Loading...
HomeMy WebLinkAboutFabrication Shop Observation.City of Renton Gene Coulon Memorial Beach Park (T).C21005257.2023-02-08.M7221137.0014FABRICATION SHOP OBSERVATION REPORT Report Number:M7221137.0014 Service Date:02/08/23 20225 Cedar Valley Rd Ste 110 Report Date:02/13/23 Lynnwood, WA 98036-6365 425-742-9360 Client Project City of Renton WA City of Renton Gene Coulon Memorial Beach Park (T) Attn: Alan J. Wyatt 1201 Lake Washington Blvd N 1055 S Grady Way Renton, WA Renton, WA 98057-3232 Project Number: M7221137 Services: Special Inspections / Materials Testing Mayes/Terracon Rep.: Carl Tacker Reported To:Welder on site Contractor:American Construction Report Distribution: (1) City of Renton WA, Alan J. Wyatt (1) American Construction Co Inc, Aaron McMahill (1) American Construction Co Inc, John Blair (1) Mayes Testing Engineers, Inc, Jim Kay Reviewed By:____________________________________ (1) WSP USA Inc, Garth Nelson, P.E. Mark Gordon Department Manager III The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. DM010, 04-29-22 Rev.3 Page 1 of 1 Permit No.: C21005257 GENERAL INFORMATION Mack Cameron requested Mayes/Terracon be at the Rainier Welding shop located at 12441 Bartholomew for the following services: Steel Fabrication. The results of observations for today were reported to Welder on site. The construction documents referenced for this observation included: shop drawing 127. FABRICATION OBSERVATION Terracon provided shop fabrication observation at the request of the fabricator. Welding was performed prior to Mayes/Terracon’s arrival. Welder qualifications, filler metal and WPS could not be verified. Inspection Type Piece No.Member (heat #)Type of Weld Referenced Documents Applicable Code Status* Final Sub piece w1003 to w1011 to w1012 HP12X53 Beam (Unknown) V-Groove Shop drawing AWS D1.1 Complies * See below for details ADDITIONAL COMMENTS Performed ultrasonic testing of two beam splices per shop drawing 127. Backing was left in place on one flange at both splices (on inside of flange), drawing called for backing to be removed. COMPLIANCE STATEMENT Based on our observations and testing, the above noted items appear to be in general accordance with the project documents. Photo Log Report Number:M7221137.0014 Service Date:02/08/23 20225 Cedar Valley Rd Ste 110 Report Date:02/13/23 Lynnwood, WA 98036-6365 425-742-9360 City of Renton WAAttn: Alan J. Wyatt CT0001, 10-16-13, Rev.10 Page 1 of 1 (P1) Part tested (2 splices)