HomeMy WebLinkAboutT-404114A
i
A
Gj
Q
z
L,
POLE.
PAD'
—4"
JUNCTION BOX
LUMINAIRE CONCRETE
FOUNDATION
SIDE VIEW
LUMINAIRE CONCRETE PAD DETAIL
QNERAL NQjfS
1. LUMIN"IRF CONCRETE PAD SHALL BE USED IN AREAS
OUTSIDE OF SDEWALK
CONCRETE CLA55 FOR WMINAIRE CONCRETE, PAO SHALL
BE PER STD PLAN 135
TOP OF LUMINAIRE FOUNDATION, ELEVATION SHALL BE
LOCisTECh ATBOTTOM OF LUMINAIRE CONCRETE PAD'
ELEVATION OR, BOTTOM OF SIDEWALK' ELEVATION
4. LUMINAIRE POLE AND WNCT[ON BOX TYPE PER PLAN
5, LIJMINAIRf CONCRETE PAD ACCOMMODATES 'TYPE 1 AND
TYPE 2 ANCTION B�I)IES ONLY
F
0 0
-1
g a o
LUMINAIRE POLE * "L JUNCTION DQX
CONCRETE SMEWALI`
PLAN VIEW PER STD. PLAN t02
LUMINAIRE POI r
CONCRETE SIDEWALY
PERM PLAN 102
LUMINAIRE CONCRETE -STD. PLAN - 1 U
PUBLIC WORKS PADISIDEWALK AND ED;
DEPARTMENT JUNCTION BOX CONCRETE PAD Gregg A. ZimmjimA;w19 1
ar:znannzaFaaasc. DATE. I.
Call 2 Working Days Before You Dig
co
tilities Underground Location Cente
(ID,MT,ND,OR,WA)
lulu:lt4art�el�-ruc,u-4a�u-,�raa-aras�zr�yuu3�r
- - _ ,1
s'._ ...
, --a
0 r
w
�
�
-- 1
LLj
0 LIT
LLZ
dd 4`a"'d Fes'
V gq{ 0
(B-
—F
1 3. .....�-.., YI --.w s.�w ni-g
<_ I
UJI
1`I
L Yik-
LLA
_ S N g i .. ...�. --1i
a
2mz
qz
o
90
ELU
m.'
MIS
..a
U_
0 zy-<
zz W
u) w 0
-3
� �1 tCD. ---
�
w
a, �t5
Cr w
LL zUZ,z
LU
�o W
1-UU
►0�
LU ,w
at ¢
U.1
(a 0
x za
Z
UJ
w�a
2
its
r1i
c+t
s
z
0-
ca �
z
Uj
c�
Ud
z
m
ISERVICE CABINET I qTD PLAN - 122.1
1PUBUC WORKS DS
• DEPARTMMENT sid 'I 2f2712020
/V OR 1 AffE,
TPA FT -IC EXPER TH
11410 NE 124th St., #590, Kirkland, WA 98034
Phone:425.522.4118 Fax:425.522.4311
L
—11-23 1 No.
12:32
EPDXY
INLINE SPLICE
SPLICE KIT
rmt—,\\/\/ r1I I
WYE SPLICE
DIAMETER i
,"m Now,
�_7 4 — 7 /8" 7�
•A. LINE
I11 FUSE I
��yO ■■ OF
CUTTING RINGS
FUSE KIT
FUSE KIT & SPLICE KIT DETAILS
Y O� ADOPTED
CITY OF RENTON
Standard plans
LST DATE: 1 1 /5/96
DWG. NAME: JR-12 SP PAGE: J013
DocuSign Envelope ID: F41B6C7D-1A89-4D3E-83C3-E2FO224FAF96
POLE & BRACKET CABLE, #12
AWG. SPLICES BETWEEN FUSE
HOLDER AND LUMINAIRE FIXTURE
SHALL NOT BE ALLOWED
FUSE KITS QUICK
REFER TO WSDOT LOCKING DISCONNECT 3 AMP IN LINE
LID STANDARD DUTY FUSE KITS S.E.C. OR EQUAL —
JUNCTION BOX TYPES 1 &
2 STANDARD PLAN J-40.10
SPLICE KITS CLEAR EPDXY SPLICE
KITS ON ALL THRU WIRE RUNS —
CONCRETE PAD OR
SIDEWALK PER STD PLAN 120
24"(MIN) COVER #8 BARE COPPER
I GROUND WIRE
GROUND LUG
- GROUND
CLAMP
0 LUMINAIRE
#8 GREEN INSULATED WIRE
TO FIXTURE GROUND LUG
1 -#8 EQUIPMENT GROUND--] ----2- PVC CONDUIT II II
WIREW/GREEN INSULATION l� -A
FROM SERVICE CABINET CONCRETE FOUNDATION
2 - LIGHTING SYSTEM 5/8" x8' COPPER CLAD
WIRES TO CONTACTOR GROUND ROD
(SIZED AS REQ'D.)
NOTES:
1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY
VARY.
2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER
THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING
CONDUCTORS.
3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE
HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND
MAINTENANCE.
4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN
INSULATED WIRE OF THE SAME SIZE SHALL RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE
HANDHOLE.IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN INSULATED WIRE SHALL BE RUN
FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG.
LUMINAIRE ELECTRICAL STD. PLAN - 119
®� PUBLIC WORKS WIRING SYSTEM ;Ap OVED:
DEPARTMENT GAZ 5/22/2019
DATE
DowSlgn Emolope ID, 5D308A1A-2U4D-48E"823-8A283486565E
/- CONDIIAT ENTRANCE AREA
-a
t1Tt7
PLAN VIEW
SIDE TO FIT SIDE TO FIT'
CABINET
5 C7 1= D" V 0"
___-------I
-,GRADE LEVEL.
a c,v �
.a
a
. a
FRONT VIEW SIDE VIEW
ELECTRICAL SERVICE CABINET Fau-NDATiON
PTi]BLIC WO1RX
DEPARTMENT
SHIM TO PLUMB
-SEE NOTE 3
-I� QQPQ
AR EACPI f ORNER.
3/8" Dlt,MCTE.R PLASTIC DRAIN
SIDE VIEW'
CABINET DEPTH
—� — .—:._
44 BAR EACH
+ T AR it 4 CORNIER
lid : HOOPS
PLAN VIEW
CiFTR�0i4 R CABIN€_T_r�7UNi7T [ION
KOTE:S PER STD PLAN 1�62
CABINET FOUNDATION
DETAILS
STD. PLAN - 12,6.1 I
}()VELT. 3/1,3/Z01 I
"DATE
m
T-404103
IN =COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING +' OPERATIONMichael Sippo 06/22/2023 ' cZRANSPORTATIONbarnes 06/29/2023 ''
SURVEYED: SCALE: DATE:
VERTICAL: 1988 HORIZONTAL: NAD NAVD1983/1991 4 PENTON SUBDIVISION 1111123
DESIGNED: ASNOTED �� � C �J IT IY 0 F FIELABOOK:
VJG
DRAWN: RENTON 17018 & 17022 106THAVENUE NE PAGE:
VJG DRAWING N0:
ONE INCH DATUM RENTON WASHINGTON 98055
CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. IL3
LDH IF NOT ONE INCH ILLUMINATION PLAN
REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: OF:
LDH 14 19
b
O
b
O
O
a0
V