Loading...
HomeMy WebLinkAboutR-404106`, W IOU LLI z 10' PRIVATE DRAINAGE ESM'T _IJ 0 CLEANOU TO MATCH x FINISH GRADE. LOCATION PER PLAN 0 CO. 0 L oO 0- . ..0. ..:.0 � :0. 2.0' 0.' ' :.O..o .. ..0 0-.'..- -O 21, 12:'0..�'o . 1' MIN. WIDTH FREE DRAINING BACKFILL COMPOSED OF WASHED GRAVEL, PEA GRAVEL, ECT. (TOP OF GRAVEL TO MATCH FINISH GRADE) FILTER FABRIC - MIRAFI 70OX OF EQUAL (3 SIDES ONLY) 6" PERFORATED PVC PIPE WITH POSITVE GRADIENT INTERCEPTOR TRENCH DETAIL N.T.S. A / 'A- 4 OVERFLIY� MAX. WA T a RECTANGUL,4 / NOTCH WIDT41 " .Cd A. NOTCH ELEVATIO - aA . PIPE SUPPORT3"x0.9/ ° / BOLTED OR IMBEDDF�D " WALL AT MAX. 3' SP d C \ \ c .NXI GRATE ELEV. = 390.00 6" MIN. 12" d d \ ° d z e- A /�\\/\\� dq A. d d ° 390 380 370 360 50 390 380 370 360 00 (8) EVENLY SPACED HOLES ON 10 378' SOLT CIRCLE FOR BOLTING TO FLANGE CONNECTION LEVEL LINE- -___-__ _�__ __- ___ _- _ FRONT SIDE NOTES: MAXIMUM OPENING OF GATE HANDLE WITH LOCK PIN ADJUSTABLE LOCK HOOK WITH LOCK SCREW O LIFT HANDLE SHALL BE ATTACHED PER MANUFACTURER'S RECOMMENDATIONS 1' ROD OR TUBING, VARIABLE LENGTH 1 SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM 8-MZG-32. OR CAST IRON ASTM MS CLASS 30B AS REQUIRED 2 GATE SHALL BE 81NCH DLA UNLESS OTHERWISE SPECIFIED 3. GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE). WELDING, OR OTHER SECURE MEANS. 4. LIFT ROD, AS SPECIFIED BY MFR. MTN HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD- 5 GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT. STOP TAB, OR SOME OTHER DEVICE 5 NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. 7 MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT, 8 FLANGE MOUNTING BOLTS SHALL BE 318' DIA. STAINLESS STEEL -4 ALTERNATE CLEANOUT;SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE AND HAVE A SM BOLT. 10 318' BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION, t1NL7�50iH(gN'IS[ 11DT(D -WING IS NOT TO SGILF INTS) STD. PLAN - 237.30 ..� PUBLIC WORKS TEE SECTION SHEAR GATE 9/28/2018 I DEPARTMENT GAZ DATE 5. 0' WIDE GRATE W/ 5' X 10' REMOVABLE a a Iz___AND SOUTH SIDES FOR MAINTENANCE C 10.20' ACCESS. TOP OF GRATE EL=390.00 DCO _ _ 4" PER PVC FOOTING DRAIN-0 1.07. MIN. CONNECT TO CB-2 SOCO W/GRATE TOP=389.50 IE=377.10 :.:. 10' WIDE CURB CUT WITH GRAVEL ACCESS BEHIND SIDEWALK. INSTALL 4 X BOLLARDS AT BACK OFpRNI!EIq:Y.- SIDEWALK. MIDDLE TWO BOLLARDS SHALL BE ° ` .-".?C?��:= ..::.' .i: •s = :: i M�' - REMOVABLE. OUTER ° BOLLARDS FIXED. J. W Z I W CLEANOUV 8" ca W ii I SHEAR GATE W CB-2, TYPE 2-48" o �° o 0 W/SOL.RND.LKG.LID ao ° CZm TOP=38Z70 B IE=381.93 (87S) 12" OUTLET PIPE _ =a IE=37Z60 (4 SE) 12 IE.• 376.75 IE=376.68 (12'E&W) } WQ WSEL C II ° cl r q / / < d.. DD / d WELD 12 GA. BOTTOM PLATE WITH 11116 "0 ORIFICE#1 SHARP EDGE, / SHOP DRILLED IN PLATE. i \/ ELEV.