Loading...
HomeMy WebLinkAboutTRO4103895.1MATCH LINE STA 100+00 SEE BELOW RIGHT SEC. 11, TWP. 23 N, RGE. 5 E., W.M. z m z i 'z m m O D NE 6TH PL bU+UU 0 + 3 o x L�1 a ILLUMINATION WIRING SCHEDULE l� NO. RACEWAY CONDUIT SIZE ILLUM. #8 SERVICE #2 EQUIP. GRND. PULL WIRE 1 2" SCH40 PVC 2 1 2" SCH80 PVC 2 1 2 2" SCH80 PVC SPARE 1 3 3" SCH80 PVC 3 2" SCH40 PVC 2 1 4 2" SCH40 PVC SPARE 1 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. CD MATCH LINE STA 100+00 SEE ABOVE LEFT ILLUMINATION CONSTRUCTION NOTES DINSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND PER CITY OF RENTON STANDARD PLANS 116.1, 119, 120, 121, 123, 125 & J013 ON SHEETS IL-03 AND IL-04. OCONSTRUCT STREET LIGHT CONTACTOR FOUNDATION PER CITY OF RENTON STD PLAN 126.1, SHEET IL-04. FOUNDATION SHALL BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STANDARD PLAN 122.1, SHEET IL-03. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. OTHE POWER SOURCE LOCATION WAS NOT KNOWN AT THE TIME OF PLAN PREPARATION. THE CONTRACTOR SHALL COORDINATE WITH PSE TO IDENTIFY A LOCATION FOR 1201240 VOLT SINGLE PHASE POWER SOURCE CONNECTION INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT OF ALL ASSOCIATED FEES. THE CONTRACTOR SHALL INSTALL CONDUIT AND CONDUCTORS TO THE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE THROUGH ERIC CUTSHALL, CITY OF REDMOND TRANSPORTATION MAINTENANCE ASSISTANT MANAGER, PHONE NUMBER 425-430-7423, FOR SERVICE CONNECTION. PSE SHALL MAKE FINAL CONNECTION TO THE POWER SOURCE. THE CONTRACTOR SHALL ASSUME 500' FEET OF TRENCHING TO CONNECT TO POWER SOURCE FOR BIDDING PURPOSES. LABEL CONTACTOR CABINET WITH ADDRESS LOCATION FOLLOWING CITY OF RENTON STANDARD PLAN 122.1, DATED 0112612015. O4 EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. 5 INSTALL TYPE II JUNCTION BOX WITH CONCRETE PAD PER CITY OF RENTON STANDARD --Ss O PLAN 125. TARGET CALCULATION SUMMARY ACTUAL DESIGN CRITERIA CALCULATION UNIFORMITY AREA AVG. MAINTAINED RA AVG. T O C FOOT CANDLES MIN. INT. NILE AVE NE & ROAD A 1.20 4.00:1 (COLLECTOR ARTERIAL) 1.20 3.00:1 NILE AVE NE (NORTH) 0.90 4.00:1 (COLLECTOR ARTERIAL) 1.58 3.95:1 NILE AVE NE (SOUTH) 0.90 �1.59 4.00:1 (COLLECTOR ARTERIAL) 3.98:1 SIDEWALK NORTH 0.30 6.00:1 (RESIDENTIAL) 0.41 4.10:1 SIDEWALK SOUTH 0.30 (RESIDENTIAL) 0.54 7��2.70:1 LEGEND EX NEW/RELOCATE DESCRIPTION 8 0 JUNCTION BOX TYPE 1,2 PEDESTRIAN LUMINAIRE POLE UTILITY POLE UTILITY POLE MOUNTED LUMINAIRE — — — CONDUIT/CONDUCTOR ® ELECTRICAL SERVICE CABINET OCONSTRUCTION NOTE OLUMINAIRE POLE NO./LETTER AWIRE NOTE T=389501 10 40 0 20 60 SCALE IN FEET & j �6 CITY OF RENTON COMPLIANCE WITH CITY OF RENTON STANDARDS By: G Date: By: Know what's below. Call before you dig. By: Date: Date: av'o�ay� %-D o 30 i H.O O y•:v- 0 3 0� 0 od 0 03 Z co 0) >� co ` a� o Z m ~ D 00 N L1J I N U N w ON I Q) U p �a o o 0 CL� o o w L Q- o `n o ILN o 0- 0 N O w U) L0 U W O O J >co rn ~ w on m I II w rn = w D z Y > 00 O Q w .--, I— J J Ln cn J 'S m � W T z CD i J z 0 Q Q U) D m n 0 M no 0 �M D Ul 3�7 D • D �Z Em � �o D m � m Nz z m O 0=3 G d o� z z m .P -0 Vy�� Z > W ImO 0 > m !> • r- v : I - 38g5 a U 15— 006162