HomeMy WebLinkAbout1748.1GEN ER A L IE : 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND THESE PLANS. 2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 3. INSTALL ALL STREET LIGHTING MATERIALS SHOWN ON THE PLANS, EXCEPT AS NOTED. ALL MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY, EXCEPT AS NOTED. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ,ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE THE WORK WITH THE UTILITIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON DAMAGE. J7.1 ,4 n12x {3' u N GO'd5•Jf' E 01 1° 7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON TRAFFIC ENGINEERING DIVISION (PHONE 235-2620) FOR INSPECTION PURPOSES, 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE ENGINEER. 8. THE CONTRACTOR SHALL INSPECT EACH STREET LIGHTING STANDARD INCLUDING WIRING, CONNECTIONS AND LUMINAIRE, AND REPAIR ALL DEFECTIVE WIRING AND CONNECTIONS PRIOR TO ENERGIZING SYSTEM. OTHER DEFECTS SHALL BE BROUGHT TO THE ATTEN110N OF THE CITY OF RENTON TRAFFIC ENGINEERING DIVISION FOR RECTIFICATION PRIOR TO ENERGIZATION OF THE SYSTEM. X ;�S' 3. SNS i F 00 a RECOMMENDED FOR APPROVAL 7- Fcj -t -7 $9 m o� \ 9+00 � 12+00 1 x 14+00 13+00 11+0t.7<, 10+00 11+ FLAG N C TE : PROVIDE NEW SERVICE WIRING TO EXISTING STREET LIGHTING CONTACTOR CABINET. PROVIDE NEW CONCRETE BASE AND INSTALL SERVICE RACEWAY. PROVIDE NEW GROUND ROD & NEW GROUNDING ELECTRODE CONDUCTOR. RECONNECT ALL EXISTING WIRING. CONNECT TO PSP&L 50 KVA 120/240 VOLT, 1 PHASE, 3 WIRE PAD MOUNTED TRANSFORMER. REMOVE EXISTING TEMPORARY METER, ENCLOSED BREAKERS, WIRING, AND SUPPORT STRUCTURE NEAR STREET LIGHTING CONTACTOR CABINET. , VERIFY EXACT LOCATION OF BURIED SEWER, STORM, AND WATER UTILITIES PRIOR TO INSTALLATION OF RACEWAY. LEGEND ®' -� EXISTING LIGHTING STANDARD AND NO. SYMBOL ( KIM EKG 401, 250 WATT ) — — PVC CONDUIT. SEE WIRING SCHEDULE ® STREET LIGHT CONTACTOR CABINET ® TYPE 1 JUNCTION BOX (EXISTING) TYPE 2 JUNCTION BOX T� UTILITY CO. PAD MOUNTED SERVICE TRANSFORMER WIRE SCHEDULE SYMBOL FLAG NOTE SYMBOL SCALE I "=40' 17Vk Sparling & Associates, Inc. ELECTRICAL ENGINEERS 1920 Eastlake Avenue East Seattle, Washington 98102 (206) 324-1555 4�I,