HomeMy WebLinkAboutTRO4103847.7C19
o
o
°
ILLUMINATION GENERAL NOTES
w
z
°
J
1.
ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY
N
a
W
N
DEPARTMENT CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF
SERVICE
I BREAKER SCHEDULE
2.
APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION.
THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS
CIRCUIT
BREAKER CONTACTOR
0
0
OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE
Ln
APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911
MAIN
2P-200 AMP
SHALL BE NOTIFIED 24 HOURS IN ADVANCE.
ILLUM A
2P-20 AMP 30 AMP
Z
'
3.
ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
ILLUM B
2P-20 AMP 30 AMP
J
Z
VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR
LOCATORS, 1-800-424-5555.
ILLUM C
2P-20 AMP 30 AMP
~
Z _l
Z
4.
A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT
ILLUM D SPARE
(SPARE)
2P-20 AMP 30 AMP
O Q
W
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION.
SIGNAL
2P-20 AMP 30 AMP
a:
(INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S
ZWQ
RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
Z
D
W
5.
CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF
�
WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
SERVICE
2 BREAKER SCHEDULE
Z
J Z
Q
J
6.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY
CIRCUIT
BREAKER CONTACTOR
00
0
J
CONSTRUCTION.
W W
MAIN
2P-200 AMP ---
z
Q
�
7.
PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
m
W
ILLUM A
2P-20 AMP 30 AMP
I— Z
8.
A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
Z
0
ILLUM B
2P-20 AMP 30 AMP
O
LLJ
�
9.
ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR.
ILLUM C
2P-20 AMP 30 AMP
�
U-
Q
10.
THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL
ILLUM D (SPARE)
2P-20 AMP 30 AMP
w
MINIMUM 3 WEEKS PRIOR TO THE DESIRED APPROVAL DATE.
11.
AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD
a
POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE
Cn
PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE
CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES.
ILLUMINATION WIRING DIAGRAM
ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD
w
Q
POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS
a
o
DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED.
ui a
0
12.
CONTRACTOR SHALL RESTORE ALL GROUNDS DISTURBED BY CONDUIT AND ILLUMINATION SYSTEM INSTALLATION, INCLUDING BUT NOT
9
O
0
LIMITED TO: LANDSCAPING, IRRIGATION, CONCRETE SIDEWALKS, ETC.
RJ RI RH RG
13.
EXISTING ILLUMINATION SYSTEM SHALL REMAIN OPERATIONAL UNTIL SUCH TIME THAT NEW ILLUMINATION SYSTEM IS OPERATIONAL.
CIRCUIT
[�
Do
MAXIMUM DOWN TIME FOR SWITCHOVER TO THE NEW SYSTEM SHALL BE 24 HOURS.
CONTINUES ON
TO EX SERVICE CABINET
W
p—�In
SW 41 ST ST
SW 4 I ST ST
AT SE CORNER OF SW41
ST ST AND
ILLUMINATION CONSTRUCTION NOTES
- LINO AVE SW
w
u
a
N
m
O
INSTALL FOUNDATION, POLE, TWO LUMINAIRES, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL 1.06, AND PER CITY
L2 LV 0 LU L1 LT 1410 (LSL1 LR 10 LQ
1
o
��
0)
OF RENTON STANDARD PLANS 1 17.1, 1 17.3, 119, 120, 121, & J013.-
aFI
1-1
2
INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL1.06, AND PER CITY OF
LP
�)
RENTON STANDARD PLANS 117.2, 117.3, 119, 120, & 121 & J013.
SERVICE 2
�)
INSTALL FOUNDATION AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL1.06, AND PER CITY OF RENTON STANDARD
ILLUM A
LO
O3
PLANS 115, 119, 120, 121 & J013 AND WSDOT STANDARD PLAN J-28.30. RELOCATE EXISTING ILLUMINATION POLE TO NEW
FOUNDATION. CONTRACTOR SHALL VERIFY BOLT PATTER PRIOR TO POURING FOUNDATION.
ILLUM B
1 )
�
ILLUM C
a
a� Q
4O
INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL1.06, AND PER CITY OF
ILLUM D SPAR
>
o
RENTON STANDARD PLANS 1 17.1, 1 7.3, 119, 120, 112/1, & J013.
LN )
\1
\
POWER SOURCE CONNECTION POINT UNKNOWN AT THE TIME OF PLAN PREPARATION. CONTRACTOR SHALL ASSUME APPROXIMATELY
5
500 FEET OF TRENCHING TO POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO
1 �)
PROVIDE 1201240 VOLT SINGLE PHASE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE'S TRANSPORTATION'S MAINT.
}
U J
ASST. MANAGER (FRIG CUTSHALL) AT 425-430-7423 FOR SERVICE CABINET ELECTRICAL HOOK-UP, SHALL PREPARE/SUBMIT ALL i
LM j
w
o
APPLICABLE PERMITS, AND SHALL PAY A/ ALL FEES.
Z
N Z O
^ASSOOCIATED
W
o
J O U
1 Z W
6
O
CONSTRUCT STREET LIGHT CONTACTOR FOUNDATION PER CITY OF RENTON STD PLANS 126.1 AND 126.2. FURNISH AND INSTALL
1 z RF
a
N
SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE
--
N
VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS.
N
J
LL
SHALL FURNISH AND INSTALL ALL CONDUIT AND CONDUCTORS TO THE POWER SOURCE. POWER SOURCE FOR NEW
OCONTRACTOR
SERVICE CABINET SHALL BE FROM THE SAME SOURCE THE EXISTING%REMOVED SERVICE CABINET DRAWS POWER FROM. CONTRACTOR
SERVICE 1
L1
SHALL LEAVE SUFFICIENT SLACK IN CONDUCTOR FOR FINAL CONNECTION. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE
CABINET ELECTRICAL HOOK-UP, SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES.
