Loading...
HomeMy WebLinkAbout1749.1�1 PSP4 L J-BOX - 120/240V, 10 POWER. (Z)OI/O AL CONDUGTOKS. ='r / SEE NOTE i0 r Orl � s ► _ _ 5rq O 4 \ -� 1 ii �G1 •�1 ;1 I� 1 II II 1 I I I► ► Ir I I I I (— 5TA 1014 + 00 II I II I� II i I -�--- _4 v, No. I Ai 3006 C 5TA 1015+Go " STA 1015 + 5(o L.A.KE ,NASHIN�TON E�vy. —5TA 101Z+25 I NOTE: 5TA1012.+2.5 PER KING COUNTY ASSESSOR MAP OF THE S.E. -4 2O)-Z4-5 DATES 10/1B/55 I SITE PLAN 6CALE:1"=Z& E N W I 1- 405 OFF RAMP r/I r INLINE SPLICE SPLICE KIT 4" THICK CONCRETE PAD f r i i 1100 0- zz N I.C. / O /' c2 f __ �1\ WYE SPLICES INDIVIDUAL JUNCTION BOX I i I 7/*,Or - - - _ Soli PVG CONDUIT L•TTZENC.H TYPICAL LUMINAIRE - FRONT ELEVATION NOT 'TO SCALE 5'-al 51DEWALK {---3' , .. . • ' (a" CURES 71 - ROADWAY CONCRETE HANDHOLE I i 4" TWICK CONCRETE. PAD FOR LIGIMT STANDARD _ . 4 JUNCTION BOX I i � � � PHOTOCELL V CONCRETE RASE 0 \ 15O W H.PS. LUMINAIRE TAPERED ALUMINUM POLE ; TYPICAL LUMINAIRE-PLAN VIEW NOT TO SCALE (LOCATIONS Al 4 A2) 5/16" GALV STEEL COvER PLATE (DIAMOND PATTERN) I 1 46 GALV WELDED 'NIPE LOOP GALV. STEEL FRAME ANCHORED IN PLACE (DIAMOND PATTERN) d' ;at I � r -•�� t SECTION A -A SECTION B-B JUNCTION BOX - DESIGN "B" (LOCATIONS 51 13Z55 G 1 CZ) #8 BARE COPPER GROUND WIRE TYPICAL DESIGN "B° JUNCTION BO FUSE KITS SPLICE KITS QUICK DISCONNECT IO AMP IN LINE FUSE CLEAR EPDXY SPLICE- KITS-S.E.C. OR EQUAL-� KITS ON ALL THRU WIRE RUNS. 2- (S12ED�S REQUIRED) LIGHTING SYSTEM WIRE TO CONTAC- ..rr..rrrr. virr.rranw. .� II GROUND II CLAMPPVC II TOR�� CONDUIT SYSTEMII PVC CONDUIT SYSTEM 5/8" x B. 0" COPPER -CLAD GROUND ROD I I CONCRETE �L� FOUNDATION f0 LUMINAIRE I TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. 1/4"rA I N . DRAIN HOLE I I I 11 II II I I II II I I I I �J �3- SO. OR RD. -„J 4' DEPTH FOR POLE HEIGHT GREATER THAN 25'. 3' DEPTH FOR POLE HEIGHT 25' OR LESS. TYPICAL LIGHTING UNDERGROUND SYSTEM 28,3'� SHAFT 8" GROUND LU 6�� CITY OF RENTON APPROVAL 2 uN. P.S. Sized as required /SLIPFITTER �d -- - t 43jy 0.D. 58" •188 WALL BRACKET • . ALUM. ALLOY 6063-T6' V2"8NC LOCK80LT GR. 18 - 8 S. S. �`FLUSH JOINT 4%C"O.D. TAPERED ALUM. POLE .219 WALL ALLOY 6063-T6 SATIN GROUND FINISH 35'0" 11TO 12" " BOLT CIRCLE (4) I BNC GALV, STL. 4 I/2" OF BOLT ANCHOR BOLTS WITH d kh NUTS AND WASHERS ABOVE FIN- O.D.+ 151 HANDHOLE ISHE GRADE 4"x 6" OPENING G W/COVER AND —� S. S. SCREWS S: 3'0" SASE FLANGE ALLOY .,-••--3.66 -T6 WITH BOLT �• 'S� —4N COVERS 8 S.S. SCREWS?' STANDARD 35' DAVIT POLE REVIEWED BY: L•►- DATE: REVIEWED BY: DATE: REVIEWED BY: 2> !> , ,. ; DATE: iyw APPROVED BY: PUBLIC WORKS DIRECTOR DATE r NOTES: 1. COMPLY WITH CITY OF RENTON "STANDARDS FOR STREETLIGHTING DESIGN OF RESIDENTIAL AND ARTERIAL STREETS". 