CONSTRUCTION NOTES
INSTALL GALVANIZED STEEL SIGNAL POLE TYPE E-1 WITH 40' MAST ARM AT STATION
23+83 LT, 5.01 FROM THE CURBLINE; 3 VEHICLE SIGNAL, HEADS MTG. TYPE L; 2
PEDESTRIAN SIGNAL HEADS MTG. TYPE A; AND 2 PEDESTRIAN PUSH BUTTONS. INSTALL
400 WATT SODIUM VAPOR LUMINAIRE. CONNECT FIELD WIRES TO THE APPROPRIATE
TERMINALS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J-21C.
INSTALL GALVANIZED STEEL SIGNAL POLE TYPE C-3 WITH 30' MAST ARM AT STATION
11+44 LT, 5.5' FROM THE CURBLINE EXTENDED; 2 VEHICLE SIGNAL HEADS MTG. TYPE
L; 1 PEDESTRIAN SIGNAL HEAD MTG. TYPE B; AND 2 PEDESTRIAN PUSH BUTTONS. IN—
STALL 400 WATT SODIUM VAPOR LUMTNAIRE. CONNECT FIELD WIRES TO THE APPROPRI—
ATE TERMINALS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J-21C.
INSTALL GALVANIZED STEEL STGNAL POLF TYPE D-2 WITH 35' MAST AR-'T AT STATION
24+58 RT, 5.0' FROM THE CURBLINE; 2 VEHICLE SIGNAL HEADS MTG. TYPE L; AND
1 PEDESTRIAN SIGNAL HEAD MTG. TYPE B. INSTALL 400 WATT SODIUM VAPOR
LUMINAIRE. CONNECT FIELD WIRES TO THE APPROPRIATE TERMINALS. SEE SPECIAL
PROVISIONS, DETAIL SHEET AND STANDARD PLAN J-21C
(� ) INSTALL, GALVANIZED CTEEL SIGNAL POLE TYPE C-3 WITH 30' MAST AP1'2 AT STATIO
12+44 RT, 5.0 FROM THE CURBLINE; 2 VEHICLE SIGNAL HEADS MTG. TYPE L; 2
PEDESTRIAN SIGNAL HEAD MTG. TYPE A; AND 2 PEDESTRIAN PUSH BUTTONS. INSTALL
400 WATT SODIUM VAPOR LUMINAIRE. CONNECT FIELD WIRES TO THE APPROPRIATE
TERMINALS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J-21C.
OPROVIDE AND INSTALL 2'" DIA. PEDESTRIAN PUSH BUTTON POST WITH 2 PEDESTRIAN
PUSH BUTTONS AT STATION 23+68 RT, 5.0' FROM THE CURBLINE. SEE SPECIAL
PROVISIONS, DETAIL SHEET AND STANDARD PLAN J-21B.
PROVIDE AND INSTALL 2'-" DIA. PEDESTRIAN PUSH BUTTON POST WITH 2 PEDESTRIAN
PUSH BUTTONS AT STATION 11+32 RT, 11' FROT0' THE CURBLINF EXTENDED. SEE
SPECIAL PROVISIOTI, DETAIL SHEET AND STANDARD PLAN J-21B
PROVIDE AND INSTALL 2j" DIA. PEDESTRIAN PUSH BUTTON POST j!TTH 2 PEDESTRIAN
PUSH BUTTONS AT STATI& 12+50 LT, 6' FROM THE CURBLINE FXTFND7D. S-r
SPECIAL PROVISIONS, DETAIL SHEET AND .STANDARD PLAN J-21B
PROVIDE AND INSTALL JUNCTION BOX TYPF I, DESIGN B. SEE SPECIAL PROVISIONS
AND STANDARD PLAN J-19.
PROVIDE AND INSTALL JUNCTION BOX TYPE III. SITE SPECIAL PROVISIONS AdD
STANDARD PLAN J-20.
PROVIDE' AND INSTALL JUNCTION BOX TYPE IV. SEE SPECIAL PROVISIO►_'JS AND
DETAIL SHEET.
INSTALL 6'x40' VE'HICLE DETECTION LOOP. SEE SPECIAL PROVISIONS, DETAIL
SHEET AND STANDARD PLAN J-21B.
CONSTRUCT CONTROLLER FOUNDATION AND INSTALL COT\TTROLLFR TYPE D-1 CABTNFT.
CONNECT FIELD 'rdIRES TO APPROPRIATE TERMINALS. SEE SPECIAL PROVISIONS
AND DETAIL SHEET.
INSTALL 6' x 6' VEHICLE DETECTION LOOP.
SHEET AND STANDARD PLAN J-21B .
SEE SPECIAL PROVISIONS, DETAIL