NOT TO SCALE ILLUM A
OREMOVE
EXISTING SERVICE CABINET AND FOUNDATION. FILL AND COMPACT VOID.
ILLUM B
ILLUM C
LK
RE
0
0
w 0
0
8
EXISTING TYPE III SIGNAL STANDARD. REMOVE EXISTING FOUNDATION TO A MINIMUM OF 24" BELOW FINISH GRADE. RETURN
ILLUM D
1
(D
SALVAGED POLE TO THE CITY OF RENTON.
SALVAGED
SIGNAL
m
T5c-n
a_
10
SPLICE NEW ILLUMINATION CONDUCTORS TO EXISTING ILLUMINATION CONDUCTORS IN EXISTING JUNCTION BOX PER CITY OF RENTON
[,d-� LJ
�
Q
STANDARD PLAN J013.
7_7
� � � �
_
Q
co
00
Q0
M
z
O
Cn
w
of
Cn
0
N r7 z
O O O Q
z z z
0
z z z o
O O O
O
> > > U
w w w w
mll� 00f m
11 INTERCEPT AND EXTEND EXISTING CONDUIT TO NEW JUNCTION BOX. SPLICE NEW ILLUMINATION CONDUCTORS TO EXISTING
ILLUMINATION CONDUCTORS PER CITY OF RENTON STANDARD PLAN J013.
12 REMOVE EXISTING JUNCTION BOX. REPLACE WITH NEW TRAFFIC BEARING JUNCTION BOX TYPE 4 PER WSDOT STANDARD PLAN
J-40.20-02. JUNCTION BOX SHALL HAVE SKID RESISTANT LID.
O13 RELOCATE EXISTING STREET LIGHT POLE, ARM AND LUMINAIRE TO NEW FOUNDATION AT LOCATION SHOWN. REMOVE EXISTING
FOUNDATION TO A MINIMUM OF 24" BELOW FINISH GRADE. FILL AND COMPACT VOID.
14 RELOCATE EXISTING STREET LIGHT POLE, ARM AND LUMINAIRE TO NEW FOUNDATION ON SW 43RD STREET (SEE POLE ID 'RB', STA.
29+51.5, 34.0' RT). REMOVE FOUNDATION. FILL AND COMPACT VOID. SEE ILLUMINATION CONSTRUCTION NOTE 19.
15 REMOVE EXISTING JUNCTION BOX. FILL AND COMPACT VOID.
16
REMOVE
EXISTING
JUNCTION BOX
AND CONCRETE PAD. FILL AND COMPACT VOIDS.
17
REMOVE
EXISTING
CONDUCTORS.
ABANDON EXISTING CONDUIT.
18
EXISTING
STREET
LIGHT POLE TO
REMAIN. PROTECT DURING CONSTRUCTION.
19
RELOCATED FROM
LIND AVE SW.
SEE ILLUMINATION CONSTRUCTION NOTE 14.
20
EXISTING
SERVICE
CABINET TO REMAIN.
PROTECT DURING CONSTRUCTION.
CALL 2 WORKING DAYS
BEFORE YOU DIG:
811
VERTICAL DATUM:
CITY OF RENTON, NAVD 88
Approved by:
BENCHMARK:
CITY OF RENTON CONTROL Approved by:
POINT NO. 1864 WAS HELD
BEING Approved by:
FOR ELEVATION,
19.488 FEET (NAVD88) jApproved by:
TO SERVICE CABINET
AT SE CORNER OF
SW 43RD ST AND
80TH AVE S
SW 43RD ST
RA RB RC RD
u u u
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date
Date
Date
Date
r ?\AER T
wawl �
O�.•l'- 3563 �O
�ONAL•� d'
p9
IKEA PROPERTY INC
420 ALAN WOOD ROAD
CONSHOHOCKEN, PA 19428
CONTACT: DWIGHT E. SLATON
CONSTRUCTION MANAGER
P: (610) 834-0180; C: 303-549-4623
E: DWIGHT.SLATONOIKEA.COM
ENGINEER:
TRANSPORTATION ENGINEERING NORTHWEST
11400 SE 8TH STREET, SUITE 200
BELLEVUE, WA 98004
CONTACT: GLEN DuBREUIL
P: (425) 250-0582; C: (206) 295-6776
E: DUBREUIL®TENW.COM
CIRCUIT
CONTINUES ON
SW 43RD ST
T=384718
CITY OF RENTON
L7EPAF=tTMI=N-' OF PUBLIC WORKS
FRONTAGE ILLUMINATION PLAN
NOTES AND DETAILS
R-G) T E N W IKEA REDEVELOPMENT, RENTON, WA.
Transportation Engineering NorthWest DESKNED TDR
Transportation Planning I Desigr 1 Traffic Impact &Operations DATE 09/21 Z201 7 FILE No. U 15001266
DRAWN TDR
CHECKED GMD SCALE FELD BOOK PACE_
APPROVED
DIRECTOR OF PUBLIC WORKS mm7 OF 10
�z
Z
e
m
O
n
(P
W
!U z
MT
Ill
M
Cn
0
Cn
D
C]
0
o0
„o
c
D170 cd
D
�m
MO
Dm
m-
u�
z
m
0
V
M
G
Z
G)
Z
9
co
M
III
x�C
�b
w
C7
co
D
o
°0
D
D�
m
z>•
A
P1