Loading...
HomeMy WebLinkAbout1453.9END ON0ADSRCULVMTWPIPE 6ATTNORT/ \ 3? 3 PERC RATE (MIN/IN) LESS THAN 1 3 4 7 8 to -- -- -- 290 OUTLET OF CULVER /� AT DRAINAGE�'� I _ � � — \ �� - \\\' �_-\ \ \\ \\ � � // � —�� � tr-- 330 FACILITY / — � / low Foci lity 37 MONO dNNI NOW 401-360 34 7-6 NEW 170 L . F ,f.APP' 0XT6 8 S (ASTM F-�O - �� HEAV I�'r�P I PE CULVERT. INVERTS, SLOE ES, D \� ALIGNMENT -AT BACK OF LOTS TO BE ESTABLISOE0 �_33 I -f Imo. P I PE AL I GNMENT AT BACK OF LOT MAC MEArE T0, ',� D TREES . - _ 1 _ 14 1700 INLET OF CULVERT , Ili - ION LOT 44 �� 31 \ / 15 I #3 ' 114 118 \ - 45 44 113 O � 48 47 46 2 _ __� ti I� - Dralnooe Fo*ntlon Focility LOTS 45 THPU 57 REQUIRE j \ ti 112 276 DRAINAGE TO BE CONNECTED 21 TO INDIVIDUAL INFILTRATION� SYSTEMS. SEE DETAILS BELOW. _ _ 1 / � I (1) I ,' _ 9% 19 8 4/0 51 123 i ��J 1 �2� 23 22 21 0 3�0 110 �� ��i� 124 $ B , 52 1 108 4431.7 �- 1 y.53 104 Iffi — �% —' � � R.V. Storage Arsa \N4 77 100 \ 1 l 96At - \ \ i _-_.-- g \ , j 9�� / 04 I 9 ( \ Z , 97 I e�e 82 83. 94dop 95 5 61 rip9 / 106 \ \ \ / ISM= / •• n W 7 wv1 OIII Ts INS . o \ sn"L a 120 caw am) �• � \ \ 0#1 \ I I } INFILTRATION S'_cTFM NOTES 85 EC -z-D REVISED PER CITY OF RENTON REVIEW • \ I 4D REVISED DRAINAGE LOTS 40-52 � 1. Lots 45-52 shall be drained Individually by Infiltration systems 1 /2/85 EC 7D • sized in accordance with the table shown on this sheet. This rGRADE I INK i �iey am MM. �� \ 1 table Is based on the construction of a 3,000 square foo-r single 1� floor house and garage. Drywall size will need to be computed i for anything greater than 3,000 square feet. � r2hausen 2. The Infiltration systems shall be designed in accordance with - H COMPACTED �j I ' MIN. COVER MIN. 2' X 1 2' 1N INFILTR TRENCH WD R Y W E L L D E T AASHED GRAVEL the details shown on this sheet. Each individual lot owner uilI have to provide design on his infiltration system at the time of obtaining a residential building permit. 3. Runoff is required to flow through an oil separator and a filtering screen prior to entering the infiltration system unless otherwise approved by the City of Renton. 4. Percolation tests must be provided showing percolation rates In minutes per Inch. 5. The minimum percolation rate for any infiltration system Is 15 minutes per inch. See the table, this sheet, for typical drywall structures for various percolation rates. Percolation rates must be performed by a registered civil engineer or a registered sanitarian, or a person holding a valid sewage disposal system designer certificate of competency. 6. The ground water table must be at least one foot below the drywall bottom. 7. A minimum ten -foot wide spacing is required between infiltration trenches BACKFILL , r LUNDISTURBED \\ SUBGRADE ; 'r " PERFORATED PIPE "" FILTER FABRIC ENVELOPE MIRAFI 140 OR EQUAL °° 3/4" - 1 1/2" ---_--__ WASHED GRAVEL VARIES M ` �t r! - -.Ot TYPICAL INFILTRATION �� TRENCH SECTION v2 =1-0 .A* .. 11' Consulting Ineers CHMM Int , a � � A1�/1101 "M So. »Nb f. Suft W - KeM, Week. "M - (2") on -no a� � For: SEA VAN PROPERTIES, I NC . s� OHN S.D- F lb SUITE 110, 321 PMNK PLAICE 1 � KI RKLAim , WA. 98033 VW (206) Ate - 6Tto TIt1. • � DRA04AGE AREA MAP «� OEDAR ROM P.U.D. 1391