HomeMy WebLinkAboutR-421235N
T
It
It
A
W
W
n
0
Z
Q
>
ai
U
U
n
N
J
I
Ib
N
/
Iv
00
N
0
0
0
PRUNE DAMAGED TWIGS AFTER PLANTING
PLACE IN VERT. POSITION: DOUBLE LEADERS WILL BE REJECTED
NOTE:
KEEP ROOTBALL MOIST AND PROTECTED AT ALL TIMES.
HOLD CROWN OF ROOTBALL AT OR JUST ABOVE FINISH
GRADE.
PROTECT TRUNK AND LIMBS FROM INJURY.
BACKFILL TO BE SETTLED USING WATER ONLY - NO
MECHANICAL COMPACTION.
REMOVE ALL WRAP, TIES & CONTAINERS, REGARDLESS
OF MATERIAL.
(2) LODGEPOLE STAKES, PLUMB WITH ELASTIC CHAIN -LOCK
TYPE OR RUBBER GUYS TIED IN FIGURE EIGHT; REMOVE
AFTER ONE GROWING SEASON
PROTECTIVE WRAPPING DURING SHIPMENT TO SITE AND
INSTALLATION REMOVE AT COMPLETION OF PLANTING
LAWN PLANTING; PROVIDE 3' 0 "NO GRASS" TREE RING AND
2" DEEP MULCH LAYER IN WELL. HOLD BACK FROM
TRUNK 8" TO 10"
.e
FINISH GRADE
PREPARE PLANTING BED PER SPEC'S; AT MIN., LOSSEN
AND MIX SOIL TO 18" OR DEPTH OF ROOTBALL AND 2
TIMES BALL DIAMETER
REMOVE ALL WRAP, TIES, AND CONTAINERS
SCORE ROOTBALL AND WORK NURSERY SOIL
AWAY FROM PERIMETER ROOTS
SET BALL ON UNDISTURBED BASE OR COMPACTED
MOUND UNDER BALL
PENETRATION TO SUBBASE (+) 24"
DECIDUOUS TREE PLANTING/STAKING DETAIL
NOT TO SCALE
CORNER POST
CAP (TYP.)
TENSION BANDS
TENSION BAR
3-112" DIA. TERMINAL
POST (GALVANIZED
STEEL PIPE)
10'-0" MAX. 10'-0" MAX.
RAIL END
ASSEMBLY
TREE PRO.
FIN&
GRAC
NOTE:
FENCING TO I
RAILS AND LI
WITH # 9 GA.
AT 12".
BRACE ALL CORNERS &
TERMINAL POSTS WITH 1-314"
DIAMETER GALVANIZED
STEEL PIPE & APPROPRIATE
FASTENERS.
LANDSCAPE DETAILS
OF
BRENNON LANDING (VAUGHN TRUST PROPERTY)
A PORTION OF SECTION 05, TOWNSHIP 23 N., RANGE 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
III (2) LODGEPOLE STAKES; TIE AT APPROX. 1/3 TO
1 /2 HEIGHT OF TREE WITH FLEXIBLE RUBBER TIE
IN FIGURE EIGHT PATTERN. STAKES AND TREE TO
BE PLUMB
3" DEEP SAUCER FOR WATER
z MULCH LAYER
to REMOVE ALL TIES, WRAP & CONTAINERS.
FREE PERIMETER ROOTS FROM NURSERY
BALL
EXCAVATE TREE PIT AT A MIN. OF 2 TIMES
DIA. OF ROOTBALL AT BALL CENTER,
TAPERING PIT GRADE TO FINISH GRADE
PIT SPOILS, NURSERY BALL WASTE BACKFILL
SET BALL ON UNDISTURBED SUBGRADE, —
OR COMPACTED SOIL.
,r
z
NOTE:
LIGHT FERTILIZER OVER PLANTING BED AFTER BACKFILL
ONLY; NO FERTILIZER IN PLANTING PIT.
