Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutEx_09_TIR
PRELIMINARY
TECHNICAL INFORMATION REPORT
Harmony Ridge
15509 116th Ave SE
Renton, Washington
Prepared for:
Ichijo USA Co., Ltd.
1406 140th PL NE, Suite 104
Bellevue, WA 98007
February 2, 2023
Our Job No. 22298
2/2/2023
RECEIVED
05/03/2023
AMorganroth
PLANNING DIVISION
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.002-DRNG
TABLE OF CONTENTS
1.0 PROJECT OVERVIEW
Figure 1.0.1 – Technical Information Report (TIR) Worksheet
Figure 1.0.2 – Vicinity Map
Figure 1.0.3 – Predeveloped Basin Map
Figure 1.0.4 – Soil Survey Map
Figure 1.0.5 – Assessor's Map
Figure 1.0.6 – FEMA Map
Figure 1.0.7 – Sensitive Area Map
Figure 1.0.8 – Developed Basin Map
Figure 1.0.9 – Downstream Basin Map
2.0 CONDITIONS AND REQUIREMENTS SUMMARY
2.1 Analysis of the Core Requirements and Special Requirements
3.0 OFF-SITE ANALYSIS
4.0 FLOW CONTROL AND WATER QUALITY FACILITY ANALYSIS AND DESIGN
4.1 Existing Site Hydrology
4.2 Developed Site Hydrology
4.3 Performance Standards
4.4 Flow Control System
Figure 4.4.1 – Detention Vault Calculations
4.5 Water Quality System
5.0 CONVEYANCE SYSTEM ANALYSIS AND DESIGN
6.0 SPECIAL REPORTS AND STUDIES
6.1 Geotechnical Engineering Study prepared by Earth Solutions NW, LLC. dated November 22,
2022
7.0 OTHER PERMITS
8.0 ESC ANALYSIS AND DESIGN
9.0 BOND QUANTITIES AND FACILITY SUMMARIES
10.0 OPERATIONS AND MAINTENANCE MANUAL
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 1.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
1.0 PROJECT OVERVIEW
This section contains the following information:
Figure 1.0.1 – Technical Information Report (TIR) Worksheet
Figure 1.0.2 – Vicinity Map
Figure 1.0.3 – Predeveloped Basin Map
Figure 1.0.4 – Soil Survey Map
Figure 1.0.5 – Assessor's Map
Figure 1.0.6 – FEMA Map
Figure 1.0.7 – Sensitive Area Map
Figure 1.0.8 – Developed Basin Map
Figure 1.0.9 – Downstream Basin Map
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
1.0 PROJECT OVERVIEW
The Harmony Ridge project is a single-family residential project consisting of the redevelopment of
an existing parcel in the City of Renton. The project includes approximately 6.2 acres of parcel area
located on 15509 116th Ave SE. The proposed development will construct 21 single-family lots with
associated roads, tracts, utilities, and stormwater facilities. The existing United Christian Church
(UCC) buildings located near the northeast corner of the site will remain with this development. The
project site is located within a portion of Section 20, Township 23 North, Range 5 East, Willamette
Meridian, in the City of Renton, Washington.
The property contains multiple buildings and a parking lot near the northeast corner of the site gaining
access from 116th Ave SE. Aside from these existing developed areas, the site mostly consists of
undisturbed forested area. There are no natural drainage courses of any kind on the property.
Elevations range from 465 to 420 feet across the site with slopes ranging from approximately 2 to
25%.
The USDA Web Soil Survey for this area shown in Figure 1.0.4 of this section indicates that the onsite
soils are considered Alderwood gravelly sandy loam and Alderwood material with 8 to 15 percent
slopes. This soil type is typically comprised of glacial soils. The Geotechnical Engineering Study
prepared by Earth Solutions NW, LLC identified the underlying native soil as glacial till deposits
between the depths of 0.5 to 14 feet. These soils are considered infeasible for infiltration facilities per
the Geotechnical Engineering Study included in Section 6.1 of this report.
