HomeMy WebLinkAboutP_2550ST-B(R)_Permit Set_20230705_v1Owner/DeveloperCentury Communities20000 N Creek Pkwy Ste. 201Bothell WA 98011(425) 275-5117Architect:Milbrandt Architects, Inc., P.S.25 Central Way, Suite 210Kirkland, WA 98033(425) 454-7130Structural Engineer:RB Engineers, Inc.1312 2nd St.Kirkland, WA 98033(425) 822-3009Civil Engineer:Core Design12100 NE 195th Street, Suite 300Bothell, WA 98011(425) 885-78771.Design Criteria: 2018 International Residential Code and the 2018International Mechanical Code with Washington State amendments.2.See Notes on Floor Plan Sheets for undercutting doors.3.Whole House Mechanical ventilation system:3.1.Exhaust Fan Ducting: Exhaust fans shall be ducted directly to the outside.Exhaust air outlets shall be designed to limit the pressure difference to theoutside and be equipped with backdraft dampers or motorized dampers inaccordance with the Washington state Energy Code. Exhaust fans shall betested and rated in accordance with the airflow and sound ratingprocedures of the Home Ventilating Institute ( HVI 915, HVI LoudnessTesting and Rating Procedure; HVI 916, HVI Airflow Test Procedure, andHVI 920, HVI Product Performance Certification Procedure, asapplicable.) Bathroom exhaust fans that are designed for intermittentexhaust airflow rates higher than the continuous exhaust airflow rates inTable R1505.4.3(3) shall be provided with occupancy sensors or humiditysensors to automatically override the fan to the high speed airflow rate.The exhaust fans shall be tested and the testing results shall be submittedand posted in accordance with Section M1505.4.1.6.3.2.Testing: Whole-house mechanical ventilation systems shall be tested,balanced and verified to provide a flow rate not less than the minimumrequired by Sections M1505.4.3 and M1505.4.4. Testing shall beperformed according to the ventilation equipment manufacturer'sinstructions, or by using a flow hood, flow grid, or other airflowmeasuring device at the mechanical ventilation fan's inlet terminals, outletterminals or grilles or in the connected ventilation ducts. Where requiredby the building official, testing shall be conducted by an approved thirdparty. A written report of the results of the test shall be signed by the partyconducting the test and provided to the building official and be posted inthe dwelling unit per Section M1505.4.1.7.3.3.Certificate: A permanent certificate shall be completed by the mechanicalcontractor, test and balance contractor or other approved party and postedon a wall in the space where the furnace is located, a utility room, or anapproved location inside the building. When located on an electrical panel,the certificate shall not cover or obstruct the visibility of the circuitdirectory label, service disconnect label, or other required labels. Thecertificate shall list the flow rate determined from the delivered airflow ofthe wholehouse mechanical ventilation system as installed and the type ofmechanical whole-house ventilation system used to comply with SectionM1505.4.3.1.3.4.System Controls: The whole-house mechanical ventilation system shall beprovided with controls that comply with the following:3.4.1.The whole-house ventilation system shall be controlled with manualswitches, timers or other means that provide for automatic operation ofthe ventilation system that are readily accessible by the occupant;3.4.2.Whole-house mechanical ventilation system shall be provided withcontrols that enable manual override off of the system by the occupantduring periods of poor outdoor air quality. Controls shall includepermanent text or a symbol indicating their function. Recommendedcontrol permanent labeling to include text similar to the following:"Leave on unless outdoor air quality is very poor." Manual controlsshall be readily accessible by the occupant;3.4.3.Whole-house ventilation systems shall be configured to operatecontinuously except where intermittent off controls and sizing areprovided per Section M1505.4.3.2.3.5.Calculations are based of an undistributed, unbalanced system as definedin the IRC where Cs =1.5. Distributed systems require outdoor supply airbe provided directly to all habitable spaces. Balanced systems requiresupply AND exhaust fans which are tested and balanced as having airflowrates within 10% or 5cfm of each other.3.6.Min required Whole House Fan (Qv=Qr * Cs) Qv= cfm * 1.5 = cfmrunning continuously. If intermittently operated system is installed,multiply required air flow rate by corresponding coefficient located intable M1505.4.3(3). 50% min. operational run time, switching on at leastonce every 4 hours. 1.0 max Sone rating.4.Whole House Mechanical Ventilation System Fan Efficacy: MechanicalVentilation system fans are required to meet the efficacy requirements ofTable R403.6.1 of the Washington state Energy Code. See table reproducedthis sheet.5.Supply outdoor air shall be brought into the unit through windows and shallbe screened or otherwise protected from entry by leaves or other outdoormaterials.6.All residential mechanical equipment installation must conform to the WAC173-60-040 Standards: Day 55 dBA -- Night 45 dBA.7.Specific requirements for the mechanical system, such as but not limited tothe duct size are to be determined by the mechanical bidder/design contractor.Minimum Required Local Exhaust Rates per section M1505.4.48.Kitchen Exhaust fans shall be per Table 1505.4.4(1)(100 cfm intermittent or 30 cfm continuous).9.Bathroom/Toilet Room Exhaust fans shall be(50 cfm intermitant or 20 cfm continuous).Shop drawings and calculations are required for:1. Roof trusses. See notes on sheet S1.1. Drawings and calculations will bereviewed and stamped by a State of Washington Registered Engineer.2. Electrical and Plumbing design and drawings.3. Pre-engineered and pre-fabricated deck and stair guardrail and handrailsystems. Drawings and calculations shall be reviewed and stamped by a Stateof Washington Registered Engineer.4. Mechanical design and drawings.Exterior walls >5-feet or perpendicularto property line:Floors separating private garage fromliving space:5/8" Type 'X' GWBgarage ceiling26 ga. steel ductingMembrane penetrations by ductsat garage:Garage-to-living space wall 2/D1 1/D1 6/D1See "Duct andVentilation Notes'Sheet A51/2" GWBnon-ratedDetailFire RatingAssemblySee sheet S3 for Design Loads.1.Comply with 2018 IRC and all applicable codes and ordinances of the localjurisdiction and the State of Washington.2.Do not scale drawings.3.Verify all rough-in dimensions for equipment provided in this contract orby others. All rough-ins shall be approved and fireblocking shall beinstalled prior to framing inspection.4.Verify size and location of and provide all openings through floors andwalls, furring, anchors, inserts, rough bucks and backing for surfacemounted items.5.Provide furring as required to conceal mechanical and electrical work in allfinished areas.6.All swinging doors not located by dimensions on plans, interior elevations,or details shall be 3" from face of stud to edge of rough openings orcentered between room partitions as shown.7.Plans are drawn assuming the following rough openings:Swinging doors: Nominal size +2".Bi-Fold doors: Nominal size +1-½".Bi-Pass doors: Nominal size +0".Windows: Nominal size +0".Sliding glass doors: Nominal size +0".8.Fill where required with earth free from organic material. Compact fill in12" layers maximum.9."Finish Floor" refers to the top of concrete slab or top of wood floorsheathing .10.Exterior walls shall be 2x6 studs at 16" o.c. and interior walls shall be 2x4studs at 16" o.c., unless noted otherwise.11.Unless otherwise noted, plan dimensions are to face of studs and face ofconcrete walls.12.Refer to interior elevations for cabinet and counter lengths, dimensions,countertop materials and detail reference. Verify all existing dimensionsbefore installation.13.Provide caulking between sole plates and subfloor and between rim joists atboth top plate and subfloor.14.Hydrants shall