2. COMPLY WITH NEC AND LOCAL CODES & ORDINANCES. 3. SCOPE OF WORK: A. PROVIDE TWO (2) STREETLIGHTING STANDARDS WITH 15OW HIGH PRESSURE SODIUM COBRAHEAD FIXTURES (GE M-400A DROP LENS) ON 35' ANCHOR BASE POLE. B. PROVIDE HANDHOLE•AT EACH POLE BASE WITH INTEGRAL 4" PAD OVER ANCHOR BASE. C. FIXTURES WILL BE PHOTOCELL CONTROLLED. D. PROVIDE HANDHOLE ADJACENT TO PSP&L HANDHOLE WITH IN -LINE FUSES. E. PROVIDE COMPLETE CONMJIT AND WIRING SYSTEM. 4. BURY ALL CONDUIT A MINIMUM OF 24" BELOW GRADE. ALL CONDUIT SHALL BE 12" PVC W (2) #8 CU THW CONDUCTORS AND (1) #10 CU GROUND. PROVIDE SCHEDULE 40 ON NORTH SIDE OF N.E. 44TH STREET AND SCHEDULE 80 AT STREET AND DRIVEWAY CROSSINGS. 5. INSTALL GROUND RODS & SPLICES IN J-BOXES AND IN -LINE FUSES IN HANDHOLE AT EACH POLE. 6. LUMINAIRE - GE M-400A CUT OFF WITH DROPPED LENS FOR 150W HIGH PRESSURE SODIUM LAMP WITH REGULATOR BALLAST RATED FOR 240 VOLT OPERATION. IES PATTERN M-S-III. 7. COORDINATE WITH PSP&L RENTON (PHONE 255-2464) CONCERNING SERVICE 'REQUIREMENTS. 8. COORDINATE INSTALLATION WITH EXISTING UNDERGROUND UTILITIES. OBTAIN STREETCROSSING PERMIT FROM CITY OF RENTON. 9. INSTALL STREETCROSSING CONDUIT AND JUNCTION BOXES Cl & C2 ON SOUTH SIDE OF N.E. 44TH STREET. FUTURE LUMINAIRE BY OTHERS. RESTORE ROAD SURFACE AS REQUIRED. LOCATE C1 & C2 WITHIN FUTURE CURB LINE. 10. FUTURE STREETLIGHTING CONTROL CABINET LOCATION BY OTHERS. 11. INSTALL A PULL TAPE IN ALL FUTURE CONDUIT RUNS. LEAVE MINIMUM 3' TAIL COILED IN EACH HANDHOLE. 12. CONSTRUCTION NOTES A. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. B. AS -BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF ALL PROJECTS. C. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES REGARDING THEIR FACILITIES LOCATED WITHIN THE PROJECT LIMITS 48 HOURS PRIOR TO COMMENCING WORK. D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY IMMEDIATELY UPON DAMAGE. SYMBOL LEGEND INDIVIDUAL JUNCTION BOX. Lo- LUMINAIRE, STANDARD &ANCHOR BASE ASSEMBLY. -- 1P SCHEDULE 40 PVC WITH (2) #8 CU THW. — - - 11" SCHEDULE 80 PVC. FUTURE LUMINAIRE (NIC). N.LG. NOT IN CONTRACT. - - - - - - - - 12" WATER LINE. 41-L DECAL / aIVBERS NUMBERS -mar//1/S 2-/,v vc14-vT 7/6.4L Z Y LVSTALLED ONLY !A/ DRY WEA7,416R 50° OR ABorE �U�yBE,Q/�VG EX.4ti1PLES I 2 I 3 2 AL 1h - _N LAJ LETTER SlVrIXED LETTER P�PEr_iXED C/TY owly—rD PUGET POWER OWNED - FL 0{•Y PLAN VIEW STPEET L /GNT STANDARD D CCA L NUMBER//UG SYSTEiV STREET LIyHTIN61 PLAN FOR N.E.44-M STREET, RENTON 44 R E N TO N WKENNA CONSTRUCTION CO. 11Z010 DES MOINES WAY S. SUITE 108 SEATTLE WA. ENGINEERED ELECTRICAL SYSTEMS CONSULTING ENGINEERS, INCORPORATED • 201 J.S. DITTY BLOG., BELLEVUE, WASH. 98004 9 PHONE (206) 454-5440 DESIGNED: JRP DRAWN: CJP APPROVED: JRP DATE: 2/Co REV: El OFI 1