HomeMy WebLinkAboutTED4003904.7D � lJ, m Z= z I c mo �� m- CP Nz m 7 T CONCRETE WING WALL TO NORTH PLACE 6-INCH LAYER CLEAN SAND -GRAVEL OVER PROPOSED SEDIMENT SURFACE PER SHEET C2 AND SPECIFICATIONS EL -1 1.5' EL -28.5' RAIL TRACKS TYPICAL ANNUAL WATER ELEVATION IS BELOW ABOUT 10' TYPICAL SUMMER WATER ELEVATION IS BELOW ABOUT 8'7 TRASH RACK i _- — — EXISTING SEDIMENT SURFACE, SEE NOTE 1 - — — PROPOSED SEDIMENT SURFACE EL. —4.56 CONCRETE BOTTOM OF FOREBAY (SEE NOTE 3) SEDIMENT REMOVAL ZONE A kl w a ry 0 co 0 N 0 Q 0 0 V U 00 FIELD BOOK: o SURVEYED: EL -16' STOP LOG SLOT - EL. -11.56 SEDIMENT REMOVAL —� ZONE B PUMP STATION EL —9.5' WESTERN EXTENT OF SURVEY NOTES: 1) EXISTING SEDIMENT SURFACE IS BASED ON 2011 BATHYMETRIC SURVEY, PER THE SURVEY NOTES. SEDIMENT SURFACE WEST OF SURVEY LIMITS IS ESTIMATED BASED ON AVERAGE DEPTH OF SEDIMENT AT RAIL TRACK. 2) EXISTING AND PROPOSED SEDIMENT SURFACES AND CONCRETE APRON APPROXIMATELY TO SCALE (1 "=40' FULL SIZE). STRUCTURE NOT TO SCALE. SEE ORIGINAL PUMP STATION DRAWINGS IN THE APPENDICIES/REFERENCE MATERIAL FOR ADDITIONAL INFORMATION AND DIMENSIONS. 3) SUPPORT HEAVY CONSTRUCTION EQUIPMENT WITH CRANE MATS TO PROTECT CONCRETE APRON. FLOATATION WATER SEGMENT SURFACE SURVEY BASE MAP: �i Q CHECKED: z wlJ SKIRT (DEPTH VARIES) wl w W BALLAST a CHAIN TYPICAL NORTH SEDIMENT REMOVAL SECTION NOT TO SCALE (SEE NOTE 2) NOTES: 1) FLOATING TURBIDITY CURTAINS SHALL BE TYPE II CURTAINS, SEE SPECIFICATIONS. 2) ANCHOR TURBIDITY CURTAINS TO PREVENT DRIFT. INSTALL CURTAINS AS CLOSE TO PROJECT SITE AS POSSIBLE. 3) MAINTAIN TURBIDITY CURTAIN FULL DEPTH OF WATER COLUMN AND ADJUST HEIGHT AS NEEDED TO ACCOUNT FOR EXCAVATION OF SEDIMENT AND SO THAT SEDIMENT ACCUMULATION ON CURTAIN LAYING ON MUDLINE DOES NOT COMPROMISE PERFORMANCE OF CURTAIN. 4) UPON COMPLETION OF THE WORK, REMOVE TURBIDITY CURTAINS IN A MANNER THAT WILL MINIMIZE THE RELEASE OF TURBIDWATER AND COMPLY WITH SPECIFIED WATER QUALITY REQUIREMENTS. TURBIDITY CURTAIN -DETAIL NOT TO SCALE C2 NUM. 1 REVISION I BY I DATE APPROVED: C2 ANCHOR WEIGHTS ANCHOR GEOMEMBRANE EXTEND PLASTIC SHEETING OVER BLOCK TO CAPTURE RUN-OFF (TYP.) BI��,t�, �� 0� VYASx j�C�r�Y � or PROJECT T. BEAN, E. PETERS MANAGER: DESIGNED: J. BINGHAM CHECKED: G. HORVITZ DESIGN ENTERED: E. LINDQUIST 37844 SSIONAL E��' 3/t I* 3 2016 PROJECT No. — 3 2016 3 2016 3 2016 CONTRACT No. CONCRETE WING WALL TO SOUTH PLACE 6—INCH LAYER CLEAN SAND —GRAVEL OVER PROPOSED SEDIMENT SURFACE PER SHEET C2 AND SPECIFICATIONS EL N 1 1.5' TYPICAL ANNUAL WATER ELEVATION IS BELOW ABOUT 10' TYPICAL SUMMER WATER ELEVATION IS7 BELOW ABOUT 8' TRASH RACK EXISTING