be in service prior to start of framing.15.Provisions shall be made for the control and drainage of surface wateraround building. IRC Sec R401.3.16.Milbrandt Architects is not responsible for construction means, methods,techniques or procedures, or for the safety precautions and programs inconnection with the work, and is not responsible for the failure of anycontractor or subcontractor to carry out the work in accordance with thevarious contract documents and or governing jurisdiction, regardless ofwhat is shown on these drawings.Project Name:CanopyProject Address:4196 Lincoln Ave NE, Renton, WA 98056Parcel Numbers:Parcel 1: 334570-0016Parcel 2: 334570-0015Parcel 3: 334570-0020Parcel 4: 334570-0018Parcel 5: 334570-0017Zoning:R-8Land UseResidential Medium DensityBuilding Code:2018 International Residential Code (Non-Structural)2018 International Building Code (Structural)2018 Uniform Plumbing Code2018 Washington State Energy CodeWashington State Amendments as modifiedand adopted by the local jurisdiction.Number of Stories: All buildings are 2-stories over basement(lowest level occurs below grade plane).Construction Type: V-B, These plans are for lots with 5'-0" minimum setbacks. For buildings located <5-0" from the property line, additional fire-protection measures will be required. (Including one-hour rated walls and other building elements).Floor Areas:1.Code: 2018 Washington State Energy Code.2.Compliance:Chapter 4 - using climate zone category 5 & marine 4 for allcalculations.All residential units shall comply with the Requirements By Component Table 402.1.1.Including but not limited to the following:Code RequirementsWindow U-Factor0.30-(0.28 used)Ceiling R-ValueR-49Wood Frame Wall R-ValueR-21 int.Floor R-ValueR-30-(R-38 used)Below Grade Wall10/15/21 int. + TBSlab R-Value R-10 perimeter (2 ft. depth); R-10 under entire slab"int." (intermediate framing) denotes standard framing 16" o.c. with headersinsulated with a min. of R-10 (see 6/D4 & 8/D4) and corners fully insulated (see 11/D2).Note to Bldg. Dept. An Energy Credit Checklist was submitted with Application.Medium Dwelling units shall comply with sufficient optionsfrom Table R406.2 & R406.3 so as to achieve 6.0 credits.3.Initial heating system using a heat pump that meets federal standards for equipmentlisted in table C403.3.2(1) or C403.3.2(2). Fuel Normalization Credit Option 2 (1.0credits)4.Efficient building envelope with R-38 floors and vertical fenestration of U=0.28 tocomply with Table 406.3, Option 1.3 (.5 credits).5.Reduce the tested air leakage to 3.0 air changes per hour maximum at 50 PascalsAND all whole house ventilation shall be met high efficiency fans (maximum 0.35watts/cfm) to comply with Table 406.3, Option 2.1 (.5 credits)6.Ductless split system heat pumps with no electric resistance heating in the primaryliving areas with minimum HSPF of 10.0 will be used to comply with Table 406.3,Option 3.6 (2.0 credits).7.An electric heat pump water heater meeting the standards for Tier III of NEEA'sadvanced heating specification to comply with Table 406.3, Option 5.5 (2.0 credits).7.1.Heat Pump Minimum features include: Energy Star Compliant, freeze protection,minimal use of resistance heating elements, compressor shut-down/ notification,10 year warranty, condensate management, simultaneous intake and exhaustducting capabilities, air filter management, and override and default modebehavior as per Section 6.1 of NEEA advanced water Heating Specification.Heat pump to have a minimum CCE of 2.6 and operate at a sound level dBA <55. Demand Response-Enabled is required.8.See D1 for Energy Notes.9.For insulation values see the Insulation Box on Sheet A3.10.No air conditioning will be provided.11.Applicable requirements for the 2018 WSEC:a) Posting of Certificate, WSEC 401.3A permanent certificate is required to be completed and posted on a wall in the spacewhere the furnace is located (or other approved location) and list the following information: R-values, U-Values, results from duct system air leakage testing, resultsfrom building envelope air leakage testing (blower door test), types and efficiencies ofheating, cooling, and service water heating equipment.b) Recessed luminaries, WSEC 402.4.5Recessed lights in the building thermal envelope shall be Type IC-rated and certifiedunder ASTM E283 as having an air leakage rate not exceeding 2.0 cfm (.944 L/s) whentested at a 1.57 psf (75 Pa) pressure differential and shall have a label attached showingcompliance with this test method. All recessed luminaries shall be sealed with a gasketor caulk between the housing and the interior wall or ceiling covering per R402.4.5.c) Building air leakage testing, WSEC 402.4.1.2All units shall be tested and verified as having an air leakage rate of not exceeding 5 airchanges per hour. Testing shall be conducted with a blower door at a pressure of 0.2inches w.g. (50 Pascals). For this test only, the volume of the home shall be theconditioned floor area in ft2 (m2) multiplied by 8.5 feet (2.6 m). Where required by thecode official, testing shall be conducted by an approved third party. A written report ofthe results of the test shall be signed by the party conducting the test and provided tothe code official per R402.4.1.2.d) Air leakage of fenestration, WSEC 402.4.3Windows and sliding glass doors shall have an air infiltration rate of not more than 0.3cfm per square foot (1.5L/s/m2), and swing door no more than 0.5 cfm per square foot(2.6L/s/m2), when tested according to NFRC 400 or AAMA/WDMA/CSA101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by themanufacture per R402.4.3e) Temperature Control, WSEC 403.1.At least one thermostat shall be provided for each separate heating and cooling system.Where the primary heating system is a forced-air furnace, at least one thermostat shallbe Energy Star certified and capable of controlling the heating and cooling system on adaily schedule. The thermostat shall allow for, at a minimum, a 5-2 programmableschedule (weekdays/weekends) and be capable of providing at least two programmableset back periods per day. This thermostat shall include the capability to set back ortemporarily operate the system to maintain zone temperature down to 55°F or up to85°F. The thermostat and/or control system shall have an adjustable deadband of notless than 10°F.(Exception: Systems controlled solely by a manually operated timer capable ofoperating the system for no more than two hours).f) Duct sealing, WSEC 403.3.2.Ducts are required to be sealed. Joints and seams shall comply with either theInternational Mechanical Code or International Residential Code, as applicable.g) Duct leakage testing, WSEC 403.3.3.Ducts shall be leak tested in accordance with WSU RS-33, using the maximum ductleakage rates specified.h) Mechanical System Piping Insulation, WSEC 403.4Mechanical system piping capable of carrying fluids above 105° F or below 55° F shallbe insulated to a minimum of R-6.h) Lighting (interior & exterior), WSEC 404.1.A minimum of 90% of all permanently installed lighting is required to behigh-efficacy.Fan Location Air Flow Min. EfficacyAir Flow RateRate Min.