HomeMy WebLinkAboutPRE_StaffComments_230907_v1DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 |www.rentonwa.gov PREAPPLICATION MEETING FOR Lambro Short Plat 301 NW 7th St (APN 9564800012) PRE23-000264 September 7, 2023 Contact Information: Planner: Andrew Van Gordon, 425-430-7286, avangordon@rentonwa.gov Public Works Plan Reviewer: Huy Huynh, 425-430-7384, hhuynh@rentonwa.gov Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org Please retain this packet throughout the course of your project as a reference. Consider giving copies of it to any engineers, architects, and contractors who work on the project. You will need to submit a copy of this packet when you apply for land use and/or environmental permits. Pre-screening: When you have the project application ready for submittal, call and schedule an appointment with the project manager to have it pre-screened before making all of the required copies. The pre-application meeting is informal and non-binding. The comments provided on the proposal are based on the codes and policies in effect at the time of review. The applicant is cautioned that the development regulations are regularly amended and the proposal will be formally reviewed under the regulations in effect at the time of project submittal. The information contained in this summary is subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director, Development Services Director, Department of Community & Economic Development Administrator, Public Works Administrator and City Council). M E M O R A N D U M DATE: August 9, 2023 TO: Andrew Van Gordon, Senior Planner FROM: Corey Thomas, Lead Plans Review Inspector SUBJECT: Lambro Short Plat 1. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of on e fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. The existing water main is a dead end 8 inch main with limited fire flow capability and thus any homes over the 3,600 square feet limit would be required to be equipped with an approved fire sprinkler system. It appears that there is one existing fire hydrant that will meet the minimum requirements. 2. The fire impact fees are currently applicable at the rate of $829.77 per single family unit. This fee is paid at building permit issuance. No charges apply to the existing homes that are to remain or if they are replaced with new homes. 3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150 feet of all points on the buildings. The maximum grade is 15 percent. Dead end roadways that exceed 150 feet require an approved fire apparatus turnaround, none exists now. Dead end roadways over 300 feet long require a full 90-foot diameter cul-de-sac. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: September 5, 2023 TO: Andrew Van Gordon, Planner FROM: Huy Huynh, Civil Engineer SUBJECT: Lambro Short Plat 301 NW 7th Street PRE23-00264 NOTE: The applicant is cautioned that information contained in this summary is preliminary and non- binding and may be subject to modification and/or concurrence by official City decision-makers. Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. I have completed a preliminary review for the above-referenced proposal located at parcel(s) 9564800012. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. WATER 1. The project is within the City of Renton’s water service area in the West Hill 495 Pressure Zone. 2. The static water pressure is approximately 160 psi at ground elevation of 130 feet. A pressure reducing valve shall be required for water pressure exceeding 80psi 3. There is an existing ¾” water service and meter. 4. There is an existing 8-inch water main located on NW 7th St that can deliver a maximum flow capacity of 1,232 GPM (see water plan No. W-072706 ). 5. There is 1 existing hydrants within 300 feet of the property that are connected to 8-inch water mains with a total maximum flow rate of 1,232 GPM. 6. Civil plans for the water main improvements might be required and must be prepared by a professional engineer registered in the State of Washington. Please refer to City of Renton General Design and Construction Standards for Water Main Extensions as shown in Appendix K of the City’s 2019 Water System Plan. Adequate horizontal and vertical separations between the new water main and other utilities (storm sewer pipes and vaults, sanitary sewer, power, gas, electrical) shall be provided for the operation and maintenance of the water main. Retaining walls, rockeries or similar structures cannot be installed over the water main unless the water main is installed inside a steel casing. 7. Based on the review of project information submitted for the pre-application meeting, Renton Regional Fire Authority has determined that the preliminary fire flow demand for single-family homes is 1,000 GPM minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 GPM fire flow would be required. 8. In the case that dwellings exceed 3,600 square feet, the dwellings will need to either have approved residential fire sprinklers or will need to improve an existing water main to provide a minimum fire flow of 1,500 GPM. 9. Installation of a separate water service (minimum 1-inch) and meter for each lot is required. The sizing of the meter shall be in accordance with the most recent edition of the Uniform Plumbing Code. Installation of the service and water meter shall be done by City forces, a separate water permit is required. 10. Installation of a landscape irrigation meter with a backflow prevention assembly (DCVA) is required if applicable. 11. The existing ¾” service and meter shall be cut and cap at the main by city forces. Separate water permit is required. Existing water meter can be used for irrigation purposes. 