HomeMy WebLinkAboutD_Enclave_Short_Plat_FINALDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Project Location Map
D_Enclave_Short_Plat_FINAL (002)
A. ADMINISTRATIVE REPORT & DECISION
Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED
Report Date: October 2, 2023
Project File Number: PR23-000032
Project Name: Enclave Short Plat
Land Use File Number: LUA23-000036, SHPL-A, MOD, ECF
Project Manager: Jill Ding, Senior Planner
Owner/Applicant: Vijay Kakubal and Ramesh Vudathu, VK Ventures, LLC, 3712 77th Ave SE, Mercer
Island, WA 98040
Contact: Mazen Haidar, PE, Pacific Land Engineering, 13617 SE 18th St, Bellevue, WA 98005
Project Location: 980 Hoquiam Ave NE, Renton, WA 98059
Project Summary: The applicant is requesting Preliminary Short Plat approval and Environmental (SEPA)
Review for the subdivision of an existing 89,298 square foot (2.05 acres) lot into 4
lots for the future construction of single-family residences. An existing single-family
residence is proposed for removal. The project site is located within the Residential-
8 (R-8) dwelling units per acre zone. The proposed lots would range in area from
approximately 6,169 sq. ft. to 6,228 sq. ft. and would be accessed off NE 10th St via
residential driveways. A Category III wetland has been identified on the south portion
of the project site. Category III wetlands have a standard buffer width of 75 feet, the
applicant is requesting a buffer reduction to 56.25 feet. Frontage improvements are
proposed along the site's NE 10th St and Hoquiam Ave NE frontages. A Street
Standards Modification has been requested to retain the existing pavement width
along Hoquiam Ave NE.
Site Area: 89,298 sq. ft. (2.05 acres)
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 2 of 25
D_Enclave_Short_Plat_FINAL (002)
B. EXHIBITS:
Exhibits 1-6: ERC Report and Exhibits
Exhibit 7: Administrative Decision
Exhibit 8: SEPA Determination of Non-Significance
Exhibit 9: Landscape Plan
Exhibit 10: Arborist Report, prepared by Sound Tree Consulting, dated August 3, 2022
Exhibit 11: Street Standards Modification Request
Exhibit 12: Transportation Concurrency Memo
Exhibit 13: Geotechnical Report, dated July 17, 2020, prepared by Nelson Geotechnical Associates,
Inc.
Exhibit 14: Technical Information Report (TIR), prepared by Pacific Land Engineering. dated
September 1, 2023
C. GENERAL INFORMATION:
1. Owner(s) of Record: Vijay Kakubal and Ramesh Vudathu
VK Ventures, LLC
3712 77th Ave SE
Mercer Island, WA 98040
2. Zoning Classification: Residential-8 (R-8)
3. Comprehensive Plan Land Use Designation: Residential Medium Density (MD)
4. Existing Site Use: An existing single-family residence is proposed for
removal.
5. Critical Areas: Category III Wetland
6. Neighborhood Characteristics:
a. North: Single family residences, R-8 zone
b. East: Single family residences, R-8 zone
c. South: Single family residences, R-8 zone
d. West: Single family residences and Hazen High School, R-8 zone
7. Site Area: 89,298 sq. ft. (2.05 acres)
D. HISTORICAL/BACKGROUND:
Action Land Use File No. Ordinance No. Date
Comprehensive Plan N/A 5758 06/22/2015
Zoning N/A 5758 06/22/2015
Annexation N/A 4918 10/24/2001
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 3 of 25
D_Enclave_Short_Plat_FINAL (002)
E. PUBLIC SERVICES:
1. Existing Utilities
a. Water: Water service will be provided by King County Water District 90. The site is located outside
of a Wellhead Protection Area.
b. Sewer: Sewer service is provided by the City of Renton. There is an existing 8-inch sewer main in NE
10th Street. There is also an existing 8-inch sewer main located along the east side of the project site.
c. Surface/Storm Water: There are existing storm drainage facilities located within NE 10th Street and
Hoquiam Avenue NE.
2. Streets: The project site has frontage along NE 10th Street along the north property line and Hoquiam
Avenue NE along the west property line. NE 10th Street is classified as a Residential Access Street. Existing
right-of-way (ROW) width is approximately 51 feet. Hoquiam Avenue NE is classified as a Collector Arterial.
Existing ROW width is approximately 60 feet. NE 10th Street currently contains a meandering 5-foot wide
sidewalk. There are no existing frontage improvements along Hoquiam Avenue NE.
3. Fire Protection: Renton Regional Fire Authority (RRFA)
F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE:
1. Chapter 2 Land Use Districts
a. Section 4-2-020: Purpose and Intent of Zoning Districts
b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations
c. Section 4-2-110: Residential Development Standards
d. Section 4-2-115: Residential Design and Open Space Standards
2. Chapter 3 Environmental Regulations and Overlay Districts
a. Section 4-3-050: Critical Area Regulations
3. Chapter 4 City-Wide Property Development Standards
4. Chapter 6 Streets and Utility Standards
a. Section 4-6-060: Street Standards
5. Chapter 7 Subdivision Regulations
a. Section 4-7-070: Detailed Procedures for Short Subdivision
6. Chapter 9 Permits – Specific
a. Section 4-9-250: Variances, Waivers, Modifications, and Alternates
7. Chapter 11 Definitions
G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN:
1. Land Use Element
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 4 of 25
D_Enclave_Short_Plat_FINAL (002)
H. FINDINGS OF FACT (FOF):
1. The Planning Division of the City of Renton accepted the above master application for review on February
7, 2023 and determined the application complete on February 16, 2023. The project was placed on hold
on March 14, 2023 and was taken off hold on September 6, 2023. The project complies with the 120-day
review period.
2. The project site is located at 980 Hoquiam Ave NE, Renton, WA 98059.
3. The project site is currently developed with an existing single-family residence, proposed for removal.
4. Access to the site would be provided via individual residential driveways off NE 10th Street.
5. The property is located within the Residential Medium Density (MD) Comprehensive Plan land use
designation.
6. The site is located within the Residential-8 (R-8) zoning classification.
7. There are approximately six (6) trees located on-site (outside of any critical areas or buffers), of which the
applicant is proposing to retain a total of four trees.
8. The site is mapped with a Category III wetland.
9. Approximately 1,167 cubic yards of material would be cut on-site and approximately 873 cubic yards of
fill is proposed to be brought into the site.
10. The applicant is proposing to begin construction in summer of 2024.
11. Staff received one public comment email (Exhibit 5) and one agency email from the Duwamish Tribe
(Exhibit 4). To address public comments the following report contains analysis related to drainage and
critical areas.
12. Representatives from various city departments have reviewed the application materials to identify and
address issues raised by the proposed development. These comments are contained in the official file,
and the essence of the comments has been incorporated into the appropriate sections of this report and
the Departmental Recommendation at the end of this report.
13. Pursuant to the City of Renton's Environmental Ordinance and SEPA (RCW 43.21C, 1971 as amended), on
March 27, 2023 the Environmental Review Committee issued a Determination of Non-Significance (DNS)
for the Enclave Short Plat (Exhibit 7). A 14-day appeal period commenced on October 2, 2023 and ends
on October 16, 2023. No appeals of the threshold determination have been filed as of the date of this
report.
14. Comprehensive Plan Compliance: The site is designated Residential Medium Density (MD) on the City’s
Comprehensive Plan Map. The purpose of the MD designation is to allow a variety of single-family and
multi-family development types, with continuity created through the application of design guidelines, the
organization of roadways, sidewalks, public spaces, and the placement of community gathering places
and civic amenities. The proposal is compliant with the following Comprehensive Plan Goals and Policies
if all conditions of approval are met:
Compliance Comprehensive Plan Analysis
Policy L-3: Encourage infill development of single-family units as a means to meet
growth targets and provide new housing.
Goal L-I: Utilize multiple strategies to accommodate residential growth, including:
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 5 of 25
D_Enclave_Short_Plat_FINAL (002)
• Development of new single-family neighborhoods on large tracts of land outside
the City Center,
• Development of new multi-family and mixed-use in the City Center and in the
Residential High Density and Commercial Mixed Use designations, and
• Infill development on vacant and underutilized land in established neighborhoods
and multi-family areas.
