HomeMy WebLinkAboutLABORA~1CR0006, 05-13-22, Rev.8 Page 1 of 1 LABORATORY COMPACTION CHARACTERISTICS OF SOIL REPORT Report Number:M7221137.0022L Service Date: 06/12/23 20225 Cedar Valley Rd Ste 110 Report Date:06/13/23 Lynnwood, WA 98036-6365 425-742-9360 Client Project - M7221137 City of Renton WA City of Renton Gene Coulon Memorial Beach Park (T) Attn: Alan J. Wyatt 1201 Lake Washington Blvd N 1055 S Grady Way Renton, WA Renton, WA 98057-3232 Permit No.: C21005257 Material Information Sample Information Source of Material:Cadman Pit A511 Sample Date:06/07/23 Proposed Use:Structural Backfill Sampled By:Joseph Allen Sample Location:Site Stockpile Sample Description:Sandy gravel Laboratory Test Data Result Specifications Test Procedure:ASTM D1557 Liquid Limit: Test Method:Method D Plastic Limit: Sample Preparation:Dry Plasticity Index: Rammer Type:Mechanical In-Place Moisture (%): Maximum Dry Unit Weight (pcf):137.9 Optimum Water Content (%):8.8 AASHTO: Comments: Services:Special Inspection/Materials Testing Mayes/Terracon Rep.: Aaron Vanderpol Reported To: Contractor:American Construction Company Inc Report Distribution: (1) City of Renton WA, Alan J. Wyatt (1) American Construction Co Inc, Aaron McMahill (1) American Construction Co Inc, John Blair (1) Mayes Testing Engineers, Inc, Jim Kay Reviewed By:_______________________________ (1) WSP USA Inc, Garth Nelson, P.E.Barry Tuttle Project Field Manager Test Methods:ASTM D698, ASTM D4318, ASTM D4647, ASTM D4718 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above andshall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at thelocation(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Zero Air Voids Curve for Assumed Specific Gravity 2.70 1110987136 137 138 139 140 Water Content (%)Dry Unit Weight (pcf) CT0002, 5/28/23 Rev.9 Page 1 of 1 20225 Cedar Valley Rd Ste 110 Lynnwood, WA 98036-6365 425-742-9360 LABORATORY COMPACTION CHARACTERISTICS OF SOIL REPORT Report Number:M7221137.0022L Service Date: 06/12/23 Report Date:06/13/23 Task: Client Project City of Renton WA City of Renton Gene Coulon Memorial Beach Park (T) Attn: Alan J. Wyatt 1201 Lake Washington Blvd N 1055 S Grady Way Renton, WA Renton, WA 98057-3232 Project No.M7221137 Laboratory Reference #329 Sample Description:Silty Sand with Gravel Delivered By:JA Sample Location:Site Stockpile Date Sampled:6/7/2023 Date Delivered:6/7/2023 Supplier of Material:Cadman Pit A511 Sampled By:JA Proposed Use:Structural Backfill SP Test Results: Sieve Analysis (C136, C117) See attached analysis sheet PROCTOR TEST RESULTS Test Method: ASTM D-1557 Method C / C 127 / D 4718 (if needed) 137.9 pcf @ 8.8 % See attached analysis sheet Material sampled in accordance with appropriate standard. (ASTM D75, AASHTO T2) Services:Special Inspection/Materials Testing Tested By:Aaron Vanderpol Report Distribution (1) City of Renton WA, Alan J. Wyatt (1) American Construction Co Inc, Aaron McMahill (1) American Construction Co Inc, John Blair (1) Mayes Testing Engineers, Inc, Jim Kay Reviewed By:____________________________________ (1) WSP USA Inc, Garth Nelson, P.E.Barry Tuttle Project Field Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. 10029 S. Tacoma Way, Suite E-2 Ph 253-584-3720 Tacoma, WA 98499 Fax 253-584-3707 Client:City of Renton Report Date:6/13/2023 1055 South Grady Way Date Tested:6/12/2023 Project:City of Renton Gene Coulon Memorial Beach Park Project Number:M7221137 Test Method:ASTM D-1557 Method C / C 127 / D 4718 (if needed)Lab Number:329 Wet Preparation Mechanical X Dry Preparation X Hand Tamper Optimum Water Content %8.8 Max Dry Density lbs/ft3 137.9 Source of Sample:Cadman Pit A511 Description of Sample: Silty Sand with Gravel Sieve Size Percent Retained Bulk Specific Gravity of Oversize: 2.69 3/4 15% 2.70 3/8 31% 133.7 #4 43% Tested By:AVP As Received Moisture Information in this report applies only to the actual samples tested and shall not be reproduced except in full, without the approval of Mayes Testing Engineers, Inc. Zero Void line plotted at a Specific Gravity of: Maximum Density Uncorrected: Date Received: 6/7/2023 Moisture Density Relationship Test Test Results Sieve Analysis 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0Dry Density. lbs/ft3Water Content, % of dry Weight Maximum Dry Density 137.9 pcf Optimum Water Content8.8 % M7221137_06112023_PROCspreadsheet/6/13/2023 MTE Form # 149, Rev 2, 6/02