HomeMy WebLinkAbout1639.3WIRING &
CONDUIT
SCHEDULE
RUN NO.
CONDUIT
WIRE
Ai
1 1/2" P.V.C.
I- 2/C SHD.
1 1/2" P.V.C.
2- 2/C SHD.
0
S. C.
2 -*12
44
S. C.
4-* 12
0
S.C. / i 1/2111 P.V.C. 6 -# 12
r,
Un
0 o o'� I '4o --o 0 0 0 0 o= o 0 0-1 50 o—
SIGNAL HEADS
R 12"(: ) R 12" (: ) R 12"
A 1211 A 12" A 12"
1
G 1212812��
4 3157618, 10
EXIST. TO 9, 1 I, 12
REMAIN
OPT. PROG.
PEDESTRIAN HEAD
HAND
MAN
20,21,22, 23,
24,25
> 7
1211
12"
12"
12"
20 0 20 40 60
LI N D AVE. S. W.
3'
0-- ° o 0-=0 0 0 0-0 0 0 0 2
6� o 0 0 0 0 0 0 0 0- =o'�,
17 -
------ ---- --
8EE g 8
— 4
0
\ 2
25
7 9 �.
2
6
CONSTRUCTION NOTES
OI
EXISTING GALV. STEEL MAST ARM (401) SIGNAL POLE. REMOVE 3 VEH. HDS., I PED. HD. & INSTALL .
I�
2 VEH. HDS, I PED. HD. AS INDICATED ON THE PLANS & DETAIL SHEETS. 7%
—
�t 02
EXISTING GALV. STEEL PED. POLE. REMOVE I PED. HD. & INSTALL I NEW PED. HD. AS INDICATED •
ON THE PLANS & DETAIL SHEETS. i
03
EXISTING GALV. STEEL MAST ARM (301) SIGNAL POLE. REMOVE 2 VEH. HDS., I PED HD. & INSTALL 2
NEW VEH. HDS., I NEW PED. HD. AS INDICATED ON THE PLANS & DETAIL SHEETS. 1
1
04
1
INSTALL NEW CONTROLLER AND CONTROLLER CABINET (P-1) ON EXISTING P-1 CONC. FOUNDATION,
1 1 (
EXISTING GALV. STEEL MAST ARM (351) SIGNAL POLE. REMOVE 2 VEH. HDS., I PED. HD. & INSTALL
1
3 NEW VEH. HDS., I NEW PIED. HD. AS INDICATED ON THE PLANS & DETAIL SHEETS.
@EXISTING
GALV. STEEL MAST ARM (351) SIGNAL POLE, REMOVE 3 VEH. HDS., I PED. HD. & INSTALL
3 NEW VEH. HDS., I NEW PED. HD. AS INDICATED ON THE PLANS & DETAIL SHEETS.
1
�OINSTALL
JUNCTION BOX (TYPE B). SEE DETAIL SHEETS.
08
INSTALL 61X61 VEHICLE DETECTION LOOP. SEE DETAIL SHEETS.
09
SPLICE NEW DETECTION LOOP WIRE TO EXISTING 2-2/C SHD. CABLE OPERATING EXISTING LOOPS.
2"ft
4 5
C.
SIGNAL PHASE DIAGRAM
19 El
17
1 .1
mul
mw
10 24
12 11
� 5
1
,0 O 1
1
o �; 1
1
T%k
I �
O O�
1
11 O
O �
11 �
0
O
1 1
% 0 1
O
1
0looilr_P�113C7_
CITY OF RE
0 NTON
DEPARTMENT OF ENGINEERING
LI ND AVE. S.W. & S.W. GRADY WAY
SIGNAL PLAN
DESIGNED P. L. DATE DEC.183 FILE NO. _
-_ DR."IV!rtRAH/P.L. II_ I
CHECKEDP• L.
SCALE 1 - 20 FIELD BOOK PAGE_
REVISION BY APPR. DATE APPROVED SHEET 3 OF_ 4
DIRECTOR OF ENGINEERING
DIEYERICH POST 1000H . DPOO118D