(cfm)(cfm/watt)Max. (cfm)HRV or ERVAny1.2 cfm/wattAnyRange HoodAny2.8 cfm/wattAnyIn-line FanAny2.8 cfm/wattAnyBathroom/Utility10 cfm1.4 cfm/watt<90Bathroom/Utility90 cfm2.8 cfm/wattAnyGarage 424 SFFront Porch 34 SFRear Patio39 SFFront Decks186 SFBasement Level Residence60 SFMain Level Residence 981 SFUpper Level Residence 1106 SFTotal Heated Building Area 2,147 SFLIST OF DRAWINGSA1 Cover SheetA3 Floor PlansA4 Interior Elevations & Stair PlansA5 Utility PlansA9 Exterior Elevations and SectionsA10 Specialty Details5582.5A7 Intentionally OmittedA8 Roof PlanA6 Architectural Foundation PlanS6 Upper Level Floor Framing Plan & Roof Framing PlanD1 DetailsD2 DetailsD3 DetailsD4 DetailsD5 DetailsD6 DetailsS1 Structural Notes/DetailsS2 Structural Notes/DetailsS3 General Structural NotesS4 Shear PlansS5 Foundation Plan & Main Level Floor Framing PlanPlan 2550 Single Tuck - B (R)CanopyRenton, WashingtonCentury CommunitiesA 55-Unit Single Family DevelopmentDescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A1Cover Sheet Plan 2550 Single Tuck - B (R)DJV/AJC/HDMPR19000387B23002951_V2REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISION PRO VISION WINDOW & DOOR WINPRO SERIES, U=0.26 & 0.28INSPECTOR TO VERIFY AND CONFIRM BLOWER DOORTEST RESULT IN THE FIELDDAIKIN MULTI HEAD DUCTLESSMINI-SPLIT HEAT PUMP SYSTEMMODEL NO. 4MXS36RMVJURHEEM ULTRA HYBRID ELECTRICHEAT PUMP 50 GALLON WATERHEATER,MODEL NO. PROH50 T2 RU350BMPROVIDE THE ENGINEER'S STAMPEDTRUSSES PLAN TO THE FIELD INSPECTORREVIEWEDPaul Wong 08/24/2023BUILDING DIVISIONTHIS SET OF REVIEWED PLANS MUST BE MADE AVAILABLE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. Note: This review is for the non-structural review onlyAPPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 GarageUP 15 R CRAWLSPACE ABOVEPATIO SLAB ABOVE17'-1"21'-11"5'-0" 11'-1012"26'-11"7'-612"17'-512"EntryPorchFLOOR ABOVE10'-0"9'-8"5'-4"25'-0"20'-234"6'-814" 6'-0"2-8 MTLINSUL SELFCLOSING10'-218"4'-4"8'-0"17'-0"612"16-0 7-0 SOHD3-0 7-0 PATIO 6-0 1-6 F AA9BA9CA99'-0" x 20'-0"PARKING SPACECEILING FINISH1 LAYER 58" TYPE 'X'GWB FIRE TAPEDWRAP BEAMS BELOW CEILING LEVEL.INSULATED FLOOR ABOVE20 MIN RATEDOOR9'-0" x 20'-0"PARKING SPACE2x8 FRAMINGFOR ELECTRICALENTRANCE8" CONCRETERETAINING WALL7'-412"Stor.2D15D51D1TYP.6/8D4SEE ELEV.TYP.19A10ABV.WH18D1SIM.17D3SIM.17D319D31'-0" 1'-6"1'-0"4'-0"1'-0"18'-0"1'-0"5'-6"DECK ABOVE12AD4SIM12AD4SIM20AD4SIM20A10ABV.AREA SUMMARYHeated SFUnheated SFInside Face*Inside Face*Basement60457First Floor981173Second Floor110651Total SF2147681* Side of exterior walls to which area was measuredPLAN 2550-ST-B(R)LOWER LEVEL PLAN1/4" = 1'-0"OPENTOABOVES & P DN16 R29'-712" 6'-1018"7'-758"12'-814"2'-512" 5'-212"5'-812"6'-4"26'-9" 6'-814"8'-512"11'-714"2'-112"4'-212"1'-1078"3'-958"3'-1"4'-10"4'-10"50'-0" 6'-0"3'-0"KitchenDiningLivingPwdr.PatioDeck2-0 4-0 SH2-6 4-0 F3-0 1-6 F6-0 1-6 F 3-0 5-0 FOVER3-0 2-0 F3-0 5-0 FOVER3-0 2-0 F6-0 8-0 SGD2-0 5-0 F 2-0 5-0 F 6-0 5-0 SL 2-4 HCW5'-612"2'-512"6'-9"1'-2"2'-512"3'-10"2'-912"3'-1012"3'-2"5'-6"3'-1012"8'-0"7'-5"WALL BELOWWALL BELOWFLOOR ABOVE AA9BA9CA9INSULATE FLOOROVER UNHEATEDSPACEINSULATE FLOOROVER UNHEATEDSPACELOW WALL +42"ABOVE STAIRNOSING ORLANDINGLOW WALL +42"ABOVE STAIRNOSINGFLOORABOVELOW WALL+42" A.F.F.TP18" TB6/8D4SEE ELEV.TYP.1D1TYP.3D1TYP.2-6 8-0 PATIO2-4 HCWBASE CAB. & OPT. DESK 3'-512"SOFFITDOWN TO8'-1" A.F.F.345118"x24" CRAWLSPACE ACCESS7'-612"17'-512"7'-612"6'-312"25'-0"8"8"7'-2"5'-1"14'-10"10'-2"1'-0"1'-0"1'-0"1'-0" 1'-0" 6" 5'-6"DW5-0 4-0 SL6'-812"5-0 5-0 SLFLOOR ABOVE12BD41D1TYP.8D2CRICKET13D52:1219A2ABV.20A1020D4SIM.20D4SIM.TYP.20D4SIM.ABV.4'-6" 14'-412"5 SHELVES2-6 HCWPLAN 2550-ST-B(R)MAIN LEVEL PLAN1/4" = 1'-0"2'-1112"3'-712"5'-1112"5'-6"6'-814"6'-1014"11'-512"13'-612"25'-0"1'-0"6'-10"3'-4"3'-6"49'-6"1'-0"11'-8"DeckMaster BedroomBedroom 2Bedroom 3HallOPENTOBELOWS & PS & PS & PS & PS & P5 SH.DN16 RDRYERWASHER2'-512"7'-1012"2'-0"12'-4"2'-412"7'-312"6'-312"6'-112"3'-5"1'-812"1'-5"3'-2"1'-1018"1'-67 8"11'-1112"5'-312"13'-612"15'-212"2'-512"7'-6"2'-0"2'-234"9'-412"1'-1114"2'-312"10'-512"2'-512"14'-10"10'-2"3'-1"4'-10"4'-10"2'-1"W.I.C.M. BathW.I.C.Bath 2Lndry.2-0 2-0 F2-0 2-0 F2-0 4-0 SH2-0 4-0 SH 2-0 2-0 F2-0 2-0 F3-0 5-0 F2-0 2-0 F2-0 2-0 F 2-6 HCW2-6 HCW2-4 HCW5-0 BYPASS2-4 HCW2-8 HCW2-4 HCW2-8 HCW2-4 HCW2-4 HCW2-4 HCW3-0 5-0 F3-0 5-0 F6-0 8-0 SGD7'-312"4'-2"3'-512"3'-2"6'-11"2'-9"2'-612"4'-2"5'-212"1'-8"2'-6"6"6'-5"6"5'-1112"4'-10"2'-1012"3'-312"6'-812"8'-2"3'-112"6'-5"WALL BELOWWALL BELOWAA9BA9CA922"x30"ATTICACCESSINSULATE FLOOROVER UNHEATEDSPACEINSULATE FLOOROVER UNHEATEDSPACE5' TUB &SHOWER18" BENCH60"x38"SHOWER60"x32"TUB18" TB24" TBTPTP24" TB10D13D1TYP.1D1TYP.1D1TYP.6/8D4SEE ELEV.TYP.2x6 OPT. BASECAB, OPT.SINK, OPT.UPPERSOPT.2NDSINK2-0 HCW678LOW WALL+42" A.F.F.3-0 5-0 F9'-1112"3'-712"6-0 5-0 SLEGRESS6-0 5-0 SLEGRESS4-0 1-6 FCEILING AT +10'-1" A.F.F.1D1TYP.20A1020D4SIM.TYP.1A9PLAN 2550-ST-B(R)UPPER LEVEL PLAN1/4" = 1'-0"DescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A3Plan 2550 Single Tuck - B(R) Floor PlansDJV/AJC/HDMALL BEDROOM, BATH AND LAUNDRY DOORS SHALLBE UNDERCUT A MINIMUM OF 1/2" ABOVE THEADJACENT FLOOR COVERING.OPENINGS BETWEEN GARAGE AND RESIDENCESHALL BE EQUIPPED WITH SOLID WOOD DOORSNOT LESS THAN 138" IN THICKNESS, SOLID ORHONEYCOMB STEEL DOORS NOT LESS THAN138" THICK, OR 20-MIN. FIRE-RATED DOORSPER IRC R302.5.1.INSULATE AND WEATHER STRIP ALL CRAWLSPACE ACCESS HATCHES.INSULATE AND WEATHER STRIP ALL ATTICACCESS HATCHES. PROVIDE A MINIMUM OF30" OF HEAD ROOM ABOVE ALL HATCHES.FRAMING: 2x6's AT 16" OC EXTERIOR WALLS 2x4's AT 16" OC INTERIOR WALLS UNLESS NOTED OTHERWISE.CONCEALED SPACES SHALL BE FIREBLOCKEDIN BOTH DIRECTIONS AT 10'-0" ON CENTERAND AT FLOORS. TYPICAL.FIREBLOCKING SHALL ALSO BE ATINTERCONNECTIONS BETWEEN VERTICAL& HORIZONTAL SPACES, BETWEEN STAIRSTRINGERS AT TOP & BOTTOM OF RUN,AT OPENINGS THROUGH CEILING & FLOORAND AT CHIMNEYS & FIREPLACES.ALL PLUMBING VENTS SHALL BE LOCATEDON REAR SIDE OF ROOF RIDGE.ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPINGROOMS SHALL HAVE A MINIMUM NET CLEAROPENING OF 5.7 SQUARE FEET. THE MINIMUMCLEAR OPENING HEIGHT DIMENSION SHALL BE 24".MINIMUM CLEAR OPENING WIDTH DIMENSION SHALLBE 20". SILL HEIGHT SHALL BE NOT MORE THAN44" ABOVE THE FLOOR.GLAZING SHALL CONFORM TO 2018 IRC SECTION R308.GLAZING IN ALL DOORS, AND ALL GLAZING WITHIN A 24" ARCOF EITHER VERTICAL DOOR EDGE, SHALL BE SAFETY GLAZING.PROVIDE STREET ADDRESS AT THE FRONT OF EACHRESIDENCE. USE 4" HIGH OR LARGER NUMBERS.N O T E SI N S U L A T I O NFLOORS OVER UNHEATED AREAS - R38ATTICS ABOVE ROOF CEILING - R49WINDOWS - U=0.28 OR BETTERGLAZED ENTRY DOORS - U=0.28WALL INSULATIONWALLS - R21 FIBERGLASS BATTS OR BLANKETSINSULATED METAL DOORS TO GARAGE - U=0.20SLAB ON GRADE - R10 FULLY INSULATEDSLAB. MIN. R-10 INSULATION AT HEATEDPERIMETER AND UNDER SLABSEE SHEET A4 FOR INTERIORELEVATIONS AND STAIR PLANSTUD WALL HEIGHTS:LOWER LEVEL: 8'-1" ABOVE F.FMAIN LEVEL : 9'-1" ABOVE F.FUPPER LEVEL :9'-1" ABOVE F.FSEE SHEET A9 FOR TOPOF WINDOW HEIGHTREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2SHOWER PAN INSPECTIONREQUIRED PER 2018 IRCSECTION P2503.6GLAZING IN WALLS AROUND BATHTUBSWHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES FROMTHE STANDING OR WALKING SURFACEIS REQUIRED TO BE SAFETY GLAZINGGLAZING ADJACENT TO STAIRS. GLAZING WHERETHE BOTTOM EDGE IS LESS THAN 36 INCHES ABOVETHE PLANE OF THE ADJACENT WALKING SURFACEOF STAIRWAYS, AND LANDINGS BETWEEN STAIRFLIGHTS MUST BE SAFETY GLAZINGINSPECTOR NOTICE:SEE STRUCTURAL SHEETS S4, S5 & S6 FORSHEAR WALL, FOUNDATION AND FRAMINGAPPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 123456789101112131415123456789101112131415167'-6" 9 TREADS @ 10" EA. 3'-4" LANDING 3'-4" LANDING3'-4"4 TREADS @ 10" EA.LOWER LEVEL TO MAIN LEVEL15 RISERS = 9'-158"EACH RISER = +/- 7.31"NOTE: STAIR WIDTH SHALL BE MIN. 36",RISERS SHALL BE MAX. 734",TREADS SHALL BE MIN. 10",STAIRS SHALL HAVE MIN. 6'-8" CLEAR HEADROOM,LANDINGS SHALL HAVE 36" MIN. RUN LENGTH.HANDRAIL DIAMETER 114"-2",HEIGHT 34"-38" ABV. STAIRNOSING AND 112" DISTANCEFROM THE WALL, TYP.LOW WALL AT+42" A.F.F.3'-2"3'-2"612"2"2"LOWERLEVELMAINLEVELMAIN LEVEL TO UPPER LEVEL16 RISERS = 10'-158"EACH RISER = +/- 7.60"MAINLEVELUPPERLEVEL3'-4"4 TREADS @ 10" EA.4'-012" LANDING4'-212" LANDING 5'-0" 6 TREADS @ 10" EA. 4'-012" LANDING 4'-012" LANDING2'-6"3 TRDS. @ 10" EA.312"2"2"2"3'-1012" 3'-1012"17D220D219D216D217D220D219D220D219D218D2UP 15 R UP16 RPLAN 2550-ST-B(R)STAIR PLANS3/8" = 1'-0"LIGHT BARMIRROR2-0 x 3-6℄3012"78"POWDER136" 96"KITCHEN3B27W3342WCC2442MICROWAVE W/EXHAUST FANRANGEW3942W3018KITCHEN4KITCHEN ISLAND5REFB3336"OPT. LAUNDRY63012" 6"BATH7VS30VS30VBD21FFMIRROR6-0 x 3-6LIGHT BAR℄CENTERLIGHT ONSINKSLIGHT BAR℄B36B36DB12M. BATH8℄MIRROR7-0 x 3-6LIGHT BARCENTERLIGHTON SINK℄LIGHT BAR84" 36" 6" 78" 6"B33B27DB12DWB27W2442W3918FOPEN TO BEYONDBS48W243636"96"W2436W3336W3336FB39DB12BS36FFFFEPFEPFPLAN 