HomeMy WebLinkAbout1628.4TRENCHING SCHEDULE
UTILITY 8 STREET LIGHTING
24" WIDE X 48"DEEP
STA. 13+85 TO STA. 26+60 RIGHT SIDE
STA. 13+85 STREET CROSSING
STA.21+10 STREET CROSSING
S TREE T L I GH TING
12 " WIDE X 24 " DEEP
STA. 7+ 10 TO STA. 10+75 RIGHT SIDE
STA. 8+40 TO STA. 12+56 LEFT SIDE
STA. 13+64 TO STA. 13+85 RIGHT SIDE
STA. 15+54 TO STA. 24+70 LEFT SIDE
FERGUSON & SONS INC 81518
.TYPICAL LIGHT BASE
AND JUNCTION BOX
� .•lam.•. fw..e �r ,,. •;ir'I'�.�1•��:
:1
♦ . •
• • I
31
14 VAR. ----►�
SIDE
VIEW
SEE STD. SPECS. FOR DIMENSIONS
STREET LIGHTING WIRING SCHEDULE
CONDUIT SIZE
An
A2
FA
1-11/211 STREET LIGHT
1-311 T V CABLE
2-4 11 TELEPHONE CC
2-611 POWER CO.
1 1/2if
1 1/211
EXISTING
�— 24 it
4811
STA. 18+85 TO STA.26+60
1- 1 1/2" STREET LIGHT
1-311 TV CABLE
2-411 TELEPHONE CO.
2- 611 POWER CO.
24" 101
48It
STA. 21+ 10 ST. CROSSING
NO.
1-1 1/211 STREET LIGHT
1-311 T V CABLE
2-411 TELEPHONE CO.
2-611 POWER CO.
WIRE
2- #8
2-#81 1-# 8 ( BARE)
1-4 24 It 10
48"
STA. 13+85 ST. CROSSING
,I- 11/211 STREET LIGH
REVISION
ALL ST. LIGHTING
BY IAPPR.I DATE
16 2w jaz
CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS
SUNSET BLVD. N.
BRONSON WAY N. TO F.A.I. 405
STREET LIGHTING
DESIGNED P• L. DATE NOV• 183 FILE NO.
DRAWN R.A. H
CHECKED SCALE Not tO scale FIELD BOOK PAGE -
APPROVED �� SHEET OF 9
DIRECTOR OF PUBLIC WORK