Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1680.1
13 N OD OPT/CA L LY PROGRAMMED N CO N LENS SEQUENCE N LEGEND ---} VEHICLE SIGNAL PEDESTRIAN SIGNAL O� PUSH BUTTON AND POST --- MAST ARM SIGNAL POLE WITH LUMINAIRE (� PULL BOX TYPE 'B' F71 PULL BOX TYPE 'C' LOOP 6'x 6' ® EXISTING PUGET POWER SERVICE SIGNAL CONTROL CABINET LIGHT CONTROL CABINET N OD N OPrlCALLY PROGRAMMED >> O OM OD N © 1-12 inch --- 1-2/c #14 AWG Beldfoil 8720 ® 1-12 inch 2-2/c #14 AWG Beldfoil 8720 0 1-22 inch 3-5/c #14 AWG 2-8/c #14 AWG ® 1-2/:inch 4-#8 AWG (existing) 1-4 inch Street Lighting 12-2/c #14 AWG 8-5/c #14 AWG 7-8/c #14 AWG 1-11/c #14 AWG © 1-21-2 inch 4-#8 AWG (existing) 1-4 inch Street Lighting 12-2/c #14 AWG 8-5/c #14 AWG 7-8/c #14 AWG 1-11/c #14 AWG B2 + B I 20 0 20 40 60 80 t � Scale in Fe e t I ( Continued ) © Existing 1-3 inch 3-2/c #14 AWG 3-5/c #14 AWG PHASING DIAGRAM A2 + B, A I + A 2 AI +_B2 the ex,)ib° s, t �n`sno of neore,-,_ - SP���ein0 SYgtefn SEQUENCE DIAGRAM DIRECTION H E A D 1 2 3 4 5 6 7 8 9 10 II 12 I J PHASE Nn, I� WB A2. 2, 3 R R R R G G G A R R R R A W 8 L T B, 1 f- A R R 4- A R R R R R R JR EB L T BZ 7 F 4- A R R R RR R R R R E B AI8 9 rR R G A R R G A R R R R A N B>F S B 3 4, 10 R R R R R R R R /-- A R R R NB tSB A 5,6 )11112 R R R R R R R R R R G A R S.."t4l-r,We A� PED I 18 , IS DW DW, I W F DW DW W FD D D D D X E -- W $�� N- S N A3PED 13,15,17, DW DW DW 1 D , DW DW D 1 DW W FD X E- W Az PED 14 , 16 DW D DW DW W W W F D D�DWDW D REGION 90. STATE RED. AID PROJECT NO. SHEET NO. M-1113 (1) 4 Provide and install pedestrian push buttons ,;ith sign message as per Detail Sheet. (post mounted) ®5 Install 6' x 6' induction loop detector. See Special Provisions, Detail Sheet and Standard Plan J-21e. 6 Provide spare conductors for fire pre-emption detectors. Coil and store at end of mast arm in signal head. \:J Provide and install Design C Junction Box per J-20 of Standard Plans. 0 Provide and install Design B Junction Box per J-20 of Standard Plans. OProvide installation for traffic signal control cabinet, all auxiliary equipment and accessories. (Controller and cabinet furnished by city.) 0 Widen roadway and extend sidewalk. See Sheet li Provide and install new street light control cabinet. Remove existing street light control cabinet. 2-8/c #14 AWG 4-#8 AWG (existing) De - energize ® Existing 1-3 inch 2-#8 AWG(existing) Street Lighting* 7-2/c #14 AWG 4-5/c #14 AWG C01aSTRUCTION !'eOTES 3-8/c #14 AWG ® Existing 1-3 inch 2-#8 AWG (existing) Remove existing beacon and associated hardware. 0 Street Lighting• 3-2/c #14 AWG O Provide and install 30 ft. mast arm on existing pole; one 2-5/c #14 AWG vehicle signal head mtg. type Psi; two vehicle signal heads 1-8/c #14 AWG mtg. type L and two pedestrian signal heads mtg. type A. 09 1-12 Connect field wires to the appropriate terminals. See inch 2-2/c #14 AWG Special Provisions. 1-2 inch 2tr AWG O3 Provide and install galvanized steel signal pole type E-1 CITY OF R E N T O N S Street Lighting with 40 ft. mast arm; one vehicle signal head mtg. type Pi; DEPARTMENT OF ENGINEERING Existing two vehicle signal heads mtg. type L and pedestrian signal } TRAFFIC ENGINEERING DIVISION heads mtg. type A. Also install 250 Watt Sodium Vapor 1-4 inch 2-#8 AWG Street Lighting luminaire. Connect field wires to the appropriate terminals. I+ N ®U�QAL L /%E` See Special Provisions, Detail Sheet and Standard Plan J-23. �X/III 1-2 inch 2-Puget service wires N E SUNSET BLVD. I. REVISED PER REVIEW C E M II-22-77 'DESIGNED C. E. M DATE 1 1 11 1 7-7 FILE NO. ;Z. ReevlSecl ,fir ,Peview Ca DRAWN C. E. MORGAN I CHECKED_ SCALE /" = 40' FIELD BOOK PAGE NO. I REVISION BY APPR. ( DATE APPROVED SHEET--4—OF-6 I DIRECTOR OF ENGINEERING No