--l" , e�4 4
SM. PLAN - 406.1
JANUARY 2013
LENGTH FT'
W 0
50
100
150
2 200
250
® 300
350
as 400
450
6 IN. DIAMETER PIPE
0
561
100
150
200
250
300
350
440
450
500
0
80
160
236
316
396
476
556
632
680
680
140
220
300
380
456
536
616
696
712
708
708
280
360
440
520
600
676
748
744
736
732
728
424
500
580
660
740
780
772
764
756
748
744
564
644
120
800
808
796
788
780
772
764
760
704
784
856
836
820
808
800
1 792
1 784
1 776
772
844
8801
860
844
832
820
508
1 800
792
788
780
S908
908
908
864
888
668
868
872
876
852
856
860
84-0
844
8552
828
836
646
820
824
832
808
816
824
804
808
816
796
804
1 805
788
796
804
TIME (SECONDS)
6 IN. DIAMETER PIPE
LENGTH F
0
50
100
150
200
250
300
350
400
450
500
0
0
80
160
236
316
396
476
556
632
680
880
50
220
300
380
456
536
616
698
768
760
752
744
100
440
520
600
676
756
836
84.0
826
812
804
792
150
660
740
820
896
932
908
888
868
856
840
832
200
860
950
1025
992
964
94-0
920
900
808
872
860
260
1100
1084
1044
11012
988
964
944
928
912
900
888
300
1132
1092
1058
11026
1004
984
1 964
948
932
920
908
350
1132
1096
1068
1040
1016
996
980
964
948
936
924
400
1132
1100
1076
1052
1028
1008
992
976
964
952
940
450
1132 1104 1080 1056 1036
TIME
1020 1004 988 976 964 952
SECONDS
LENGTH Fr
W 0
t= 50
t0O
w 150
200
rs 250
� 300
N 350
400
450
6 IN. DIAMETER
PIPE
0
0
50
80
100
160
150
236
1 200
316
250V471
396
400
632
450
680
500
680
316
632
396
712
476
792
556
872
632
952
712
984
804
908
804
888
792
876
952
1028
1108
1132
1088
1052
972
952
936
1268
1284
1224
1176
1132
1100
1020
1000
984
136d
13001248
1204
1164
1132
1056
1036
1020
1360
1308
1264
1224
1192
1160
1132
1108
1666
1068
1052
1360
1318
1276
1240
1208
1180
1156
1132
1112
1096
1076
13150
132d
1284
1282
1224
1200
1178
1152
1132
11113
1100
1360
132414
1264
1236
1212
1192
1168
1152
1132
1116
TiME SECONDS
6 iN. DIAMETER
PIPE
LENGTH(FT)
0
50
100
150
2DO
250
300
350
400
450
500
uj 0
0
80
160
236
316
396
476
556
632
680
680
ci 50
4-96
576
652
732
812
892
972
948
924
900
884
100
988
1068
1148
1228
1248
1192
1444
1104
1072
1044
1020
150
a 200
1484
1700
1564
1608
1484
1532
1408
1464,
1344
1408
1292
1360
1248
1316
1208
1280&114,081384
1172
1144
6
1116
1192
r`a 250
1700
1624
1560
1504
1452
1408
1368
13322
1248
z 300
170{)
1636
1580
1532
1484
1444
1408
13766
1292
350
1700
1644
1596
1552
1512
1472
1440
14082
1328
" 400
1700
1652
1608
1568
1532
1496
1464
1436
1360
450
1700
1656
1616
1580
1548
1516
1484
14608
1388
TIME
SECONDS
PROCEDURE:
SLOWLY PRESSURIZE THE PIPE TO 4.0 P,S,I.O, ALL SEWER PIPE SHALL MEET A MINIMUM AIR
ALLOW 2 MINUTES FOR STABILIZATION, ADDING PRESSURE TEST OF 00 P,S,I,G. FOR 5 MINUTES
AIR AS REQUIRED TO STABILIZE THE PRESSURE WITH NO LOSS OF PRESSURE. IF THERE IS A LOSS
AT 4.0 P.510, OF PRESSURE, THEN THE TiME OF THE DROP FROM
3.5 P:S.I.O. TO 2,5 P-S.I.G. SHALL NOT RE LESS
THAN THE TIME SHOWN ON THE ABOVE TABLES.