WORK PERIMETER ROOTS FREE OF NURSERY BALL.
BALL & PIT TO BE COURSELY SCARIFIED.
EVERGREEN TREE PLANTING/STAKING DETAIL
NOT TO SCALE
TREE PRESERVATION NOTES
PROTECTION MEASURES DURING CONSTRUCTION: Protection measures in this subsection shall
apply for all trees that are to be retained on site and off site. Off -site trees containing drip lines that
encroach onto the site under construction shall be considered protected trees unless it is determined
the abutting property owner is in compliance with subsection C of this Section, Allowed Tree Removal
Activities. All of the following tree protection measures shall apply:
a. Construction Storage Prohibited: The applicant may not fill, excavate, stack or store any
equipment, dispose of any materials, supplies or fluids, operate any equipment, install impervious
surfaces, or compact the earth in any way within the area defined by the drip line of any tree to be
retained.
b. Fenced Protection Area Required: Prior to development activities, the applicant shall erect and
maintain six-foot (6) high chain link temporary construction fencing around the drip lines of all retained
trees or at a distance surrounding the tree equal to one and one -quarter feet (1-1/4) for everyone inch
(1') of trunk caliper, whichever is greater, or along the perimeter of a tree protection tract. Placards
shall be placed on fencing every fifty feet (50) indicating the words, "NO TRESPASSING — Protected
Trees," or on each side of the fencing if less than fifty feet (50). Site access to individually protected
trees or groups of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides.
In addition, the applicant shall provide supervision whenever equipment or trucks are moving near
trees.
C. Protection from Grade Changes: If the grade level adjoining to a tree to be retained is to be
raised, the applicant shall construct a dry rock wall or rock well around the tree. The diameter of this
wall or well must be equal to the tree's drip line.
d. Impervious Surfaces Prohibited within the Drip Line: The applicant may not install impervious
surface material within the area defined by the drip line of any tree to be retained, unless otherwise
approved by the City. (Ord. 5958, 12-9-2019)
e. Restrictions on Grading within the Drip Lines of Retained Trees: The grade level around any
tree to be retained may not be lowered within the greater of the following areas: (i) the area defined by
the drip line of the tree, or (ii) an area around the tree equal to one and one-half feet (1-1/2) in
diameter for each one inch (1') of tree caliper. A larger tree protection zone based on tree size,
species, soil, or other conditions may be required. (Ord. 5676, 12-3-2012)
f. Mulch Layer Required: A11 areas within the required fencing shall be covered completely and
evenly with a minimum of three inches (3) of bark mulch prior to installation of the protective fencing
Exceptions may be approved if the mulch will adversely affect protected ground cover plants. (Ord.
5676, 12-3-2012)
g. Monitoring Required during Construction: The applicant shall retain a certified arborist or licensed
landscape architect to ensure trees are protected from development activities and/or to prune branches
and roots, fertilize, and water as appropriate for any trees and ground cover that are to be retained.
h. Alternative Protection: Alternative safeguards may be used if determined to provide equal or
greater tree protection.
TREE PROTECTION DETAIL (CITY OF RENTON) OR APPROVED EQUAL FENCE CONSTRUCTION
NOT TO SCALE
DATUM
HORIZONTAL DATUM:
NAD '83/'91
BENCHMARK
FOUND PUNCHMARK IN 2" BRASS FOUND PUNCHMARK IN 2" BRASS DISC IN 2
DOME IN MONUMENT IN CASE WITH MONUMENT IN CASE WITH "X" AT
"X" 0.65' BELOW GRADE OBSERVED NE 16TH ST. 0.6' BELOW GRADE OBSERVED 1
VERTICAL DATUM: (NAD 83/11) (NAD 83/11) N0.