12. A conceptual utility plan will be required as part of the land use application for the subject development. 13. The development is subject to applicable water system development charges (SDC’s) and meter installation fees based on the number and size of the meters for domestic uses and for fire sprinkler use. The development is also subject to fees for water connections, cut and caps, and purity tests. Current fees can be found in the 2023 Development Fees Document on the City’s website. Fees will be charged based on the rate at the time of construction permit issuance. • The SDC fee for water for SFR is based on the size of the new domestic water to serve the project. The current water fee is $4,850.00 per 1-inch meter. • Water service installation charges for each SFR domestic water service is applicable. Water Service installation is $2,875.00 per 1-inch service line, • Drop-in meter fee for SFR is $400 per ¾-inch meter and $460.00 per 1-inch meter. • A credit will be applied if the existing service is abandoned. • The full fee schedule can be found at: https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof Renton SEWER 1. The project is within the City of Renton’s sanitary sewer service area. 2. There is an 8-inch gravity wastewater main located in NW 7th St (see record drawing S-007007). 3. There is an existing 4-inch sewer stub serving the property. 4. The existing 4-inch stub does not meet city’s standard. Existing stub shall be replaced with 6-inch PVC sewer stub. 5. Individual sewer stubs from a sewer main and individual side sewers are required for each lot. All new sewer stubs shall conform to the standards in RMC 4-6-040 and City of Renton Standard Details. 6. A conceptual utility plan will be required as part of the land use application for the subject development. 7. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer is based on the size of the new domestic water to serve the project. Current fees can be found in the 2023 Development Fees Document on the City’s website. Fees will be charged based on the rate at the time of construction permit issuance. • The current sewer SDC fee is $3,650.00 per 1-inch meter for each new SFR. • Final determination of applicable fees will be made after the water meter size has been determined. • The full fee schedule can be found at: https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof Renton SURFACE WATER 1. The site currently contains one single family residence and there is no on-site stormwater conveyance system. 2. Drainage plans and a drainage report complying with the adopted 2022 Renton Surface Water Design Manual will be required. Refer to Figure 1.1.2.A – Flow Chart in the 2022 City of Renton Surface Water Manual (2022 RSWDM) to determine what type of drainage review is required for this site. A drainage study complying with the 2022 RSWDM may be required. Based on the City’s flow control map, the site falls within the City’s Flow Control Duration Standard area (Matching Existing Conditions). The site falls within the West Lake Washington Basin and West Hill sub-basin. 3. Erosion control measures to meet the City requirements shall be provided. 4. The current City of Renton Surface Water Standard Plans that shall be used in all drainage submittals. The current City of Renton Standard details are available online at the City of Renton website: https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton. 5. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will be required to provide basic water quality treatment. Any proposed detention and/or water quality vault shall be designed in accordance with the RSWDM that is current at the time of civil construction permit application. Separate structural plans will be required to be submitted for review and approval under a separate building permit for the detention and/or water quality vault. 6. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated as described in Section C.1.3 of the 2022 RSWDM. A preliminary drainage plan, including the application of on-site BMPs, shall be included with the land use application, as applicable to the project. The final drainage plan and drainage report must be submitted with the utility construction permit application. 7. A geotechnical soils report for the site is required per the 2022 Renton Surface Water Design Manual Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be included in the report. The report should also include information concerning the soils, geology, drainage patterns and vegetation present shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage, or excess surface water runoff. 8. The development falls within the R-8 zone which has a maximum impervious surface area of 65% per lot. 9. The development is subject to a surface water system development charge (SDC) fee. Fees will be charged based on the rate at the time of construction permit issuance. a) The current SDC fee for new SFR is $2,300.00. b) The full schedule can be found at: https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067870&dbid=1&repo=Cityof Renton. TRANSPORTATION 1. In accordance with RMC 4-6-060, if the site improvements and/or proposed building additions exceed an overall valuation of $175,000, the project site(s) shall be required to meet the City’s Complete Streets Standards. a. The proposed project fronts NE 7th St West along the north property line. Northwest 7th St is within the King County Right-of-Way. Frontage improvements along the property frontage shall be in accordance with the King County design and construction standards. 