SEDIMENT SURFACE, SEE NOTE 1 - PROPOSED SEDIMENT SURFACE EL. -4.56 CONCRETE BOTTOM OF FOREBAY (SEE NOTE 3) SEDIMENT REMOVAL ZONE A EL —28.5' RAIL TRACKS N 16' - EL. -11.56 SEDIMENT REMOVAL —� ZONE B STOP LOG SLOT PUMP STATION PUMP EL -9.5' WESTERN EXTENT OF SURVEY NOTES: 1) EXISTING SEDIMENT SURFACE IS BASED ON 2011 BATHYMETRIC SURVEY, PER THE SURVEY NOTES. SEDIMENT SURFACE WEST OF SURVEY LIMITS IS ESTIMATED BASED ON AVERAGE DEPTH OF SEDIMENT AT RAIL TRACK. 2) EXISTING AND PROPOSED SEDIMENT SURFACES AND CONCRETE APRON APPROXIMATELY TO SCALE (1 "=40' FULL SIZE). STRUCTURE NOT TO SCALE. SEE ORIGINAL PUMP STATION DRAWINGS IN THE APPENDICES/REFERENCE MATERIAL FOR ADDITIONAL INFORMATION AND DIMENSIONS. 3) SUPPORT HEAVY CONSTRUCTION EQUIPMENT WITH CRANE MATS TO PROTECT CONCRETE APRON. TYPICAL SOUTH SEDIMENT REMOVAL SECTION STOCKPILED SEDIMENT 6 MIL (MIN.) PLASTIC SHEETING 20 FT. MAX. III III III ��� li Ifl Ili ICI I�I �i SEE NOTE 3 III it 1I I I�------ ____ - -- --------------- ---- III ----,-- -_ ---- ----- INTERLOCKING ECOLOGY \I ` 40 MIL (MIN.) HDPE OR 30 MIL (MIN.) BLOCK WALL POLYETHYLENE GEOMEMBRANE SEE NOTE 6) (NP.) KC: 1120590 HC: 1789407 C01043C16 NOT TO SCALE (SEE NOTE 2) GEOMEMBRANE PROTECTION R=3 90401 (SEE NOTE 2) SEDIMENT STOCKPILE DETAIL NOT TO SCALE C3 C2 NOTES: 1) CONSTRUCT A WATERTIGHT BASIN CAPABLE OF STORING THE ANTICIPATED VOLUME OF EXCAVATED SEDIMENT. 2) INSTALL AND ANCHOR GEOMEMBRANE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PROTECT THE BOTTOM AND TOP OF THE GEOMEMBRANE FROM DAMAGE DUE TO SUBGRADE SOIL AND EQUIPMENT TRAFFIC, RESPECTIVELY. NON —WOVEN GEOTEXTILE, PLYWOOD, OR SAND ARE EXAMPLES OF ACCEPTABLE GEOMEMBRANE PROTECFTION MATERIALS (SEE SPECIFICATIONS). 3) SLOPE STOCKPILES TO MAINTAIN STABILITY OF STOCKPILE, WORKER SAFETY, AND PREVENT DAMAGE TO ADJACENT FEATURES. 4) WEIGH DOWN PLASTIC SHEETING WITH TIRES, SANDBAGS, OR EQUIVALENT. 5) WEIGHT OR TAPE SEAMS BETWEEN PLASTIC SHEETS AND PROVIDE A MINIMUM OVERLAP OF 12 INCHES. 6) 2 FT. X 2 FT. X 6 FT. CONCRETE BLOCK SIZE REQUIRED. PLACE BOTTOM BLOCK ROW PERPENDICULAR TO TOP ROW. KEEP DECANT WATER LEVEL BELOW TOP OF BOTTOM BLOCK UNLESS WALL HYDROSTATIC PRESSURE RELIEF IS PROVIDED. CONTRACTOR MAY SUBMIT AN ALTERNATE STOCKPILE CONTAINMENT METHOD TO PROJECT REPRESENTATIVE FOR APPROVAL. King County A Department of Natural Resources and Parks Water and Land Resources Division MRTCROWWR Regional Services Section Christie True, Director RGCOmmended for Approval By Date BLACK RIVER PUMP STATION SHEET SEDIMENT REMOVAL ca OF 9 g'fpq(pLW4 pEC/WTNQ gfAQ1,K3 AREA SHEETS 12011-06 0 D z c co �y a �x 0 o� ¢b �> 1 z Q