Onsite construction will include a public roadway with curb and gutter, sidewalk and planter strip,
alley road for lot access and detention and water quality facilities. Additionally, stormwater catch
basins, storm pipes, water mains and sewer utilities will be constructed onsite. Frontage
improvements along 116th Ave SE will consist of roadway widening with vertical curb, planter strip
and sidewalk.
Stormwater runoff generated by the onsite impervious and pervious areas will be routed to an onsite
detention vault located within the Tract A and will be treated prior to discharging to the downstream
conveyance system on Puget Dr SE. Runoff eventually flows into Thunder Hills Creek to the
southwest. Water quality will be provided by a stormfilter located immediately downstream of the
proposed detention vault.
The storm drainage design is based on the 2022 City of Renton Surface Water Design Manual (2022
CORSWDM) which is an amended version of the 2021 King County Surface Water Design Manual
(2021 KCSWDM). Please refer to Section 4.0 of this TIR for further details regarding the drainage
facility design.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
CITY OF RENTON SURFACE WATER DESIGN MANUAL
2022 City of Renton Surface Water Design Manual 6/22/2022
8-A-1
REFERENCE 8-A
TECHNICAL INFORMATION REPORT (TIR)
WORKSHEET
Part 1 PROJECT OWNER AND
PROJECT ENGINEER Part 2 PROJECT LOCATION AND
DESCRIPTION
Project Owner _____________________________
Phone ___________________________________
Address __________________________________
_________________________________________
Project Engineer ___________________________
Company _________________________________
Phone ___________________________________
Project Name __________________________
CED Permit # ________________________
Location Township ________________
Range __________________
Section _________________
Site Address __________________________
_____________________________________
Part 3 TYPE OF PERMIT APPLICATION Part 4 OTHER REVIEWS AND PERMITS
Land Use (e.g., Subdivision / Short Subd.)
Building (e.g., M/F / Commercial / SFR)
Grading
Right-of-Way Use
Other _______________________
DFW HPA
COE 404
DOE Dam Safety
FEMA Floodplain
COE Wetlands
Other ________
Shoreline
Management
Structural
Rockery/Vault/_____
ESA Section 7
Part 5 PLAN AND REPORT INFORMATION
Technical Information Report Site Improvement Plan (Engr. Plans)
Type of Drainage Review
(check one):
Date (include revision
dates):
Date of Final:
Full
Targeted
Simplified
Large Project
Directed
__________________
__________________
__________________
Plan Type (check
one):
Date (include revision
dates):
Date of Final:
Full
Modified
Simplified
__________________
__________________
__________________
Ichijo USA Co., Ltd.
(425) 497-0616
1406 140th Pl NE, Suite 104
Bellevue WA 98007
Barry Talkington
Barghausen Consulting Engineers
(425) 251-6222
Harmony Ridge
23
05
20
15509 116th Ave SE
Renton WA, 98058
Keystone Wall
Figure 1.0.1DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
REFERENCE 8: PLAN REVIEW FORMS AND WORKSHEET
TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
6/22/2022 2022 City of Renton Surface Water Design Manual
8-A-2
Part 6 SWDM ADJUSTMENT APPROVALS
Type (circle one): Standard / Blanket
Description: (include conditions in TIR Section 2)
____________________________________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
Approved Adjustment No. ______________________ Date of Approval: _______________________
Part 7 MONITORING REQUIREMENTS
Monitoring Required: Yes / No
Start Date: _______________________
Completion Date: _______________________
Describe: _________________________________
_________________________________________
_________________________________________
Re: SWDM Adjustment No. ________________
Part 8 SITE COMMUNITY AND DRAINAGE BASIN
Community Plan: ____________________________________________________________________
Special District Overlays: ______________________________________________________________
Drainage Basin: _____________________________________________________________________
Stormwater Requirements: _____________________________________________________________
Part 9 ONSITE AND ADJACENT SENSITIVE AREAS
River/Stream ________________________
Lake ______________________________
Wetlands ____________________________
Closed Depression ____________________
Floodplain ___________________________
