Loading...
HomeMy WebLinkAboutWWP2703900.1000 0 0 0 0 ILI J I MANHOLE FRAME AND COVER PER DRAWING 401. ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 MORTAR JOINT(S) (3/8" MIN.)-� SEE NOTE 5 4" MIN. TO c •a °. 12" MAX. 24,. xQ in IF I o � 12" ° N o J� m m Z o. C � > N 4" v vv F''' ° 6" a ° NOTES: 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING SHALL BE PER STD. PLAN 401. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. 6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITEp_ 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. B. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443, 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE. 10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. 11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. PUBLIC WORKS SANITARY MANHOLSTD E• PLAN - 400.2 DEPARTMENT SHALLOW �N.tO SEPTEMBER 2011 BOLTHOLES - 3 PILLSEQUALLY SPACED 120' APART ON 23 1/16' (566MM) DIA B.C. (SEE DETAIL) r >a RENTON SEWER � Q COVER & FRAME PLAN VIEW h_ 25' DIA. [635MM] _I 1' 3 m' r I n] C19r1mr1] 8 3/4' L 2 1/2, 1222MM] 164Mr)J TYP COVER SECTION VIEW COVER BOTTOM VIEW BLT SOC, (ALLEN HEAD) 5/8'-11 X 1.5 SS RUBBER WASHER EON BOLTING DETAIL 26 1/2' DIA L673mml 25 1/4' DIA [641nM1 1 1/16' 1/4' 1 1/16' 1/4' (6MM) WA LL27mml A- 6 C152mmlC27MM] NEOPRENE GASKET 5/8' 23 3/8' DIA CL ❑PEN 116Mnl C594r1rI GASKET GROOVE DETAIL 27 5/16' C694mmi 34 1/8' DIA L867mm] NOTES: FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. USE FRAME AND COVER FOR STORM (SPECIFY 'DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). l�Y\O STD. PLAN - 401 1� PUBLIC WORKS MANHOLE FRAME AND COVER DEPARTMENT DECEMBER 2008 Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) FA NE 1/4 SECTION 23, TOWNSHIP 23 N, RANGE 5 E, W.M. ALPINE NURSERY MANHOLE FRAME AND COVER SEE STD. PLAN 401 ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 MORTAR JOINT(S) (3/8" MIN.) SEE NOTE 5 CONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE - 'E' CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. 4. jB,� '.. .'..:.• I NOT TO SCALE 'A' 1 'B' 1 'C' I V I_ 'E' 48" MH 48" 6" MIN. 5"MIN 24" MIN. 1 21" I.D. 54" MH 54" 8" MIN. 5.5" MIN. 24" MIN. 24" LD. 60" MH 60" 8" MIN. 6" MIN, 42" MIN. 30" I.D. NOTES: 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING SHALL BE PER STD. PLAN 401. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. 6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING 9 � I BOND OR 1/2 BOND, THE USE OF SHIMS IS PROHIBITED 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC--AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE- 10 . CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. 11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. STD. PLAN - 400.1 PUBLIC WORKS STANDARD SANITARY MANHOLE DEPARTMENT SEPTEMBER 201i W (SEE NOTE 7) LIMITS OF PIPE ZONE 1' I U„ BEDDING MATERIAL FOR SANITARY SEWER PIPE O.D. OF PIPE (SEE NOTE 5) FOUNDATION LEVEL BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)' OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 .� PUBLIC WORKS PIPE BEDDING sly DEPARTMENT FOR SANITARY SEWERS 7AWW4 1*0 w�aww DATE r L[EF 0 D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 7THAVENUE, KIRKLAND, WA 98033 O 425, 827, 3063 F 425, 827.2423 TO SS 2" PVC �.. (TYP.) PLAN VIEW SEWER C/O 2" POLY (TYP.) SANITARY SEWER CIO 8" PVC PLUG 8" PVC SEWER MAIN SIDE SEWER FORCE MAIN CONNECTION DETAIL EX. SEWER MAIN L _ _PROPERTY LINE _SPOOL (LENGTH AS NEEDED) ? i >E b I 3 0„ 8" SEWER STUBE FUTURE 4" SIDE SEWER `\ / ` 2"x 4" STUD MARKING POST PAINTED `SEWER MAIN TEE X 6" TEE I 6" CAPJ WHITE WITH THE WORD "SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND #6 WIRE WRAPPED AROUND THE STUD AND EXTENDED TO THE TOP OF THE STUD, try COUPLING (TIP,) 31 - 8-X6"X8" SURFACE CLEANOUT WITH