2. Refer to City code 4-4-080 regarding driveway regulations. a. A minimum separation of 5 feet is required between driveway and the property line. b. Maximum driveway slopes shall not exceed 15%. Driveways exceeding 8% shall provide slotted drains. c. The maximum width of single loaded garage driveway shall not exceed nine feet (9') and double-loaded garage driveway shall not exceed sixteen feet (16'). 3. Street lighting is not required for a project that consists of 4 or less residential units. See RMC 4- 6-060 for street lighting requirements. 4. Paving and trench restoration within the City of Renton right of way shall comply with the City’s Restoration and Overlay requirements. 5. The development is subject to transportation impact fees. Fees will be charged based on the rate at the time of building permit issuance. a. The 2023 transportation impact fee is $12,208.54 per new single family home. b. The full fee schedule can be found at: https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof Renton GENERAL COMMENTS 1. Adequate separation between utilities as well as other features shall be provided in accordance with code requirements: a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical. b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 2. All civil construction permits for utility and street improvements will require separate plan submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-to-date plan submittal requirements: http://rentonwa.gov/business/default.aspx?id=42473 3. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan shall be on separate sheets. 4. Additional Building Permit Applications will be required for the following: a. Any retaining walls that exceed 4 feet in height, as defined by RMC 4-4-040. b. Detention vaults for storm water flow control. c. Demo of any existing structures on the project site(s). 5. Fees quoted in this document reflect the fees applicable in the year 2023 only and will be assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current fee schedule. 6. A demo permit is required for the demolition of the existing building. The demo permit shall be acquired through the building department. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: September 7, 2023 TO: Pre-Application File No. 23-000264 FROM: Andrew Van Gordon, Associate Planner SUBJECT: Lambro Short Plat – 301 NW 7th St (Parcel number 9564800012) General: We have completed a preliminary review of the pre-application for the above- referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision- makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public Works Administrator, Planning Director, and City Council). Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal Code. The Development Regulations are available online at https://www.codepublishing.com/WA/Renton/. Project Proposal: The applicant proposes to subdivide 301 NW 7th St (APN 9564800012) into two (2) residential lots for the benefit of detached dwellings. The property has street frontage along NW 7th St to the north. The lot is located within the Residential – 8 (R-8) zone. Per COR Maps, the property is approximately 11,068 square feet (0.25 acre). Access is proposed via NW 7th St. Current Use: The project area is currently developed with a detached dwelling with access from NW 7th St. The existing dwelling is proposed to be retained. Per COR Maps a high erosion hazard area, sensitive slopes and protected slopes are present on the site. Zoning/Land Use: The subject property is located within the Residential-8 (R-8) zoning classification. The Residential Medium Density Land Use designation is intended to implement the R-8 zone. The R-8 zone is established for single family dwellings. Development in the R-8 Zone is intended to create opportunities for new single family residential neighborhoods and to facilitate high-quality infill development that promotes reinvestment in existing single-family neighborhoods. It is intended to accommodate uses that are compatible with and support a high- quality residential environment and add to a sense of community. Detached dwellings are permitted within the R-8 zone. Density: The area of public rights-of-way, legally recorded private access easements and critical areas (i.e. very high landslide hazard areas, protected slopes (except evaluate on a case-by-case basis those protected slopes created by previous development, wetlands, Class 1 to 4 st reams and lakes or floodways) would be deducted from the gross site area to determine the “net” site area prior to calculating density. In order to calculate the proposed density of the project, any Lambro Short Plat Page 2 of 7 September 7, 2023 area of public road, private driveway/easement, and/or critical area dedication must be known. All fractions which result from net density calculations shall be truncated at two (2) numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations for minimum or maximum density that result in a fraction that is 0.50 or greater shall be rounded up to the nearest whole number. Those density calculations resulting in a fraction that is less than 0.50 shall be rounded down to the nearest whole number. The R-8 zone has a minimum density of four (4) dwelling units per acre with a maximum of eight (8) dwelling units per acre. It is unclear what the gross density is. The provided documents do not identify the existing lot layout. The project information on the provided site plan identifies that 217 NW 7th St (APN 42202401155) is included as part of the project, however, the project narrative identifies 301 NW 7th St (APN 956480012) as the lone project site. Further, the project narrative identifies the