2550-ST-B(R)INTERIOR ELEVATIONS3/8" = 1'-0"W4242B18FFDescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A4Plan 2550 Single Tuck - B(R) Interior Elevations & Stair PlansDJV/AJC/HDMREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 PB3 33 TO ABOVEWPHOSEBIBSD/CM+48"+48"+48"+48"+48"TGarageAT CEILING: PREWIRE LOWVOLTAGE WIRE FORGARAGE DOOR OPENERAND ELECTRIC EYES.VERIFY LOCATION WITHOPENER INSTALLATIONWPEntryELEC PANELCONDENSERWHJELECMETER5'-0"+80"ABOVESLABBELLPLAN 2550-ST-B(R)LOWER LEVEL UTILITY PLAN1/4" = 1'-0"POWDERRANGE3TO BELOWTO ABOVE3333 3FSTACKTHERM ABV.SWITCHES+44"+44"+48"+44"TV+44"F R WALLMOUNTEDDUCTLESSMINI-SPITPPPWPKitchenDiningLivingPwdr.PatioHOSEBIBMWT +44"+44"OPEN TO ABV.SD/CMTCHIME+39"+44"+44"JDISP.TELWPDWPLAN 2550-ST-B(R)MAIN LEVEL UTILITY PLAN1/4" = 1'-0"+44"DRYERWASHERHALFHOTHALFHOTTELTVFVTRF+44"+44"3TO BELOW33SDSDSDSD/CMFVTRVTRWHFVTRVTRHALFHOTHALFHOTTVTVTWALLMOUNTEDDUCTLESSMINI-SPITTWPTT+48"+48"DeckMaster BedroomBedroom 2Bedroom 3HallW.I.C.M. BathW.I.C.Bath 2Lndry.WALLMOUNTEDDUCTLESSMINI-SPITWALL MOUNTEDDUCTLESS MINI-SPITLOWVOLTPANELOPEN TOBELOWT +39"+39"PLAN 2550-ST-B(R)UPPER LEVEL UTILITY PLAN1/4" = 1'-0"DescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A5Plan 2550 Single Tuck - B(R) Utility PlansDJV/AJC/HDMSMALL FLUORESCENTSTRIP LIGHTDUCT AND VENTILATION NOTESTHIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THEELECTRICAL CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICALCONTRACTOR'S DESIGN SHALL BE APPROVED BY THE OWNER ANDSHALL CONFORM TO THE APPLICABLE ELECTRIC CODE REGARDLESS OFWHAT IS SHOWN ON THIS DRAWING.ALL SWITCHES, OUTLETS AND ENVIRONMENTAL CONTROLS SHALL BEMOUNTED NOT LESS THAN 15" NOR MORE THAN 48"U.N.O. ABOVE FINISHED FLOOR AND SHALL BE ALIGNED VERTICALLY.APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELYFASTENED IN PLACE.WATER HEATERS SHALL BE ANCHORED OR STRAPPED AT POINTSWITHIN THE UPPER 1/3 AND LOWER 1/3 TO RESIST EARTHQUAKEMOTION.LIGHT FIXTURES THAT SERVE TO ILLUMINATE INTERIOR STAIRS SHALL BELOCATED IN THE IMMEDIATE VICINITY OF EACH STAIR LANDING ANDSHALL PROVIDE A MIN. LIGHTING LEVEL OF 1 FOOT-CANDLE MEASUREDAT CENTER OF TREADS AND LANDINGS PER IRC R303.7.SEE ENERGY NOTES ON SHEET D1.HEATING AND WATER HEATER SHALL BE FUELED BY ELECTRICITY.**CADET HEATERS SHALL BE PERMITTED UNDER WSEC SECTION 406.3,OPTION 3.6, FOOTNOTE A. MAX SIZE OF 0.5 WATTS/SQ. FT. OF HEATEDSPACE OR 500W, WHICHEVER IS LARGER.DUPLEX RECEPTACLE OUTLETSPLIT WIRED (SWITCH TOP HALF)DUPLEX RECEPTACLE OUTLETMICROWAVESINGLE RECEPTACLE OUTLET208v (R: RANGE, D: DRYER)DIRECTIONAL INCANDESCENTCEILING MOUNTED LIGHTINCANDESCENT RECESSEDCEILING LIGHTINCANDESCENT WALLMOUNTED LIGHTDOUBLE TUBE FLUORESCENTCEILING MOUNTED LIGHTINCANDESCENT CEILINGMOUNTED LIGHTRECESSED CEILINGEXHAUST FAN50 CFM MIN, 1.5 SONES,4" ROUND DUCTMICROWAVE OVEN/RANGEHOOD COMBINATION -EXHAUST FAN TO PROVIDEA MIN. OF 100 CFM.VENTILATION: SEE NOTES ON COVER SHEET.KITCHEN EXHAUST FAN TO BE 100 CFM MIN. AND SHALL VENT TOOUTSIDE.ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE FITTEDWITH A TIGHT FITTING BACKDRAFT DAMPER CAPABLE OF CLOSINGWHEN THE FAN IS NOT IN USE.DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE INSULATEDTO A MINIMUM OF R-8.TOP FLOOR EXHAUST FANS SHALL VENT THROUGH ROOF.MECHANICAL VENTILATING SYSTEMS IN BATHROOMS AND LAUNDRYROOMS SHALL EXHAUST DIRECTLY TO THE OUTSIDE.DUCTS PENETRATING OCCUPANCY SEPARATION BETWEEN GARAGEAND DWELLING, AND WITHIN THE GARAGE SHALL BE CONSTRUCTEDOF NO. 26 GAUGE SHEET STEEL.DRYER EXHAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" OPENINGON THE EXHAUST HOOD. ALL DRYERS SHALL EXHAUST A MAXIMUM OF200 CFM OR 100 SQUARE INCHES OF MAKEUP AIR SHALL BE PROVIDEDAT THE UTILITY ROOM DOOR AS SPECIFIED PER IMC SECTION 504.6. THEDRYERS SHALL BE GENERAL ELECTRIC. DRYER SHALL BE INSTALLEDACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS ONSITE.G E N E R A L N O T E STRACK LIGHTRECESSED CEILING WHOLE HOUSEEXHAUST FAN MEETING CFMREQUIREMENTS OUTLINED IN IRC SECTIONM1505.4CEILING MOUNTED LIGHT -PENDANTPCARBON MONOXIDE/SMOKE DETECTORUNDER CABINET LIGHTE N E R G Y N O T E SMETER CENTERSMOKE DETECTORTHERMOSTATELECTRICAL PANELDIMMER SWITCHTHREE WAY SWITCHSINGLE POLE SWITCHTELEVISION JACKTELEPHONE JACKJUNCTION BOXDUPLEX RECEPTACLE OUTLETTIMER SWITCHAUTOMATIC24 HR CLOCK TIMER -E L E C T R I C A L L E G E N DSD/CMWALL CADET HEATER**SCREENED WINDOWS ORWINDOWS W/ OUTDOORAIR INLETS; SEE VENTILATIONNOTES FOR MORE DETAILSREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2HEAT DETECTOR SHALL BE INSTALLED IN A CENTRALLOCATION OF THE GARAGE AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION PER 2018 WAC 51-51-0314 SECTION R314.2.3APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 312" CONC. SLAB+9'-1 5/8"-3"T.O.S.(VERIFYW/ CIVIL)+5'-0"T.O.W.VAPOR BARRIER OVER 6 MIL. 312" CONC. SLAB +8'-11 3/8"0'-0"3'-0"12'-612"26'-3"6'-2" 53'-2"25'-0"17'-9"21'-3"11'-0"1'-0"18'-8"5'-4"50'-0"25'-0"1'-1012"16'-3"1'-612"10"2"0'-0"3 1/2" DN SLOPE DN SLOPE 312" CONC. SLAB0'-0"0'-0"-4"T.O.S.0'-0"T.O.W.0'-0"17'-512"7'-612"+8'-11 3/8"+8'-11 3/8"+8'-7 3/8"T.O.S.T.O.W.SLOPE DN TOP OFSUBFLOOR312" CONC. SLAB2"5'-212" 10'-212"11'-012"612"4'-912"20'-212"5'-0"AA9BA9CA95'-4"DN SLOPE +8'-11 3/8"+8'-11 3/8"0'-0"+2'-0"+4'-0"+6'-0"0'-0"+2'-0"+4'-0"+6'-0"VERIFY WITH CIVILNOTE: FOR ALL STEPPED STEMWALLS, VERIFY WITH FINISHEDGRADING AND PROVIDE MIN.8" CLEARANCE FROM FINISHGRADE TO TOP OF STEM WALLHEIGHT. VERIFYREQUIREMENTS FOR STEPPINGWITH STRUCTURAL DRAWINGSCrawl Space312" CONC.SLABSTAIRS AS NEEDEDPER GRADE3D612D33D65D63D63D68D6SIM.19D31D32D320D37D311D310D34D38D33D36" 4'-0"+8'-11 3/8"1'-0"6"PLAN 2550-ST-B(R)FOUNDATION PLAN1/4" = 1'-0"DescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A6Plan 2550 Single Tuck - B(R) Architectural Foundation PlanDJV/AJC/HDMSEE STRUCTURAL SHEETS FOR ALL STRUCTURAL INFORMATION.ALL PONY WALLS IN CRAWL SPACE ARE 2x4 STUDSUNLESS NOTED.ALL WOOD IN CONTACT WITH CONCRETE OR EARTH SHALLBE PRESSURE-TREATED AND STAMPED BY AN APPROVEDAGENCY. ALL EXTERIOR COLUMNS, BEAMS ANDJOISTS EXPOSED TO THE WEATHER SHALL BEPRESSURE-TREATED.PROVIDE 4" PERFORATED FOOTING DRAINS AT PERIMETEROF ALL BUILDINGS.CRAWLSPACE VENTS PROVIDE 72.5 SQ. IN. NET FREE AREAPER OPENING.FINISHED SURFACE AROUND THE BUILDING SHALL SLOPEAWAY NO LESS THAN 2% FOR AT LEAST 5 FEET.COVER CRAWL SPACE FLOOR WITH MIN. 6 MIL. POLYETHYLENEVAPOR BARRIER.CRAWLSPACE VENTELEVATION AT TOP OF CONCRETEDOWNSPOUT: PROVIDE TIGHT LINE & RISER BOOTFINISH SLAB ELEVATION+20"+33"F O U N D A T I O N N O T E SFULLY INSULATED SLAB. MIN. R-10UNDERSLAB AND AT PERIMETERWHERE SHEAR WALLS REQUIRE PLYWOOD, IT SHALL BE APPLIED TO SIDE OF STUDWALL SHOWN AND SHALL CONTINUE ABOVE AND BENEATH OPENINGS.SOME PLYWOOD SHEAR WALLS MAY REQUIRE 3 x 4 STUDS. SEE SHEAR WALLSCHEDULE SHEET S1.1.SHEAR WALLS CALLED OUT ON THE PLANS SHALL EXTEND TO THE PERIMETERFOUNDATION WALL.SEE PLAN FOR SHEAR WALL TYPE, OTHERWISE ALL EXTERIOR WALLS SHALL BESHEATHED WITH P6 SHEAR WALL TYPE.SHEAR WALL WITH FORCE TRANSFERAROUND WINDOWS. SEE 8/S1.2 FORDETAILS.P6P6SHEAR WALL- INDICATES EXTENT OF SHEAR WALLHDHOLDOWN TYPE - SEE 10/S1.2 FOR SCHEDULESHEAR WALL TYPE - SEE 14/S1.1 FOR NAILINGS H E A R W A L L N O T E SREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 AA9BA9CA9R JR JR JR JR JR JR JR JR JR JR JR JAREA 1R JR JR JR JR JR J3:123:123:121'-0" 1'-0"1'-0"1'-0"1'-0"1'-0" 1'-0"1'-0"1'-0"1D22D22D210D21D218A10PLAN 2550-ST-B(R)ROOF PLAN1/4" = 1'-0"AREA 2R JROOF VENTING CALCULATIONSAreaDescriptionAttic Area(SF)VentingRatioRequiredVenting(SI)Low Jacks(Qty)High Jacks(Qty)Venting Provided (SI)* % of req'd50.050.0Lower%Upper%Total%*AREA 11,1861/3005699845053%40047%850149%AREA 2521/15050115050%5050%100200%1-PROFILE 12-PROFILE 23-PROFILE 39' PLATE HEIGHT9' PLATE HEIGHT25'-0"12312310' RAISED PLATE1'-0"5'-3"1239' PLATE HEIGHT25'-0"1236'-3"25'-0"15'-0"1/8" = 1'-0"PLAN 2550-ST-B(R)ROOF TRUSS PROFILES1/4" = 1'-0"PROFILE 1PROFILE 2PROFILE 3DescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A8Plan 2550 Single Tuck - B(R) Roof PlanDJV/AJC/HDM5.9 