Goal L-U: Preserve, protect, and enhance the quality and functions of the City’s
sensitive areas including: lakes, rivers, major and minor creeks, intermittent stream
courses and their floodplains, wetlands, ground water resources, wildlife habitats, and
areas of seismic and geological hazards.
Policy L-28: Minimize erosion and sedimentation in and near sensitive areas by
requiring appropriate construction techniques and resource practices, such as low
impact development.
Policy L-30: Maintain or increase the quantity and quality of wetlands. Development
activities shall not decrease the net acreage of existing wetlands.
Policy L-31: Protect buffers along wetlands and surface waters to facilitate infiltration
and maintain stable water temperatures, provide for biological diversity, reduce
amount and velocity of run-off, and provide for wildlife habitat.
Policy L-34: Ensure buildings, roads, and other features are located on less sensitive
portions of a site when sensitive areas are present.
Goal L-BB: Maintain a high quality of life as Renton grows by ensuring that new
development is designed to be functional and attractive.
Goal L-FF: Strengthen the visual identity of Renton and its Community Planning Areas
and neighborhoods through quality design and development.
Policy L-48: Address privacy and quality of life for existing residents by considering
scale and context in infill project design.
Policy L-55: Preserve natural landforms, vegetation, distinctive stands of trees, natural
slopes, and scenic areas that contribute to the City’s identity, preserve property values,
and visually define the community and neighborhoods.
15. Zoning Development Standard Compliance: The site is classified Residential-8 (R-8) on the City’s Zoning Map.
Development in the R-8 Zone is intended to create opportunities for new single-family residential
neighborhoods and to facilitate high-quality infill development that promotes reinvestment in existing single-
family neighborhoods. It is intended to accommodate uses that are compatible with and support a high-quality
residential environment and add to a sense of community. The proposal is compliant with the following
development standards, as outlined in RMC 4-2-110.A, if all conditions of approval are met:
Compliance R-8 Zone Develop Standards and Analysis
Density: The allowed density range in the R-8 zone is a minimum of 4.0 to a maximum
of 8.0 dwelling units per net acre. Net density is calculated after the deduction of
sensitive areas, areas intended for public right-of-way, and private access easements.
All fractions which result from net density calculations shall be truncated at two (2)
numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations for minimum or
maximum density which result in a fraction that is one-half (0.50) or greater shall be
rounded up to the nearest whole number. Those density calculations resulting in a
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 6 of 25
D_Enclave_Short_Plat_FINAL (002)
fraction that is less than one-half (0.50) shall be rounded down to the nearest whole
number.
Staff Comment: The project site has a gross site area of 89,218 square feet (2.05 acres).
After the deduction of 644 square feet for row dedication and 30,888 square feet of
wetland, the project site would have a net area of 57,686 square feet or 1.32 acres. The
proposal for 4 lots on the 1.32 net acre site would result in a net density of 3.03 dwelling
units per net acre, which is less than the minimum density of 4.0 dwelling units per net
acre required in the R-8 zone. In accordance with RMC 4-2-110E.1.b “In the event the
applicant can show that minimum density cannot be achieved due to lot configuration,
lack of access, environmental or physical constraints, minimum density requirements
may be waived.” The project site includes environmental constraints (i.e. category III
wetland) as well as restraints due to compliance with the City’s adopted Surface Water
Manual (see further discussion below under FOF 20) that preclude the development of
more than four lots on the project site. As the configuration of the development of the
project site is limited by environmental constraints, staff recommends the proposed
project be waived from the minimum density requirements of the R-8 zone
Compliant if
condition of
approval is met
Lot Dimensions: The minimum lot size permitted in the R-8 zone is 5,000 sq. ft. A
minimum lot width of 50 feet is required (60 feet for corner lots) and a minimum lot
depth of 80 feet is required.
The following table identifies the proposed approximate dimensions for Lots 1-5
Proposed Lot Lot Size (sq. ft.) Lot Width (ft.) Lot Depth (ft.)
Lot 1 (corner lot) 6,169 67.90 93
Lot 2 6,228.50 67 93
Lot 3 6,228.50 67 93
Lot 4 6,228.50 67 93
Drainage Tract B 9,207.34 N/A N/A
Critical
Area/Stormwater
Tract A 61,054 N/A N/A
Staff Comment: As demonstrated in the table above, all lots would comply with the
minimum lot size, width, and depth requirements of the R-8 zone. All proposed lots
would have front yard areas oriented to the north towards NE 10th Street. However, the
achieve the lot dimensions proposed, the applicant is requesting a reduction in the
width of the wetland buffer (see further Critical Areas discussion below under FOF 17).
The proposed lot depth could be reduced to the minimum depth of 80 feet, which would
allow for an additional 13 feet of wetland buffer area. If the lot depths were reduced to
the minimum required depth of 80 feet, the lots would have the following dimensions:
Proposed Lot Lot Size (sq. ft.) Lot Width (ft.) Lot Depth (ft.)
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 7 of 25
D_Enclave_Short_Plat_FINAL (002)
Lot 1 (corner lot) 5,306 67.90 80
Lot 2 5,360 67 80
Lot 3 5,360 67 80
Lot 4 5,360 67 80
As demonstrated in the table above, if the lot depth of the proposed lots were reduced
to the minimum required depth of 80 feet, all lots would still comply with the minimum
lot size, width, and depth requirements of the R-8 zone. Staff recommends, as a
condition of approval, that the lot depth of the proposed lots be reduced to the
minimum required depth of 80 feet and that the wetland buffer and Tract A boundary
be extended to the north an additional 13 feet.
To ensure maintenance of all common improvements within the proposed short plat,
staff recommends, as a condition of approval that all lots have a common undivided
interest in proposed Tracts A and B and that a maintenance agreement be established.
A draft maintenance agreement for all common improvements shall be submitted at
the time of Construction Permit Review for the review and approval of the Current
Planning Project Manager.
Compliant if
condition of
approval is
met
Setbacks: The required setbacks in the R-8 zone are as follows: front yard is 20 feet,
side yard is 5 feet, secondary front yard (applies to corner lots) is 15 feet, and the rear
yard is 20 feet.
Staff Comment: As shown on the preliminary short plat plan set (Exhibit 2), the proposed
lots would provide adequate area for compliance with the required setback areas.
Compliance with the setback requirements for the individual homes would be verified
at the time of building permit review. The existing home and detached accessory
structures would not comply with the required setback areas of the new lots. Staff
recommends, as a condition of approval, that the existing home and detached accessory
structured be removed prior to the recording of the short plat. A demolition permit shall
be obtained and all required inspections completed prior to the recording of the short
plat.
Compliance
not yet
demonstrated
Building Standards: The R-8 zone has a maximum building coverage of 50% and a
maximum impervious surface coverage of 65%. In the R-8 zone, a maximum building
height of 2 stories with a wall plate height of 24 feet is permitted. Roofs with a pitch
equal to or greater than 4:12 may project an additional six (6) vertical feet from the
maximum wall plate height. If the height of wall plates on a building are less than the
states maximum the roof may project higher to account for the difference, yet the
combined height of both features shall not exceed the combined maximums. Common
rooftop features, such as chimneys, may project an additional four (4) vertical feet from
the roof surface. Non-exempt vertical projections (e.g., roofs pitched less than 4:12,
decks, railings, etc.) may extend up to six (6) vertical feet above the maximum wall plate
height if the projection is stepped back one-and-a-half (1.5) horizontal feet from each
minimum building setback line for each one (1) vertical foot above the maximum wall
plate height.
Wall plates supporting a primary roof surface that has only one (1) sloping plane (e.g.,
shed roof) may exceed the stated maximum if the average of wall plate heights is equal
or less than the maximum wall plate height allowed.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 8 of 25
D_Enclave_Short_Plat_FINAL (002)
Staff Comment: Building height, building coverage, and impervious surface coverage
for the new single-family residences would be verified at the time of building permit
review.
