CITY OF RENTON-----,
FH
WV
I
SDMH-96
TOP 25.78
FL 17.98
J I �
CAP EXISTING WATER
0 PROPERTY LINE
EX. CB 'A', TYPE 1
v P
WL
23.89 21.59
B0T 18.89 .. -__ _ ----
I I EX. ASP PAVEMENT
C
14 001 I - SLOPES TO DRAIN
i TOWARDS EX. CB "A"
UTC I 1
I F
1
WV
2-,�-
f 26
_ - 25 00
- EX.
/ GATE, o
\ 2
:i EXIST. PAVEMENT
SWALE
0
A PORTION OF THE N.E. 1 /4 OF SECTION 18, T23N, R5E, W.M.
��- I ✓ i'CL
r
i; RENTON, WASHINGTON
KEY C�
PAD
v �
m
' ' 12 GATE
f r�
1 rn
PM
SAFETY
EX. SIGN
13' (+) '
1
0 Do
•
�• �•
• i•
001,
EXIST. SSMH
EX. 12" CONC. ; _ _ _ CONTRACTOR SHALL SAWCUT \ LIFT STA NOTE: DRAIN PURIFICATION WATER
--J- ° -�- RIM 25.33 TO EX. SANITARY SEWER SYSTEM,
REFER TO BEFORE ;�� EX ASPHALT PAVEMENT & FILLED W/WATER PUMP TO EX. SSMH ALONG AIRPORT
& AFTER DETAIL THIS z �� ; MATCH EX. GRADE \ TO BE ABANDONED FRONTAGE ® STA 12+12 OR DISCHARGE
SHEET fi I ` s TO NEW SANITARY SEWER SIDE SEWER EX. \ INSTALL: PHASE II
� FOR NEW BUILDING
SAWCUT AND RESTORE VAULT
� 221 LF 8" D.I.P.
EX. IMPROVEMENTS "IN -KIND" r I ^' FH \ CL 52 I
N
CAUTION UTILITY CROSSING
1p
LIMITS OF
j o oho EX. ANTI -SIPHON
EX. BM #RW-1 \ o' LOOP /
LEASE (TYP.)
o EL 27.05 I 1 I m wWATER AS FOUND ON
x "OLD" BOEING PLANS. / �\
-25--
(UTILITY LOCATE DID
EX. APRON NOT FIND)
EX. VERT SCV VLT --' I \ `' I� ° --- �� ^` EX. SIGN
i EX. SCV
2.5' HIGH - /
�:- - EX. WATER AS 13' N 825.11 >'17' E
EX. WM_/- 83.
PICKED -UP BY __W
UTILITY LOCATE - -� - -
12 00a L� / - -
h''�� j �--tip-- - ��'i � - � EX. "C
SSMH ITY \
WATER \ EX. EMH
RIM 25.0 I 1 I CB -I
i TOP 24.77 I _ - -_ 7�
26 - -
INV W 23.07' \ /� o
CB -I BOT 21.77 EX. CITI -OF /� / EX. SEWER AS �'
EX. 12" I k �� RENTON WM ,;L/ PICKED -UP BY EX. POWER do
TOP 24.59 CONC. -' `� UTILITY LOCATE
INV E 22.59 o `L
ti - D /
INV W22.69 SD-0 --- ----��--------- - - - Y/ ------ -o � �"
� � /�
BOT 22.09`�� I L �o, o ok 27 _ - �� �• s�
I b EX. (EX. EV-- - \
- - - POWER ^�
LEVEN HANGAR - WATER MAIN
221 LF 8' D.I.
(D 1-12"X8" TAPPING TEE (MJXFL)
1-8" TAP VALVE (FLXMJ)
CONC. THRUST BLOCKING
SEE BEFORE & AFTER
DETAILS BELOW
W
1 8 X8 X6 TEE (MJXFL) �Jl/
1-8" VERT. CROSS (MJXFL) 2
2 - 8" BLIND FLANGES, (1) W/
2" TAP & 2" TEMP. BLOW -OFF ASSEMBLY
1-8" PLUG (MJ) TO EAST
1-FIRE HYDRANT ASSEMBLY, 6" G.V.
CONC. THRUST BLOCKING
EX. 12" WATER MAIN
REMOVE 2-8" PLUGS,
2-2" TEMP. B.O. ASSEMBLY'S
2 TEMP. CONC. BLOCKS
INSERT 8" SOLID SLEEVES (LB)
AND 8' NIPPLES SIZED TO F1T
WATER DATA TABLE
O1 CONTRACTOR SHALL VERIFY LOCATION
& SIZE OF EXISTING CITY WATER MAIN.
02 INSTALL:
1" WATER METER PER
CITY OF RENTON STDS.