- 374.75- d a \ SED. STOR.373.00 °64. - 8TTIc'r\S 1�IA14S Know what's below. Call before you dig. NOT TO SCALE -SD 8D�1 I I I GRATE 5' yl i i EL-'90.OG \\\ : 4 s ADDITIONAL LADDER RUNGS (IN SETS) TO 7 MIN CLEARANCE i0 Sa ALLOW ACCESS TO TANKS OR VAULTS ANY PORTION Of FLOW RESTRICTOR _ WHEN CATCH IS FILLED WITH WATER TEE INCLUDING ELBOWS / REMOVABLE WATERTIGHT COUPLINGFLANGE OR FLANGE 7 MIN. ELBOW RESTRICTOR- SEE DETAIL AND NOTE 10 / ANGLE AS / NECESSARY. / SEE NOTE 7 W MIN 6' MAX. '-+I 7 MIN, �--' PLATE WELDED TO ELBOW WITH PLAN VIEW ORIFICE AS SPECIFIED. SEE NOTE 3 ELBOW RESTRICTOR DETAIL ELEVATION PER PLANS 12- MIN UNDER FRAME 8 SOLID COVER MARKED -DRAIN"WITH PAVEMENT LOCKING BOLTS PER STD. PLANS 2D4.40 AND 204 Y 18" MAX. ( VERTICAL BAR GRATE FOR SECONDARY INLET 6'MIN DESIGNWATER ELBOW RESTRICTOR, �URFAZT SEE DETAIL AND NOTE 10 HANDHOLDS. STEPS, OR LADDER PIPE SUPPORTS, SEE NOTE 6 r 1T (TYP,) 7.5 x D 3}1} SEE NOTE 9 (TYP.) MIN. 7 MIN13 T 1 ISOMETRIC i OUTLET POPE, SEE INLET PIPE NOTES 18 S 7 MIN SHEAR GATE WITH CONTROL ROO FOR INVERT AND CLEANOUTNRAIN (ROD BENT AS REQUIRED ELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH COVERT 17 SECTION OF PIPE ATTACHED BY PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL 7 17 ABN. WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 NOTES: SECTION A USE A MIMIMUM OF A 54• DIAMETER TYPE 2 CATCH BASIN. OUTLET CAPACITY IOD•YEAR DEVELOPED PEAK ROW 1 METAL PARTS PREFERRED TO BE STAINLESS STEEL. ALUMINIZED STEEL OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2. OR 5 4 FRAME AND LADDER OR STEPS OFFSET SO. A CLEANOUT GATE IS VISIBLE FROM TOP B CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 114'. 6. PROVIDE AT LEAST ONE 3' X D90 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL (MAXIMUM 3'-(' VERTICAL SPACING) 7 LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN 8 LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER 9- WHEN CONNECTING TO A NEW PIPE USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAW. WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED UNLESS OTHERWKE NOTED, DRAWING K NOT TO SCALE INTOO TD. PLAN - 237.00 _♦j� PUBLIC WORKS FLOW CONTROL STRUCTURE I�° °Y �7� DEPARTMENT RESTRICTOR TEE Mart in Pastucha8/13 DATE �FINISH GRADE VARIES 1' MIN. COVER (TYP) HOLLOW CORE PANELS TOP EL=389.0 MAX. WSEL=387.50 6& 50' SOLID LID & FRAME PER COR STD 204.50 - ADJUST LID ELV'S PER FINISH GRADES (TIP) 36"0 ACCESS RISER �j\\\ 382.00 10.75' DETENTION LIVE STORAGE M\ TOP BAFFLE /z \\ PREFABRICATED LADDER----- REMOVABLE BAFFLE WALL OR COPOLYMER STEPS r \ PER COR STD 204.60 /\ A _p WQ OUSEL=376.75 39.50 3.75' WETPOOL /\ IE.• 375.00 (12 IN) \\ 374.00 BAFFLE 0 BOT B\\ - - - - SED. STOR. 373.00 / � END OF SLOPE FL=370.74 - -2.00q SLOPE �' ��/ 0.50% SLOPE-� 5% MIN.) SLOPE 1 \\ I I CELL 1 DETENTION WETVAULT - SECTION A 0 SCALE HORZ.