SQ.IN./SF NET FREE AREAVENTED VINYL SOFFITROOF SLOPE AS NOTEDRJ50 SQ.IN. NET FREE AREADOWNSPOUT LOCATIONGUTTER (DOUBLE LINE)EAVE VENTINGBUILDING OUTLINEROOF JACK2.4 SQ.IN./L.F. NET FREE AREACHIMNEY FLUER O O F L E G E N DREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 FIBER-CEMENTLAP SIDING, 7"REVEAL1239'-1"1'-05 8"9'-1" 19'-258"TOP OF PLATEUPPERLEVEL F.F.MAINLEVEL F.F.8D4TYP.12BD48D22D211D2TYP.2D5TYP.PLAN 2550-ST-B(R)REAR ELEVATION1/8" = 1'-0"25'-718" 29'-134"AVERAGE FINISHGRADE 161.13COMPOSITIONSHINGLEROOFINGENGINEERED WOOD‘RUSTIC SERIES’ BYWOODTONE - SUMMER WHEAT9'-1"1'-05 8"9'-1"1'-058"8'-1"28'-414"LOWERLEVEL F.F.MAINLEVEL F.F.UPPERLEVEL F.F.TOP OFPLATECA9BA98D4TYP.19A102D5TYP.11D2TYP.FIBER-CEMENTLAP SIDING, 7"REVEAL2x BELLY BAND19A10PLAN 2550-ST-B(R)GARAGE SIDE ELEVATION1/8" = 1'-0"25'-718"AVERAGE FINISHGRADE 161.133'-2"3'-2"AVERAGE WALLPLATE HEIGHTAT SHED ROOF(MAX. 30'-0")FIBER-CEMENTLAP SIDING, 7"REVEALCOMPOSITIONSHINGLEROOFING2x10 BELLYBAND9'-1"1'-058"9'-1"TOP OFPLATEUPPERLEVEL F.F.MAINLEVEL F.F.1'-058"8'-1"28'-414"LOWERLEVEL F.F.CA9BA98D4TYP.10D21D25D22D5TYP.7D53D5TYP.TYP.6D4TYP.11D2TYP.12BD418A1020AD4SIM.PLAN 2550-ST-B(R)STAIR SIDE ELEVATION1/8" = 1'-0"+9'-1"+9'-1"28'-918"AVERAGE WALL PLATEHEIGHT AT SHED ROOF(MAX. 30'-0")3'-2"AVERAGE FINISHGRADE 161.1325'-718"3'-2"GLAZING PERCENTAGE CALCULATION:TOTAL FACADE AREA = 814 SF814 SF x 25% = 204 SFTOTAL GLAZING = 226 SF9'-1"1'-058"9'-1"TOP OF PLATEUPPERLEVEL F.F.MAINLEVEL F.F.1'-058"8'-1"28'-414"LOWERLEVEL F.F.15 SF48 SF15 SFAA95D56D511 SF16 SFENGINEERED WOOD ‘RUSTICSERIES’ BY WOODTONE - SUMMER WHEATFIBER-CEMENTPANEL SIDING12325 SF15 SF48 SF15 SF6 SF6 SF6 SF32'-614"2D211D2TYP.12AD4SIM.20A1019A1020A10TYP.TYP.12AD4SIM.20D4SIM.18A1020D4PLAN 2550-ST-B(R)STREET ELEVATION1/4" = 1'-0"6D4TYP.Lot 31A154.25North: (B+C)/2 =167.25B167.00West: (C+D)/2 =161.63C167.50South: (D+A)/2 =155.00D155.75East: (A+B)/2 =160.63Average Grade Plane =161.13167.525'-718"AVERAGE FINISHGRADE 161.13158.528'-918"AVERAGE WALL PLATEHEIGHT AT SHED ROOF(MAX. 30'-0")3'-2"3'-2"DeckW.I.C.EntryLivingDeckM. BedBed 3Pwdr.HallCRAWLSPACE9'-1"1'-058"9'-1"TOP OFPLATEUPPERLEVEL F.F.MAINLEVEL F.F.1'-058"8'-1"28'-414"LOWERLEVEL F.F.5D1TYP.5D1TYP.12AD1TYP.9D1TYP.3D1TYP.19D220D27'-0"19D216D28D1TYP.13D414D411D1TYP.8D210D3ASNEEDED4D33D67D12D22D28D21D1TYP.13D5Attic9D120A1020A10SIM.PLAN 2550-ST-B(R)SECTION A1/8" = 1'-0"StairLndry.BathDiningGarage9'-1"1'-058"9'-1"TOP OF PLATEUPPERLEVEL F.F.MAINLEVEL F.F.1'-058"8'-1"28'-414"LOWERLEVEL F.F.12BD15D16D1TYP.8D117D217D220D220D23D1TYP.12BD11D1TYP.19D320D316D3SIM.7'-0"1D25D29D1TYP.PLAN 2550-ST-B(R)SECTION B1/8" = 1'-0"123M. BathLiving9'-1"1'-058"9'-1"TOP OF PLATEUPPERLEVEL F.F.MAINLEVEL F.F.1'-058"8'-1"28'-414"LOWERLEVEL F.F.6D55D55D1TYP.6D112AD19D1TYP.1D1TYP.12D2TYP.M.Bed19A103D3SIM.1D210D210'-1"RAISED PLATEUPPERLEVEL F.F.PLAN 2550-ST-B(R)SECTION C1/8" = 1'-0"123DescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A9Plan 2550 Single Tuck - B(R) Exterior Elevations and SectionsDJV/AJC/HDMREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 1-1/2" = 1'-0"SECTIONBOXED BEAM @ FLOORTYP. EXTERIORWALL CONSTRUCTIONBEAM PER STRUCTURAL.WHERE NO BEAM ISINDICATED AT SIM.CONDITION, FRAMEFALSE BOXED BEAM TOMATCH DIMENSION.62NOTE: FLOORFRAMING PERPLANS1D1FIBER CEMENTSOFFIT1'-0"BOX OUT BEAMTO FLUSH OUTWITH COLUMN22SIDING (PER ELEV)OVER W.R.B. OVERPLYWOODSHEATHING1-1/2" = 1'-0"SECTIONDECK EDGE @ HDRMETAL DRIP FLASHINGGUARD RAIL,SEE DETAIL 17/D4RIP TOP OF JOISTS 14":12"11D1VENTED FIBERCEMENT SOFFITFIBER CEMENT PANELINSTALLED PER MANUF.OVER W.R.B. OVERPLYWOOD SHEATHINGHDR PERSTRUCTURALADD SPACERS ASNEEDED TO FLUSHOUT BACK OF BEAMWITH BACK OFWRAPPED COLUMN1-1/2" = 1'-0"HIGH DECK/PORCH EVEHDR PER STRUCT.FIBERCEMENTSOFFITBOARD9D1SIDING PER ELEV. OVERPLYWOOD SHEATHINGBOX OUT TOMATCH WIDTH OFDECK COLUMN22SLOPEPER PLAN12TRUSSESEVE PER DETAIL 10/D2VENT BLOCKING201918DescriptionDateNo.Revisions5-4-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:A10Specialty Details 2550-ST-BDJV/AJC/JDPREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 REVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 1-1/2" = 1'-0"SECTIONFLOOR OVER GARAGEHOUSE INTERIORTJIGARAGEFLOOR INSULATION34" FLOORSHEATHING58" TYPE 'X' GWBFIRETAPE ONLYFLOOR INSULATION58" TYPE 'X' GWBFIRETAPE ONLYFLOOR TRUSSNOTE: FLOORFRAMING PERPLANS3" = 1'-0"PLANTYPICAL EXTERIOR WALL12" GWB OVER 2x6 STUDS AT 16" OCPROVIDE PVA WALL PRIMER AS VAPORBARRIER ON INSIDE FACE OF GWB.BUILDING PAPER SHALL BEEQUAL TO THAT PROVIDED FORIN IRC R703.2SIDING OVER BUILDING PAPEROVER OSB SHEATHINGBATT INSULATION(NO INSULATION @ UNHEATED SPACE)626258" GWB OVER 2x6 STUDS AT 16"O.C. WITH INSULATIONPROVIDE PVA WALL PRIMER ASVAPOR BARRIER ON INSIDEFACE OF GWB.58" GWBFIRETAPE ONLYPROVIDE OSB BETWEENSTUD AND GWB WHEREINDICATED ON FRAMINGPLANS.58" GWB OVER OSB,FIRETAPE ONLY.INCREASE GWB NAILLENGTH 58".6262INTERIORGARAGE 3" = 1'-0"PLANINTERIOR WALL AT GARAGEPLANTYP. INTERIOR WALL3" = 1'-0"2TAPE & PAINT GWB, TYP.12" GWBBOTH SIDES12" GWB OVER SHEARPANELS WHERE INDICATEDFOR SHEAR WALLNOTE: SHEAR DIAPHRAGMMAY OCCUR ON EITHERSIDE OF THE WALL OR ONBOTH SIDESGlazing U-values shall be determined in accordance with NFRC 100.Windows and SGD shall be double glazed vinyl type with the U-values indicated onfloor plans.All exterior doors or doors serving as access to an enclosed unheated area shallbe weatherstripped to limit leakage around their perimeter when in a closed position.The thermal transfer characteristics of insulated doors shall bedetermined per NFRC 100.Roof/Ceiling insulation: Open-Blown or poured loose fill insulation may beused in attic spaces where the slope of the ceiling is not more than three feet intwelve and there is at least thirty inches of clear distance from the top of the bottomchord of the truss or ceiling joist to the underside of the sheathing at the roof ridge.When eave vents are installed, baffling of the vent openings shall be provided so asto deflect the incoming air above the surface of the insulation. Baffles shall be rigidmaterial, resistant to wind driven moisture. When feasible, the baffles shall beinstalled from the top of the outside of the exterior wall, extending inward, to apoint six inches vertically above the height of noncompressed insulation, and twelveinches vertically above loose fill insulation.Where the ventilation space above the insulation is less than an average oftwelve inches roof ceiling assemblies shall be provided with a vapor retarder. Facedbatt insulation where used as a vapor retarder shall be face stapled.Vapor retarders shall not be required in roof/ceiling assemblies where theventilation space above the insulation averages twelve inches or greater.Vapor retarders shall be installed on the warm side of the insulation.When installed in the building envelope, recessed lighting fixtures shall meet therequirements specified in Section 402.4.5 WSEC 2018:Recessed luminaires installed in the building thermal envelope shall be TypeIC-rated and certified under ASTM E283 as having an air leakage rate not more than 2.0cfm when tested at a 1.57 psf pressure differential and shall have a label attachedshowing compliance with this test method. All recessed luminaires shall be sealed with agasket or caulk between the housing and the interior wall or ceiling covering.All insulation materials shall be installed according to the manufacturer's instructions toachieve proper densities, and maintain uniform R-values. Substantial contact of the insulationwith the surface being insulated is required. Insulation shall be installed in a manner which willpermit inspection of the manufacturer's R-value identification mark.Where required, insulation shall be installed with clearances according to manufacturer'sspecifications. Insulation shall be installed so that required ventilation is unobstructed. Forblown or poured loose fill insulation clearances shall be maintained through installation of apermanent retainer.For specific R-Values, see insulation note on floor