(3) INSTALL:
1-8"X8"X6" TEE (MJXFL)
1-8" VERT. CROSS (MJXFL)
2 - 8" BLIND FLANGES, (1) W/
2" TAP & 2" TEMP. BLOW -OFF ASSEMBLY
1-8" PLUG (MJ) TO EAST
1-FIRE HYDRANT ASSEMBLY, 6" G.V.
CONC. THRUST BLOCKING
* CONTRACTOR NOTE:
1) ADDITIONAL FITTINGS & PIPE
MATERIAL MAY BE REQUIRED.
IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO PROVIDE
THE NECESSARY FITTINGS AND
MATERIAL TO INSTALL THE
WATER SYSTEM.
2) WATER METER SIZE AND SUPPLY
LINE SHALL BE VERIFIED
W/ OWNER/ ARCHITECT.
EX. TEL� \ I tiohh - EX. H/E
EX. SOUND EX. 4" CI -FM
i EX. PAVING / PER BOEING PLANS
FLIGHT BUILDING CONC. (TYP.)
EX. 60 ® MAIN
NEW FUELING 2
RC TO I� IVI A I N STATION BY
\ N 40'O6'57" W 3,4%8 SF OFFICE
OTHERS �o-
® 47.48 \ \�3 EX. CITY OF
RENTON WM
EX. PAVING CB -I - f
- --
EX. WM J � \ EX. 8" �.� TOP 24.77 �_-_ ---_- - _---y=-----------
INV NW 23.17
EX. SIGN ' j \ I
BOT 22.77
SDMH-G-96
RIM 27.80
INV W 19.30
t
INV N 18.80
WL 19.20
BOT 17.20 CB -I -
- _ \
- � EXIST.
EX. PAVED PARKING TOP 26.30 CURB
/ CB TO REMAIN INV E 24.90 \ ? \
NFL EX. SIGN EX. GAS R = 118 81• EXIST. BOT 25.00 \\ EX. WMH \
- -- EX. 12" W \ = 53'50'24" WALK f Q \ RIM 27.2
\ L = 111.64' EXIST. \ - EX. 6" CONC. CB-1
�. V� \ y TOP 26.4
EX. 48" 1 1
EX. 18"
\ RENTON STRIPING l \ � INV W 6
EX. VAULT EX. REBAR & CAP _ FH \ \ \\ 13 >
INV S 24.5 \ CITY OF
BOT 24.4 \ RENTON
FIBER OPTIC N180123.957 -
TOP 27.7 El298355.103 _ `
- - - - - - - - EX. SIG 6 G
FH
WV 214.37' N 8924'31" W
GATE
AIRPORT FRONTAGE ROAD - 1
� O I
EX. 6" CONC. --� wv
WV
WATER 8c SEWER PLAN _- - EX. 6" CONC.
-- ,t- --- -- - - -S
RETROFIT EX. CITY OF RENTON „ CB -I p
FIRE HYDRANTS W/ 5" STORZ 1 =20 d
TOP 26.7
EX. 6"
FITTINGS PER CITY STANDARD INV E 23.1 P' CONC. EX. SIGN
DETAILS, (2) PLACES INV N,S 23.0 EX. REBAR & CA
BOT 23.0 N180072.151
El298651.078
SITE
S
RENTON W
z
167
RENTON
AIRPORT
N. AIRPORT WAY
Z
CD
S 2ND STREET
S 3RD STREET
VICINITY MAP
NTS
DESCRIPTION
STORM SEWER
SANITARY SEWER
WATER
FIRE HYDRANT
WATER VALVE
WATER METER
CATCH BASIN
SEWER MANHOLE
LIGHT FIXTURE
AC PAVING
LANDSCAPE
CURB
FENCE
GUARDRAIL
UTILITY CONFLICT NOTE:
CAUTION:
NEW
EXISTING
-SD
>0 -
_SS_
')S--
_W_,
---
g
Mm
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH
OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES
AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION.
THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1-800-424-5555 AND THEN POTHOLING ALL OF
THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY
WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS
ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE
CONTRACTOR SHALL CONSULT POE ENGINEERING, INC. TO RESOLVE ALL PROBLEMS PRIOR TO
PROCEEDING WITH CONSTRUCTION.
LEVEN HANGAR FACILITY
243 W. PERIMETER ROAD, MUNICIPAL AIRPORT
RENTON, WA
WATER &SEWER PLAN
C2 OF 3
POE Engineering,
CIVIL &STRUCTURAL ENGINEERING/CONSULTING
400 WEST GOWE STREET, SUITE 310
KENT, WASHINGTON 98032
(253) 859-5121 /FAX (253) 859-5207
Inc.