SITE BOUNDARY
1
it 1 1 ll /I A/ A TI/l A I 1/' _rl /'%A i A I/1 Trf"`
0INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION
POLE SCHEDULE THIS SHEET SHEET, AND PER CITY OF RENTON STD PLANS 116.1
& 120 ON SHEET 1L2.
D
CONSTRUCT STREET LIGHT CONTACTOR FOUNDATION PER CITY OF RENTON STD PLAN
126.1, SHEET IL3. FOUNDATION SHALL BE ADJACENT TO AND FLUSH WITH
SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN
122.1, SHEET IL2. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET
SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF
CONDUITS.
OASSUMED POWER SOURCE IS EXISTING UTILITY POLE. THE CONTRACTOR SHALL
COORDINATE WITH PSE TO CONFIRM A LOCATION FOR 1201240 VOLT SINGLE PHASE
POWER SOURCE CONNECTION INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND
PAYMENT OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND
CONDUCTORS TO THE POWER SOURCE INCLUDING RISERS ON THE UTILITY POLE IN
ACCORDANCE WITH PSE REQUIREMENTS. PSE SHALL MAKE FINAL CONNECTION TO
THE POWER SOURCE.
SE 1/4, SECTION 14, TOWNSHIP 23 N., RANGE 5 E., W.M.
ILLUMINATION POLE SCHEDULE
LUM.
POLE ID
STREET
STATION *OFFSET
*LATITUDE
**
LONGITUDE **
MOUNT.
VOLTAGE
SERVICE/
WATTAGE
LUMINAIRE TYPE -
BASE
COMMENT
POLE NO.
NUMBER***
HEIGHT
CIRCUIT
TYPE
DISTRIBUTION
O1
160TH AVE SE
18+89.5
22.5' RT
14'
240
ILLUM A
48 LED
PRESTIGE CY17T4-VS3AR-3L3-48W-40OK-
FIXED
NEW POLE PER RENTON STD PLAN 116.1.
240-EA 1-GCY06P-PC-RAL3007TX
2O
160TH AVE SE
21 + 1 1.0
22.5' RT
14'
240
ILLUM A
48 LED
PRESTIGE CY17T4-VS3AR-3L3-48W-40OK-
FIXED
NEW POLE PER RENTON STD PLAN 1 16. 1.
240-EA 1-GCY06P-PC-RAL3007TX
3O
SE 140TH ST
0+31.0
16.5' LT
14'
240
ILLUM A
48 LED
PRESTIGE CY17T4-VS3AR-3L3-48W-40OK-
FIXED
NEW POLE PER RENTON STD PLAN 116.1.
240-EA 1-GCY06P-PC-RAL3007TX
O
SE 140TH ST
1+11.5
16.5' RT
14'
240
ILLUM A
48 LED
PRESTIGE CY17T4-VS3AR-3L3-48W-40OK-
FIXED
NEW POLE PER RENTON STD PLAN 116.1.
240-EA 1-GCY06P-PC-RAL3007TX
5O
SE 140TH ST
1 +70.0
16.5' LT
14'
240
ILLUM A
48 LED
PRESTIGE CY17T4-VS3AR-3L3-48W-40OK-
FIXED
NEW POLE PER RENTON STD PLAN 116.1.
240-EA 1-GCY06P-PC-RAL3007TX
O
SE 140TH ST
2+22.0
16.5' RT
14'
240
ILLUM A
48 LED
PRESTIGE CY17T4-VS3AR-3L3-48W-40OK-
FIXED
NEW POLE PER RENTON STD PLAN 116.1.
240-EA 1-GCY06P-PC-RAL3007TX
7O
HAMMERHEAD
4+81.0
13.5' RT
14'
240
ILLUM A
48 LED
PRESTIGE CY17T4-VS3AR-3L3-48W-40OK-
FIXED
NEW POLE PER RENTON STD PLAN 116.1.
240-EA 1-GCY06P-PC-RAL3007TX
* STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING.
** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS.
*** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR INCORPORATION INTO AS -BUILT PLANS.
4
i
i
i
I 3
i
ILLUIVII/'4/4IIVIV YYIMIIVC7 U1/4L7M A IVI
NOT TO SCALE
N0.
REVISION
T=384601
SURVEYED:
DESIGNED:
TDR
DRAWN:
TDR
CHECKED:
GMD
BY DATE APPR APPROVED:
CTB
ILLUMINATION WIRING SCHEDULE
0
RACEWAY
CONDUIT
SIZE
ILLUM.
#8
SERVICE
#2
EQUIP.
GRIND.
PULL
WIRE
NO.
1
2" SCH40 PVC
2
1
2" SCH80 PVC
2
1
2
2" SCH80 PVC SPARE
1
3
2" SCH80 PVC
3
1
4
3" SCH40 PVC
2
1
5
2" SCH80 PVC
2
1
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE
LARGEST WIRE SIZE IN THE CONDUIT.
GENERAL NOTES
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE
LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING
CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN
WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC
WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE.
3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND
CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555.
4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A
REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE
OF BACKFILLING ALL CONSTRUCTION.
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS
ON THE CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR.
10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL A MINIMUM OF 3 WEEKS
PRIOR TO REQUIRED APPROVAL.
11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR
SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE
OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM
THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT
CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY
BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED.
12. THE LOCATION OF FEATURES SHOWN SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR WITH TRANSPORTATION
MAINTENANCE DEPARTMENT SUPERVISOR ERIC CUTSHALL AT (425) 430-7423. '
ILLUMINATION LEGEND
NEW
DESCRIPTION
m 0
JUNCTION BOX TYPE 1,2
PEDESTRIAN LUMINAIRE
- - - - -
CONDUIT/CONDUCTOR
®
SERVICE CABINET
O
CONSTRUCTION NOTE
OLUMINAIRE
POLE NO.
AWIRE
NOTE
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date
Date
Date
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL NAVD 1988
HORIZONTAL: NAD/983/1991
DATU M
SERVICE 1 BREAKER SCHEDULE
CIRCUIT
BREAKER
CONTACTOR
MAIN
2P-100 AMP
---
ILLUM A
2P-20 AMP
30 AMP
RECOMMENDED
FOR APPROVAL
BY
RY
BY
CITY OF
RENTON
Planning/Building/Public Works Dept.
20
GRAPHIC SCALE
0 10 20 40
( IN FEET )
1 inch = 20 ft.
19TENW
80
Transportation Engineering NorthWest
Transportation Planning I Design I Traffic Impact & Operations
11400 SE 8th Street, Suite 200, Bellevue, WA 98004
Office (425) 889-6747
Project Contact: Glen DuBreuil
Phone: 425-250-0582
DATE:
May 10, 2016
M I N D Y' S PLACE FIELDBOOK:
PAGE:
DRAWING NO:
ILLUMINATION PLAN 4921
SHEET: OF:
1 3
ef
Cm
= C <
c
z
z =
CD
C
M
_ CD IT1
Nz
m
z
m
M
0
D
I D
0
O
C
_o�
"M
R {
T D
� T
z�
m o
�MM
m
T m-
U:
lv z
z
m
0
D
D
^z^
UJ
c
K
co
M
11
�Nd
�a
rn�
1
00MMW
I
D
T
0
a
a 0D
0
o�C G
o m
Co 7 3'8(�'60/