HomeMy WebLinkAbout0931.2120 VAC CNTRL CIRC PFR AUX HAND D OFF —a•--� AUTO REMOTE REMOTE CR1 REMOVE EXIST. 15KW, 3 PHASE, 480V HEATER RELOCATED CATHODIC PROTECTION REPLACE WITH 5KW, 1 PHASE, 240V UNIT HEATER CONTROL PANEL, LOCATE TO EQUAL TO SQ.D CAT. NO. UP2415 CLEAR WALL VENT KWH V POWER FAIL RELAY TELEMETRY AND AUTO CONTROL EXIST. METERS BILLING CABINETS RECONNECT DISTURBED CIRCUITS. ADD EQUIP. FOR PUMP METER PFR BUS BRACING FOR 50K RMS SYM. - EXIST. TEL. SERVICE A DEVICE RATINGS FOR 30K RMS SYM. L__ J 2-500MCM/LEG O2A/480V coT REPLACE EXIST. FAN W/ 1 PHASE 120V MOTOR -0 N ---- UTILITY CT's 800A BUS J 11� OL �— Q TO NEW PANEL "L" 5 � v� EXIST. 2-3" CONDUITS TO � 800A o Z!Tk �� UTILITY POLE. (ONE SPARE). 3P cD Q REROUTE TO NEW 500KVA oFUT. 12.47Y/7.2KV - 480Y/277V 2-3/0 400A NEUTRAL EXIST. PTO NEW 100HP/ PAD MOUNTED TRANSFORMER 1oOHP 200HP r� 1M2 3 M4 3-500MCM + 1-3/0 THWN IN EACH. MOST S2 MOS3 I RECONNECT ALL EXIST. CIRCUITS AND CONTROL LIGHTING, CONVIENIENCE STACKED 50KVAC CAPACITOR SWITCHBOARD DIAGRAM 2"C, 2"C, BANKS W/ CONTACTORS BELOW 3#2/0 3#4/0 21/2 I CIRCUITS TO PANEL "L" C. I / 3#350MCM �PANEL "L" WITH _ 10KVA, 1 PHASE XFMR BELOW CR1 ;dam CVS1 -R2 o---0 o---0 --0 CR1 PVS1 CR2 MS PUMP AND VALVE CONTROL 120 VAC FROM PNL "L" HAND OFF AUTO MS2 MS1 MS4 L TO BE ADDED WITH MS4 _Z�=Lcc HAND OFF AUTO MS3 MS2 MS2 Cl C2 PFC CAPACITOR CONTROL F MS1 CONTROL MS2 CONTROL MS3 CONTROL MS4 CONTROL (FUTURE) POWER FAIL PROTECTION CONTROL NO SCALE MS MS3 h MS4 ---l� GAUGE AND SWITCH ' ASSEMBLY, CONNECT TO RTU ELECTRICAL PLAN 1/4"=1'-0" APPROX. FUTURE 75 KVA TRANSFORMER 12.47Y/7.2KV - 480Y/277V r-----------------------I i I I I I I I I I I r— — — — — — ----------- I I I I I I I I PUGET POWER PRIMARY METERING EXTERIOR INTERIOR CABINET. SEAL ENDS OF CONDUCTOR AND LEAVE CONDUCTOR I 500 KVA TRANSFORMER IN CABINET TO BE TERMINATED I 12.47Y/7.2KV - 480Y/277V BY PUGET POWER. r------------ i r-------------------, I I I I--- - I i I I I I I I j j I I i r ------------ i I I I I A I Lj 800A MAIN L------------� I I '------------------------J I I PRIMARY SERVICE L------ ----J I 12.47Y/7.2KV PRIMARY J-BOX SERVICE CONDUCTORS: 2-3"C, 3-500MCM + 1#4/0 THWN BY PUGET POWER I THIS CONTRACT EACH MOTOR STARTER (MS) SHALL HAVE ADJUSTABLE TIME DELAY FOR START AFTER POWER FAILURE CONTACTORS Cl AND C2 TO BE NEMA SIZE 3, AND BE MOUNTED W/ PILOT LIGHTS AND CONTROL SWITCHS IN A NEMA 1 ENCLOSURE MOTOR STARTER SPECIFICATIONS: MS1 - G.E. CAT# CR270 EFH49A MS2 - G.E. CAT# CR270 GHH49A MS3 - G.E. CAT# CR270 HFH49A R./ ❖ ;•;❖. •----• ORIGINALMINOR PROVISION FOR KWH/DEMAND METER TO STARTERS FOR CONTROL WIRING OF Cl AND C2 r 7 50KVAC PFR. CAP 2 i I Ch I I Ch I I L_-1 LJ EXIST NEW GE POWER MARK LOAD 100HP 200HP 50KVAC PANEL CENTER CAT. NO. o CAP 1 "L" TLM2012C 60A/2P MAIN v 6 - 20/1 CB's N C.T. SPACE EXIST 150HP FUT. 100HP 4 - 15 1 CB's 7'6" MAX J xz >z 1 - 30/2 CB [C], [C2 Cl C2 0 (SPACE 9 10KVA Of CD XFMR XFMR w 800A/3P z MAIN GE #9T21B1006132 FINISH FLOOR �- 7'6" MAX MCC PANEL LAYOUT KWH V POWER FAILURE DEMAND RELAY, TIME MARK #A258B AS PFR A VS 800A BUS, 480V, 3 PHASE I 800: 5 / ♦ � FUT. 175/3 225/3 - ( 300/3 - i 175/3 �I MS1 MS2 MS3 I MS4 I � I i I �--I—J I I 100 150 200 � 100 HP HP HP l\ P EXISTING EXISTING NEW FUTURE MAX. LOAD: 480KVA ® 0.95 POWER FACTOR ONE --LINE POWER DIAGRAM I I ' 1 80/3 80/31 ) Cl �C2 I SPACE 50 K VAC, 3 FIIAJ CAPACITORS C 30/2 0 I N 10KVA 480/120/240 VOLT t