project area as 11,400 square feet, but COR Maps identifies 301 NW 7th St as 11,068 square feet; the combined square footage of 301 and 217 NW 7th St would be 17,898 square feet. If a portion of 217 NW 7th St is included as part of the subdivision, then the entirety of the lot needs to be included as part of the subdivision. Based on the materials provided, it is not clear if it is included in the subdivision. The applicant would be required to demonstrate compliance with the net density requirements of the zone at the time of formal application. A density worksheet deducting street improvements identified in the preapplication meeting and this memo would be required with the land use application. Development Standards: The project would be subject to RMC 4-2-110A, Development Standards for Residential Zoning Designations effective at the time of complete application (noted as “R-8 standards” herein). Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-8 zone is 5,000 square feet for parcels being subdivided. For short plats of parcels smaller than one (1) acre, one (1) parcel may be allowed to be smaller than the required minimum lot size. If all other parcels meet the required minimum lot size standard of the zone, one parcel may be allowed to be 4,500 square feet in size in the R-8 zone. Minimum lot width is 50 feet (50’); minimum lot depth is 80 feet (80’). In order to ensure compliance with Tier 1 requirements for Tree Preservation Priority, pursuant to RMC 4-4-130H2a, lot size and lot dimensions of the zone may be decreased by a maximum of 10 percent (10%), provided the applicant can demonstrate to the Administrator’s satisfaction that the reduction is necessary to ensure the preservation of all significant trees, as defined in RMC 4-11-200, required for retention within dedicated tract(s), pursuant to RMC 4-4- 130H1a, Minimum Tree Retention Requirements. It is not clear if the proposed lots are meeting standards. Protected slopes and their buffers are required to be placed in a tract and cannot be incorporated into lots. The slope critical areas and their buffers are not shown on the drawing. Compliance with minimum lot size, width and depth standards would be verified at the time of land use application. Building Standards – The R-8 standards allow a maximum building coverage of 50 percent (50%) of the lot area. The maximum impervious coverage in the R-8 zone is 65 percent (65%). The maximum wall plate height is restricted to 24 feet (24’), and the buildings shall be not more than two (2) stories. Roofs with a pitch equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate height; common rooftop features, such as chimneys, may project an additional four vertical feet (4’) from the roof surface. Non-exempt vertical Lambro Short Plat Page 3 of 7 September 7, 2023 projections (e.g., decks, railings, etc.) shall not extend above the maximum wall plate height unless the projection is stepped back one-and-a-half horizontal feet (1.5’) from each façade for each one vertical foot (1’) above the maximum wall plate height. The maximum wall plate height for detached accessory structures is 12 feet (12’) and the total floor area must be less than that of the primary structure. Accessory structures are also included in building lot coverage calculations. New development would need to comply with the maximum building coverage, impervious surface requirements, and building height regulations of the zone at the time of building permit review. Existing development proposed for retention would also be required to comply with building and coverage limitations and would be reviewed for compliance at the time of land use application. Setbacks – Setbacks are the minimum required distance between the building footprint and the property line. The required setbacks for the R-8 zone are: Front yard: 20 feet (20’) except when all vehicle access is taken from an alley, then 15 feet (15’); Secondary front yard (applies to corner lots): 15 feet (15’); Rear yard: 25 feet (25’); Side yard: five feet (5’) Within subdivisions, the minimum front yard and secondary front yard setback may be reduced to no less than twenty feet (20') provided the applicant can demonstrate to the Administrator’s satisfaction that the setback reduction is necessary to preserve and maintain a landmark tree within a tree protection tract, as each term is defined in RMC 4-11-200, Definitions T. An arborist report, pursuant to RMC 4-8- 120D.1, shall be prepared and provided to the City for review and concurrence, demonstrating that the setback reduction and project proposal serve to preserve the critical root zone of the tree within a tree protection tract. Compliance with required setbacks for new development would be verified at the time of building permit application. Existing development proposed for retention would be reviewed for compliance at the time of land use application. Residential Design and Open Space Standards Future single-family building permits would be subject to the RMC 4-2-115, Residential Design and Open Space Standards. Requirements related to garages, entries, modulation, windows/doors, scale, bulk, and character, roof forms, eaves, architectural detailing, and materials/color should be reviewed in their entity prior to submitting permit applications. Compliance with lot configuration requirements would be verified at the time of land use application. Compliance with building design requirements would be verified at the time of building permit review. Access/Parking: Access to the lots are proposed via NW 7th St. Each lot is required to accommodate off street parking for a minimum of two (2) vehicles. The maximum width of single loaded garage driveways shall not exceed nine feet (9’) and double loaded garage driveways shall not exceed 16 feet. Maximum driveway slopes shall not exceed 15 percent; provided, that driveways exceeding eight percent (8%) shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage/residence or crossing any public sidewalk. Driveways shall not be closer than five feet (5’) to any property line except as allowed per RMC 4-4-080I.9, Joint Use Driveways. Access designs were not included. A joint-use driveway would be preferred. Compliance with access and driveway requirements would be verified at the time of land use application. Lambro Short Plat Page 4 of 7 September 7, 2023 Landscaping: With the exception of critical areas, all portions of the development area not covered by structures, required parking, access, circulation or service areas, must be landscaped with native, drought-resistant vegetative cover. The minimum on-site landscape width required along street frontages is 10 feet and shall contain trees, shrubs, and landscaping. Street trees in the ROW planter will also be required. Landscaping may include hardscape such as decorative paving, rock outcroppings, fountains, plant containers, etc. Minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4-6-060, Street Standards. Street trees and, at a minimum, groundcover are to be located in this area when present. Street trees shall be planted in the center of the planting strip between the curb and the sidewalk at the following intervals; provided, that, where right-of-way is constrained, irregular intervals and slight increases or decreases may be permitted or required. Additionally, trees shall be planted in locations that meet required spacing distances from facilities located in the right-of-way including, but not limited to, underground utilities, streetlights, utility poles, traffic signs, fire hydrants, and driveways; such spacing standards are identified in the City’s Approved Tree List. Generally, the following spacing is required: i. Small- sized maturing trees: thirty feet (30') on center; ii. Medium-sized maturing trees: forty feet (40') on center; and iii. Large-sized maturing trees: fifty feet (50') on center. A conceptual landscape plan shall be provided with the land use applica tion as prepared by a licensed Landscape Architect, a certified nurseryman or other certified professional. Please be aware that frontage improvements will be required. Storm drainage facilities are required to comply with the minimum 15-foot perimeter landscaping strip on the outside of the fence unless otherwise determined through the site plan review or subdivision review process. Please refer to landscape regulations RMC 4-4-070 for further general and specific landscape requirements. Significant Tree Retention: When significant trees (greater than 6-inch caliper or 8-caliper inches for alders and cottonwoods) are proposed to be removed, a tree inventory and a tree retention plan along with an arborist report, tree retention plan and tree retention worksheet shall be provided with the formal land use application as defined in RMC 4-8-120. The tree retention plan must show preservation of at least 30% of significant trees. Please refer to RMC 4-4-130, Tree Retention and Land Clearing Regulations for further general and specific tree retention and land clearing requirements. In addition to retaining a minimum of 30% of existing significant trees, each new lot would be required to provide a minimum tree density of 30 tree credits per net acre. Tree credits encourage retention of existing significant trees with larger trees being worth more tree credits. TREE SIZE TREE CREDITS New small species tree 0.25 New medium species tree 1 New large species tree 2 Preserved tree 6 – 9 caliper inches 4 Lambro Short Plat Page 5 of 7 September 7, 2023 TREE SIZE TREE CREDITS Preserved tree 10 – 12 caliper inches 5 Preserved tree 12 – 15 caliper inches 6 Preserved tree 16 – 18 caliper inches 7 Preserved tree 19 – 21 caliper inches 8 Preserved tree 22 – 24 caliper inches 9 Preserved tree 25 – 28 caliper inches 10 Preserved tree 29 – 32 caliper inches 11 Preserved tree 33 – 36 caliper inches 12 Preserved tree 37 caliper inches and greater 13 Protected trees within a subdivision shall be retained in the order of priority listed in RMC 4 -4- 130H.2. Protection of trees or groves by placement within a dedicated tract (Tier 1) is the highest priority. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas and their associated buffers; significant trees over sixty feet (60') in height or greater than eighteen inches (18") caliper; and trees that shelter interior trees or trees on abutting properties from strong winds, which could otherwise allow such sheltered trees to be blown down if removed. