HomeMy WebLinkAbout1623.521
2
I
I I.
6 �wwkea-
2
on
5�
2
I
I
RW
0 OR FACE OF CURB
SIDEWALK
-- nc_..'.'C
��: 4'
I� III;/
j�
t
!I�r
1
li
GA
i ,s1�,�
TYPICAL —
GARDEN AVE N - WESTSIDE
SAME EASTSIDE EXCEPT NO SIDEWALK
CONCRETE PAD 81
LIGHT STANDARD
2.5'
5-5'
22
t 18 SD
TYPICAL LIGHTING UNDERGROUND SYSTEM
TO LUMINAIRE
TYPICAL DESIGN "B"
JUNCTION BO
FUSE KITS
QUICK DISCONNECT TOP OF CONCRETE
SPLICE KITS 10 AMP IN LINE FUSE FOUNDATION TO BE
CLEAR EPDXY SPLICE- KITS- S.E.C. OR EQUAL LEVEL WITH TOP
KITS ON ALL THRU OF SIDEWALK OR
WIRE RUNS. CURB.
GROUND LUG --
I" MIN. GROUT PAD 1/4'MIN.
UNDER POLE B SE-L DRAIN HOLE
�� ,.
2-(SIZED AS .a
r'�
T II
REQUIRED) i;
LIGHTING -,P
GROUNDSYSTEM
1;�-
WIR '' 1.
isCLAMPTO
CONTAC- ;'II
TOR
PVC
II II
CONDUIT
SYSTEM,
II II
I I
PVC CONDUIT
I I
11 II
SYSTEM
CONCRETE
LL= c J
FOUNDATION
3' SO. OR RD.
5/8" x 8' 0" EE RR
4 JSPOR F POLE HEIGHT
COPPER -CLAD
GROUND ROD 3'DEPTH FOR POLE HEIGHT
20' OR LESS.
DETAIL SHEET
CONCRETE PAD DETAIL
LIGHTING STANDARD a JUNCTION BOX
71 J
Ova-0^; �'<.:T-c :Q,;;t �' Q; •. ,,p
JUNCTION
BOX
STREET LIGHT POLE
PLAN VIEW
- E�zy1't •....v
�f
3
INDIVIDUAL JUNCTION BOX
PLAN VIEW
Ott DEE P .
NOTE: CLASS 'C' CONCRETE
TO BE USE IN
CONSTRUCTION OF PAD
0
0
M 0)
N N
�I J
GARDEN AV E . NORTH
23
i
Sized as required 2"N.P.S.
/SLI►FITTER
e f
2e
\\ 4 VE" O.D.
s,e"R \.I{{ WALL {RACKET
ALUM. ALL 6063-T{
1/2' {NC LOCKBOLT
{R. I{-{ S.S.
FLUSH JOINT
41/2" D. D
TAPERED ALUM. POLE
// 1{{ WALL ALLOY 60{3-TO 30'0'
/ SATIN GROUND FINISM
23'3" f
SHAFT
LU
11 TO It'
BOLT CIRCLE
(4) 1' {NC {ALV. STL.
4 I/2'OF BOLT
ANCHOR {OLT$ WITH
ABOVE FINISHED
NUT{ ARCWASHERS 1
GRADE.
'O,D• ISI NANO1E
AND
i
{ �S/COVER
s.{. •CREWS
;y
31 o'
{A{[ FLANGE ALLOT
rWITH -T{ WITH BOLT
_
COVERS R S.{.{CREWS
_I1�4i. _
iI►
1
""I'r
STANDARD 30' DAVIT
POLE
JUNCTION sox -Mal" see
&W "LV. STEEL
COVER PLATE
(DIAMOND PATTERN)
. ( 1
CIS
24 25
� I .
DETAIL
SHEET
*6 GALV WELDED WIRE LOOP
LV. STEEL FRAME ANCHORED IN PLACE
(DIAMOND PATTERN)
SECTION A -A SECTION S-B
DETAIL SHEET
cv STREET LIGHTING CONTACTOR CABINET
WIRING SCHEMATIC
TYPE B SERVICE 120/ 240 VOLT
MAIN BREAKER
2 POLE 240 VOLT
BRANCH
BREAKERS
120/240 VOLT
TEST 16 POLE
SWITCH
BLOCK
r
0
J
<
Q
F
z
+C
1,1
�1
UTILITY
PLUG
(G.F I.)
STREET LIGHTING
CONTACTORS
�J
J
R R R
CIRCUIT WIRES TO LIGHTING RUNS
WIRING COLOR CODE
TO GROUT
PHOTOCELL
ROD
MOUNTED ON
A. WHITE JACKET (NEUTRAL)
NEAREST
B. BLACK JACKET (LINE)
LUMINAIRE
C. GREEN JACKET (GROUND)
D. RED JACKET (LOAD)
E. GREEN OR BARE COPPER (GROUND)
TYPICAL FUSE L SPLICES KIT
INLINE SPLICE
SPLICE KIT
mow^=�®��
se "
No
v�V.
e
3 Is
MY!`SPLICES.
DETAIL SHEET
Ol
N
J
26
C�
STREET LIGHT
CONTACTOR CABINET BI CABINET FOUNDATION
T F=— I
LOAD CENTER
a
TEST SWITCH 6
48"
I
UTILITY PLUG
I
I,
STREET LIGHTING
E
CONTACTORS
LL==r
MIN.
MIN.
N.
FRONT VIEW PLAN VIEW SIDE VIEW
CABINET EOUIPMENT
I. Pin tumbler I'llsane., ueel Best Core LoCk(dr equal)
keyed for Cx-I with 2 keys
2. 12 gouge (min.) golronized sheet steel
3. Welded seam construction
4. Door with concealed hinges (left side)
5. Interior white boxed -on snomel
6. Exterior- gray- Elch galvanized surface, before Painting.
7. Bottom open - 2"mounting flange (turned inward)
on all sides
B. 4- 3/8a 16 anchor bolts ./nuts and washers
9. 4- 1/4"triong.id, hoped corner lace-do.n Plotee
CABINET FOUNDATION
FRONT VIEW SIDE VIEW
- V2 s16 ANCHOR BOLTS
G.L. CONDUIT ENTR. AREA
o LAN o 0
✓IEW 0 Q
DETAIL SHEET
f �
2' 2" Min. 2' 2' Min.
I
Min.. � Ir
4 4 fi5
�221—�I
TYPICAL TRENCH TYPICAL TRENCH
JOIN WITH STREET CROSSINGS
STREET LIGHTING LIGHTING ONLY
POWER
81 T V CONDUIT
SCHEDULE ICI
AGUSON 8 SONS INC 81518
FACE OF CURB