• 1" = 10', VERT.: 1" = 5' I I -------------------------- -----� FINISH GRADE VARIES SOLID LID & FRAME PER COR STD 204.50 1.5' SEE PLAN FOR nl LCPE BYPASS LINE SEE PLAN SDCO . �1.00 COVER MIN. (TYP)COVER MIN. (TIP) ADJUST LID ELV'S PER FINISH GRADES (TIP) , X TO CB-1 & CONTINUATION 4" SOLID PVC FOOTING OUTFACE PIPE ®1.00q MIN. u7 GRATE IF 5 yl �so�so Aso �so OU7FALL PROPERTY LINE j TOP HOLLOW CORE PANELS EL=389.00 36"0 ACCESS RISER CORE PANELS EL=389.00 36"0 ACCESS RISER TR. A DETENTION WET VA UL T - PLAN DETAIL \ /\ - - - - MAX. WSEL=387.50 - - - - - - - / SCALE. 1" = 10' \\\\ 6&50' .10 12" VENTILATION P E TJ670 5.00' I 1 375.00 (12"IN� z i i ACCESS RISER LO W/ SOLID LOCKING LID D� Q5 h! CELL 1 2 OF II 5�1 "V BOTTOM 0 0.5% MIN., MAX DETENTION WETVAULT 30,922 CF (ACTIVE DETENTION) i i L0 10,786 CF (WETPOOL) i i m , o Ib 39.50 -----_-_-_---- --- --- --- - ---- --- --- -L---- ------ -� 1G'.00-��-10.00 I TERNAL WALL 6 .50 M EL: 387. 0 0 5% MIN. _ 5% MIN. LO WQ EL:37.75 SED 373.00 CELL 2 -- - - - - - - - --- --- "V" - -- F� BOTTOM0 0.5 X 0 z_ � 5.00' WETVAULT STRUC RAL IE.3 6.75 (1 "OUT) DESIGN BY OTHERS I I o In "' 0 36 0 ACCESS RISE W SOLID LOCKING LID 12" VENTIL RON PPE -- 10.75' DETENTION LIVE STORAGE RESTRICTOR PREFABRICATED LADDER_ \\ OR COPOL Y MER STEPS j\ _p WQ WSEL=376.75 _ _ _ PER COR STD 204.60 \� \� \\ 3.75' WETPOOL `\ //� �\ SED. STOR.=373.00 \\ END OF SLOPE EL=371.04 5% (MIN.) SLOPE 0.509 SLOPE "V" BOTTOM CELL 2 DETENTION WETVA ULT - SECTION B SCALE: HORZ: 1" = 10', VERT.: 1" = 5' 5 PER CITY OF RENTON COMMENTS TLK 1-6-2023 NEM SURVEYED: SCALE: - VERTICAL NAVD 1988 1> ¢ PER CITY OF RENTON COMMENTS TLK 9-30-22 NEAR DESIGNED: 1 - 10 1 HORIZONTAL, NAD 1983/1991 CITY OF 1700 NW GILMAN BLVD, STE 200 3 PER CITY OF RENTON COMMENTS KAL 5-18-21 KAL NEM ISSAQUAH, WA 98027 2 PER CITY OF RENTON COMMENTS KAL 6-17-19 KAL DRAWN TLK RENTON N TO N IVIL ONE INCH DATU M PHONE: (425) 821-5038 1 CONSTRUCTION PLAN SET KAL 9-24-18 KAL CHECKED: NEAR AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: NEAR SCALE ACCORDINGLY 18" MA%. FROM CENTER OF ACCESS COVER OR DOORS REQUIRED FRAME TO STRUCTURE WALL FOR STEP ACCESS LADDER - SOO' GRATE, GRATED ACCESS DOOR, OR LOCKING ACCESS PANEL OVER SECOND CELL FOR VAULTS WHERE SURFACE AREA OF SECOND CELL IS GREATER THAN 1,250 SQUARE FEET, 4%OF THE TOTAL SURFACE AREA MUST BE GRATED AND A 600' REMOVABLE LOCKING PANEL SHALL BE PROVIDED OUTLET WETPOOL SHAPED BOTTOM - WIDTH - -__V• -_------_- INL�10 S MIN. GRAVITY DRAIN A REMOVABLE BAFFLE OR WALL SEE NOTE 2 SEE NOTE 71TYP.) 8' MAX. FROM EDGE OF OPENING TO STRUCTURE • WALL FOR STEP ACCESS FRAME AND SOLID COVER WETPOOL LENGTH 12' MIN. VENTILATION PIPES AT MARKED'DFWW WITH CORNERS (TYP.), SEE NOTE 6 LOCKING BOLTS PER STO PLANS 204,40 AND 