Compliant if condition of
approval is
met
Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot
landscape strip along all public street frontages. Additional minimum planting strip
widths between the curb and sidewalk are established according to the street
development standards of RMC 4-6-060. Minimum planting strip widths between the
curb and sidewalk are established according to the street development standards of
RMC 4-6-060. Street trees and, at a minimum, groundcover shall be planted within
planting strips pursuant to the following standards, provided there shall be a minimum
of one street tree planted per lot.
a. Trees shall be selected from the City’s Approved Street Tree List based on the width
of the planting strip and the presence or lack of overhead power lines; provided, the
Administrator and City arborist shall each retain the right to reject any proposed
cultivar regardless of whether or not the cultivar is on the City’s Approved Street Tree
List.
b. Street trees shall have a minimum caliper of two inches (2"), and be planted pursuant
to the standards promulgated by the City, which may require root barriers, structured
soils, or other measures to help prevent tree roots from damaging infrastructure.
c. Street trees shall be planted in the center of the planting strip between the curb and
the sidewalk at the following intervals; provided, that, where right-of-way is
constrained, irregular intervals and slight increases or decreases may be permitted or
required. Additionally, trees shall be planted in locations that meet required spacing
distances from facilities located in the right-of-way including, but not limited to,
underground utilities, streetlights, utility poles, traffic signs, fire hydrants, and
driveways; such spacing standards are identified in the City’s Approved Tree List.
Generally, the following spacing is required:
i. Small-sized maturing trees: thirty feet (30') on center;
ii. Medium-sized maturing trees: forty feet (40') on center; and
iii. Large-sized maturing trees: fifty feet (50') on center. Any additional undeveloped
right-of-way areas shall be landscaped unless otherwise determined by the
Administrator. Where there is insufficient right-of-way space or no public frontage,
street trees are required in the front yard subject to approval of the Administrator. A
minimum of two trees are to be located in the front yard prior to final inspection for
the new Single-Family Residence.
Staff Comment: A Conceptual Landscape Plan (Exhibit 9) was included with the
submitted short plat application materials. The submitted landscape plan is based on a
previous five (5)-lot concept. The Conceptual Landscape Plan includes the eight-foot (8’)
wide street tree planting strip between the curb and sidewalk along NE 10th Street and
Hoquiam Avenue NE. Sterling Silver Linden street trees are proposed within the planting
strip along NE 10th Street and Frontier Elm are proposed along Hoquiam Avenue NE.
Both proposed street tree species are on the City’s approved Street Tree list. Ground
cover within the street tree planting strip along NE 10th Street would include bronze
beauty carpet bugle and Vancouver jade kinnikinnick. The Hoquiam Avenue NE street
tree planter strip would also be vegetated with a mix of shrubs (silver princess
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 9 of 25
D_Enclave_Short_Plat_FINAL (002)
euonymus, arctic fire redtwig dogwood, and salal) and ground cover (Vancouver jade
kinnikinnick, sand strawberry, and creeping Oregon grape).
The Conceptual Landscape Plan also includes a ten-foot (10’) wide onsite landscape
strip along the NE 10th Street and Hoquiam Avenue NE frontages. The onsite landscape
strip along Hoquiam Avenue NE would be vegetated with primarily existing trees and
wetland buffer area (see submitted Tree Retention Plan (Exhibit 2)). The west side of
proposed Lot 1 and the north side of Lots 1-4 would be vegetated primarily with shrubs
(prostrate white abelia, white rock rose, arctic fire redtwig dogwood, emerald gaity
euonymus, silver princess euonymus, salal, creeping Oregon grape, pacific wax myrtle,
fire power heavenly bamboo, and Mt. Vernon laurel) and ground cover (burgundy glow
ajuga, and sand strawberry). There are no trees proposed within the ten-foot (10’) wide
onsite landscape strip, however the City’s Landscape Regulations require that this area
be vegetated with a mix of trees, shrubs, and ground cover. Therefore, staff
recommends, as a condition of approval that a detailed landscape plan be submitted at
the time of Construction Permit review. The detailed landscape plan shall include trees,
in addition to the shrubs and groundcover, within the ten-foot (10’) onsite landscape
strip within the proposed lots. The detailed landscape plan shall be submitted to the
Current Planning Project Manager for review and approval prior to the issuance of a
Construction Permit.
The submitted landscape plan did not include landscape details for the proposed storm
drainage facility. Staff recommends, as a condition of approval, that a detailed
landscape plan, compliant with RMC 4-8-120D.12, be provided at the time of
Construction Permit review. The detailed landscape plan shall include but not be limited
to a landscaping buffer along the east side of the stormwater facility. The landscape
buffer shall be vegetated with native evergreen trees, unless otherwise approved by the
Current Planning Project Manager. The detailed landscape plan shall be submitted to
the Current Planning Project Manager for review and approval.
Compliant if
condition of
approval is
met
Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations (4-
4-130) require the retention of 30 percent of trees in a residential development. Tree
credit requirements shall apply at a minimum rate of thirty (30) credits per net acre.
The tree density may consist of existing trees, replacement trees, trees required
pursuant to RMC 4-4-070F1, Street Frontage Landscaping Required, or a combination.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy;
significant trees on slopes greater than twenty percent (20%); significant trees adjacent
to critical areas and their associated buffers; and significant trees over sixty feet (60')
in height or greater than eighteen inches ( 18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved;
other significant native evergreen or deciduous trees; and other significant non- native
trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have
been evaluated for retention and are not able to be retained, unless the alders and/ or
cottonwoods are used as part of an approved enhancement project within a critical
area or its buffer.
Staff Comment: An Arborist Report, prepared by Sound Tree Consulting, dated August
3, 2022 (Exhibit 10) and Tree Retention Plan (Exhibit 2) were submitted with the project
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 10 of 25
D_Enclave_Short_Plat_FINAL (002)
application. According to the submitted report, there are 81 trees located on and
around the project site and within the public right-of-way. Of these trees, six (6) appear
to be located onsite outside of any required critical areas or buffers. Of these six (6)
trees, the applicant is proposing to retain four (4), which would result in the retention
of 67% on onsite significant trees, which would comply with the tree retention
requirements. All trees required to be retained within a subdivision shall be preserved
in the priority order listed below, with Tier 1 being the highest priority. Applications that
propose compliance with a lower priority tier must demonstrate in writing to the
Administrator’s satisfaction that: (i) all reasonable efforts have been taken to preserve
trees utilizing the highest priority tier possible, (ii) that compliance with a higher tier is
not feasible or practical for the project site, and (iii) that the project proposal meets or
exceeds the purposes and intent of the Tree Retention Regulations. Tree preservation
shall be prioritized as follows: Tier 1 – Tree Protection Tract. Protection of trees or
groves by placement within a dedicated tract; or Tier 2 – Tree Protection Easement or
Restrictive Covenant. Protection of trees or groves by recordation of a permanent tree
protection easement (for groves of trees) or a restrictive covenant (for individual trees).
Staff recommends, as a condition of approval, that the applicant demonstrate
compliance with the priority order requirements for tree retention in subdivisions.
There are a number of street trees located along the site’s Hoquiam Ave NE and NE 10th
Street frontages, currently the applicant’s tree retention plan includes the retention of
all street trees. Staff recommends, as a condition of approval, that all existing street
trees along the site’s NE 10th St and Hoquiam Ave NE frontages be retained, unless it is
determined to be infeasible by the Current Planning Project Manager and City Arborist.
The project site has a gross site area of 89,218 square feet (2.05 acres). After the
deduction of 644 square feet for row dedication and 30,888 square feet of wetland, the
project site would have a net area of 57,686 square feet or 1.32 acres. Based on a net
developable area of 1.32 acres, a total of 40 tree credits would be required on the
project site (1.32 acres * 30 tree credits/ac = 39.6 tree credits). To meet the tree credit
requirements, the applicant is proposing to retain Tree 996, a 15” Austrian Pine valued
at 6 credits; Tree 1116, a 14” red pine valued at 6 credits; Tree 1114, a 15” red pine
valued at 6 credits; and Tree 1113, a 16” red pine valued at 7 credits. The proposed
project would retain a total of 25 tree credits on site. To comply with the required 40
tree credits, staff recommends, as a condition of approval, that the applicant provide
an additional 15 tree credits onsite. The additional tree credits may be provided through
the retention of existing trees within the developable area of the project site, or through
the planting of new trees in compliance with the City’s tree credit requirements.
Parking: Parking regulations require that a minimum of two parking spaces be
provided for each detached dwelling.