Y
PUBLIC WORKS AIR TEST TABLE STD. PLAN - 410
.* DEPARTMENT ( LOW PRESSURE)
FOR SANITARY SEWERS MARCH 2008
4" SEND AS REQUIRED (NO MORE
THAN 45' BEND), EVERY 2NO
4" CLEANOUT WYE WITH
CHANGE iN DIRECTION OR GRADE
45' BENO AND PLUG.
WiLL REQUIRE A SURFACE
j
CLEANOUT WYE..
j
HOUSE
lu
$ 1
HOUSE
ly
SURFACE CLEANOUT
4" SURFACEE
6;.k, &'x6" WYE
a CLEAN®UT
(SEE STD PLAN
j W
tW CLEANOUT
PROPERTY UNE WYE WITH PLUG
3' MIN.
MAIN SEWER LINE?
IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING
r" FLOW LEVEL RiMS LOCATED BELOW THE ELEVATION
OF THE NEXT UPSTREAM MANHOLE COVER OF THE
v
PUBLIC SEWER SYSTEM A SACKFLOW PREVENTION
EVEN ON
0 ! DEVICE SUCH AS CLEAN CHECK EXTENDABLE
BACKWATER VALVE OR APPROVED EQUAL SHALL BE
W INSTALLED.
\�4!* FLEXIBLE COUPLING (FERNCO OR EQUAL)
SURFACE CLEANOUT
4"X 4"X4" WYE
4" PIPING
ELM
BUILDING DRAIN FOR
LOW ELEVATION HOUSE
MAIN TO PROPERTY LINE F-D" `u 0
PROPERTY LINE FROM THE HOUSE BUILDING DRAIN
SIDE SEWER BUILDING SEWER 2'-6"
3'-0"MIN. I fid 3'_C,•
f
' to -< :9rm C �'ji tlf yte S n x M 4.
V "a m O N C rn I-n > .p Ci Y 7a
ai A:9 8 vj t, P-z 'T9 k. 4Z'} Z X! RI
Z ,..� Ip� as rp+� 1P
W Z % Ja VOA � •�' O C C
91c ycpv
mm I me^z
v 0 to(Asp
U
E
o Q
ALL SO' TURNS SHALL RE ACCOMPLISHES BY MEANS OF A WYE AND 45' SEND. TWO
45• BENDS SHALL NOT BE ACCEPTABLE.
i
W
HOUSE HOUSE
s0" MIN,
4" $EWER PIPE
(TYPICAL)
4" SEWER PIPE, SEE NOTES 2
4" TEST TEE WiTH
AND 3. MINIMUM LINE SIZE FOR
PLUG FACE UP
OTHER THAN SINGLE FAMILY IS 6"
(TYPICAL)
PROPERTY LINE
6"x 4" REDUCER
(TYPICAL)
NOTES
I. Prior to installation of a sanitary sewer connsotion, a side -sewer
permit must be purchased from the City of Renton Public Works
Department..
2. Types of pipe and fittings that can be used for sanitary sewers
shall be approved by the Department of Public Works- Rubber or
neoprene gaskets as specified by the manufacturer, shall be
used on joints.
3, A minimum grade of 2Z (1/4" per foot) must be maintained
with 4" pipe, In the event a 2$ grade cannot be maintained, the
owner must sign a City of Renton grade release form and then
con install 6" pipe at a grade of 1 X
4. For Inspection of side sewer, call 24 noun in advance, The
Inspection phone number is on the side sewer permit. Site
must be ready for Inspection and representative an site whom
Inspector arrives at appointed time. Side sewer and stub shall
be tested per City specifications. Make the connection at the
P Y
house. Do not backfill the ditch until approval Is given by the
Inspector, final approval will be granted after the existing septic
tank has been pumped out and filled with sand.
