Loading...
HomeMy WebLinkAbout7_Site Plan _230927_v1S B B B S H E D HO U SE #5 1 B U ILDI N G #4 3 ~ ~~1 HH AA 1' BACK OF SIDEWALK LANDSCAPE8' - 0"SIDEWALK8' - 0"1' - 0"AIRPORT WAY S. TILLICUM ST TRASH ROOM EXIT PROPERTY LINE AFTER DEDICATION EXISTING RESTAURANTLOGAN AVE SOUTHPEDESTRAIN ENTRY TO LOBBY 3500 lbs ELEV RESIDENTIAL LOBBY KEEP EXISTING CURB VEHICULAR PARKING ENTRANCE CD -ZONERESIDENTIAL R-8 ZONE CD -ZONE 8 30' RIGHT OF WAY EXIT 12' WIDE X 10 ' HIGH OVERHEAD SECTION DOOR EXISTING TREE TO REMAIN EXISTING TREES TO REMAIN RISER RM. STAIR 1 STAIR 2 CA -ZONE VEHICULAR ENTRANCE TO PARKING GARAGE AND FIRE ACCESS R.O.W.16'-0"3 5 COMPACT 8 STALLS 15 % SLOPE -2 WAY DRIVE RAMP UP TO MEZZANINE COVERED PARKING GARAGE 20' WIDE FIRE ACCESS 14'-6" CLEAR HEIGHT UP 21'-2"21'-10"9'-6"32'-8"24'-0"40'-0"12'-10" 1'-6"21'-0"1'-6"12'-0"30'-4"19'-8"40'-2"24'-0"52'-10" COMMERCIAL BIKE ROOM 156'-6" BIKE COMM. PLAZA TREES/ SEATING/ PLAZA TREES/ SEATING/ PAVING COMMERCIAL N 87 *30' 12" W 160.06'N 01 *40' 16" E 100.03'119'-0" STANDARD 6 ' - 0 "N 01 *40' 49"E 100.03'20'-6"62'-5 1/4" 20'-0" TRASH CHUTE 5'-0"46'-0"37'-0"STANDARD 11 16'-0"20'-0"54'-10"25'-11"13'-0" 8'-4" FIRE HYDRANT STAGING AREA FOR PICK UP PEDESTRAIN RETAIL ENTRY 8'-4"8'-4"5'-0"7'-6"8'-0"18'-0"32'-0"27'-6"14'-8"104'-2"12'-2"27'-0"18'-0"7'-8"39'-6" 39'-6" ADA 1 2 4 5 6 7 EV 3 8 COMPACT COMPACT COMPACT STANDARDSTANDARD12'-0"3'-0"SETBACK15'-0"SITE DEDICATION11'-6 1/8"73'-0"15'-0"ADA 35'-1 1/2"4'-4 1/2" 1640 SF 1578 SF PEDESTRAIN RETAIL ENTRY 158'-6"88'-0"SETBACK 1'-2 1/8" 0'-6"0'-6 1/8"88'-0"EE45' R.O.W.CURB0'-6"PROPOSED 4" DDVC & FDC CONNECTION REFER TO CIVIL NEW FIRE HYDRANT 8'-8"7'-4"144' - 0"80' - 0"LOT COVERAGE AT GRADE CD ZONE 100 % LOT COVERAGE ALLOWED IN CD ZONE = 3,542.37 SF 91.7 % LOT COVERAGE PROVIDED IN CD ZONE = 3,251 SF LOT COVERAGE AT GRADE CA ZONE 65 % LOT COVERAGE ALLOWED IN CA ZONE CAN BE 75% WITH ONSITE PARKING GARAGE = 7970.33 SF 74.9 % LOT COVERAGE PROVIDED IN CA ZONE = 7962 SF REQUIRED : NONE OUTSIDE DOWNTOWN BUSINESS CENTER PROVIDED: NONE COMMERCIAL AREA REQUIREMENT CD ZONE REQUIRED : 40% OF GROUND FLOOR AREA = 3188 SF PROVIDED: 41.3 % = 3218 SF COMMERCIAL AREA REQUIREMENT CA ZONE COMMERCIAL TENANTS TO BE – ON SITE SERVICES TOTAL SITE AREA:0.75 ACRES = 16, 010 SF GROSS AREA : 53,035 SF (REFER TO SHEET A002 SHOWING AREA PLANS) LANDSCAPING :1580 TOTAL SF ;REFER TO LANDSCAPE PLANS FOR DETAILS ALL SIGNIFICANT TREES CAN BE RETAINED, AS VERIFIED BY ABORIST & LANDSCAPE ARCHITECT MAXIMUM BUILDING HEIGHT CD ZONE ALLOWED : 150' CAN BE MORE WITH CONDITIONAL USE PERMIT PROPOSED: 75'-0" MAXIMUM