NAVD '88 N: 186463.16, E: 1304865.21 IN: 187664.64, E: 1304879.99
PER CITY COMMENTS
PER CITY COMMENTS
REVISION
SHRUB — PRUNE AS DIRECTED
BY LANDSCAPE ARCHITECT
HOLD MULCH FROM STEM
MULCH LAYER
4" SAUCER FOR WATERING
BACKFILL TO BE A MIX OF TOPSOIL,
FERTILIZER, AND PEAT MOSS
SCARIFY ROOTBALL ON CONTAINER
MATERIAL. REMOVE TOP 1 /3 OF
BURLAP ON B&B MATERIAL
DUST ROOT BALL WITH
ROOT GROWTH HORMONE
3x THE ROOTBALL
DIAMETER
NOTE:
APPLY ADDITIONAL 4 OZ. 8-32-1 6 FERTILIZER INTO TOP
2" OF PLANTING MIX.
PLANT SHRUB HIGH ENOUGH TO ALLOW POSITIVE DRAINAGE AWAY
FROM ROOTBALL. ROUGHEN ALL SURFACES OF PIT.
CUT AND REMOVE BURLAP FROM ROOT BALL
SHRUB PLANTING DETAIL
NOT TO SCALE
2" MULCH LAYER
(COMPACTED DEPTH)
FEATHER EXCESS
SOIL UNDER MULCH
1 " MULCH AT CROWN
1/2" ABOVE GRADE
1" ABOVE GRADE —
� PREPARED
PLANTING
BED
NOTE: �
REMOVE CONTAINER & WORK ROOTS ,
FREE OF SOIL.
BACKFILL TO BE SETTLED USING WATER ONLY
SEE PLANT LIST FOR PLANT SPACING
LESS THAN 1 GAL 1 GAL CONTAINER and LARGER
( PLANTED BEFORE MULCH) ( PLANTED BEFORE MULCH )
GROUNDCOVER PLANTING DETAIL
NOT TO SCALE
HOLD PLANTS FROM
EDGE OF PLANT
AS NOTED ON F
BED LINE EDGE
CURB/WALK -
PLANT MATERIAL SPACING DETAIL
NOT TO SCALE
SURVEYED:
DESIGNED: TCR
TCR
5/17/22
JMV
TCR
TCR
3/14/22
JMV
CHECKED:
JMV
BY
DATE
APPR
—ROvEJMv
SCALE:
N/A
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
FINISH GRADE AT —
4:1 SLOPE MAXIMUM
2% SLOPE MINIMUM
CURB PER CIVIL -
DRAWINGS (WALK
SIMILAR)
1" MAX.
MULCH LAYER
TOPSOIL AS SPECIFIED
FINISH GRADE AT
3:1 SLOPE MAXIMUM
10:1 SLOPE MINIMUM
PREPARED SUBGRADE
1" MAX.
CLEAR
i 4" d
SIDEWALK
LAWN CONDMON MULCH CONDITION (CURB SIMILAR)
PLANTER SECTION DETAIL
NOT TO SCALE
MULCH AT CURB DETAIL
NOT TO SCALE
SPACING AS CALLED OUT
ON PLAN/PLANT LIST
HOLD PLANTS FROM
EDGE OF PLANTER
AS NOTED ON PLANT LIST
NOTE:
THIS SPACING APPLIES TO
GROUNDCOVER AND FORMAL
SHRUB ROW PLACEMENT.
CALL BEFORE YOU DIG:
1-800-424-5555
CITY OF
PRI RENTON
Planning/Building/Public Works Dept.
MULCH LAYER
1 " MAX. TOP OF CURB
TO TOP OF MULCH
CURB
O
L
�
4-1
.�
W
C:
O
:30OONNN
N
Q
LO=
<\
>
j
L
L ^
4-7
N
�c/v�
W
O
V
�
r
N
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
VAUGHN PROPERTY
MAINVUE WA, LLC
121 3RD AVENUE
Kirkland. WA 98033
O
L0
T
O
O
T
N
T
M
H
H
H
H
W
OIT
M
�Ir-
N
z00
DATE: `
5/17/22
FIELDBOOK:
PAGE: D 0
DRAWING NO:
> w
SHEETL_,C:4 U
m