CAST IRON RING AND COVER z� I (EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR 52 : APPROVED EQUAL, SPECIFY "SEWER" ON LID), (SEE STD. PLAN 403.1 FOR INSTALLATION) I --•---------------------- -- JM EAGLE THREADED CLEAN -OUT ADAPTER HUB BEND AS & PLUG (OR APPROVED EQUAL) REQUIRED EXISTING SANITARY _� SEWER MAIN .0% IN, SLOPE \ 1 ` FUTURE 4" SIDE SEWER ( `S" SEWER STUB 6"XB"XB' WYE `FUTURE 6"x 4" REDUCER \`SEWER MAIN SIZE X 8" TEE ACCEPTABLE PROEWER --CONAEGTI0N9 TO EXISTING-154WER MAR A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). C. PVC k C900 PVC MAIN CUT IN NEW TEE USING RICID COUPLNGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. Do 3000 CON C E EIX BLOCKING 5 X• 0� N ti /' GOB p� 2! A11N SL QPE J_ _. 8" TEE HORIZONTAL fi" MIN. SEWER SEWER MAIN MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN BETWEEN 25' AND 43• TYPICAL SIDE SEVrER NOTE • UNLESS OTHERWISE_ SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. - STANDARD SIDE SEWER STD. PLAN -406.1 ♦ PUBLIC WORKS INSTALLATION A DEPARTMENT 11130 (SEWER MAIN TO PROPERTY LINE) Wk VMN ,AT 1 CITY COMMENTS, REVIEW 1 2 CITY COMMENTS, REVIEW 2 3 1 MYLARS N0. REVISION MAJ 03.03.16 MAJ SURVEYED: sJs MAJ 05.23.16 107.28.161 MAJ DESIGNED: YLP MAJ MAJ DRAWN: CHECKED: MAJ BY DA i E AP P R APPROVED: MAJ 1.50' CLEARANCE 2.00q MIN. 3 0 O W 8' PLANTER 5' CEMENT 6 CONCRETE MIN. SIDEWALK TYP. 24"LCPE SO IE 362.18 (P3) 2.00% MIN. 15' _ 11.25' BEND 8" SS /E 359.78 LOT 26 SEWER STUB DETAIL NTS LQ Lki O 2 O �Io W a 8' PLANTER 5' CEMENT Z 6 CONCRETE v O MIN. SIDEWALK TYP. 24"LCPE SO IE 362.07 (P3) 1.50' CLEARANCE ZOO MIN. 2.00% MIN. CLEANOUT PER STANDARD PLAN 403.1 FIG 371.50 END /E 364.50 CLEANOUT PER STANDARD PLAN 403.1 FG 370.50 1.G7 LICIVL/ 8 " SS /E 359.62 LOT 27 SEWER STUB DETAIL NTS SA NI TAR Y SEWER NO TES AND SPECIFICA TIONS: wRECESSED Not to Scale LIFT POCKET FRAME e 3/4" LETTERING "SEWER" 2-O' DIAMETER 2'-0" (2) BOLT SOD. (ALLEN HEAD) 5/B" - 11 X 1.5 STAINLESS STEELREF. PART #00981177T 1-3, 4 8" CLASS "B" SAND OR ASPHALT 5/r" EXPANDABLE 12-1/2" ' r ' T1_1/8. 2-1/4" 14" i-=-12-3/4"____ 11 I 11 II 12-1 /4'� CAST IRON RING AND COVER BOLT DETAIL 45' (1/5) BEND 410 45- (1/8) BEND FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES: 1. 8" AND 5" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. No. 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS, POUR A 1'-0- THICK, 2'-0- SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER, STD. PLAN - 403.1 �♦® PUBLIC WORKS 8" OR 6" CLEANOUT UPRO`ED: aim DEPARTMENT FOR SANITARY SEWER MAIN rwk w, w," �0 E SCALE AS NOTED ONE INCH AT FULL SCALE 1 IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 Adt� DATUM END IE 364.10 1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDINGIPUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCAT70N SO AS TO AVOID DAMAGE OR DISTURBANCE. 4, A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR /S SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 10. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 17. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKF/LLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. 12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 198311991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON /N THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. }: C TY OF RENTON Planning/Building/Public Works Dept. S=3900 10 RECOMMENDED FOR APPOVAL BY: Date: Date: 4 BY: Date: BY: Date: ALPINE NURSERY SEWER NOTES AND DETAILS U15007366 DRS PROJECT NO. 14069 A - c0 o S-3100/0 DATE: 09.28.15 FIELDBOOK: PAGE: DRAWING NO: SS10 SHEET: OF: 40 42 NINININIA7A L O Z V / z ED = C D O F mm Iz W z m (n O D D O 0 D O a � : Cn m m 17, 0 m K 2 z m O m D z C W m 0 N W c/] trJ A D V/ (D o N o4-C Cn � M t=7 f r L1 C m D T ° 30 30 m ° ° D o c ° (n z 'n z