Loading...
HomeMy WebLinkAboutTRO4103917.1W z f-- U Li 0 x n w z J C= CHECKED FOR/COMPLIANCE TO CITY STANDARDS 15 60 0 30 90 SCALE IN FEET TARGEr CALCULATION SUMMARY 7% ACTUAL DESIGN CRITERIA CALCULATION UNIFORMITY AREA AVG. MAINTAINED RA TIO� FOOT CANDLES AVG. MIN. F INT. SE 174TH ST & 0.80 4.00:1 106TH PL SE (ACCESS) 0.80 4.00:1 0.30 6.00. 1 SIDEWALK 0.43 4.30:1 INILRSECTION AND SIDEWALK LIGHT LEVELS ASSUME FUTURE LIGHTING ON THE NORTH SIDE OF SE 174TH ST AND WEST SIDE OF 106TH PL SE IN A STAGGERED PATTERN 110' ON CENTER (55' ON CENTER ON ALTERNATING SIDES OF THE ROADWAY. ILLUMINATION GENERAL NOTES (D4 \ A� NEW � ES U \: rz 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING \, CONSTRUCTION. 1 '`, \ 2 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE 1 DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 72 HOURS IN ADVANCE. A 11 THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. '� \ 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION 0-1 "\\ SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555. S 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S .54 Y RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. '�>t 00 a1 x '-' 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE 2 CONSTRUCTION SITE.; r 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE CITY OF RENTON PUBLIC WORKS ADMINISTRATOR SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 1 8. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR. 1 1 9. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL MINIMUM 3 WEEKS PRIOR TO THE DESIRED APPROVAL DATE. 10. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES / AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL L CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 11. CONTRACTOR SHALL RESTORE ALL GROUNDS DISTURBED BY CONDUIT AND ILLUMINATION SYSTEM INSTALLATION, INCLUDING BUT NOT LIMITED TO: LANDSCAPING, IRRIGATION, CONCRETE SIDEWALKS, ETC. �f 12. THE LOCATION OF FEATURES SHOWN SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR WITH THE CITY OF RENTON TRANSPORTATION MAINTENANCE ASSISTANT z MANAGER, ERIC CUTSHALL, AT (425) 430-7423. 2 h 1 SERVICE BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P-100 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B SPARE 2P-20 AMP 30 AMP NOTES 1. BIORETENTION SOILS TO BE OMITTED AT LIGHT PAD LOCATIONS. 2. SOIL UNDER LIGHT POLE AND LIGHT PAD AND WITHIN THE 1:1 ZONE OF INFLUENCE SURROUNDING THE LIGHT PAD SHALL BE STRUCTURAL FILL OR NATIVE AND MEET 95% COMPACTION. ILLUMINATION CONSTRUCTION NOTES HINSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, THIS SHEET, AND PER CITY OF RENT LE FOUNDATION DEPTH SHALL BE 5.5' IF POLE IS LOCATED WITHIN AREAS OF BIORETENTION SOIL. (POLES 1, 2, 4, 5, 6 AND 7.) 01 D CONSTRUCT STREET LIGHT CONTACTOR FOUNDATION PER CITY OF RENTON STANDARD PLAN 126.1, SHEET IL-03. FOUNDATION SHALL BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STANDARD PLAN 122.1 AND 123, SHEET IL-02. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. LABEL CONTACTOR CABINET WITH ADDRESS LOCATION FOLLOWING CITY OF RENTON STANDARD PLAN 122.1, DATED 0112612015, SHEET IL-02. OAPPROXIMATE LOCATION OF POWER SOURCE. CONTRACTOR SHALL FURNISH AND INSTALL RISER AND COIL CONDUCTORS AS NECESSARY TO MEET PSE REQUIREMENTS. CONTRACTOR SHALL LEAVE SUFFICIENT SLACK IN CONDUCTORS FOR FINAL POWER CONNECTION BY PSE. CONTRACTOR SHALL COORDINATE WITH PSE, INCLUDING COMPLETING ALL FORMS/APPLICATIONS AND PAYMENT OF ALL ASSOCIATED FEES, THROUGH ERIC CUTSHALL, CITY OF RENTON TRANSPORTATION MAINTENANCE ASSISTANT MANAGER, PHONE NUMBER 425-430-7423, FOR SERVICE CONNECTION. PSE SHALL MAKE FINAL CONNECTION TO THE POWER SOURCE. 