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non-native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. The Administrator may require independent review of any land use application that involves tree removal and land clearing at the City's discretion. The Administrator may authorize the planting of replacement trees on the site if it can be demonstrated to the Administrator's satisfaction that replacement requirements in RMC 4-4- 130H.1.e can be met. Tree retention standards shall be applied to the developable area, as defined in RMC 4-11-040, Definitions D, of a property. A formal tree retention plan and tree retention worksheet prepared by an arborist or landscape architect would be reviewed at the time of the land use application. Lambro Short Plat Page 6 of 7 September 7, 2023 Fences/Walls: If the applicant intends to install any fences or retaining walls as part of this project, the location must be designated on the landscape plan and grading plan with top of wall and bottom of wall elevations. A fence and/or wall detail should also be included on the plan. A retaining wall that is 4 feet or taller, as measured by the vertical distance from the bottom of the footing to the finish grade at the top of the wall requires a building permit. The maximum height of any fence or retaining wall is 72-inches subject to further height limitations in setbacks and clear vision areas noted in RMC 4-4-040D. A fence shall not be constructed on top of a retaining wall unless the total combined height of the retaining wall and the fence does not exceed the allowed height of a standalone fence. For more information about fences and retaining walls refer to RMC 4-4-040. Hillside Subdivisions: Because of their steeper slopes, the sites of hillside subdivisions ordinarily should have greater attention paid to the potential for drainage, erosion, and slope stability problems than other subdivisions. Information concerning the soils, geology, drainage patterns, and vegetation shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate that the development of the hillside subdivision will not result in soil erosion and sedimentation, landslide, slippage, excess surface water runoff, increased costs of building and maintaining roads and public facilities and increased need for emergency relief and rescue operations. Detailed plans for any proposed cut and fill operations shall be submitted. These plans shall include the angle of slope, contours, compaction, and retaining walls. Plans shall be consistent with requirements in RMC 4- 4-060, Grading, Excavation and Mining Regulations. Areas of the subdivision deemed to be critical areas due to designation as protected slopes shall be located within a tract or tracts. See RMC 4- 7-220, Hillside Subdivisions for full requirements. Critical Areas: Per COR Maps a high erosion hazard area, sensitive slopes (>25% & <= 40% slope) and protected slopes (>40% & <=90% slope) are present on the site. A geotechnical report would be required at the time of the land use application. Environmental Review: Short Plats are generally exempt from State Environmental Policy Act (SEPA) review. However, the proposal would require environmental review pursuant to RMC 4-9- 070, Environmental Review Procedures. The project site has protected slopes located on it per COR Maps; WAC 197-11-800(3) does not apply. An Environmental Checklist must be submitted with the proposal and the City’s Environmental Review Committee is required to issue a Threshold Determination prior to any issuance for permits on the site. Permit Requirements: The proposal would require administrative short plat approval and Environmental Review. The application would be reviewed within an estimated time frame of eight weeks. The 2023 fees would total $8,274.00 ($6,080.00 Preliminary Short Plat + $1,800.00 Environmental Review + $394.00 Technology Fee (5%) = $8,274.00). Each modification request is $290.00. A 5% technology fee added to the total cost of the reviews would also be assessed at the time of land use application. All fees are subject to change. Detailed information regarding the land use permit application submittal requirements can be found on the Short Plat Submittal Requirements checklist. Other informational applications and handouts can be found on the City’s Digital Records Library. The City requires electronic plan submittal for all applications. Please refer to the City’s Electronic File Standards. A Final Short Plat application, and its associated fee, will be required following construction of the subdivision’s infrastructure. Lambro Short Plat Page 7 of 7 September 7, 2023 Public Information Sign: Public Information Signs are required for all Type II Land Use Permits as classified by RMC 4-8-080, Permit Classification. Public Information Signs are intended to inform the public of potential land development, specific permits/actions being considered by the City, and to facilitate timely and effective public participation in the review process. The applicant must follow the specifications provided in the public information sign handout. The applicant is solely responsible for the construction, installation, maintenance, removal, and any costs associated with the sign. Fees: In addition to the applicable building and construction fees, impact fees would be required. The fee in effect at the time of residential building permit issuance will apply. For informational purposes, the 2023 impact fees are as follows: • A Transportation Impact Fee assessed at $12,208.54 per each new detached dwelling unit. • A Parks Impact Fee assessed at $3,276.44 per each new detached dwelling unit subdivision. • A Fire Impact Fee assessed at $829.77 per each new detached dwelling unit. • A Renton School District Impact Fee assessed at $2,911.00 (plus a 5% processing charge) per each new detached dwelling unit. A handout listing Renton’s development-related fees is available on the City of Renton website for your review. Next Steps: When the formal land use application materials are complete, the applicant shall have the application materials pre-screened prior to submitting the complete application package. Please contact Andrew Van Gordon, Associate Planner at avangordon@rentonwa.gov or (425) 430-7286 for an appointment. Expiration: Upon approval, the Short Plat is valid for five years with a possible one-year extension (RMC 4-7-070M). It is the responsibility of the owner to monitor the expiration date.