5. Install side sewer with 2' minimum cover, i6 cover is allowed
at the house If outlet Is shallow.
6, if side sewer stub is not available, The owner ehoii be
responsible for Its Installation per standard drawing 408.1.. All
work within street right-of--woy shall he done by a licensed and
bonded contractor.
7, All work shall be accomplished in accordance with the Washington
Industrial Safety and Health Aot, (WSHA)
6. Al trench restoration for side sewers In the public right-of-way
shall conform to the most current trench restoration
requirements as in the Renton Standard Drawings.
9. Ali building sewer and side sewers shall have bedding in
accordance with standard drawing 405.
10, There shall be a minimum 10 foot horizontal separation between
sanitary side sewers and water services and a minimum 5 fact
horizontal separation between sanitary side sewers and siL other
utilities.
CALL FOR LOCATIONS BEFORE YOU DIG
48HR LOCATORS 1-800-424-5555
1PUBIJC WORKS TYPICAL BUILDIN43 SEWER STD. PLAN -- 408,2
+ori,
*FROM PROPERTY LINE TODEPAk?I'MENT BUILDiNG CONNECTION SEPTEMBE2 2012
SANITARY SEWER NOTES AND SPECIFICATIONS
1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS
AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE
KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CiTY
SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE
PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL
PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK 1NITHIN PUBLIC RIGHT OF
WAY.
3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE ,AND CORRECT LOCATION
SO AS TO AVOID DAMAGE OR DISTURBANCE,
4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED
PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING
CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A, REPRESENTATIVE OF
THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY
THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL
CONSTRUCTION,
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES
OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE
CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND
ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL
TAKE PRECEDENCE OVER ALL OTHER PLANS.
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER
CONSTRUCTION IS IN PROGRESS.
9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING
OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A
LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
% BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A
LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY
TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED
LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO
THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE
THE SAME AS DESCRIBED.
11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED
ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY
COMPACTED UNLESS OTHERWISE APPROVED BY
12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988
METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM
1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC
WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON
THE PLANS.
13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED
TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE
EROSION AFTER THE COMPLETION OF CONSTRUCTION.
14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED
FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE
CITY OF RENTON PLANNINGIBUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST
EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND
MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS &
SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH
BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND
COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE
ENTIRE LENGTH OF THE PiPE WILL BE SUPPORTED ON A UNIFORMLY DENSE,
UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND
BELOW THE PIPE.
15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED
ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY
THE WASTEWATER UTILITY.
16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12
INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE
RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO
MATCH PAVING.
W=382203
S=382202
R=382209
5628 Ai I art Way S 1 PER CiTY REVIEW COMMENTS AMS 7 31 13 MXP SURVEYED: SCALE: DATE:
'�%^' MxP 1988
HORIZONTAL: D196%1991 41 5I 12 2015
Suite i 2 PER CITY REMV COMMENTS AMS 11 1 13 MXP DESIGNED: SEE GRAPHIC .. CITY 0 H ! G H LAN D S PARK SHORT PLAT (U 13001144) FIELDBOOK: /
3 PER CITY RENIM COMMENTS AMS 3/27/14 MXP AMS/MXP _ 6200 SE 2ND PL RENTON WA
Seattle, WA 98108 64 RENTON t PAGE:
DRAWN: WATER & SEWER NOTES & DETAILS
P 206 4.2�-71 �� 4 PER CITY REVIEW COMMENTS TAMS 10 14 MXP TAMS DRAWING No:
� � o ,� /�17V Limit ONE INCH DATUM
206) 457-4469 �, R�rsr>�� Cs 5 PER CI Y REVIEW COMMEN75 AMS Q 20 1S MXP CHECKED: Vn AT FULL SCALE 02� � 1 2
SSI Mx IF NOT ONE INCH Planning/Building/Public Works Dept.
plogC( nsulting.c4m NO. REVISION BY DATE APPI? APPROVED: SCALE ACCORDINGLY SHEET: 9 OF:1 1