40 EXISTING UTILITY POLE MOUNTED LUMINAIRE TO REMAIN. HINSTALL TYPE 11 JUNCTION BOX WITH CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 125, SHEET IL-03. (�)NEW UTILITY POLE TO BE INSTALLED BY PSE/INTOLIGHT WITH 53-WATT LUMINAIRE ON 10' ARM AT A 25' MOUNTING HEIGHT. SHOWN FOR REFERENCE ONLY. LEGEND EX NEW/RELOCATE DESCRIPTION 0 JUNCTION BOX TYPE 2 PEDESTRIAN LUMINAIRE POLE UTILITY POLE �C UTILITY POLE MOUNTED LUMINAIRE - - - CONDUIT/CONDUCTOR ® ELECTRICAL SERVICE CABINET OCONSTRUCTION NOTE OLUMINAIRE POLE NUMBER zn� WIRE NOTE Fs+•�c/STEM.. G� S��IVAI 01-19-2017 No. ILLUMINATION WIRING SCHEDULE 0 RACEWAY CONDUIT SIZE ILLUM. #8 SERVICE #2 EQUIP. GRND. PULL WIRE NO. NEW NEW NEW NEW 1 12" SCH40 PVC 2 1 2 12" SCH40 PVC 2 1 2" SCH40 PVC SPARE 1 3 2" SCH40 PVC SPARE 1 2" SCH40 PVC SPARE 1 4 3" SCH80 PVC F3- LQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. 1 SITE ILLUMINATION WIRING DIAGRAM SE 174TH ST PSE NEW SERVICE ILLUM A ILLUM B SPAR I wwmwlo� *11 - � 'wo I N NOT TO SCALE ILLUMINATION POLE SCHEDULE LUM. POLE NO. POLE ID NUMBER*** STREET STATION * OFFSET * LATITUDE ** LONGITUDE ** MOUNT. VOLTAGE SERVICE/ WATTAGE LUMINAIRE TYPE - BASE COMMENT HEIGHT CIRCUIT ITYPE DISTRIBUTION 0 106TH PL SE 34+41.5 20.0' LT 14.0' 240 ILLUM A 44 LED PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STANDARD PLAN 116.1. FOUNDATION DEPTH 5.5'. 2 106TH PL SE 33+32.0 20.0' LT 14.0' 240 ILLUM A 44 LED PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STANDARD PLAN 116.1. FOUNDATION DEPTH 5.5'. �3 106TH PL SE 32+37.5 20.0' LT 14.0' 240 ILLUM A 44 LED PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STANDARD PLAN 116.1. GSE 174TH ST 13+32.0 20.0' RT 14.0' 240 ILLUM A 44 LED PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1 - GCY06P-PC-XX- BLACK- TX STANDARD PLAN 116.1. FOUNDATION DEPTH 5.5'. 0 SE 174TH ST 14+42.0 20.0' RT 14.0' 240 ILLUM A 44 LED PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STANDARD PLAN 116.1. FOUNDATION DEPTH 5.5'. 0 SE 174TH ST 15+52.0 20.0' RT 14.0' 240 ILLUM A 44 LED PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STANDARD PLAN 116.1. FOUNDATION DEPTH 5.5. O7 SE 174TH ST 16+62.0 20.0' RT 14.0' 240 ILLUM A 44 LED PRESTIGE CY17T4-VS3AR-SKY-3-44W-4K- FIXED NEW FOUNDATION AND POLE PER RENTON 240-EA 1-GCY06P-PC-XX-BLACK-TX STANDARD PLAN 116.1. FOUNDATION DEPTH 5.5'. T 3 ►A l iU►v3/ Ur r 3t ► Z) AML ArrMUAIMA I t. (..UN I MAt I UM _-)HALL GUNt IRM AUJUSI MEN 1 S WITH CITY INSPECTOR PRIOR TO IMPLEMENTING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE D NUMBERS SHALL BE PROVIDED BY ERIC CUTSHALL, PHONE NUMBER 425-430-7423 (CITY OF RENTON) FOR INSTALLATION BY THE CONTRACTOR AND INCORPORATION INTO AS -BUILT PLANS. STREET LIGHT FNDTN MOD. IN BIORETENTION SOIL AREAS 11119117 SURVEYED: SCALE: VERTICAL: DATE: NAD 19 AS SHOWN HORIZONTAL: 83/1991 AD 1 9� �- ILLUMINATION P L A N CITY OF MISSION HEALTHCARE AT RENTON 01/19/2017 ,� ` DESIGNED: " IL TDR RENTON FIELDBOOK: DRAWN:At:��PAGE: TDR ONE INCH DRAWING NO: CHECKED: DATUM TTT AT FULL SCALE Planning/Building/Public Works Dept. 1 REVISION BY DATE APPR IF NOT ONE INCH L- O I APPROVED: SCALE ACCORDINGLY UTILITY PERMIT #U 16 - 0 0 3 4 7 4 SHEET: 1 OF: 3 z .., z a �T C n r t 10 Z m z �T 0 D cn D 0 D C m m m C/)® �O Nz �o � o x o r F�J t1y a m D o D y �T= Z U mC13 � TD -