Driveway cuts are required to be a minimum of 5 feet from property lines and new
driveways may be a maximum of 16 feet in width at the property line. Maximum
driveway slopes shall not exceed fifteen percent (15%); provided, that driveways
exceeding eight percent (8%) shall provide slotted drains at the lower end with positive
drainage discharge to restrict runoff from entering the garage/residence or crossing
any public sidewalk.
Staff Comment: The proposed lots include adequate area to provide the required two
(2) parking spaces per dwelling unit. See FOF 19 regarding joint use driveway conditions
as it relates to driveway cuts.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 11 of 25
D_Enclave_Short_Plat_FINAL (002)
16. Design Standards: Residential Design and Open Space Standards (RMC 4-2-115) are applicable in the R-4,
R-6, R-8 zone. The Standards implement policies established in the Land Use Element of the
Comprehensive Plan. Compliance with Site Design Standards must be demonstrated prior to approval of
the subdivision. Compliance with Residential Design Standards would be verified prior to issuance of the
building permit for the new single-family homes. The proposal is consistent with the following design
standards, unless noted otherwise:
Compliance Design Standards R-8 and Analysis
N/A
Lot Configuration: One of the following is required of preliminary plat applications:
1. Lot width variation of 10 feet (10’) minimum of one per four (4) abutting street-
fronting lots, or
2. Minimum of four (4) lot sizes (minimum of four hundred (400) gross square
feet size difference) for street-fronting lots, or
3. A front yard setback variation of at least five feet (5’) minimum for at least
every four (4) abutting street fronting lots.
Staff Comment: Not applicable, as the proposal is a short plat.
Lots shall be configured to achieve both of the following:
1. The location of stormwater infiltration LID facilities is optimized, consistent
with the Surface Water Design Manual. Building and property line setbacks are
specified in the Surface Water Design Manual for infiltration facilities.
2. Soils with good infiltration potential for stormwater management are
preserved to the maximum extent practicable as defined by the Surface Water
Design Manual.
Staff Comment: See additional drainage discussion below under FOF 20.
Compliance
not yet
demonstrated
Garages: If an attached garage is wider than twenty six feet (26’), at least one (1) garage
door shall be recessed a minimum of four feet (4’) from the other garage door.
Additionally, one of the following is required:
1. The front porch projects in front of the garage a minimum of five feet (5’), and
is a minimum of twelve feet (12’) wide, or
2. The roof extends at least five feet (5') (not including eaves) beyond the front of
the garage for at least the width of the garage plus the porch/stoop area, or
3. The garage is alley accessed, or
4. The garage entry does not face a public and/or private street or an access
easement, or
5. The garage width represents no greater than fifty percent (50%) of the width
of the front facade at ground level, or
6. The garage is detached, or
7. The garage doors contain a minimum of thirty percent (30%) glazing,
architectural detailing (e.g. trim and hardware), and are recessed from the
front façade a minimum of five feet (5’), and from the front porch a minimum
of seven feet (7’).
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 12 of 25
D_Enclave_Short_Plat_FINAL (002)
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Primary Entry: The entry shall include a porch or stoop with a minimum depth of five
feet (5') and minimum height of twelve inches (12") above grade.
Exception: in cases where accessibility (ADA) is a priority, an accessible route may be
taken from a front driveway.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Facade Modulation: One of the following is required:
1. An offset of at least one story that is at least ten feet (10') wide and two feet
(2') in depth on facades visible from the street, or
2. At least two feet (2') offset of second story from first story on one street facing
facade.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Windows and Doors: Windows and doors shall constitute twenty-five percent (25%) of
all facades facing street frontage or public spaces.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Scale, Bulk, and Character: A variety of elevations and models that demonstrate a
variety of floor plans, home sizes, and character shall be used. All of the following are
required:
1. A variety of elevations and models that demonstrate a variety of home sizes,
character, and a diverse streetscape.
2. Abutting, adjacent, and diagonal houses must have differing architectural
elevations.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Roofs: A variety of roof forms appropriate to the style of the home shall be used.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Eaves: Both of the following are required:
1. Eaves projecting from the roof of the entire building at least twelve inches (12")
with horizontal fascia or fascia gutter at least five inches (5") deep on the face
of all eaves, and
2. Rakes on gable ends must extend a minimum of two inches (2") from the
surface of exterior siding materials.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 13 of 25
D_Enclave_Short_Plat_FINAL (002)
Compliance
not yet demonstrated
Architectural Detailing: If one siding material is used on any side of the dwelling that is
two stories or greater in height, a horizontal band that measures at least eight inches
(8") is required between the first and second story.
Additionally, one of the following is required:
1. Three and one half inch (3 1/2") minimum trim surrounds all windows and
details all doors, or
2. A combination of shutters and three and one half inches (3 1/2") minimum trim
details all windows, and three and one half inches (3 1/2") minimum trim
details all doors.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Materials and Color: For subdivisions and short plats, abutting homes shall be of
differing color. Color palettes for all new dwellings, coded to the home elevations, shall
be submitted for approval.
Additionally, one of the following is required:
1. A minimum of two (2) colors is used on the home (body with different color
trim is acceptable), or
2. A minimum of two (2) differing siding materials (horizontal siding and shingles,
siding and masonry or masonry-like material, etc.) is used on the home. One
alternative siding material must comprise a minimum of thirty percent (30%)
of the street facing facade. If masonry siding is used, it shall wrap the corners
no less than twenty four inches (24").
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
17. Critical Areas: Project sites which contain critical areas are required to comply with the Critical Areas
Regulations (RMC 4-3-050). The proposal is consistent with the Critical Areas Regulations, if all conditions
of approval are complied with:
Compliance Critical Areas Analysis
Compliant if
conditions of
approval are met
Wetlands: The following buffer requirements are applicable to wetlands in accordance
with RMC 4-3-050.G.2:
Wetland
Category Buffer Width
Structure
Setback beyond
buffer
High
Habitat
Function
(8-9 points)
Moderate
Habitat
Function
(5-7 points)
Low Habitat
Function
(3-4 points)
All
Other
Scores
15 ft. Category I –
Bogs & Natural
Heritage
Wetlands
200 ft.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 14 of 25
D_Enclave_Short_Plat_FINAL (002)
Category I – All
Others 200 ft. 150 ft. 115 ft. 115 ft.
Category II 175 ft. 150 ft. 100 ft. n/a
Category III 125 ft. 100 ft. 75 ft. n/a
Category IV 50 ft. n/a
Staff Comment: The applicant submitted a Wetland Report, prepared by The Watershed
Company, dated May 26, 2022 (Exhibit 3) with the project application materials.
According to the submitted wetland report, a Category III depressional wetland
(Wetland A) with a habitat score of four (4) points is located on the south portion of the
project site. According to RMC 4-3-050G Category III wetlands with a low habitat score
of 3-4 points require a standard buffer of 75 feet. The tree stratum of Wetland A is
dominated by red alder (Alnus rubra), black cottonwood (Populus balsamifera), and
Pacific willow (Salix lucida). The shrub stratum is dominated by Sitka willow (Salix
sitchensis), twinberry (Lonicera involucrata), red-osier dogwood (Cornus sericea),
salmonberry (Rubus spectabilis), hardhack (Spiraea douglasii), and Himalayan
blackberry. The herbaceous stratum is dominated by reed canary grass, common cattail
(Typha latifolia), slough sedge (Carex obnupta), soft-rush (Juncus effusus), lady fern
(Athyrium filix-femina), horsetail (Equisetum telmateia), and creeping butter cup
(Ranunculus repens). As part of the proposed short plat application, the applicant is
requesting a twenty-five percent (25%) reduction in the 75-foot standard buffer in
accordance with RMC 4-3-050I.3.a. Staff has received comments from the Duwamish
Tribe (Exhibit 4) requesting that the proposed buffer reduction not be approved.
