Loading...
HomeMy WebLinkAboutTRO4103846.20 n 0 z w Q Z F- 0 Ld 0 n E i 1 e i�Ei E r �l f 1 f 1. 3 SITE BOUNDARY 1 1 2 II 1 Ili A 1 1 SE 140TH ST R L LJ j([ 4 1 1 STA. 19+01.0, 23.0' RT 2 1 4 Mw SITE BOaNDARY 1 1 rj rA- 1 1 EX I t ILLUMINATION CONSTRUCTION NOTES 1 INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE THIS SHEET SHEET, AND PER CITY OF RENTON STD PLANS 116.1 & 120 ON SHEET IL2. (CONSTRUCT STREET LIGHT CONTACTOR FOUNDATION PER CITY OF RENTON STD ';PLAN /� J 126.1, SHEET IL3. FOUNDATION SHALL BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1, SHEET IL2. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. OASSUMED POWER SOURCE IS EXISTING UTILITY POLE. THE CONTRACTOR SHALL COORDINATE WITH PSE TO CONFIRM A LOCATION FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE POWER SOURCE INCLUDING RISERS ON THE UTILITY POLE IN ACCORDANCE WITH PSE REQUIREMENTS. PSE SHALL MAKE FINAL CONNECTION TO THE POWER SOURCE. SE 1/4, SECTION 14, TOWNSHIP 23 N., RANGE 5 E., W.M. ILLUMINATION POLE SCHEDULE LUM. POLE ID STREET STATION * OFFSET *LATITUDE ** LONGITUDE ** MOUNT. VOLTAGE SERVICE/ WATTAGE LUMINAIRE TYPE - BASE COMMENT POLE NO. NUMBER*** HEIGHT CIRCUIT TYPE DISTRIBUTION t� 4768A48 160TH AVE SE 18+89.5 22.5' RT 47-28-36.3109 -122-07-36.7488 14' 240 ILLUM A 48 LED PRESTIGE CY17T4-VS3AR-3L3-48W-40OK- FIXED NEW POLE PER RENTON STD PLAN 116.1. 240-EA1-GCY06P-PC-RAL3007TX O 4769A48 160TH AVE SE 21 +11.0 22.5' RT 47-28-38.4897 -122-07-36.7804 14' 240 ILLUM A 48 LED PRESTIGE CY17T4-VS3AR-3L3-48W-40OK- FIXED NEW POLE PER RENTON STD PLAN 116.1. 240-EA 1 -GCY06P-PC-RAL3007TX O 4770A48 SE 140TH ST 0+31.0 16.5' LT 47-28-37.5521 -122-07-36.6524 14' 240 ILLUM A 48 LED PRESTIGE CY17T4-VS3AR-3L3-48W-40OK- FIXED NEW POLE PER RENTON STD PLAN 116.1. 240-EA 1-GCY06P-PC-RAL3007TX 4771 A48 SE 140TH ST 1 + 1 1.5 16.5' RT 47-28-37.2119 -122-07-35.4868 14' 240 ILLUM A 48 LED PRESTIGE CY17T4-VS3AR-3L3-48W-40OK- FIXED NEW POLE PER RENTON STD PLAN 116.1. 240-EA 1-GCY06P-PC-RAL3007TX 0 4772A48 SE 140TH ST 1 +70.0 16.5' LT 47-28-37.5428 -122-07-34.6113 14' 240 ILLUM A 48 LED PRESTIGE CY17T4-VS3AR-3L3-48W-40OK- FIXED NEW POLE PER RENTON STD PLAN 116.1. 240-EA 1-GCY06P-PC-RAL3007TX Q 4773A48 SE 140TH ST 2+22.0 16.5' RT 47-28-37.2028 -122-07-33.8256 14' 240 ILLUM A 48 LED PRESTIGE CY17T4-VS3AR-3L3-48W-40OK- FIXED NEW POLE PER RENTON STD PLAN 116.1. 240-EA 1-.GCY06P-PC-RAL3007TX 7O 4774A48 THAMMERHEAD 4+81.0 13.5' RT 47-28-36.0519 -122-07-33.4156 14' 240 ILLUM A 48 LED PRESTIGE CY17T4-VS3AR-3L3-48W-400K- FIXED NEW POLE PER RENTON STD PLAN 116.1. 240-EA 1-GCY06P-PC-RAL3007TX * STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIUR 1U IMVLLMLNIING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR INCORPORATION INTO AS -BUILT PLANS. I E i � } } 1 i 3 F Lt 1 5 I i 1 6 ILLUMINATION. WIRING DIAGRAM i 2 Lit 3 5 SE 140TH ST o � Q I� 2 SERVICE 7 _ILLUM AAA i NOT TO SCALE M 1 3 t" M v... ..�- .f i I I II I 1FAFA 1 1 1 SURVEYED: DESIGNED: TDR DRAWN: TDR CHECKED: GMD REVISION BY DATE APPR APPROVED: CTB ILLUMINATION WIRING SCHEDULE 0 RACEWAY CONDUIT SIZE ILLUM. #8 SERVICE #2 EQUIP. GRND. PULL WIRE N0: 1 2" SCH40 PVC 2 1 2" SCH80 PVC 2 1 2 2" SCH80 PVC SPARE 1 3 2" SCH80 PVC 3 1 4 3" SCH40 PVC 2 1 5 2" SCH80 PVC 2 1 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE :SIZE IN THE CONDUIT. GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3.30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DA04AGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR. 10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL A MINIMUM OF 3 WEEKS PRIOR TO REQUIRED APPROVAL. 11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 12. THE LOCATION OF FEATURES SHOWN SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR WITH TRANSPORTATION MAINTENANCE DEPARTMENT SUPERVISOR ERIC CUTSHALL AT (425) 430-7423. ' ILLUMINATION LEGEND NEW DESCRIPTION m 0 JUNCTION BOX TYPE 1,.92 PEDESTRIAN LUMINAIRE - - - - - CONDUIT/CONDUCTOR ® SERVICE CABINET O CONSTRUCTION NOTE 0 LUMINAIRE POLE NO. AWIRE NOTE CHECKED FOR COMPLIANCE 30. CITY STANDARDS Date Date Date SCALE: VERTICAL: NAVD 1988 AS SHOWN HORIZONTAL NAD 1983/1991 ONE INCHDATUM AT FULL SCACA LE IF NOT ONE INCH SCALE ACCORDINGLY SERVICE 1 BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P-100 AMP --- ILLUM A 2P-20 AMP 30 AMP T=384604 RECOMMENDED FOR APPROVAL BY BY BY t 41 M "'R CITY OF ML RENTON Planning/Building/Public Works Dept. 20 c�h Asy�y�'v/C'�I GRAPHIC SCALE 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. %9TENW 80 Transportation Engineering NorthWest 2 7y,1 ,.� Transportation Planning I Design I Traffic Impact & Operations v� H 400 SE 8th Street, Suite 200, Bellevue, WA 98004 ..... � Office (425) 889-6747 Project Contact: Glen DuBreuil ®® Phone: 425-250-0582 __.... DATE May 10, 2016 MINDY'S PLACE RELDBOOK: PAGE: DRAVANG NO: ILLUMINATION PLAN 4921 SHEEr: OF: 1 3 n lu z D azm ��� z Imo c 5 :D E M- Cil N z ITT z z Lr) 0 D D C T o� gDo c €:0 �W� D �Dm Cz me 5 M rr -p ET7 5 N� z m Cn 0 D Ill'-q Pd 0 ~ ' t7 NCN nor, 1 i 00 D o � M0 � ° D ;moo ,on �m� � f1� �W �