HomeMy WebLinkAbout1652.19L UMINAIRE
I.,IJMIN—
AI RE
NUMBER
101,102
127,128
147,148
161,162
309,310
369,370
104,105
107,108
141,142
143,145
146,
165
168,
i
?_ F7
166
125
163
123,124
144
126
129
130,131
308
307
103,121,
122z
149,150,151,
164,367,3F8
301,306,341,
365,366
305,324,352,
353,361,
,472
344,
345,346,347,
348
327,328,329,
330,331,332
325,326
349,350,351
411,412
MAST
ARM
LENGTH
8'
MOUNT—
ING
HEIGHT
40,
40'
LAMP
SIZE
TYPE
400
WATT
S.V.
400
WATT
S.V.
LUMIN—
AIRE
DISTRI—
BUTION
TYPE IT
TYPE II
SOCKET
SETTING
BXL
FRONT/11
BXL
FRONT/11
METHOD
OF
MOUNTING
SIGNAL
POLE
5' FROM
FACE OF
CURB
7' FROM
FACE OF
CURB
5' FP�OE�1
FACE OF
CURB
7' FROM
FACE OF
CURB
5' FROM
FACE OF
CUE 3
7' FROM
FACE OF
CURB
5' FROM
FACE OF
CUIB
7' FROM
FACE OF
CURB
SIGNAL
POLE
5' FROM
FACE OF
CURB
EXISTING
U/G
UTILITIES
SEWER LINE APPROX. 6'
FROM FACE OF CURB.
30" COVER.
12" STORM DRAIN APPROX.
2' FROM FACE OF CURB
30" COVER
12" STORM DRAIN APPROX.
6' FROM FACE OF CURB
30" COVER
4" GAS LINE APPROX. 6'
FROM FACE OF CURB. 8"
WATER MAIN, LOCATION
UNKNOWN, 30" COVER
SEWER LINE APPROX. 4'
FROM FACE OF CURB.
30" COVER
4" GAS LINE & SEWER LINE
APPROX. 6' FROM FACE OF
CURB, 8" WATER MAIN
LOCATION UNKNOWN
STORM DRAIN APPROX. 8'
FACE GF CURB. 30" COVER
2" GAS LINE APPROX. 6'
FROM FACE OF CURB
30" COVER .
2" GAS LINE APPROX. 5'
FROM FACE OF CURB. 8"
WATER LINE LOCATION
UNKNOWN. 30" COVER
2" GAS LINE APPROX. 6'
FROM FACE OF CURB. 8"
WATER LINE APPROX 4'
FROM FACE OF CURB
30" COVER
2" GAS LINT' APPROX. 6.1
FROM FACE OF CURB.
STORM DRAIN LINE APPROX
3' FROM FACE OF CURB.
30" COVER
4" GAS LINE APPROX 6'
FROM FACE OF CURB 8"
WATER MAIN, LOC. UN—
KNOWN 30" COVER
4' FROM 2" GAS LINE APPROX.
FACE OF 5.5' FROM FACE OF CURB.
CURB
BASE
INSTALLED
BY
OTHERS
7' FROM
FACE OF
CURB
TO BE
INSTALLED
BY
OTHERS
5.5' FROM 12' WATER LINE APPROX.
FACE OF 6' FROM FACE OF CURB,
CURB DEPTH UNKNOWN.
LUMIN— MAST
AIRE ARM
NUMBER LENGTH
401,402,403, 8'
404,405,406,
407,408,409,
410
423,424,425,
426,427,428,
429,430,431,
432,441,442,
443,444,445,
446,447,448,
449,450,451,
452,461,462,
463,464,465,
466,467,468,
469,470
421,422
301,302,303,
304,321,322,
323,362,363.
364,342,343
MOUNT—
LAMP
ING
SIZE
HEIGHT
& TYPE
25'
250
WATT
S.V.
40' 400
WAT".'
S.V.
LUMIN—
AIRE
DISTRI—
BUTION
TYPE II
SOCKET
SETTING
F
BXL
FRONT/11
METHOD
EXISTING
OF
U/G
MOUNTING
UTILITIES
5.5' FROM
12" WATER LINE APPROX.
FACE OF
6' FROM FACE OF CURB,
CURB
DEPTH UNKNOWN
5.5' FROM
FACE OF
CURB
5.5' FROM
FACE OF
CURB
7'FROM
FACE OF
CURB
4" WATER LINE APPROX.
6' FROM FACE OF CURB.
SERVICE PANEL
SERVICE
MAIN BREAKER
CIRCUIT
BRANCH BREAKER
CONTACTOR
NO.
RATING
NO.
RATING
SIZE
1
150
AMPS
1—A
30 AMPS
1
1—B
60 AMPS
2
1—C
60 AMPS
2
1—D
30 AMPS
1
1—E
30
AMPS
120
VOLT
SIGNAL SERVICE
2—A
30
AMPS
120
VOLT
SIGNAL SERVICE
2—B
30
AMPS
120
VOLT
SIGNAL SERVICE
2—C
30
AMPS
120
VOLT
SIGNAL SERVICE
3
150
AMPS
3—A
30 AMPS
1
3—B
60 AMPS
2
3—C
60 AMPS
2
3—D
30 AMPS
1
3—E
30
AMPS
120
VOLT
SIGNAL SERVICE
4
150
AMPS
4—A
60 AMPS
2
4—B
60 AMPS
2
4—C
60 AMPS
2
4—D
60 AMPS
2
%3 weso,4
i A,t ®A of i
S
4ssloNAL
/� 52.
471
DIXT901CH-POST COMPANY INC MOON (It-M)
washington