RECORD NUMBER
SUB-00412
Project Name: Central Maintenance Facility
Status: Approved as
Noted
Title: SH-Welding Procedures
and Qualifications
Creator: Joshua Alcala
Bid Item/
Reference ID:
01 29 00 BID ITEM 18 Creation Date: 6/5/2023
Drawing No: NA Due Date: 30 calendar days
Specification
Section:
05 50 00 Subcontractor/
Supplier
MD MARINE
ELECTRIC
Description:
SH-Welding Procedures and Qualifications
Submittal Attachments (Line Items)
No. Name Upload Date Doc Type Line Item Status
001 230605-SUB00411-055000-
SH.pdf
6/5/2023 Product
Data
Evergreen Erectors
Record - General Comments
# Items
Comment Date Created By Company
kingcty
Comment Text
CS-10-03-01-D3 050509 Page 1 of 1
SUBMITTAL REVIEW COMMENTS
Project:KC CMF
Project No.:122161 Regarding Submittal No.:1122161_SUB-00412_HDR_Review
Contractor shall review, approve and submit submittals in accordance with provisions of Contract documents. Purpose of Contractor's submittal is to demonstrate the
way by which Contractor proposes to conform to information given and design concept expressed in Contract Documents. By submitting submittals, the Contractor and
Subcontractor represents that they have reviewed for compliance with Contract Documents, approved the submittal, and has determined and verified materials, field measurements
and field construction criteria related thereto, or will do so, and has checked and coordinated information contained within such submittals with the requirements of the Work and
Contract Documents.
ACTION TAKEN: A – APPROVED D – NOT APPROVED
B – APPROVED AS NOTED E1 - NO ACTION REQUIRED - NOT REQUIRED BY CONTRACT DOCUMENTS
C - REVISE & RESUBMIT E2 - NO ACTION REQUIRED – PROJECT or CLOSEOUT INFORMATION
Submittal is “Project Information” which does not require Architect’s review or response, and a copy has been retained for HDR’s Project file:
During our handling of your submittal A/E noticed something(s) which we are bringing to your attention:
See Comments below. See comments on Submittal.
Calculations are not signed and sealed by a registered engineer licensed in the state of the Project.
Submittal is “Project Closeout Information” which does not require Architect’s review or response:
Forward to Owner & acquire their signature on transmittal indicating receipt & submit copy of transmittal to HDR for file.
HDR will forward to Owner for their acceptance.
During our handling of your submittal A/E noticed something(s) which we are bringing to your attention:
See Comments below. See comments on Submittal.
Submittal was not reviewed because it is not required by Contract Documents to be reviewed by Architect. Do not resubmit!
During our handling of your submittal A/E noticed something(s) which we are bringing to your attention:
See Comments below. See comments on Submittal.
Submittal was submitted incorrectly as indicated below: (Please review submittal requirements in Contract Documents and submit submittals in
accordance with requirements or they may be returned without review.)
Not submitted with correct Submittal Transmittal form. Utilize attached form.
Submittal is not a specified manufacture. (Substitution, if allowed, must be submitted in accordance with Contract Documents)
Not submitted with correct submittal number:
Wrong Section number Wrong sequence number Wrong re-submittal designation Correct number is __________
Submittal included items from more than one specification Section.
Specification Title / Manufacturer / or Description of Submitted Item is not complete.
Submittal is not reviewed, approved and signed by the Subcontractor, Contractor and/or Construction Manager.
Calculations are not signed and sealed by a registered engineer licensed in the state of the Project.
Submittal is incomplete / not adequate or not enough information provided for review.
Submittal is not legible. Provide High quality, high contrast print suitable for reproduction.
(Blue lines, sepias, faxes or third generation copies are not acceptable)
Comments:
NOTE: Contractor shall direct specific attention, in writing or on resubmitted submittal, to revisions other than those requested by Architect on previous
submittals. In absence of such written notice Architect's approval of a resubmission shall not apply to such revisions.
Architect's review is limited to provisions stipulated in Contract Documents and Architect's agreement with the Owner: Architect's review is for limited purpose of
checking for conformance with information given and design concept expressed in Contract Documents. Architect's review of submittals is not conducted for purpose of
determining accuracy and completeness of other details such as dimensions and quantities, or for substantiating instructions for installation or performance of equipment or
systems, all of which remain the responsibility of Contractor as required by Contract Documents. Architect's review of submittals shall not relieve Contractor's contractual
obligations. Architect's review shall not constitute approval of safety or health precautions or, of any construction means, methods, techniques, sequences or procedures.
Architect's review or approval of a specific item shall not indicate approval of an assembly of which item is a component. Deviation from the Contract Documents not clearly noted
or addressed by the Contractor, have not been reviewed and can only be authorized by a properly executed Change Order.
