Loading...
HomeMy WebLinkAbout1722.8WIRING INTERCONNECT AND SIGNAL SERVICE LUMINAIRE RUN CONDUIT RUN CONDUIT NO. SIZE WIRE SIZE FUNCTION NO. SIZE WIRE ,SIZE FUNCTION 1 11" 6 - #6 STREET LIGHTING CIRCUITS I-1 2" 1 11/C - LUMIN- LUMIN- MAST MOUNT- LAMP AIRS METHOD EXISTING, A 2-A, 2-B & 2-C 1-2 21" INTERCONNECT AIRE ARM ING SIZE DISTRI- SOCKET OF U/G NUMBER LENGTH 2" 2 - #6 STREET LIGHT CIRCUTT 2-A 2 - ll/C INTERCONNECT HEIGHT & TYPE BUTION SETTING MOUNTING UTILITIES 2 - #6 STREET LIGHT CIRCUIT 2-B I- 31" 2 - 11/C INTERCONNECT 101,102 8' 30' 400 W II BH REAR 5' 2 ,104 - #8 STREET LIGHT CIRCUIT 2-C SIGNAL WIRES 103MERCURY /2 FROM FACE - #12 PHOTOCELL 1-4 31" 1 - 11/C INTERCONNECT 107,203, 105,106 VAPOR OF CURB SIGNAL WIRES 204,205, 3 11j 2 - #6 STREET LIGHT CIRCUIT 2-A '� 206,2079 4 lam" 2 - #ln STREET LIGHT #101 I- 3 1 - 11/C INTERCONNECT 301,305 111 4 - ##6 STREET LIGHT CIRCUIT 2-A 2 - SIGNAL h/IRS 201 8' 30' 400 W II BH REAR 5' I 6 11j #10 SIGNAL SERVICE 1-A MERCURY /2 FROM FACT 2 - #6 STREET LIGHT CIRCUIT 2-B i 11 3 - #12 PHOTOCELL I-7 1� 2 - #10 SIGNAL SERVICE 3-A VAPOR OF CURB /7\I-8 31" 2 - 11/C INTERCONNECT 11" 4 - #6 STREET LIGHT CIRCUIT 2-B 2 - #10 SIGNAL SERVICE 1-A 202 8' 30' 400 W II BH REAR 5' 3 - #12 PHOTOCELL MERCURY /2 FROM FACE 8 1-" 2 - #6 STREET LIGHT CIRCUIT2-B SIGNAL WIRES VAPOR OF CTJRB 18 11" 4 - #6 STREET LIGHT CIRCUIT 2-B lO l 2 #10 STREET LIGHT #209 0,2 80MERCURY 9 8' 301 400 W CII BH REAR SIGNAL 11 21" 2 - #10 STREET LIGHT #209 2VAPOR /2 POLE SIGNAL WIRES A It 4 - #6 STREET LIGHT CIRCUIT 2-B 303,304 8' 40' 400 W II BXL FRONT SIGNAL SODIUM /11 POLE SIGNAL WIRES VAPOR A 11" 2 - #10 STREET LIGHTS #210 & 211 0 - ' 3 7,08 3 2 8 401 400 W II BXL FRONT IST,AND 2 - #10 STREET LIGHTS #212 & 213 SODIUM /11 A 3" 4 - #10 STREET LIGHTS #210 & 211 VAPOR IGNAL WIRES 302,306 8' 25' 250 W II 6 51 1 1�" 2 - #10 STREET LIGHT #211 SODIUM FROM FACT VAPOR OF CURB l: 12" 2 - #10 STREET LIGHTS #212 & 213 1 211,213 8' 30' 400 W II BH REAR 33' FROM 2" 4 - #10 STREET LIGHTS #212 & 213 MERCURY /2 CENTERLINE SIGNAL WIRES VAPOR 18 11" 2 - #10 STREET LIGHT #213 2 - #8 STREET LIGHT CIRCUIT 2-C 4 - #8 STREET LIGHT CIRCUIT 2-C 21 10" 2 - #10 STREET LIGHTS #303, 304 & 305 2 2" 4 - #10 STREET LIGHTS #303, 304 & 305 SIGNAL, WIRES SERVICE PANEL 1" 2 - #10 STREET LIGHTS #304 & 305 24 21" 4 - #10 STREET LIGHTS #304 & 305 SERVICE MAIN BREAKER CIRCUIT BRANCH BREAKER CONTACTOR SIGNAL WIRES NO. RATING NO. RATING SIZE 12�, 12" 2 - #lO STREET LIGHT #305 1 35 AMPS 1-A SIGNAL SERVICE NONE 11" 2 - #10 STREET LIGHTS #306„307 & 308 2 100 AMP 2-A 30 AMP 1 11" 2 - #10 STREET LIGHT #306 2-B 60 AMP 2 1?" 2 - #10 STREET LIGHTS #307 & 308 11" 2 - #10 STREET LIGHTS #307 & 308 2-C 30 AMP 1 SIGNAL WIRES 3 30 AMPS 3-A SIGNAL SERVICE NONE 2'- "D.B.TELEPH. CABLES APPROX.44' FROM CENTERLINE, 30" COVER. 2'-2"D.B.TELEPH. CABLES APPROX.40' FROM CENTFRLINE, 30" OVER , \ F PH/� •�e�`olf WASM��co P 1722- i _ - CITY OF RENTON ct-u: s0,; tWr DEPARTMENT OF ENGINEERING � �E�iS7ERL� TRAFFIC ENGINEERING DIVISION FSSloNA...��G`�rr S.W. GRADY WAY L P0. W416 ILLUMINATION SCHEDULES DES IGNEDJF! F' ____ pATEfES�__L_ �� FILE NO _ L_v -- _._. DRAWN __" --- Wi5hingt011 - - --- — _ - - - CHECIEED /Q SCALE FIELD BOOK-- -PAGE--- ENGINEERS ARCHITECTS PLANNERS SURVEYORS NO REVISION BY APPR DATE APPROVED__ SHE[T__ Q— OF- / --- .