HomeMy WebLinkAbout1640.2CONSTRUCTION NOTES SEQUENCE DIAGRAM 0 SIGNAL PHASING -► E-W X i� 2 1T N-S X 3 R K PED.ONLY i X X WIRING 8& CONDUIT SCHEDULE 7 RUN NO. CONDUIT SIZE WIRE SIZE 1 1/211 1- 2/C 1 1/2", 1 1/211 (3-#8 Service), (2- 2/C) 211, 1 1/2" (2- 5/C)1 (2-# 10) 311, 1 1/2" (2-5/C, I-2/C), (2-# 10) 211, 1 1/211 (3- 5/C)1 (2-# 10) Q311, 1 1/2" (3-5/C,3-2/C), (2-#10) 211, 1 1/2 (3-5/C, I-3/C), (2-* 10) 311, 1 1/2 (4-5/C94-2/C, 1-3/C), (2-#10) 211 , 1 1/2" (3-5/C, I- 3/C) , (2* 10 ) 311,1 1/211, 1 1/211 (5-5/C), (4- 2/C, 2-3/C), (2-#10) I I 311, 1 1/211, 1 1/211 (5-5/C)2 (6- 2/Cl 2-3/C)1 (2-*-10) 1 1/211 3 -# 8 Service 1 1/2" 2 - 2 /C X -x o X ON \ 8 4 ,8 7 I 8i 12 i 2 6 II 8 2 10 - T A I' 5 3 U) m OI INSTALL GALV. STEEL SIGNAL POLE (TYPE B ) WITH 251 MAST ARM , TWO VEHICLE SIGNAL HDS. (MTG. TYPE L ), TWO PEDESTRIAN SIGNAL HDS. (MTG. TYPE A AND ONE PED. PUSH BUTTON. SEE SPEC. PROVISIONS, DETAIL SHEETS AND STD. PLANS. O2 INSTALL GALV. STEEL SIGNAL POLE (TYPE C) WITH 301 MAST ARM, TWO VEHICLE SIGNAL HDS. (MTG. TYPE L ), TWO PEDESTRIAN SIGNAL HDS. (MTG. TYPE A) AND ONE PED. PUSH BUTTON. INST. A 250 WATT S.V. LUMINAIRE. SEE SPEC. PROVISIONS, DETAIL SHEETS AND STD. PLANS. O3 INSTALL GALV. STEEL SIGNAL POLE (TYPE A) WITH 201 MAST ARM, TWO VEHICLE SIGNAL HDS. (MTG. TYPE L ), TWO PEDESTRIAN SIGNAL HDS. (MTG. TYPE A) AND ONE PED. PUSH BUTTON. INST. A 250 WATT S.V. LUMINAIRE. SEE SPEC. PROVISIONS, DETAIL SHEETS AND STD. PLANS. O4 INSTALL GALV. STEEL SIGNAL POLE (TYPE B) WITH 251 MAST ARM, TWO VEHICLE SIGNAL HDS. (MTG. TYPE L ), TWO PEDESTRIAN SIGNAL HDS.(MTG. TYPE A) AND ONE PED. PUSH BUTTON. INST. A 250 WATT S.V. LUMINAIRE. SEE SPEC. PPOV I SI ONS, DETAIL SHEETS AND STD. PLANS. 5 EXISTING SIGNAL CONTROLLER AND CONTROLLER CABINET (TYPE M ). 6 INSTALL 61 x 61 INDUCTION LOOP DETECTOR, SEE SPEC. PROVISIONS, DETAIL SHEETS AND STD. PLANS. 7 INSTALL TYPE 11B11 CONCRETE JUNCTION BOX. SEE SPEC. PROVISIONS, DETAIL SHEETS AND STD. PLANS. 8 INSTALL TYPE 11C" CONCRETE JUNCTION BOX. SEE SPEC. PROVISIONS, DETAIL SHEETS AND STD. PLANS. 9 INSTALL- FIRE PRE-EMPTION DETECTOR. SEE SPEC. PROVISIONS, DETAIL SHEETS AND STD. PLANS. 10 EXISTING CONCRETE JUNCTION B-OX(TYPE "B11). II EXISTING INDUCTION LOOP DETECTOR. 12 INSTALL OVERHEAD STREET NAME SIGN. 5 x x x x x x x x x x --- ---� 10 I 7 1 adz---- --- — — --- — -- -- _ -- — ---- -- --- -- --- — — PARK SIGNAL HEADS 0 0 0 122,516 1211 AV E. N. 314,778 1.211 8 I' 8" 0 PEDESTRIAN HEADS 20 0 20 40 60 80 NO. REVISION 9110, 1 I, 12, 13,14, 15, 16 I i BY iAPPR.I DATE CITY OF R E N T O N DEPARTMENT OF ENGINEERING PARK AVE. N. Ek N. 8T H ST. TRAFFIIC� SIGNAL INSTALLATION DESIGNED P• L. DATE O C T. 182 FILE NO._ DRAWN R•A• H• 11 _ r� 1 CHECKED P• L. SCALE-ill `C.O FIELD soon �aGE__ APPROVED_ /1``' SHEET DIRECTOR OF ENG14_RING