FROM:HDR Architecture
BY:Christopher Walling DATE:6/20/23
PROJECT NAME CENTRAL MAINTENANCE FACILITY
DATE 6/5/2023
Prime CONTRACTOR Bayley
CONTRACTOR Evergreen Erectors
SUBCONTRACTOR NA
SUPPLIER
DRAWING REFERENCE N/A
SPEC SECTION 05 50 00
SPEC SUB PART 1.02B.1
LOCATION SH
CATEGORY Info
TYPE Qualifications
SUBMITTAL TITLE SH-Welding Procedures and Qualifications
SUBMITTAL
Welding certs are not included in this submittal.
Project Name
REVIEWED
REVISE RESUBMIT
REJECTED
BY
SUBMITTAL#
DATE
SPEC
4
Maiya Loucks 6/5/2023
00412 05 50 00
CMF Renton Company Logo
This review is only for general conformance of the project and general
compliance. Corrections or comments made on these drawings during this
review do not relieve Contractor/Subcontractor from compliance with the
requirements of the plans and specifications. Contractor is responsible for all
dimensions and fabrication to be confirmed and correlated at the job site
NOT REVIEWED
PROVIDE SUBMITTAL WITH
WABO CERTS PER SEPCS
SECTION 01 45 00:1.05.L.2
& 05 15 00:1.06.B
PROVIDE SUBMITTAL TO
SPECIAL INSPECTOR FOR
FURTHER REVIEW.
NO EXCEPTIONS TAKENMAKE CORRECTIONS NOTEDREVISE & RESUBMITREJECTED
REVIEWED FOR DESIGN INTENT ONLY.DIMENSIONS AND QUANTITIES ARENOT GUARANTEED.SEE STRUCTURAL GENERAL NOTES ONCONTRACT DOCUMENTS.
REVIEWED FOR LOADS IMPOSED ONBASIC STRUCTURE ONLY. SEESTRUCTURAL GENERAL NOTES ONCONTRACT DOCUMENTS.
NOT REVIEWED
Casey MooreBY
DATE 06/15/2023
LUND OPSAHL, LLC
Seattle, Washington
esab.com
Coreshield 8
Coreshield 8 is a self-shielded flux cored wire designed to weld critical structural applications while maintaining excellent
arc characteristics and high welder appeal using DCEN polarity. Coreshield 8 is tested and certified to meet the new AWS
D designation requirements, making this self-shielded wire an excellent choice for demand critical welds when the AWS
D1.8 Seismic Supplement is utilized
Classifications:AWS A5.20:E71T-8 JD-H8, AWS A5.36:E71T8-A2-CS3-H8, ASME SFA 5.20, ASME SFA 5.36
Approvals:Seismic Certified “D” , ABS , BV , DB , LR , DNV-GL , CWB CSA W48 E491T-8-H8
Approvals are based on factory location. Please contact ESAB for more information.
Typical Tensile Properties
Condition Yield Strength Tensile Strength Elongation
As Welded 465 MPa (67 ksi)565 MPa (82 ksi)24 %
Typical Charpy V-Notch Properties
Condition Testing Temperature Impact Value
As Welded 4 °C (40 °F)85 J (65 ft-lb)
As Welded -29 °C (-20 °F)41 J (30 ft-lb)
Typical Weld Metal Analysis %
C Mn Si S P Al
0.19 0.44 0.15 0.003 0.010 0.51
Deposition Data
Diameter Amps Wire Feed Speed Deposition Rate Efficiency
1.6 mm (1/16 in.)155 A 381 cm/min (150 in./min)1.9 kg/h (4.16 lb/h)78.6 %
1.6 mm (1/16 in.)180 A 470 cm/min (185 in./min)2.3 kg/h (5.14 lb/h)79.6 %
1.6 mm (1/16 in.)205 A 610 cm/min (240 in./min)3.0 kg/h (6.60 lb/h)78.2 %
1.6 mm (1/16 in.)220 A 698 cm/min (275 in./min)3.4 kg/h (7.53 lb/h)78.9 %
1.8 mm (0.072 in.)200 A 406 cm/min (160 in./min)2.8 kg/h (6.13 lb/h)79.4 %
1.8 mm (0.072 in.)225 A 483 cm/min (190 in./min)3.3 kg/h (7.32 lb/h)80.3 %
2.0 mm (5/64 in.)150 A 229 cm/min (90 in./min)1.8 kg/h (3.96 lb/h)80.6 %
2.0 mm (5/64 in.)175 A 279 cm/min (110 in./min)2.2 kg/h (4.83 lb/h)80.9 %
2.0 mm (5/64 in.)200 A 343 cm/min (135 in./min)2.7 kg/h (5.93 lb/h)80.4 %
MILD STEEL WIRES
SELF-SHIELDED FLUX-CORED WIRES (FCAW)410964-en_US-FactSheet_Main-01.pdf 10/26/16