HomeMy WebLinkAbout1641.6CONSTRUCTION NOTES
O IN -STALL STREET LIGHTING CABINET FOUNDATION AT STA 6+10, 35 FT. LT. INSTALL
CONTACTOR CABINET. (SEE DETAIL SHEET 4-11).
O CONNECT NEW CONDUCTORS TO EXISTING ILLUMINATION
CIRCUIT.
WIRE NOTES
RUN
CONDUCTORS
CONDUIT
A3
NO.
2
2"
A4
NO.
8
2"
A
4
NO.
8
A
8
2
NO.
As
2
NO.
8 (EXIST)
1-1/2" (EXIST)
2 NO.
EMPTY
8 (NEW)
1-1/2"
�2 ROUTE CONDUIT AND CONDUCTORS TO EXISTING POWER VAULT AND PROVIDE FOR
POWER CONNECTION IN ACCORDANCE WITH UTILITY REQUIREMENTS.
O3 INSTALL LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX
(SEE DETAIL SHEET 4-5). INSTALL 30 FT. LIGHTING STANDARD WITH 150 WATT
HIGH-PRESSURE SODIUM VAPOR LUMINAIRE.
�4 INSTALL LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX
(SEE DETAIL 4-5). (NOTE POLE AND LUMINAIRE TO BE INSTALLED BY OTHERS).
@5 INSTALL TYPE 1 JUNCTION BOX.
O INSTALL 10 FT. OF CONDUIT FOR FUTURE USE. INSTALL CAP.
O DISCONNECT EXISTING LIGHTING CIRCUIT IN JUNCTION BOX AT NORTHEAST CORNER OF
SW 7TH STREET AT NACHES AVENUE SW (LOCATION TO BE DESIGNATED BY CITY OF
RENTON INSPECTOR).
�8 CONNECT EXISTING LIGHTING CIRCUIT TO NEW CONDUCTORS.
SERVICE CABINET
TYPE III SINGLE PHASE 120/240 VOLT GROUNDED NEUTRAL
BREAKER AND CONTACTOR SCHEDULE
CIRCUIT
NO.
MAIN BREAKER
AMPS
BRANCH BREAKER
AMPS
CONTACTOR
AMPS
REMARKS
MAIN
100
-
-
A-1
-
20
30
240 VOLT
A-2
-
20
30
240 VOLT
E X I S T . m c1 r% 1 P^ %, A l I I T
EX:
LUMINAIRE SCHEDULE
LUMINAIRE
NO.
LAMP
WATTAGE
POLE
LOCATION
CL OF POLE
TO CL OF ROAD
ARM
LENGTH
MOUNTING
HEIGHT
CIRCUIT
NO.
REMARKS
3540C
150 WATT
STA 7+29
26.3' RT.
8 FT.
30 FT.
A-2
3541C
STA 8+80 (2>
25.3' LT.
A-2
FUTURE LUMINAIRE.
3542C
150 WATT
STA 10+55
23.3' RT,
8 FT.
30 FT.
A-2
3000C
150 WATT
STA 0+65
37' LT.
A-1
3001C
150 WATT
STA 2+15
33.5' RT.
A-1
3002C
150 WATT
STA 3+65
33.5' LT.
A-1
3003C
150 WATT
STA 5+15
32.8' RT.
A-1
1912C
STA 6+24
29.6'LT
A-1
EXIST. FOUNDATION - FUTURE LUMINAIRE.
IN L-a Na IV O I'V I L I Y VLL/
FOR APPROVAL
M
BY
3-
GENERAL NOTES
1. CONTRACTOR SHALL NOTIFY ALL UTILITIES LOCATED WITHIN PROJECT LIMITS
48 HOURS PRIOR TO COMMENCING WORK.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES.
CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY OF RENTON
IMMEDIATELY UPON DAMAGE.
3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CITY OF RENTON DESIGN
STANDARDS AND SUPPLEMENTAL SPECIFICATIONS.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL REQUIREMENTS PER
CITY OF RENTON POLICY DATED 12/15/88.
S. NO BOX, PAD, POLE, OR CABINET SHALL BE PLACED IN THE SIDEWALK.
P 0 W E L I
EXIST. LUM:
Awn 1. R_
ACHES—
12
wo
LEG END
® LIGHTING CONTACTOR CABINET.
COMBINATION FOUNDATION WITH LUMINAIRE.
® COMBINATION FOUNDATION WITHOUT
LUMINAIRE.
® TYPE 1 JUNCTION BOX WITH PAD AND
GALVANIZED LID.
-------------- CONDUIT. J/, di
H rf�
� f
z DAVID 1. HAI LIN AND ASSOCIATES
SEE NACHES
AVENUE SW "` �;STFR� \�� �� 1022 YALE AVENUE NORTH
ILLUMINATION=;rSSENU�/ SEATTLE , WASHINGTON
1GN��
PLAN", SHEET 2. .i+'101 (206) 340-0835
ILLUMINATION PLAN
CITY
DEPARTMENT
ROADWAY
NACHES
STA 6+00
OF RENTON
OF PUBLIC WORKS
ILLUMINATION
AVENUE S.W.
TO STA 12+00
DESIGNED u. nr►rlLiry DATE 4/89 FILE NO.
DRAWN DesignCAD
SCALE NOTED FIELD BOOK PAGE_
CHECKED
NO. REVISION BY APPR. DATE APPROVED elmaT� ICNORKf SHEET 2 OF 3
NOTE: LATERAL CONDUITS SHALL BE PVC SCH 40.
STREET CROSSING CONDUITS SHALL BE PVC SCH 80.
oo.'t.CJi•�.�.c.. s-�s- 89