BUILDING HEIGHT CA ZONE ALLOWED : 70' - MIXED USE BUILDING PROPOSED : 65' = ELEV 99' FROM GRADE PLANE RMC 4-3-20 AIRPORT RELATED HEIGHT USE : AIRPORT SAFETY ZONE 5 & 6 ALLOWED ELEV 152' -172' FROM GRADE PLANE RMC 4-3-20 AIRPORT RELATED HEIGHT USE : AIRPORT SAFETY ZONE 5 & 6 ALLOWED ELEV 152' -172' FROM GRADE PLANE REQUIRED VEHICULAR PARKING (PER RMC 4-4-080 - E.10.e): CD ZONE REQUIRED : MIN. 1 STALL PER UNIT = 16 STALLS PROVIDED: 16 STALLS RESIDENTIAL PARKING REQUIREMENT CD ZONE COMMERCIAL PARKING REQUIREMENT CD ZONE REQUIRED : MIN. 1 STALL PER 1000 SF = NO COMMERCIAL REQUIRED FOR PROJECT PROVIDED: 0 STALL REQUIRED VEHICULAR PARKING (RMC 4-4-080 - E.10.e): CA ZONE REQUIRED : MIN. 1 STALL PER UNIT = 14 STALLS IN GARAGE PROVIDED: 14 STALLS IN STRUCTURED GARAGE RESIDENTIAL PARKING REQUIREMENT CA ZONE COMMERCIAL PARKING REQUIREMENT CA ZONE REQUIRED : MIN. 2.5 STALLS PER 1000 SF = 3218 X 2.5 /1000 = 8.05 PROVIDED: 8 STALLS SET BACK (PER RMC 4-2-120 B): CD ZONE SET BACK (PER RMC 4-2-120 A): CA ZONE FRONT YARD : NONE FOR BUILDING OVER 25' PROVIDED : NONE REAR SETBACK : NONE,UNLESS THE GROUND FLOOR FACADE PROVIDES WINDOWS FOR LIVING ROOMS OF ATTACHED DWELLINGS –THEN 10 FT. –UNLESS PROVIDED : REFER PLANS SIDE SETBACK : NONE,UNLESS THE GROUND FLOOR FACADE PROVIDES WINDOWS FOR LIVING ROOMS OF ATTACHED DWELLINGS –THEN 10 FT. –UNLESS PROVIDED : REFER PLANS FRONT SETBACK : 15 FT PROVIDED : 15' NORTH PL REAR SETBACK : NONE( UNLESS ABUTS A LOT ZONED TO RESIDENTIAL) PROVIDED: NONE SIDE SETBACK : NONE, EXCEPT 15 FT. IF LOT ABUTS PROVIDED: 1' 2" WEST PL OR IS ADJACENT TO A LOT ZONED RESIDENTIAL. UPPER STORY SETBACK NONE, UNLESS ADJACENT TO AND FACING A RESIDENTIALLY ZONED LOT OR IF THE FACADE CONTAINS LIVING ROOM WINDOWS –THEN 10 FT. FOR THE SECOND STORY AND 15 FT. FOR ALL UPPER STORIES. UNITS IN CD ZONE DO NOT HAVE A LIVING ROOM WINDOW ON THE EXTERIOR. REFER TO NARRATIVE PROVIDED TOTAL PARKING PROVIDED = RETAIL = 8 STALLS 4 COMPACT STALLS @ 7'- 6" X 13-0" 4 STANDARD STALLS @ 8'- 4" X 16'-0" TOTAL PARKING PROVIDED RESIDENTIAL UNITS = 30 STALLS 15 COMPACT STALLS @ 7'- 6" X 13-0" 15 STANDARD STALLS @ 8'- 4" X 16'-0" TOTAL PARKING STALLS PROVIDED FOR THE PROJECT 38 STALLS FOR DETAILED LAND USE COMPLIANCE INFORMATION REFER TO SHEET A 001 10655 NE 4th Street SUITE 707 Bellevue, WA 98004 T 425.401.6828 F 425.401.0630 www.VeerArchitecture.com 10/3/2023 12:13:54 PMA101 SITE PLAN 2022016DREAMLINER APARTMENTS09/27/2023 SITE PLAN DEVELOPMENT2022016 Author A101DREAMLINER LLC511 AIRPORT WAY , RENTON0'5'20'10'40' SCALE:1" = 10'-0"1 SITE PLAN - GRADE LEVEL 2 VICINITY MAP