plans.Crawl space foundation vents shall be placed so that the top of the vent is below the lowersurface of the floor insulation. When foundation vents are not placed so that the top of thevent is below the lower surface of the floor insulation, a permanently attached baffle shall beinstalled at an angle of thirty degrees from horizontal, to divert air flow below the lowersurface of the floor insulation.A ground cover of six mil (0.006 inch thick) black polyethylene or approved equal shallbe laid over the ground within crawl spaces. The ground cover shall be overlapped twelveinches minimum at the joints and shall extend to foundation wall.Floor insulation shall be installed to maintain permanent contact with the underside ofthe subfloor decking. Insulation supports shall be installed so spacing is no more thantwenty-four inches on center.Floors separating conditioned space from unconditioned space shall have a vaporretarder installed. Vapor retarder shall be installed on the warm side of the insulation. Thevapor retarder shall have a one perm dry cup rating or less (i.e. four mil. polyethylene or kraftfaced material). The floor sheathing may be used as the vapor retarder if rated (and sostamped) at one perm (max.) Otherwise place vapor retarder on top of joists before placingsheathing.All wall insulation shall fill the entire cavity. Exterior wall cavities isolated during framingshall be fully insulated to the levels of the surrounding walls. All faced insulation shall be facestapled to avoid compression.Walls separating conditioned space from unconditioned space shall have a vaporretarder installed. Faced batt insulation shall be face stapled. Vapor retarder shall be installedon the warm side of the insulation.These air leakage notes apply to those locations separating outdoor ambient conditionsfrom interior spaces that are heated or mechanically cooled.Exterior joints around windows and door frames, openings between walls and foundation,between walls and roof and wall panels; openings at penetrations of utility services through walls,floors and roofs; and all other openings in the building envelope for all occupancies shall besealed, caulked, gasketed, or weatherstripped to limit air leakage. Other exterior joints and seamsshall be similarly treated, or taped, or covered with moisture vapor permable housewrap.Openings that are required to be fire resistive are exempt from air leakage restrictions.Recessed Lighting FixturesINSULATION AND ENERGY NOTESInsulation - GeneralFloorsExterior WallsAir LeakageDoorsWindows:Roof/Ceilings: All water heaters shall meet the requirements of the 1987 National Appliance EnergyConservation Act and be so labeled. All electric water heaters in unheated spaces or on concrete floors shall be placedon an insulated surface with a minimum thermal resistance of R-10, and a minimumcompressive strength of 40 psi or engineered to support the appliance. Water heaters shall be equipped with automatic temperature controls capable ofadjustment from the lowest to the highest acceptable temperature settings for theintended use. Temperature setting range shall be set to 120°F. or 49°C.A separate switch shall be provided to permit turning off the energy supplied toelectric water heaters. A separate valve shall be provided to permit turning off theenergy supplied to the main burner(s) of all other types of service water heater systems.Water HeatersCrawl Spaces121-1/2" = 1'-0"SECTIONTYP. SLAB-ON-GRADELIVING UNITSGARAGES & PATIOSAB4" CONCRETE SLABO/ R-10 RIGID INSULATIONO/ 10 MIL VAPORBARRIER O/ 4" FREEDRAINING MATERIALO/ COMPACTED FILL312" CONCRETESLAB O/ 4" FREEDRAINING MATERIALO/ COMPACTED FILL*FREE DRAINING MATERIAL TO BE PER CURRENT GEOTECHNICAL REPORTRECOMMENDATIONS3" x 12" GWBSOLIDBLOCKING1'-4"214" TRIMLOOSE FILLINSULATIONBATTINSULATIONWEATHERSTRIPPING 1-1/2" = 1'-0"SECTIONATTIC ACCESS12" GWB CEILINGROOF TRUSSROOF TRUSSES AT 24" OC 1-1/2" = 1'-0"SECTIONTYPICAL ROOF/CEILING(1) LAYER 12" GWB. PROVIDE PVAWALL PRIMER AS VAPOR BARRIERON INSIDE FACE OF GWBLOOSE FILLINSULATIONROOF TRUSSES AT 24" OCVENTED FIBER CEMENT SOFFITAT EXTERIORDECK/PORCHAT INTERIORSPACE 3" = 1'-0"PLAN1-HOUR WALL22SIDING OVER 58" TYPE 'X' GYPSUMSHEATHING OVER EXTERIOR WOODSHEATHING WHERE INDICATED58" TYPE 'X' GWBOVER 2x STUDS AT 16" O.C.NOTE: CONTINUE OSBSHEATHING TO THENEAREST CORNERSIDING OVER 58" TYPE 'X'GYPSUM SHEATHING1-HR GA File No. WP8105Exterior Side - one layer 58" Type 'X' gypsum sheathing, 48" wide applied parallel to studswith galvanized roofing nails, 134" long, 0.120" shank, 716" or 12" heads, 7" o.c. in field, 4"o.c. perimeter. Joints of gypsum sheathing may be left untreated. Exterior cladding to beattached through sheathing to studs. Wallboard and sheathing nailed to top and bottomplates at 7" o.c.Interior Side - one layer 58" Type 'X' gypsum wallboard or water resistant backer board orveneer base applied parallel with or at right angles to 2x4 wood studs, 24" o.c. with 6dcoated nails 178" long, 0.0915" shank, 14" heads, 7" o.c.c (load bearing)17841D15D1GWB CEILING MUSTCONTINUE THRUTO MAINTAINFLOOR RATING2x4 BLOCKINGAT 24" O.C.CONCEALED SPACESSHALL BE FIRESTOPPEDIN BOTH DIRECTIONSAT 10'-0" ON CENTERSCREW TO BLOCKING3D1COFFERED CEILINGSECTION1 1/2" = 1'-0"24242458" TYPE 'X' GWBOVER 2x4 FRAMING1-1/2" = 1'-0"SECTIONTYPICAL FLOOR 34" T&G PLYWOODSUBFLOOR OVERFLOOR JOISTS12" GYPSUMCEILING BOARDTJI. SEE FRAMING PLANSFOR TYPE AND SPACINGDUCT34" T&G PLYWOOD SUBFLOOR OVER OPENWOOD TRUSS PER PLAN U.N.O.(ADD INSULATION WHEN SEPARATINGUNIT FROM UNHEATED SPACEDUCT12" GYPSUMCEILING BOARDNOTE: FLOORFRAMING PER PLANS1-1/2" = 1'-0"SECTIONINTERMEDIATE STAIR LANDING34" T&G PLYWOOD SUBFLOOROVER 2x FLOOR FRAMING@ 16" O.C. U.N.O.12" CEILING GWB(PROVIDE 58" TYPE 'X'GWB OVER GARAGE)INTERIORINTERIOR/STORAGEPROVIDE 2x FURRINGBENEATH LANDING TOACCOMMODATE R-38INSUL. OVERUNHEATED SPACES.2102102109615231011WATERPROOF DECKING OVER1/2" & 3/4" EXT. GRADE PLYWOOD2102102x10 JOIST@ 16" O.C.VENTED FIBERCEMENT SOFFIT 1-1/2" = 1'-0"SECTIONDECK FLOORMIN.R-10 IMPERMEABLE INSULATION INSTALLED IN DIRECTCONTACT WITH UNDERSIDE OF ROOF SHEATHINGINSULATION TO BE A CLASS II VAPOR RETARDER OR TO HAVE ACLASS III VAPOR RETARDER IN DIRECT CONTACT WITH THEUNDERSIDE OF THE INSULATIONFILL REMAINING VOID WITH BATT INSULATION TO ACHIEVE AMIN. R-38 VALUE (COMBINATION OF IMPERMEABLE AND BATT)(1) LAYER 12" G.W.B.PVA PRIMER AT THIS LOCATION TO HAVE APERM RATING GREATER THAN 1.0 SO AS TO NOTQUALIFY AS A VAPOR RETARDERINTERIOREXTERIORCOMPOSITION SHINGLES ATTACHED USING GALVANIZED NAILSOVER (2) LAYERS ROOF FELT OVER ROOF SHEATHING1-1/2" = 1'-0"SECTIONROOF/CEILING @ RAFTERSRAFTERS PERSTRUCTURAL131-1/2" = 1'-0"SECTIONFLOOR OVER CRAWL SPACEHOUSE INTERIORPROVIDE VAPOR BARRIER HERE UNLESSFLOOR SHEATHING IS A RATED BARRIER. SEENOTES THIS SHEET.34" FLOORSHEATHINGTJINOTE: FLOORFRAMING PERPLANS22CRAWL SPACEFLOOR INSULATION7DescriptionDateNo.Revisions4-6-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:D1Details DJV/AJC/JDPREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 1-1/2" = 1'-0"SECTIONSTAIR DETAILSEE UNIT STAIR PLANSFOR RISER AND TREADDIMENSIONS.TR 1"PROVIDE 2xFURRING BENEATHSTRINGERS TOACCOMMODATER-38 INSUL. OVERUNHEATED SPACES.42626234" FLOOR SHEATHING OF118" PREFORMED TREADS12" GWB(1) LAYER 58"TYPE X GWBAT GARAGE1-1/2" = 1'-0"SECTIONWALL/FLOOR DETAILWALLINSULATIONAT RIM5D16D11D1LSL RIMAT GARAGE626262FIN. FL.EXTEROR WALLNOTE: FLOORFRAMING PERPLANSTYPICAL EXTERIOR CORNER3" = 1'-0"PLANFIBER CEMENT SIDINGINSTALL PER MANUF.OUTSIDE CORNER X TRIMINSTALL PER MANUF.W.R.B.SECOND LAYER W.R.B.AT CORNER, TYP.EXTERIOR WALL SHEATHING6262621D1THERMAL INSULATIONINTERIOREXTERIORFULLY INSULATE CORNERTOP OF STAIR DETAILSECTION1 1/2" = 1'-0"SEE STAIR PLANSFOR RISER ANDTREAD DIMENSIONS(1) LAYER 58"TYPE X GWBAT GARAGE2 x 12 STRINGERS AT 12" O.C.118" FLOOR SHEATHINGTR1x8 1"5D1PROVIDE 2xFURRING BENEATHSTRINGERS TOACCOMMODATER-38 INSUL. OVERUNHEATED SPACES.CONNECTIONSPER STRUCTURALUNITNOTE: FLOORFRAMING PER PLANS6D11-1/2" = 1'-0"SECTIONCANTILEVER FLOORPER PLANFLASHINGTRIM PERELEVATIONSTYP. FLOOR CONSTRUCTION5D1TYP. EXTERIORWALL CONSTRUCTIONBEAM PERSTRUCTURAL626262NOTE: FLOORFRAMING PERPLANS1D1FIBER CEMENTSOFFIT811BOTTOM OF STAIR @ LANDINGSECTION1 1/2" = 1'-0"(1) LAYER 58" TYPE 'X'GWB AT GARAGE2x12 STRINGERS AT 12" O.C.118" FLOORSHEATHINGTR 1"1x88D1SEE UNIT STAIRPLAN FOR TREADAND RISER DIMENSIONSPROVIDE 2xFURRING BENEATHSTRINGERS TOACCOMMODATER-38 INSUL. OVERUNHEATED SPACES.PROVIDE 2x FURRING BENEATH LANDINGTO ACCOMMODATE R-38 INSUL. OVERUNHEATED SPACES.CONNECTIONSPERSTRUCTURAL10210220TOP OF STAIR @ LANDINGSECTION1 1/2" = 1'-0"(1) LAYER 58"TYPE X GWBAT GARAGE2x12 STRINGERS AT 12" O.C.1 1/8" FLOOR SHEATHINGTR1x8 1"8D1SEE UNIT STAIRPLAN FOR TREADAND RISER DIMENSIONSPROVIDE 2xFURRING BENEATHSTRINGERS TOACCOMMODATER-38 INSUL. OVERUNHEATED SPACES.PROVIDE 2x FURRINGBENEATH LANDING TOACCOMMODATE R-38INSUL. OVERUNHEATED SPACES.102102102UNITCONNECTIONSPER STRUCTURAL19 1-1/2" = 1'-0"SECTIONBOTTOM OF STAIRFURR DOWNCEILING ANDPROVIDE R-38 INSUL.OVER UNHEATEDSPACES.