204.50 4" MIN. PLAN VIEW , 78" MAX. • -• - • ' • ' SIZE TO CONVEY 1MYEAR IRST CELL SIZED FOR LADDER DESIGN FLOW WITHOUT 25% TO 35%OF FLOW RESTRICTOR OVERTOPPING, 6' MIN. WE VOLUME WATER WiTRY(�WSLR Q - 72'MIN. - INLET .' • 17 MIN. 7 MIN OUTLET WITH CAPACITY TO CONVEY 100-YEAR DESIGN 12'MIN. WETPOOL FLOW WITHOUT OVERTOPPING PTH SEE NOTE 7 (TYP.) , • �- BEjJAx Y MIN REMOVABLE BAFFLE 2-MIN Z'MIN. VALVE GRAVITY DRAIN (IF GRADE ALLOWS). PLACE AS LOW AS GRADE ALLOWS BUT MUST BE 6' BOTTOM SLOPE 0.5%-2% MIN, ABOVE THE BASE ELEVATION OF VAULT TOWARD INLET END WALLS OR ABOVE SEDIMENT STORAGE AREA SECTIONA BOTTOM SLOPE 05%-2%TOWARD OUTLET AVERAGE SEDIMENT STORAGE END OF SECOND CELL (RECOMMENDED) 17 MIN (FIRST CELL) ACCESS DOORS OR REMOVABLE PANEL, SEE NOTE 5 WATER QUALITY TWO) DESIGN WATER SURFACE (WSj 0 _ T MIN 4' MIN AVERAGE 17 SEDIMENT STORAGE (FIRST CELL) 5% MIN. I� 1 NOTES: SECTION B 1 THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2. THE VAULT SHALL BE SEPARATED INTO TWO CELLS BY A WALL OR A REMOVABLE BAFFLE IF A WALL OR NON REMOVABLE BAFFLE IS USED. A 5-FOOT x 1D-FOOT REMOVABLE MAINTENANCE ACCESS MUST BE PROVIDED FOR BOTH CELLS. 3. FOR VAULTS UNDER ROADWAYS. THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY. MULTIPLE STANDARD LOCKING MANHJ'.E COVERS MAY BE PROVIDED. SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER TO FACILITATE REMOVAL OF SEDIMENT- LADDERS AND HAND -HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE 4 MINIMUM DIAMETER FOR ALL ACCESS OPENINGS EXCEPT THOSE COVERED BY REMOVABLE PANELS. IS 36 INCHES 5. REMOVABLE PANEL SHALL BE AT GRADE. HAVE STAINLESS STEEL LIFTING EYES, AND WEIGH NO MORE THAN 5 TONS PER PANEL 6. VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION 7, WHEN CONNECTING TO A NEW PIPE. USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE e, SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING KNOT TOSCMEINTS) STD. PLAN - 254.00 PUBLIC WORKS COMBINED DETENTION AND Y DEPARTMENT WETVAULT Martin Pastucha 8/13/zo DATE 5.0' WIDE VENTILATION GRATE WITH 5' x 10' REMOVABLE, LOCKING ACCESS PANELS AND STEPS AT EACH END. INSTALL PER MANUFACTURER'S RECOMMENDATIONS LEAST FLOWING HIGH POINT OF "V" CHANNEL "V" CHANNEL BENEATH REMOVABLE BAFFLE WALL DETENTION WETVAULT - SECTION C SCALE: HORZ.• 1" = 10, VERT.: 1" = 5' NOTE PER GEOTECHNICAL REPORT BY EARTH SOLUTIONS LLC. DATED 12-20-2016. THE CONCTRACTOR SHOULD ANTICIPATE AND BE PREPARED TO RESPOND TO DISCRETE 0 TO MODERATE ZONES OF PERCHED GROUNDWATER DURING CONSTRUCTION. R-404106 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Michael Sippo 06/22/2023 ,O SURFACE WATER UTILITY ►� jfarah 06/22/2023 '5 DATE: Renton Subdivision 1-6-2023 17018 & 17022106th Avenue SE FlELDBOOK: PAGE. Renton WA 98055 � DRAWING N0: DETENTION TANK DETAILS SHEET: 7 OF:19