In order to approve a buffer reduction in accordance with RMC 4-3-050I.c, the reviewing
official must find that the proposal meets all the following criteria: The reduced buffer
will function at a higher level than the standard buffer; and an enhanced buffer shall
never be less than seventy five percent (75%) of the standard width at its narrowest
point; and the buffer area has less than fifteen percent (15%) slopes and no direct or
indirect, short-term or long-term, adverse impacts to regulated wetlands, as
determined by the City, and the proposal shall rely upon a site-specific evaluation and
documentation of buffer adequacy based upon Wetlands in Washington State, Volume
1: A Synthesis of the Science (Ecology Publication No. 05-06-006, March 2005) and
Wetlands in Washington State, Volume 2: Managing and Protecting Wetlands (Ecology
Publication No. 04-06-008, April 2005), or similar approaches; and the proposed buffer
standard is based on consideration of the best available science as described in WAC
365-195-905. The submitted Wetland Report (Exhibit 3) included a justification
addressing each of the above criteria. According to the submitted report, the existing
buffer consists of maintained lawn, ornamentals, and monocultures of reed canary
grass and Himalayan blackberry. The buffer is proposed to be enhanced with planting
of native trees, shrubs, and ground cover to increase native vegetation density and
diversity, improving the function of the buffer. The proposed buffer would be reduced
to 56.25 feet, which is 75% of the standard buffer required. The survey of existing site
conditions (L001 of the attached mitigation plan within Exhibit 3) shows no areas within
the standard wetland buffer exceeding fifteen percent slopes. The mitigation plan has
been developed in consideration of the Ecology guidance documents reference above,
as well as the updated Ecology mitigation guidance document: Wetland Mitigation in
Washington State Part 1: Agency Policies and Guidance Version 2 (Ecology Publication
21-06-003, April 2021). The proposal addresses mitigation sequencing per the guidance
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 15 of 25
D_Enclave_Short_Plat_FINAL (002)
documents and does not require additional compensatory mitigation for direct or
indirect wetland impacts. The plan includes appropriate site-specific species
compositions, goals and performance standards, monitoring plan, and contingency
plan. The buffer averaging plan has been prepared according to the best available
science.
Staff has reviewed the buffer reduction request and concurs that the request would
comply with the required criteria as discussed above. However, there appears to be
additional area available between the requested reduced buffer area and the proposed
lots and stormwater detention tract that could also be retained and enhanced as
wetland buffer area. In addition, as previously discussed above under FOF 15, staff is
recommending that the proposed lot depth be reduced down from 93 feet to 80 feet,
which is the minimum depth for the R-8 zone, to accommodate additional wetland
buffer area. The proposed width of each lot is 67 feet coupled with the 80-foot depths
would result in lot sizes and dimensions that meet the zone’s requirements. Staff finds
no compelling reason to reduce the buffer width to the maximum of 25 percent in order
to accommodate increased depths for the proposed lots. Therefore, staff recommends
a partial approval of the requested buffer reduction. Staff recommends, as a condition
of approval that the additional buffer area located within the expanded Tract A,
between the reduced buffer shown on the civil plan set (Exhibit 2) and the proposed
reduced boundaries of Lots 1-4 and the boundaries of Tract B also be enhanced and
retained as part of the reduced wetland buffer area. The reduced buffer would then
extend to the full limits of the expanded Tract A. A final mitigation plan for the
enhanced buffer shall be submitted at the time of Construction Permit Review for
review and approval by the Current Planning Project Manager and a surety device shall
be required to ensure performance consistent with RMC 4-1-230. The enhanced buffer
area shall be monitored for a minimum of five (5) years, monitoring report shall be
submitted quarterly for the first year and thereafter annually for the next four (4) years.
The wetland and buffer area shall be retained within a Native Growth Protection Area
(Tract A). The applicant shall create a tract via the subdivision and record a permanent
and irrevocable covenant running with the land or deed restriction on the property title
of any critical area management tract or tracts created as a condition of a permit. Such
covenant or deed restriction(s) shall prohibit development, alteration, or disturbance
within the tract except for purposes of habitat enhancement as part of an enhancement
project which has received prior written approval from the City, and from any other
agency with jurisdiction over such activity. A covenant running with the land shall be
placed on the tract restricting its separate sale. Each abutting lot owner or the
homeowners’ association shall have an undivided interest in the tract. Staff
recommends, as a condition of approval that a draft covenant or deed restriction be
submitted to the Current Planning Project Manager for review and approval at the time
of Construction Permit Review.
Permanent fencing of the native growth protection area containing critical area and
buffers is required. The common boundary between a native growth protection area
and the abutting land must be permanently identified. This identification shall include
permanent wood or metal signs on treated or metal posts. Sign locations and size
specifications shall be approved by the City. Suggested wording is as follows:
“Protection of this natural area is in your care. Alteration or disturbance is prohibited
by law.” Staff recommends, as a condition of approval that a fencing and signage detail
around the perimeter of Tract A be submitted at the time of Construction Permit Review
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 16 of 25
D_Enclave_Short_Plat_FINAL (002)
for review and approval by the Current Planning Project Manager. The fencing and
signage shall be installed prior to the recording of the Short Plat.
18. Modification Analysis: The applicant is requesting a modification from RMC 4-6-060 along the project
site’s Hoquiam Ave NE frontage. Hoquiam Ave NE is classified as a collector arterial street with an existing
ROW of approximately 60 feet per the King County Assessor Map. Per RMC 4-6-060, the minimum right-
of-way width for a Collector Arterial street with 2 lanes is 83 feet that includes a 46 foot paved road (23
feet from centerline), a 0.5 foot curb, an 8 foot planting strip, an 8 foot sidewalk, street trees and storm
drainage improvements. The applicant is requesting a modification that would include the retention of
the existing pavement width of 36 feet from curb to curb and reduce the required sidewalk width to a 5-
foot sidewalk. This would provide a future right-of-way of 64 feet and would require the project to
dedicate 2 feet of right-of-way. The proposal is compliant with the following modification criteria,
pursuant to RMC 4-9-250.D.2, if all conditions of approval are met. Therefore, staff is recommending
approval of the requested modification, subject to conditions as noted below:
Compliance Modification Criteria and Analysis
a. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and
the proposed modification is the minimum adjustment necessary to implement
these policies and objectives.
Staff Comment: See FOF 14, Comprehensive Plan Analysis. The Land Use Element has
applicable policies listed under a separate section labeled Promoting a Safe, Healthy,
and Attractive Community. These policies address walkable neighborhoods, safety, and
shared uses. The intent of the policies is to promote new development with walkable
places that support grid and flexible grid street and pathway patterns, and are visually
attractive, safe, and healthy environments. The proposed frontage improvement
section along Hoquiam Ave NE has been revied by the City’s Transportation Division,
who supports the requested modified street section. The City concurs that the requested
modification would meet the intent of these policies.
Compliant if
condition of
approval is
met
b. Will meet the objectives and safety, function, appearance, environmental
protection and maintainability intended by the Code requirements, based upon
sound engineering judgment.
Staff Comment: The applicant contends the modified Hoquiam Ave NE section complies
with the recommended section as determined by the City’s Transportation Division and
would comply with the objectives and safety, function, appearance, environmental
protection and maintainability intended by City Code.
Staff concurs the proposed modification would meet the objectives of function and
maintainability intended by the code requirements. The City’s Public Works
Transportation Division has reviewed Hoquiam Ave NE and the surrounding area and
have determined that a modified collector arterial street section is more suitable for the
portion of Hoquiam Ave NE adjacent to the site. The recommended section includes the
following street section along Hoquiam Ave NE: a pavement width of 36 feet from curb
to curb to remain and a reduction in sidewalk width to a 5-foot sidewalk. This would
provide a future right-of-way of 64 feet and would require the project to dedicate 2 feet
of right-of-way. A portion of the project site’s Hoquiam Ave NE frontage would abut the
onsite wetland and buffer located on the project site. The location of the proposed
frontage improvements would be located within the existing developed roadway
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 17 of 25
D_Enclave_Short_Plat_FINAL (002)
section and would qualify for an exemption from the City’s Critical Areas Regulations
(RMC 4-3-0503.e.iv), provided the proposal complies with the following: the work does
not increase the footprint of the structure, line or street by more than ten percent (10%)
within the critical area and/or buffer areas, and occurs in the existing right-of-way
boundary or easement boundary; restoration shall be conducted where feasible.