(1) LAYER 58" TYPE XGWB AT GARAGE2x12 STRINGERSAT 12" O.C.118" FLOORSHEATHINGT1x81"2x BLOCKINGR5D1BEAM PER STRUCTURALSEE STAIRPLANS FOR RISERAND TREADDIMENSIONS.6D11" = 1'-0"SECTIONROOF AT FLOOR CANTILEVERTRUSS HANGERBEAM PER STRUC.MONO TRUSSESAT 24" O.C.PORCH ROOF2x BLKG.SIDINGOVER EXTR.WALL SHTG.PERFORATEDFIBER-CEMENT SOFFIT5D11D1PER PLANROOFING OVERROOF SHEATHINGWALL-TO-ROOFFLASHING12PORCH/DECKINTERIOREXTEROR WALLNOTE: FLOORFRAMING PERPLANS2626261215SEE UNIT STAIR PLANS FORRISER AND TREAD DIMENSIONS(1) LAYER 58" GWB(AT GARAGE)2x12 STRINGERSAT 12" O.C.118" FLOORSHEATHINGTBOTTOM OF STAIR @ CONC.1x81"2x12 P.T.BOTTOM PLATER 12AD1SECTION1 1/2" = 1'-0"1718167101-1/2" = 1'-0"SECTIONUPPER ROOF EAVE - UNVENTEDSLOPEPER PLAN12TYPICAL ROOF:COMPOSITION ROOFING O/ROOFING UNDERLAYMENTO/ ROOF TRUSS AT 24" O.C.EXTERIOR SIDINGPER ELEVATIONS1D1ATTICINSUL.6262TOP FLASHING:OVER ROOFING AND OVERBOTTOM FLASHING,FACE-ATTACHBOTTOM FLASHING:INSTALL UNDER ROOFINGOVER ROOF UNDERLAYMENT51x3 TRIM OVER2x10 FASCIA2.573.5 2x3 SPACERFIRE-RETARDANT TREATEDPLYWOOD 4'-0' EITHER SIDE OF ?SOLID BLOCKINGNOTE: PROVIDEVENT BLOCKINGWHERE INDICATEDON ROOF PLANSPER ROOF PLANLOOSE FILLINSULATION22626262 1-1/2" = 1'-0"SECTIONGABLE RAKE DETAILCOMPOSITION ROOFINGRAKE FLASHING1x3 TRIM2x10 TRIMOUTRIGGERSIDING OVERSHEATHINGEND TRUSSROOF SHEATHING9D11D11-1/2" = 1'-0"SECTIONTYPICAL EAVECOMPOSITION SHINGLESOVER #15 FELT OVER ROOFSHEATHINGPROVIDE SOLIDBLOCKING9D1LOOSE FILLTRUSS ANDATTIC INSULATIONTYPICAL EXTERIOR WALLMETAL EAVEFLASHINGCUT TAILS BACK AND INSTALLSTRUCTURAL FASCIA PERFRAMING PLANSEE ROOFPLAN FORGUTTERLOCATIONPER PLANNO WALL OR ATTICINSULATION AND BAFFLEAT GARAGESEE ROOF PLANFOR SLOPE1D11262621-1/2" = 1'-0"SECTIONTYPICAL EAVE @ WINDOWCOMPOSITION SHINGLESOVER #15 FELT OVER ROOFSHEATHINGPROVIDE SOLIDBLOCKING9D1LOOSE FILLTRUSS ANDATTIC INSULATIONTYPICAL EXTERIOR WALLMETALEAVEFLASHINGCUT TAILS BACK ANDINSTALL STRUCTURALFASCIA PER FRAMINGPLANSEE ROOF PLANFOR GUTTERLOCATIONPER PLANNO WALL OR ATTICINSULATION AND BAFFLEAT GARAGESEE ROOF PLANFOR SLOPEBEAM PERFRAMING PLAN R-10 MIN.RIGID INSULATION626212RAISED HEELTRUSSES AT24" O.C.VARIES SEEROOF PLANSRAISED HEEL TRUSS SEE ROOF FRAMING PLAN1D19D1TYP. ROOF/CEILINGSIDING OVERSHEATHINGCOMPOSITION SHINGLESOVER ROOF SHEATHINGSOLID 2xBLOCK TRUSS1-1/2" = 1'-0"SECTIONOVERHANG W/ RAISED HEEL2X8 FASCIAMETALFLASHINGPROVIDE SOLIDBLOCKINGSEE ROOF PLANSFOR SLOPESEE ROOF PLANSFOR GUTTERLOCATIONS12SEE S SHEETS FORTRUSS BLOCKINGCONNECTION6262NO INSULATIONAT GARAGE2D1@ SIM.CONDITION2615131-1/2" = 1'-0"DECK/PORCH EVEVENT BLOCK W/ (3)2" V SCREENED VENTS.PROVIDE SOLIDBLOCKING WITHIN 5'-0"OF PROPERTY LINE(TYP)HDR PER STRUCT.FIBERCEMENTSOFFITBOARD9D1HARDI PANEL SMOOTH OVERPLYWOOD SHEATHINGBOX OUT TOMATCH WIDTH OFDECK COLUMN22DescriptionDateNo.Revisions4-6-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:D2Details DJV/AJC/HDMREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 CONC.SLABPAVING -SLOPE AWAYVARIES 8" MIN.6"MIN.SEE 15/S6.0 FOR STRUCTURAL INFO. 3/4" = 1'-0"SECTIONGARAGE APRON1" = 1'-0"PORCH EDGE DETAILHAND SACKWALL FACE6"312"8"SEE 4/A9FOR WOODCOLUMNHEIGHT INDICATED12BD1FINISH FLOOR8149121" = 1'-0"SECTIONCRAWLSPACE/UNDER SLAB DRAINAGECONCRETE SLABAT GARAGES.FREE-DRAININGGRAVEL4" RIGID DRAINAGEPIPE. SLOPE AT LEAST1% TO OUTFALL.LOCATE DEEP ENOUGHTO BE INSTALLEDBENEATH FOOTINGS.VAPOR BARRIERFOOTING171-1/2" = 1'-0"SECTIONSTAIR AT WALKWAY EDGE11"TYP.312" CONCRETE SLABCONCRETE STAIRSEE FDN. PLANSEXPANSION JOINTAT CONNECTIONWALKWAY1"12BD1SLOPE1-1/2" = 1'-0"SECTIONSTAIR AT PORCH EDGE3"1"7 34" MAX. TYP.11"TYP.EXPANSION JOINTAT CONNECTIONDROP APRON WHERE STAIR CONNECTS1'-0"TYPICAL APRON (EACH SIDE OF STAIR)CONCRETE STAIRSEE FDN. PLANS12BD1F.O. FDN.DIM. PT.PORCH1-1/2" = 1'-0"PLANTYP. BASEMENT WALL12" G.W.B. OVER 2x6 STUDS AT 16"O.C. (U.N.O. ON STRUCT.)NO SPRAY-ONOR SHEET-TYPEVAPOR BARRIERAT INTERIOR SIDE.PAINT WITH LATEXPAINT ONLY.CONC. RETAINING WALL(SEE STRUCT. FOR SIZE & REINF.)DRAINAGE COMPOSITE WITH INTEGRAL FILTER FABRIC OVERPROTECTION BOARD OVER WATERPROOF MEMBRANE OVERREINFORCED CONCRETE RETAINING WALL8"6"12" AIR GAP.CONCRETE WALL SHALL BEDRY TO THE TOUCH ANDCAVITY SHALL BE CLEAN OFDEBRIS BEFORE INSTALLINGINTERIOR SIDE6262EARTH SIDEOMIT INSUL. ATUNHEATED SPACE3218" MIN.SLOPE GRADEAWAY FROMBUILDINGSEE STRUCTURAL FORFOOTING SIZE AND REBAR4" FTG. DRAIN18" MIN.1D1P.T. PLATE12AD1EXTERIORINTERIORP.T. NAILER2"x2" MAX.R-10 RIGID INSULATIONDIM. PT.SECTION1 1/2" = 1'-0"TYP. EXTERIOR WALL FOOTING26SEE STRUCTURAL FORFOOTING SIZE AND REBARGARAGESLABGARAGE1-1/2" = 1'-0"SECTIONSLAB AT UNIT TO GARAGE STEPINTERIOR2D1VARIES, SEE FDN PLANS PER STRUCT.20BD2R-10 RIGID INSULATIONCONCRETESLAB12AD1P.T. NAILER2"x2" MAX.62DIM. PT.SLAB-ON-GRADESEE STRUC.FOR REINF.1-1/2" = 1'-0"SECTIONTHRESHOLD AT GARAGE/PORCHDOOR THRESHOLD734" MAX. 4" AT PORCH PATIO 112" MAX.CONC. SLABSEE STRUCT. FOR FOOTINGSIZE AND REINFORCEMENT12AD112BD1R-10 RIGID INSULATIONP.T. NAILER2"x2" MAX.INTERIORGARAGE/PORCHADD STEPS ASNEEDED ATGARAGESLOPE8" MIN.SLOPE GRADEAWAY FROMBUILDINGSEE STRUCTURALFOR FOOTING SIZEAND REBAR4" FTG. DRAIN18" MIN.1D1VARIES P.T. PLATE12BD162EXTERIORGARAGEDIM. PT.FDN. WALL STEPSSEE FDN. PLAN1-1/2" = 1'-0"SECTIONTYP. EXTR. GARAGE WALL FTG.41-1/2" = 1'-0"SECTIONON-GRADE PATIO SLABFINISH FLOOR18" CLEARANCETO GRADETHICKEN SLAB TOA MINIMUM OF 2"BELOW GRADE312" CONCRETE SLAB6"SLOPE2'161" = 1'-0"SECTIONRETAINING WALL AT HEATED INTERIORSLOPE TOP OFFOOTING TO DRAINSEE S SHEETSFOR FOOTINGSIZE AND REBARWATERSTOP STRIPREQUIRED ATCOLD JOINT(2 PART POUR)DAMPPROOFING COATINGAPPLIED ON ACCEPTABLESURFACEWATERPROOF MEMBRANEWATERPROOFING TO FULLYCOVER FORM BRACKETS(POUNDED FLAT)LET CURE 1 DAYRAIN SCREEN PRODUCTOVER TOP OF FOOTING,RUN PAST COLD JOINT 18"12" AIR GAP8"CAPILLARY BREAKBELOW SLABMIN. R-5 RIGIDINSULATION WITHMIN. 25 PSI COMP.STRENGTHTHICKENEDSLAB EDGECONTINUOUS 6"PERFORATED DRAIN PIPE ASSPECIFIED BY SOILS REPORT.HEATED INTERIOR1-1/2" = 1'-0"SECTIONSTEPPED & FURRED OUT RETAINING WALLSLOPE GRADEAWAY FROMBUILDING12" AIR GAPSEE FOUNDATION PLANFOR LOCATION SPECIFICDIMENSIONS8"MIN.GWB5D11D1INTERIORFLOOR FRAMINGDIRECTION MAY VARYFIN. FLOOR626262626262DIM. POINTEXTERIORINTERIOR1" = 1'-0"SECTIONAT EXTERIOR GRADERETAINING WALL12" AIR GAP2x6 P.T. PLATE5D11D1INSULATE FLOOROVER GARAGESLOPE GRADEAWAY FROMBUILDING8"MIN.