Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutMFP23005025.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP23005025
IVR Number: 23005025
Permit Information
Permit Name: Century Link Permits - P.120039
Address/Location:10/03/2023Application Date:3340406260Parcel Number: 900 SW 16TH ST
Permit Type:10/26/2023Issue Date:Franchise
Permit Work Class:10/25/2024Expiration Date:Minor Utility
Job Number: P.120039Franchise Type:Telephone
Description: Century Link Access MH 129.
Contacts
Name Address PhoneTypeBilling
Nathan Macleod
Lumen
7850 S Trafton St, Bldg B
Tacoma, WA 98409
C: (253) 583-6283ApplicantX
Merilyn Luong
Lumen
H: (206) 806-7160Applicant
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Applicant
Stephen Neumann
Fibe Solutions
604 W Meeker St., Suite 103
KENT, WA 98032
C: (425) 753-1916Applicant
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Contact
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
P.120039 MFP23005025
Nathan Macleod (253) 393-5338
23315 66TH AVE S KENT WA 98032
9 am 5 pm
NorthSky Communications
900 SW 16th St
11/6/2023 11/9/2023
Access existing MH for splicing.
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 10/26/2023
Merilyn Luong
10/23/2023
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton Standards.
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
King
COVERSHEET
1:60
P.120039 98057
(1) All spacing may be adjusted to accommodate interchange ramps,
at-grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadwayconditions.
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS & URBAN ARTERIALS
RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH
45/55 MPH
35/40 MPH
25/30 MPH
25 MPH OR LESS
800'
SIGN SPACING=X (FEET) (1)
500'
350'
200'
100'(2)
(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD)
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200250 305 360425 495 570 645 730
MINIMUM TAPER LENGTH (L) IN FEET
Lane
Width
Feet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
Pedestrian Escort: Stop work, secure passable
ADA compliant Pedestrian access on existing
sidewalk (4' min.). Clear zone must be free of
overhead hazards when Pedestrians are moving
through the work area.
Cover Sheet
MHMH
Scope of Work: Existing Manhole Access
Plan Scale
1 : 600 (1'' = 50')
10/2/2023 by:
Elite Traffic Solutions206.922.9205
Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
Legend
MH Manhole
MH 129
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergencyvehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 36 x 36 B/O unless otherwise specified.
7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-grade
intersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
SW 16TH ST25MPH
LIND AVE SW25MPH
www.invarion.com
MFP23005025
Imagery and map data ©2023, Google
W4-119
W1-4L
ROAD
WORK
AHEAD
W20-1
CENTER LANECLOSED
AHEAD
W20-5
ROADWORKAHEAD
W20-1ROADWORKAHEAD
W20-1
ROADWORKAHEAD
W20-1XXL/2 L/2
27'
75'R
S
800 SW 16TH ST
SW 16TH ST25MPH
900 SW 16TH ST
807 SW 16TH ST
1101 SW 16TH ST
LIND AVE SW25MPH
LIND AVE SW25MPH
SW 16TH ST25MPH
DW
DW
DW
DW
DW
DW
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton Standards.
Traffic Control Planner
Elite Traffic Solutions
206-922-9205
julian@elitetrafficsolutions.com
Renton
King
1 1
1:60
P.120039 98057
1:50
Plan Scale
1 : 600 (1'' = 50')
SPEED
LIMIT
25
City of Renton
requires static custom
signs or PCMS boards
set 7 days in advance
of the road closure that
indicates days & time of
the closure.
Scope of Work: Existing Manhole Access
MINIMUM TAPER LENGTH (L) IN FEET
Lane
WidthFeet
Posted Speed (mph)
10
11
12
25 30 35 40 45 50 55 60 65 70
105
115
125
150
165
180
205
225
245
265
295
320
450
495
540
500
550
600
550
605
660
660
720 780 840
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
30
20
80
60
40
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
LENGTH (FEET)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570645 730
N
10/2/2023 by:Elite Traffic Solutions
206.922.9205Julian Morales
TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ
Legend
Cone
DW Driveway
MH Manhole
Sign StandS
Spotter
Work Area
Traffic Control Plan: Typical Lane Shift With Two Way Left Turn Lane
KEEP
RIGHT
R4-7bR3-2
R3-2 XXLBMHMH
MH 129
General Notes:
1. All signs and spacing shall conform to The MUTCD and WAC.
2. Priority passage through the work area for emergency
vehicles vehicles shall be provided at all times.
3. Alert Metro Transit 5 days in advance
4. Protective vehicle recommended may be a work vehicle.
5. Devices should not encroach into adjacent lanes.
6. All signs min. 36 x 36 B/O unless otherwise specified.7. Channelization devices are 28" reflective cones
8. All sign spacing may be adjusted to accommodate at-grade
intersections and/or driveways.
9. Traffic Control Supervisor required for ROW impacts.
www.invarion.comMFP23005025
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE: WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.00000000”NVICINITY MAPSL900 SW 16TH STREETRENTON, WA 98055P.120039W26226RNTNWA0123N4E2409/06/2331®CUSTOMER NAME: N/ALCON: N/APHONE #: N/AEMAIL: N/AWFMT #: N/AORDER #: N/AARMOR OR DSR #: N/ASCOPE OF WORK:POF: @ MANHOLE T-129, ACCESS ONLY.SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ROBIN POEPHONE NO: 253-458-6571EMAIL: robin.poe@lumen.comMFP23005025
TT
TTTEE
EEE CATV CATV CATV
CA
TV CATV CATV
CATV
CATV
GG
GGG TS TS TS
TS
TS
WWWWW S S
S S
S
SD SD SD
SD
SD
C/L C/L
C/
L C/L
C/L
C/
L
R/W R/W R/W
R/W
R/W
R/W
R/W P/L P/L P/L
P/L
P/L
P/L
B/C B/C B/C
B/C
B/C
B/C
B/C
B/
C EOP EOP
EOP
EOP
EOP
TTTUSAMEEPWREE CAT
V
CATV
TVTV CATV
CATV
CATV
CATV CATV
CATV
CATV
CATV VTS C/L
C/L VWSSDVETTTXXX'XXX'XXX'XXX'X IRRIG IRRIG F1TTTTTTNOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: RNGE:SECT:TOWN:GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:JOB:GEO CODE:WC CLLI:DRAFTED BY: MOUNTAIN LTD/SH OF SL900 SW 16TH STREETRENTON, WA 98055P.120039W26226RNTNWA0123N4E2409/06/2332®MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ROBIN POEPHONE NO: 253-458-6571EMAIL: robin.poe@lumen.comMFP23005025
NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP T800PARCEL#3340406430801PARCEL#3340405300SW 16th STREETSIDEWALKSIDEWALKPOF LMN MH T-12920'13'13'13'38'22'NOTE:POF: @ MANHOLE T-129, ACCESS ONLY.900SW 16th STREETPARCEL#33404062600NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSL900 SW 16TH STREETRENTON, WA 98055P.120039W26226RNTNWA0123N4E2409/06/2333RSH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ROBIN POEPHONE NO: 253-458-6571EMAIL: robin.poe@lumen.comMFP23005025