Compensation for impacts to buffers shall include enhancement of the remaining buffer
area along the impacted area where there is enhancement opportunity; the
Administrator determines that, based on best judgment, a person would not: (i) be able
to meaningfully measure, detect, or evaluate insignificant effects; or (ii) expect
discountable effects to occur; this exemption allows for ten percent (10%) maximum
expansion total, life of the project. After the ten percent (10%) expansion cap is reached,
future improvements are subject to all applicable provisions of this Section. Staff has
reviewed the request, as the proposed work would occur within the existing improved
roadway section and would not extend beyond the boundaries of the existing
engineered slope that supports the existing improvements, the proposal would qualify
for this exemption. To further reduce any potential direct impacts to Wetland A, staff
recommends, as a condition of approval that where the proposed sidewalk would abut
Wetland A, that the sidewalk shall be constructed adjacent to the curb.
In addition, all Critical Areas Exemptions are required to comply with the following
criteria: The activity is not prohibited by this or any other provision of the Renton
Municipal Code or State or Federal law or regulation; the activity will be conducted
using best management practices as specified by industry standards or applicable
Federal agencies or scientific principles; impacts are minimized and, where applicable,
disturbed areas are immediately restored; where water body or buffer disturbance has
occurred in accordance with an exemption during construction or other activities,
revegetation with native vegetation shall be required; and if a hazardous material,
activity, and/or facility that is exempt pursuant to this Section has a significant or
substantial potential to degrade groundwater quality, then the Administrator may
require compliance with the Wellhead Protection Area requirements of this Section
otherwise relevant to that hazardous material, activity, and/or facility. Such
determinations will be based upon site and/or chemical-specific data. As previously
discussed above, the proposed frontage improvements would meet the exemption
criteria or work within an existing street (RMC 4-3-0503.e.iv) and would not be
prohibited by Code; the construction of the frontage improvements would utilize best
management practices as specified by industry standards, as conditioned above the
impacts to the wetland would be minimized by relocating the sidewalk adjacent to the
curb, it is not anticipated that the proposed work would result in water disturbance, nor
is it anticipated that the proposed work would have the substantial potential to degrade
groundwater quality. Therefore, the proposed frontage improvements would qualify for
an exemption from the City’s Critical Areas Regulations.
The proposed modification would meet the Transportation Division’s established
corridor plan for this section of Hoquiam Ave NE and could conform to the intended
purpose of the code by providing a complete street cross section.
c. Will not create substantial adverse impacts to other property(ies) in the vicinity.
Staff Comment: There are no identified adverse impacts to other properties from the
requested modification. New frontage improvements would be installed along the
subject property’s abutting unimproved ROW.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 18 of 25
D_Enclave_Short_Plat_FINAL (002)
d. Conforms to the intent and purpose of the Code.
Staff Comment: See comments under criterion ‘b’.
e. Can be shown to be justified and required for the use and situation intended.
Staff Comment: See comments under criterion ‘b’.
19. Compliance with Subdivision Regulations: RMC 4-7 Provides review criteria for the subdivisions. The
proposal is consistent with the following subdivision regulations if all conditions of approval are complied
with:
Compliance Subdivision Regulations and Analysis
Compliant if
condition of
approval is
met
Access: Each lot must have access to a public street or road. Access may be by a shared
driveway per the requirements of RMC 4-6-060 Street Standards.
Alley access is the preferred street pattern in the R-8 zone.
The maximum width of single loaded garage driveways shall not exceed nine feet (9')
and double loaded garage driveways shall not exceed sixteen feet (16').
Staff Comment: Access to the lots is proposed via individual driveway access off NE 10th
St. Alley access is the preferred street pattern in the R-8 zone, except when there are
environmental constraints, which would prevent alley access. A wetland is located
onsite and staff is recommending that the lot dimensions be reduced to accommodate
a larger wetland buffer onsite. Due to the wetland and buffer requirements, it is
determined that alley access to the proposed lots would not be feasible. Alley access
provides many benefits to circulation and the landscape in residential neighborhoods
including eliminating the need for individual curb cuts along property frontages thereby
reducing pedestrian/vehicle conflicts and increasing planting area for street trees. To
reduce the number of curb cuts, that would provide access to the proposed lots, staff
recommends, as a condition of approval that the four individual driveways proposed be
consolidated to two joint-use driveways. A revised short plat layout showing the joint-
use driveways shall be submitted at the time of Construction Permit Review to the
Current Planning Project Manager for review and approval.
N/A
Blocks: Blocks shall be deep enough to allow two (2) tiers of lots.
Staff Comment: Not applicable, no blocks are proposed. Projects are exempt from block
depth regulation when the location and extent of environmental constraints prevent a
standard plat land configuration.
Lots: The size, shape, orientation, and arrangement of the proposed lots comply with
the requirements of the Subdivision Regulations and the Development Standards of the
R-8 zone and allow for reasonable infill of developable land.
All of the proposed lots shall meet the requirements for minimum lot size, depth, and
width.
Width between side lot lines at their foremost points (i.e., the points where the side lot
lines intersect with the street right-of-way line) shall not be less than eighty percent
(80%) of the required lot width except in the cases of (1) pipestem lots (or flag lot),
which shall have a minimum width of twenty feet (20') and (2) lots on a street curve or
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 19 of 25
D_Enclave_Short_Plat_FINAL (002)
the turning circle of cul-de-sac (radial lots), which shall be a minimum of thirty five feet
(35').
No residentially zoned lot shall have a depth-to-width ratio greater than four-to-one
(4:1).
Pipestem lots may be permitted for new plats to achieve the minimum density within
the Zoning Code when there is no other feasible alternative to achieving the minimum
density.
Staff Comment: As conditioned, all proposed lots would comply with the minimum area
and dimensional standards of the R-8 zone (see FOF 15 and 17). The lots are rectangular
in shape and the front yard areas of the proposed lots would be oriented towards the
north, facing NE 10th St.
Compliant if
condition of
approval is
met
Streets: The proposed street system shall extend and create connections between
existing streets per the Street Standards outlined in RMC 4-6-060 Street Standards.
Staff Comment: The proposed development has frontage along NE 10th St and Hoquiam
Ave NE. The Ne 10th St frontage is located along the north property line. NE 10th St is
classified as a Residential Access street with an existing right-of-way (ROW) of
approximately 51 feet per the King County Assessors Map. NE 10th Street currently
contains a meandering 5-foot sidewalk. Per RMC 4-6-060, the minimum ROW width for
a Residential Access street is 53 feet that includes a 26-foot paved road with 6-foot wide
parking lane (13 feet from centerline), a curb bulb-out, a 0.5-foot curb, an 8-foot
planting strip, a 5-foot sidewalk, street trees and storm drainage improvements. No
dedication is anticipated. The applicant will construct half-street improvements along
NE 10th St as required by RMC 4-6-060C.
To facilitate and delineate on street parking along NE 10th St and Hoquiam Ave NE, staff
recommends, as a condition of approval that the civil plans be revised to provide a curb
bulb-out at the intersection of Hoquiam Ave NE and NE 10th St. The revised civil plans
shall be submitted at the time of Construction Permit review for review and approval by
the Current Planning Project Manager and Development Engineering Plan Reviewer.
The proposed project fronts Hoquiam Ave NE along the east property line. Hoquiam Ave
NE is classified as a Collector Arterial Street. The existing ROW width is approximately
60 feet as measured using the King County Assessor’s Map. There are no existing
frontage improvements along the Hoquiam Ave NE frontage. a. To meet the City’s
complete street standards for Collector Arterial streets, minimum ROW is 83 feet.
Dedication of 11.5 feet of ROW fronting the site will be required. Per City code 4-6-060,
half street improvements shall include a pavement width of 46 feet (23 feet from
centerline), a 0.5-foot curb, an 8-foot planting strip, an 8-foot sidewalk, street trees and
storm drainage improvements. However, a modification to these standards was
requested, see previous discussion above under FOF 18.
The proposal evaluated for compliance with Transportation Concurrency and it was
determined that the proposed short plat would pass the Transportation Concurrency
Test (Exhibit 12).
Each new lot is subject to a transportation impact fee, with credit given for the existing
single-family residence. The 2023 transportation impact fee is $12,208.54 per single-
family home. Assessed fees for the future home will be based on the City of Renton
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 20 of 25
D_Enclave_Short_Plat_FINAL (002)
Fee Schedule at the time of building permit issuance. The fee is paid at the time of
building permit issuance.