(NO WALLINSULATIONAT GARAGE)62626622INTERIORINTERIOREXTERIOR1-1/2" = 1'-0"SECTIONHIGH RETAINING WALL AT CONC. SLAB12" AIR GAPFRAMING PERSTRUCTURALFLOOR FRAMINGDIRECTION MAY VARY5D11D1GARAGE ORPATIO SLABINTERIOR62626262INTERIORSEE FOUNDATIONPLAN FOR SLABHEIGHTS12BD118201511105/6D18"SLOPE PATIO SLABAWAY FROM BLDG.12BD1PT LEDGER6262INTERIOR2D7FLOOR FRAMING(INSUL. OVERUNHEATED SPACE) PT PLATEFRONT DOORTHRESHOLD OVERSILL PAN ANDMETAL FLASHINGPER BE SHEETSSEALANTBELOW SHTG.623D712" AIR SPACE 1-1/2" = 1'-0"SECTIONHIGH RETAINING WALL AT THRESHOLD191" = 1'-0"SECTIONRETAINING WALL AT GARAGESLOPE TOP OFFOOTING TO DRAINSEE S SHEETSFOR FOOTINGSIZE AND REBARWATERSTOP STRIPREQUIRED ATCOLD JOINT(2 PART POUR)DAMPPROOFING COATINGAPPLIED ON ACCEPTABLESURFACEWATERPROOF MEMBRANEWATERPROOFING TO FULLYCOVER FORM BRACKETS(POUNDED FLAT)LET CURE 1 DAYRAIN SCREEN PRODUCTOVER TOP OF FOOTING,RUN PAST COLD JOINT 18"8"CAPILLARY BREAKBELOW SLABTHICKENEDSLAB EDGECONTINUOUS 6"PERFORATED DRAIN PIPE ASSPECIFIED BY SOILS REPORT.GARAGE7DescriptionDateNo.Revisions4-6-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:D3Details DJV/AJC/HDMREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 WINDOWJAMBSEALANT12" GWBWINDOWJAMBBACKER-ROD& SEALANT, TYP.BACKER-ROD& SEALANT, TYP.54x6 WOOD TRIMBACKER-ROD &SEALANT, TYP.C62626262JAMBA626242SILLHEADJAMBWINDOW DETAILS3" = 1'-0"2662INSUL.WINDOWTYPICAL EXTERIOR WALLDBDCAREPRESENTATIVE ELEVATIONINSUL.INSUL.54x3 WOODTRIM, TYP.54x3 WOOD TRIM54x3 WOODTRIMSEE FRAMINGPLANS FORHEADER SIZEWINDOWR-10 MIN. RIGIDINSULATION54x3 WOOD TRIMSIDINGSIDINGSEALANTBW.R.B. OVERPRE-FLASHINGSELF-ADHERINGFLASHINGMEMBRANESELF-ADHERINGFLASHINGMEMBRANEPRE-FLASHINGW.R.B.W.R.B. SHALL LAPOVER VERT. LEGOF FLASHINGPRE-FLASHINGWINDOWFLASHINGW.R.B.PRE-FLASHINGW.R.B. 1-1/2" = 1'-0"WRAPPED COLUMN BASE1" GAPPOST PER STRUCTURALTHICKEN SLAB TOA MINIMUM OF 2"BELOW GRADE312" CONCRETE SLAB6"2"SEE S SHEETS FORSTRUCTURAL INFORMATIONPOST PER STRUCTURALHARDI-PANEL OVER12" PLYWOODBASE SECTIONCOLUMNPLANSLOPEPER PLAN PER PLAN1" GAPPOST PER STRUCTURALTHICKEN SLAB TOA MINIMUM OF 2"BELOW GRADE312" CONCRETE SLAB6"2"POST PER STRUCTURALHARDI-PANEL OVER12" PLYWOODBASE SECTIONCOLUMNPLANSLOPEAB8"8"32323232424242424242424281263" = 1'-0"WINDOW DETAILS (WITHOUT TRIM)SEALANTSEE FRAMING PLANS FOR HEADER SIZEPROVIDE 2x8 BLOCKING(FOR DRAPPERY) EACHSIDE OF HEADER AT ALLLIVING UNIT BEDROOMWINDOWS (TYP.)W.R.B. OVERPRE-FLASHINGSELF-ADHERINGFLASHINGMEMBRANESEALANTSELF-ADHERINGFLASHINGMEMBRANE1D114" GAPBACKER ROD & SEALANTMIN. GAP SHOWN SEEMFR INSTALLATIONINSTRUCTIONSWINDOW14" GAP DO NOTCAULK GAPSIDING (SEEELEVATIONS),INSTALL PERMANUF.W.R.B.WINDOWL CHANNEL TRIMINSUL.INSUL.24INSUL.JAMBBHEADCSILLDBACKER ROD &SEALANTWINDOWSIDING (SEEELEVATIONS),INSTALL PERMANUF.W.R.B.PRE-FLASHINGJAMBAPRE-FLASHINGW.R.B.SEALANTSIDING (SEE ELEVATIONS),INSTALL PER MANUF.SEALANTWINDOWBACKER ROD& SEALANTCONT. METALFLASHING EXTEND1" BEYOND EACHSIDE OF WINDOWW.R.B. SHALL LAPOVER VERT. LEGOF FLASHINGPRE-FLASHINGL CHANNEL TRIMSEE BUILDER SPECFOR INTERIOR WINDOWWRAP FINISHESSEE BUILDER SPECFOR INTERIORWINDOW WRAPFINISHESSEE BUILDER SPECFOR INTERIOR WINDOWWRAP FINISHESBACDSIDING (SEE ELEVATIONS),INSTALL PER MANUF.L CHANNELTRIM262626262626244MIN. R-10 RIGIDINSULATION2626REPRESENTATIVE ELEVATIONSEE BUILDER SPECFOR INTERIORWINDOW WRAPFINISHES1D11D1SEE S SHEETS FORSTRUCTURAL INFORMATION312"MAX.RAIL SYSTEM VERTICAL RAILSAT 4" OC MAX.42" MIN.MANUFACTURED RAIL SYSTEMAND CONNECTION DESIGN BYOTHERS - DEFERRED SUBMITTAL.ENGINEER OF RECORD TOREVIEW RAIL CONNECTION FORRIM CONSTRUCTIONCOMPATIBILITY.WRAPPED COLUMN ORPOST BEYONDDECK/PORCH 1-1/2" = 1'-0" RAILING AT DECK/PORCH1-1/2" = 1'-0"DECK SECTION AND DETAILS @ COLUMNSPT POST PER STRUCTURALPOST BASE PER STRUCTURALACDECK POST SECTION1-1/2" = 1'-0"EDGE OF CONCRETEPT POST PER STRUCTURALHARDI PANEL SMOOTH OVER12" PLYWOOD. SHEATHINGAPOST AT CONCRETE1-1/2" = 1'-0"BPOST AT DECK1-1/2" = 1'-0"FB & POST CAP PERSTRUCT.METAL DRIP FLASHINGRIP TOP OFJOISTS 14":12"11D1VENTED FIBERCEMENT SOFFIT12" MIN.HARDI PANEL SMOOTH OVERPLYWOOD SHEATHINGHARDI PANEL SMOOTH OVERPLYWOOD SHEATHINGBSIDING (PER ELEVATIONS)OVER PLYWOOD SHEATHINGBEAM PER STRUCT.2x JOISTPT POST PER STRUCTURAL2x JOISTJOIST HANGERPER STRUCT.C3"3"FLASHING BOOT1-1/2" = 1'-0"CPOST CAPPER STRUCT.FLASHING BOOT ATCOLUMN TO DECKCONNECTION, SOLDER ALLCORNERS. INSTALL BEFOREWATERPROOFING.2424242424242424BUGSCREEN3" ∅ VENT3" ∅ VENT1-1/2" = 1'-0"SECTIONDECK EDGE @ FLUSH BEAMFB PER STRUCT.METAL DRIP FLASHINGRIP TOP OF JOISTS 14":12"11D1VENTED FIBERCEMENT SOFFITSPACER AS NEEDED TOFLUSH OUT SIDINGGUARD RAIL,SEE DETAIL 17/D4SIDING PER ELEV.1-1/2" = 1'-0"SECTIONDECK TO WALL FLASHING 2x LEDGERSEE STRUCT.SEE STRUC. FORCONNECTION DETAILS1D1INTERIOREXTERIOR626211D14" MAX WATERPROOF DECK COATING CONTINUE UP WALL BEHINDMTL FLASHINGRIP TOP OF JOISTS 14":12"VENTED FIBERCEMENT SOFFIT5D16D120181417131-1/2" = 1'-0"SECTIONDECK @ FLOOR CANTILEVER 2x LEDGERSEE STRUCT.SEE STRUC. FORCONNECTION DETAILS1D1INTERIOREXTERIOR626211D14" MAX WATERPROOF DECK COATING CONTINUE UP WALL BEHINDMTL FLASHINGRIP TOP OF JOISTS 14":12"VENTED FIBERCEMENT SOFFIT5D1PER PLANGARAGE6D1DescriptionDateNo.Revisions4-6-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:D4Details DJV/AJC/HDMREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 1-1/2" = 1'-0"PLANGARAGE DOORSIDING OVERSHEATHINGPLYWOOD FILLER62626262FOUNDATION OPENINGDOOR SIZEGARAGE DOOR1x8 TRIM2x TRIM PERELEVATION3" = 1'-0"SECTIONGARAGE TRIM DETAILFLASHING2x TRIMHEADER PERSTRUCTURAL12" GWB38" SHIMSIDINGTRIM PERELEVATIONS3" = 1'-0"SECTIONBELLY BANDBEVEL TOP ANDBOTTOM OF BELLYBAND 10 DEGREESSIDING OVER OSBSHEATHINGMETAL FLASHING2x TRIM PER ELEVAITONSP.T. FURR STRIPS 16" O.C.1-1/2" = 1'-0"SECTIONWINDOW SILL AT ROOF1" MIN.ROOF FRAMINGTYPICAL EXTERIORWALLMTL. FLASHINGCOMPOSITION SHINGLESOVER ROOF SHEATHINGWINDOWWOOD TRIM TYP. SIZENOTED ON EXTERIOR ELEVATIONS.6262251263" = 1'-0"PLANTYP. PANEL REVEAL DETAIL:VERTICAL REVEAL TRIMW.R.B.EXTERIOR WALLSHEATHINGNOTE: DOUBLE STUDS ARE NECESSARYTO ASSURE FASTENERS PENETRATEREVEAL TRIM AND ATTACH TO STUDVERTICAL REVEAL TRIMINSTALL PER MANUF.1D1FIBER CEMENT PANELINSTALL PER MANUF.3" = 1'-0"SECTIONTYP. PANEL REVEAL DETAIL:HORIZONTAL REVEAL TRIMFIBER CEMENT PANELINSTALL PER MANUF.W.R.B.EXTERIOR WALLSHEATHING12" SPACING HORIZ. TRIMINSTALL PER MANUF.1D1TYP. EXT. WALLFLASHING TAPE OVERHORIZ. TRIM,INSTALL PER MANUF.371-1/2" = 1'-0"SECTIONWALL-TO-ROOF 1D1ROOFING OVERROOF SHEATHINGEXTEROR WALLTRUSSINTERIOREXTERIORMIN. 2"METAL STEP-FLASHINGW.R.B. OVER FLASHINGSIDING OVER W.R.B. OVERPLYWOOD SHEATHING13DescriptionDateNo.Revisions4-6-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:D5Details DJV/AJC/HDMREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023 3/4" = 1'-0"SECTIONCRAWLSPACE FOOTING8" MIN. 18" MIN.7D1D11FLOOR FRAMINGPER PLANSSEE S SHEETS FORSTRUCTURAL INFORMATIONCRAWLSPACEEXTERIOR26262VAPOR BARRIER4" PERF.PIPE DRAIN112" RIVERROCK4" SOLID PVCPIPE DRAINELEVATION PERDRAINAGE &CIVIL SYSTEM3/4" = 1'-0"SECTIONCRAWLSPACE FOOTINGAT HIGH FOUNDATION WALLSEE S SHEETS FORSTRUCTURAL INFORMATIONNOTE: EXTEND FOOTING6" AT PONY WALLPONY WALL ATBEARING CONDITIONPROVIDE 12" AIR SPACEBETWEEN CONCRETEAND PONY WALLSEE DETAIL 4/D3FOR DOOR THRESHOLD1D17D16"CONCRETE SLABAT PORCH ANDPATIO, SEEFOUNDATION PLANFLOOR FRAMINGPER PLANS8" MIN. 18" MIN. 214"24242426262P.T. PLATEVAPOR BARRIER4" PERF.PIPE DRAIN112" RIVERROCK4" SOLID PVCPIPE DRAINELEVATION PERDRAINAGE &CIVIL SYSTEM1-1/2" = 1'-0"SECTIONTHRESHOLD DETAIL2x4 TRIM OVEROSB SHEATHINGFLASHING FROMUNDER THRESHOLDDOWN ACROSSSHEATHINGTHRESHOLD AT ENTRYDOORSEALANTBELOW SHTG.FLOORINSULATION5"624242PORCHCONCRETEFIN. FL.UNITEXTERIOR7D13/4" = 1'-0"SECTIONCRAWLSPACE FOOTING ATGARAGE SLAB/PATIO SLABVARIES 18" MIN.7D12D1FLOOR FRAMINGPER PLANSSEE S SHEETS FORSTRUCTURAL INFORMATIONINTERIORGARAGE/EXTERIOR1D162622VAPOR BARRIER1-1/2" = 1'-0"SECTIONCRAWL SPACE TO BSMT RETAINING WALLINTERIORINTERIOR12" AIR GAP1'-2"5D17D1SEE DETAIL 17/D3FOR RETAININGWALL PARTICULARS444222SEE FOUNDATION PLAN 6262CRAWLSPACENOTE: FLOORFRAMING PERPLANSVAPOR BARRIER, SEENOTES ON SHEET D1512361-1/2" = 1'-0"SECTIONCRAWL SPACE TO BSMT RETAINING WALLINTERIORGARAGE8"6D17D1222SEE FOUNDATION PLAN CRAWLSPACENOTE: FLOORFRAMING PERPLANSVAPOR BARRIER, SEENOTES ON SHEET D16668DescriptionDateNo.Revisions4-6-23CanopyRenton,WACenturyCommunities25 Central Way, Suite 210Kirkland, Washington 98033P: 425.454.7130 F: 425.658.1208Web: www.milbrandtarch.com©Milbrandt Architects, INC., P.S.All rights reservedCopyright2023Sheet No.:Drawn By:Initial Publish Date:Date Plotted:22-05Job No.:D6Details DJV/AJC/HDMREVISION Received: 07/05/2023 / lwalkerBUILDING DIVISIONPR19000387B23002951_V2APPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 08/24/2023