HomeMy WebLinkAbout1641.6CONSTRUCTION NOTES O IN -STALL STREET LIGHTING CABINET FOUNDATION AT STA 6+10, 35 FT. LT. INSTALL CONTACTOR CABINET. (SEE DETAIL SHEET 4-11). O CONNECT NEW CONDUCTORS TO EXISTING ILLUMINATION CIRCUIT. WIRE NOTES RUN CONDUCTORS CONDUIT A3 NO. 2 2" A4 NO. 8 2" A 4 NO. 8 A 8 2 NO. As 2 NO. 8 (EXIST) 1-1/2" (EXIST) 2 NO. EMPTY 8 (NEW) 1-1/2" �2 ROUTE CONDUIT AND CONDUCTORS TO EXISTING POWER VAULT AND PROVIDE FOR POWER CONNECTION IN ACCORDANCE WITH UTILITY REQUIREMENTS. O3 INSTALL LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL SHEET 4-5). INSTALL 30 FT. LIGHTING STANDARD WITH 150 WATT HIGH-PRESSURE SODIUM VAPOR LUMINAIRE. �4 INSTALL LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL 4-5). (NOTE POLE AND LUMINAIRE TO BE INSTALLED BY OTHERS). @5 INSTALL TYPE 1 JUNCTION BOX. O INSTALL 10 FT. OF CONDUIT FOR FUTURE USE. INSTALL CAP. O DISCONNECT EXISTING LIGHTING CIRCUIT IN JUNCTION BOX AT NORTHEAST CORNER OF SW 7TH STREET AT NACHES AVENUE SW (LOCATION TO BE DESIGNATED BY CITY OF RENTON INSPECTOR). �8 CONNECT EXISTING LIGHTING CIRCUIT TO NEW CONDUCTORS. SERVICE CABINET TYPE III SINGLE PHASE 120/240 VOLT GROUNDED NEUTRAL BREAKER AND CONTACTOR SCHEDULE CIRCUIT NO. MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS MAIN 100 - - A-1 - 20 30 240 VOLT A-2 - 20 30 240 VOLT E X I S T . m c1 r% 1 P^ %, A l I I T EX: LUMINAIRE SCHEDULE LUMINAIRE NO. LAMP WATTAGE POLE LOCATION CL OF POLE TO CL OF ROAD ARM LENGTH MOUNTING HEIGHT CIRCUIT NO. REMARKS 3540C 150 WATT STA 7+29 26.3' RT. 8 FT. 30 FT. A-2 3541C STA 8+80 (2> 25.3' LT. A-2 FUTURE LUMINAIRE. 3542C 150 WATT STA 10+55 23.3' RT, 8 FT. 30 FT. A-2 3000C 150 WATT STA 0+65 37' LT. A-1 3001C 150 WATT STA 2+15 33.5' RT. A-1 3002C 150 WATT STA 3+65 33.5' LT. A-1 3003C 150 WATT STA 5+15 32.8' RT. A-1 1912C STA 6+24 29.6'LT A-1 EXIST. FOUNDATION - FUTURE LUMINAIRE. IN L-a Na IV O I'V I L I Y VLL/ FOR APPROVAL M BY 3- GENERAL NOTES 1. CONTRACTOR SHALL NOTIFY ALL UTILITIES LOCATED WITHIN PROJECT LIMITS 48 HOURS PRIOR TO COMMENCING WORK. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CITY OF RENTON DESIGN STANDARDS AND SUPPLEMENTAL SPECIFICATIONS. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL REQUIREMENTS PER CITY OF RENTON POLICY DATED 12/15/88. S. NO BOX, PAD, POLE, OR CABINET SHALL BE PLACED IN THE SIDEWALK. P 0 W E L I EXIST. LUM: Awn 1. R_ ACHES— 12 wo LEG END ® LIGHTING CONTACTOR CABINET. COMBINATION FOUNDATION WITH LUMINAIRE. ® COMBINATION FOUNDATION WITHOUT LUMINAIRE. ® TYPE 1 JUNCTION BOX WITH PAD AND GALVANIZED LID. -------------- CONDUIT. J/, di H rf� � f z DAVID 1. HAI LIN AND ASSOCIATES SEE NACHES AVENUE SW "` �;STFR� \�� �� 1022 YALE AVENUE NORTH ILLUMINATION=;rSSENU�/ SEATTLE , WASHINGTON 1GN�� PLAN", SHEET 2. .i+'101 (206) 340-0835 ILLUMINATION PLAN CITY DEPARTMENT ROADWAY NACHES STA 6+00 OF RENTON OF PUBLIC WORKS ILLUMINATION AVENUE S.W. TO STA 12+00 DESIGNED u. nr►rlLiry DATE 4/89 FILE NO. DRAWN DesignCAD SCALE NOTED FIELD BOOK PAGE_ CHECKED NO. REVISION BY APPR. DATE APPROVED elmaT� ICNORKf SHEET 2 OF 3 NOTE: LATERAL CONDUITS SHALL BE PVC SCH 40. STREET CROSSING CONDUITS SHALL BE PVC SCH 80. oo.'t.CJi•�.�.c.. s-�s- 89 MEW �� / 0 ;;,rhv