Relationship to Existing Uses: The proposed project is compatible with existing
surrounding uses.
Staff Comment: As previously discuss, the proposed lots would comply with the
minimum area and dimensional requirements of the R-8 zone, all lots would front on a
public street and would be compatible with other single-family development in the
surrounding area.
20. Availability and Impact on Public Services:
Compliance Availability and Impact on Public Services Analysis
Police and Fire: Police and Fire Prevention staff indicates that sufficient resources exist
to furnish services to the proposed development; subject to the condition that the
applicant provides Code required improvements and fees. Current Fire impact fees are
$829.77 per single-family unit. The fee in effect at the time of building permit issuance
will be required.
Schools: It is anticipated that the Renton School District can accommodate any additional
students generated by this proposal at the following schools: Hilltop Heritage
Elementary, Risdon Middle School and Hazen High School. Any new students from the
development attending the elementary school would cross Hoquiam Ave NE and walk
along the existing sidewalk or paved walkway along NE 10th St to Duvall Ave NE where
they would turn north and walk along the existing sidewalk to the elementary school,
which is located approximately 0.4 miles from the project site.
Any new students from the proposed development would be bussed to their middle
school. The middle school stop is located at the intersection of NE 10th St and Hoquiam
Ave NE, right at the northwest corner of the project site. Any new middle school students
would walk along the sidewalks proposed to be constructed as a result of the
development to the bus stop.
Any new high school students would walk to school. students from the development
attending the elementary school would cross Hoquiam Ave NE and walk along the
existing sidewalk abutting the elementary school property, the school itself is
approximately 1,000 feet from the project site.
The proposed project includes the installation of frontage improvements along the NE
10th St and Hoquiam Ave NE frontages, including sidewalks. There would be a safe
walking route to school or to the bus stop for any new students via sidewalks and or
paved shoulders along the roadways.
A School Impact Fee, based on new single-family lots, will be required in order to mitigate
the proposal’s potential impacts to the Renton School District. The fee is payable to the
City as specified by the Renton Municipal Code. Currently the fee is assessed at $2,911.00
(plus a 5% surcharge fee) per single-family residence however the fee in effect at the
time of building permit issuance will be required.
Parks: A Park Impact Fee would be required for the future houses. The current Park
Impact Fee is $3,276.44 however the fee in effect at the time of building permit issuance
will be required.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 21 of 25
D_Enclave_Short_Plat_FINAL (002)
Storm Water: An adequate drainage system shall be provided for the proper drainage of
all surface water.
Staff Comment: A Preliminary Drainage Plan included in the conceptual civil plan set
(Exhibit 2) and Technical Information Report (TIR) (Exhibit 14), prepared by Pacific Land
Engineering. dated September 1, 2023 were included with the project application
materials. Based on the submitted report, the applicant is proposing an underground
storm drainage vault to mitigate for surface water runoff generated by the proposed
development.
Staff received a public comment (Exhibit 5) during the 14-day public comment period. The
public comment expressed concerns with respect to drainage. The proposed project
would be subject to the 2022 City of Renton Surface Water Design Manual (RSWDM),
which it is anticipated would not exacerbate an existing drainage issues on and around
the project site.
Based on the City of Renton’s flow control map, the site falls within the Flow Control
Duration Standard- Matching Forested and is within the May Creek Drainage Basin. The
TIR needs to implement rationale showing compliance with Core Requirements, including
wetland hydrology protection. The TIR needs to be formatted in accordance with Section
2.3.1.1 of the 2022 RSWDM.
A geotechnical report (Exhibit 13) dated July 17, 2020, prepared by Nelson Geotechnical
Associates, Inc., was also provided with the Land Use Application materials. The report
discusses the soil and groundwater characteristics of the site and provides
recommendations for project design and construction. Geotechnical recommendations
presented in this report concluded that stormwater infiltration is feasible within the
native advance outwash soils within the site at depth, but not feasible or very limited
within the upper glacial till.
Storm drainage improvements along all public street frontages are required to conform
to the City’s street and stormwater conveyance standards. Any new storm drain installed
on or off-site shall be designed and sized in accordance with standards found in Chapter
4 of the 2022 RSWDM and shall account for the total upstream tributary area, assuming
developed conditions for onsite tributary areas and existing conditions for any offsite
tributary areas
All projects that add more than 5,000 square feet of pollution generating impervious
surface (PGIS) that is not fully dispersed and less than 0.75 acre of pollution generating
pervious surface that is not fully dispersed require water quality treatment.
A construction Storm Water General Permit from the Department of Ecology will be
required as clearing and grading of the site is shown to exceed one acre.
There is a 2023 system Development Charge of $2,300 per new single-family residence.
SDC fees are payable at construction permit issuance.
Water: Water service is provided by King County Water District #90. The site is located
outside of a Wellhead Protection Area. A water availability certificate from King County
Water District #90 is required as part of the Civil Construction Permit Application.
Sanitary Sewer: Wastewater service is provided by the City of Renton. There is an
existing 8-inch PVC gravity wastewater main located in NE 10th Street. There is an
existing 8-inch PVC gravity wastewater main located at the east side of the site. An eight-
inch (8”) sewer main extension across the site frontage on Hoquiam Ave NE is required.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 22 of 25
D_Enclave_Short_Plat_FINAL (002)
A separate sewer stub will be required for each new lot off the existing sewer main
located within NE 10th St. All new stubs shall be a minimum of six-inches (6”). All stubs
shall flow by gravity to the main at a minimum slope of 2%.
The development is subject to applicable wastewater system development charges
based on the size of the new domestic water to serve the project. SDC fee for a 1-inch
meter is $3,650.00 per meter. The total fee is $14,600 for (4) 1-inch meters. This is
payable at construction permit issuance.
The East Renton Special Assessment District fee (SAD) fee will be applicable on the
project. The SAD fee rate when it was established in 1996 was $224.52 plus interest per
lot. As of 10/25/2016, the SAD fee rate per lot is $316.80, the SAD has reached its peak
Assessment Period. No additional interest will accrue. The rate that will be applicable on
the issuance day of the utility construction permit will be applicable on this project.
I. CONCLUSIONS:
1. The subject site is located in the Residential Medium Density (MD) Comprehensive Plan designation and
complies with the goals and policies established with this designation, see FOF 14.
2. The subject site is located in the Residential-8 (R-8) zoning designation and complies with the zoning and
development standards established with this designation provided the applicant complies with City Code
and conditions of approval, see FOF 15.
3. The proposed short plat and street standards modification complies with the Residential Design and Open
Space Standards provided the applicant complies with City Code and conditions of approval, see FOF 16.
4. The proposed short plat and street standards modification complies with the Critical Areas Regulations
provided the applicant complies with City Code and conditions of approval, see FOF 17.
5. The proposed short plat and street standards modification complies with the Modification Criteria
provided the applicant complies with City Code and conditions of approval, see FOF 18.
6. The proposed short plat and street standards modification complies with the subdivision regulations as
established by City Code and state law provided all advisory notes and conditions are complied with, see
FOF 19.
7. The proposed short plat and street standards modification complies with the street standards as
established by City Code, provided the project complies with all advisory notes and conditions of approval
contained herein, see FOF 19.
8. There are safe walking routes to the school bus stop, see FOF 20.
9. There are adequate public services and facilities to accommodate the proposed short plat and street
standards modification, see FOF 20.
10. Key features which are integral to this project include an underground stormwater detention vault and
wetland buffer enhancement.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 23 of 25
D_Enclave_Short_Plat_FINAL (002)
J. DECISION:
The Enclave Short Plat and street standards modification, File No. LUA23-000036, SHPL-A, MOD, ECF, as
depicted in Exhibit 2, is approved and is subject to the following conditions:
1. All lots shall have a common undivided interest in proposed Tracts A and B and a maintenance agreement
be established. A draft maintenance agreement for all common improvements shall be submitted at the
time of Construction Permit Review for the review and approval of the Current Planning Project Manager
and City Attorney.
2. The lot depth of the proposed lots shall be reduced to the minimum required depth of 80 feet and the
wetland buffer and Tract A boundary be extended to the north an additional 13 feet.
3. The existing home and detached accessory structured shall be removed prior to the recording of the short
plat. A demolition permit shall be obtained and all required inspection completed prior to the recording
of the short plat.
4. A detailed landscape plan shall be submitted at the time of Construction Permit review. The detailed
landscape plan shall include trees, in addition to the proposed shrubs and groundcover, within the ten-
foot (10’) onsite landscape strip within the proposed lots. The detailed landscape plan shall be submitted
to the Current Planning Project Manager for review and approval prior to the issuance of a Construction
Permit.
5. The detailed landscape plan shall include but not be limited to a landscaping buffer along the east side of
the stormwater facility. The landscape buffer shall be vegetated with native evergreen trees, unless
otherwise approved by the Current Planning Project Manager. The detailed landscape plan shall be
submitted to the Current Planning Project Manager for review and approval.
6. The applicant shall demonstrate compliance with the following priority order requirements for tree
retention within subdivisions. Trees required to be retained within a subdivision shall be preserved in the
priority order listed below, with Tier 1 being the highest priority. Applications that propose compliance
with a lower priority tier must demonstrate in writing to the Administrator’s satisfaction that: (i) all
reasonable efforts have been taken to preserve trees utilizing the highest priority tier possible, (ii) that
compliance with a higher tier is not feasible or practical for the project site, and (iii) that the project
proposal meets or exceeds the purposes and intent of the Tree Retention Regulations. Tree preservation
shall be prioritized as follows: Tier 1 – Tree Protection Tract. Protection of trees or groves by placement
within a dedicated tract; or Tier 2 – Tree Protection Easement or Restrictive Covenant. Protection of trees
or groves by recordation of a permanent tree protection easement (for groves of trees) or a restrictive
covenant (for individual trees).
7. All existing street trees along the site’s NE 10th St and Hoquiam Ave NE frontages shall be retained, unless
it is determined to be infeasible by the Current Planning Project Manager and City Arborist.
8. The applicant shall provide an additional 15 tree credits onsite. The additional tree credits may be
provided through the retention of existing trees within the developable area of the project site, or through
the planting of new trees in compliance with the City’s tree credit requirements.
9. The additional buffer area located within the expanded Tract A, between the reduced buffer shown on
the civil plan set and the reduced boundaries of Lots 1-4 and the boundaries of Tract B shall also be
enhanced and retained as part of the reduced wetland buffer area. The reduced buffer would then extend
to the full limits of the expanded Tract A. A final mitigation plan for the enhanced buffer shall be submitted
at the time of Construction Permit Review for review and approval by the Current Planning Project
Manager and a surety device shall be required to ensure performance consistent with RMC 4-1-230. The
enhanced buffer area shall be monitored for a minimum of five (5) years, monitoring report shall be
submitted quarterly for the first year and thereafter annually for the next four (4) years.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 24 of 25
D_Enclave_Short_Plat_FINAL (002)
10. The applicant shall create a tract via the subdivision and record a permanent and irrevocable covenant
running with the land or deed restriction on the property title of any critical area management tract or
tracts created as a condition of a permit. Such covenant or deed restriction(s) shall prohibit development,
alteration, or disturbance within the tract except for purposes of habitat enhancement as part of an
enhancement project which has received prior written approval from the City, and from any other agency
with jurisdiction over such activity. A covenant running with the land shall be placed on the tract restricting
its separate sale. Each abutting lot owner or the homeowners’ association shall have an undivided interest
in the tract. A draft covenant or deed restriction be submitted to the Current Planning Project Manager
for review and approval at the time of Construction Permit Review.
11. Permanent fencing of the native growth protection area containing critical area and buffers is required.
The common boundary between a native growth protection area and the abutting land must be
permanently identified. This identification shall include permanent wood or metal signs on treated or
metal posts. Sign locations and size specifications shall be approved by the City. Suggested wording is as
follows: “Protection of this natural area is in your care. Alteration or disturbance is prohibited by law.” A
fencing and signage detail around the perimeter of Tract A shall be submitted at the time of Construction
Permit Review for review and approval by the Current Planning Project Manager. The fencing and signage
shall be installed prior to the recording of the Short Plat.
12. Where the proposed sidewalk would abut Wetland A along Hoquiam Ave NE, that the sidewalk shall be
constructed adjacent to the curb.
13. The four (4) individual driveways proposed shall be consolidated to two (2) joint-use driveways. A
revised short plat layout showing the joint-use driveways shall be submitted at the time of Construction
Permit Review to the Current Planning Project Manager for review and approval.
14. The civil plans shall be revised to provide a curb bulb-out at the intersection of Hoquiam Ave NE and NE
10th St. The revised civil plans shall be submitted at the time of Construction Permit review for review
and approval by the Current Planning Project Manager and Development Engineering Plan Reviewer.
DATE OF DECISION ON LAND USE ACTION:
SIGNATURE:
Matthew Herrera, Acting Planning Director Date
TRANSMITTED on October 2, 2023 to the Owner/Applicant/Contact:
Owner: Contact:
Vijay Kakubal and Ramesh
Vudathu
VK Ventures, LLC
3712 77th Ave SE
Mercer Island, WA 98040
Mazen Haidar, PE
Pacific Land Engineering
13617 SE 18th St
Bellevue, WA 98005
TRANSMITTED on October 2, 2023 to the Parties of Record:
Raul Motta
933 Ilwaco Pl NE
Renton, WA 98059
raulmott@hotmail.com
Duwamish Tribe
Preservationdept@duwamishtribe.org
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
10/2/2023 | 5:09 PM PDT
City of Renton Department of Community & Economic Development
Enclave Short Plat
Administrative Report & Decision
LUA23-000036, SHPL-A, MOD, ECF
Report of October 2, 2023 Page 25 of 25
D_Enclave_Short_Plat_FINAL (002)
TRANSMITTED on October 2, 2023 to the following:
Vanessa Dolbee, Interim CED Administrator
Brianne Bannwarth, Development Engineering Director
Gina Estep, Economic Development Director
Nate Janders, Development Engineering Manager
Anjela Barton, Fire Marshal
K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION:
The administrative land use decision will become final if the decision is not appealed within 14 days of the decision
date.
APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing
Examiner on or before 5:00 PM on October 16, 2023. An appeal of the decision must be filed within the 14-day
appeal period (RCW 43.21.C.075(3); WAC 197-11-680). Appeals must be submitted electronically to the City Clerk
at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee,
normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted
electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals
to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process
may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov.
EXPIRATION: The Administrative Short Plat decision will expire five (5) years from the date of decision. A single
one (1) year extension may be requested pursuant to RMC 4-7-070.M.
RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by
the approval body. The approval body may modify his decision if material evidence not readily discoverable prior
to the original decision is found or if he finds there was misrepresentation of fact. After review of the
reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will
be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal
within the 14-day appeal time frame.
THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may
occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the
Hearing Examiner as well. All communications after the decision/approval date must be made in writing through
the Hearing Examiner. All communications are public record and this permits all interested parties to know the
contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of
this doctrine could result in the invalidation of the appeal by the Court.
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6
CITY OF RENTON
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT
ADMINISTRATIVE REPORT & DECISION
EXHIBITS
Project Name:
Enclave Short Plat
Land Use File Number:
LUA23-000036, SHPL-A, MOD, ECF
Date of Report
October 2, 2023
Staff Contact
Jill Ding
Senior Planner
Project Contact/Applicant
Mazen Haidar, PE
Pacific Land Engineering
13617 SE 18th St, Bellevue,
WA 98005
Project Location
980 Hoquiam Ave NE,
Renton, WA 98059
The following exhibits are included with the Administrative report:
Exhibits 1-6: ERC Report and Exhibits
Exhibit 7: Administrative Decision
Exhibit 8: SEPA Determination of Non-Significance
Exhibit 9: Landscape Plan
Exhibit 10: Arborist Report, prepared by Sound Tree Consulting, dated August 3, 2022
Exhibit 11: Street Standards Modification Request
Exhibit 12: Transportation Concurrency Memo
Exhibit 13: Geotechnical Report, dated July 17, 2020, prepared by Nelson Geotechnical Associates,
Inc.
Exhibit 14: Technical Information Report (TIR), prepared by Pacific Land Engineering. dated
September 1, 2023
DocuSign Envelope ID: F2DB334A-48F2-4B97-95FB-B7C2F52E81C6