Other _______________________________
_______________________________
Steep Slope __________________________
Erosion Hazard _______________________
Landslide Hazard ______________________
Coal Mine Hazard ______________________
Seismic Hazard _______________________
Habitat Protection ______________________
_____________________________________
TBD
TBD
N/A
Black River Basin (Thunder Hills Creek Sub Basin), Lower Cedar River (Ginger Creek Sub Basin)
2022 City of Renton Surface Water Design Manual
ESC facilities including a temporary
sediment pond
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
REFERENCE 8-A: TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
2022 City of Renton Surface Water Design Manual 6/22/2022
Ref 8-A-3
Part 10 SOILS
Soil Type
______________________
______________________
______________________
______________________
Slopes
________________________
________________________
________________________
________________________
Erosion Potential
_________________________
_________________________
_________________________
_________________________
High Groundwater Table (within 5 feet)
Other ________________________________
Sole Source Aquifer
Seeps/Springs
Additional Sheets Attached
Part 11 DRAINAGE DESIGN LIMITATIONS
REFERENCE
Core 2 – Offsite Analysis_________________
Sensitive/Critical Areas__________________
SEPA________________________________
LID Infeasibility________________________
Other________________________________
_____________________________________
LIMITATION / SITE CONSTRAINT
_______________________________________
_______________________________________
_______________________________________
_______________________________________
_______________________________________
_______________________________________
Additional Sheets Attached
Part 12 TIR SUMMARY SHEET (provide one TIR Summary Sheet
per Threshold Discharge Area)
Threshold Discharge Area:
(name or description)
Core Requirements (all 9 apply):
Discharge at Natural Location Number of Natural Discharge Locations:
Offsite Analysis Level: 1 / 2 / 3 dated:__________________
Flow Control (include facility
summary sheet)
Standard: _______________________________
or Exemption Number: ____________
Conveyance System Spill containment located at: _____________________________
Erosion and Sediment Control /
Construction Stormwater Pollution
Prevention
CSWPP/CESCL/ESC Site Supervisor: _____________________
Contact Phone: _________________________
After Hours Phone: _________________________
Maintenance and Operation Responsibility (circle one): Private / Public
If Private, Maintenance Log Required: Yes / No
Financial Guarantees and Liability Provided: Yes / No
Alderwood gravelly
sandy loam
Alderwood material
8-15%Low
8-15%Low
Discharging to roadside ditch on Puget Dr SE
tributary to Thunder Hills Creek Sub Basin
1
12/01/2022
Flow Control Duration Standard Matching Forested Site Conditions
TBD
TBD
TBD
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
REFERENCE 8: PLAN REVIEW FORMS AND WORKSHEET
TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
6/22/2022 2022 City of Renton Surface Water Design Manual
8-A-4
Part 12 TIR SUMMARY SHEET (provide one TIR Summary Sheet
per Threshold Discharge Area)
Water Quality (include facility
summary sheet)
Type (circle one): Basic / Sens. Lake / Enhanced Basic / Bog
or Exemption No. _______________________
On-site BMPs Describe:
Special Requirements (as applicable):
Area Specific Drainage
Requirements
Type: SDO / MDP / BP / Shared Fac. / None
Name: ________________________
Floodplain/Floodway Delineation Type (circle one): Major / Minor / Exemption / None
100-year Base Flood Elevation (or range): _______________
Datum:
Flood Protection Facilities Describe:
Source Control
(commercial / industrial land use)
Describe land use:
Describe any structural controls:
Oil Control High-Use Site: Yes / No
Treatment BMP: _________________________________
Maintenance Agreement: Yes / No
with whom? _____________________________________
Other Drainage Structures
Describe:
Reduced Impervious Surface, Basic Sheet Flow Dispersion
N/A
N/A
N/A
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
REFERENCE 8-A: TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
2022 City of Renton Surface Water Design Manual 6/22/2022
Ref 8-A-3
Part 10 SOILS
Soil Type
______________________
______________________
______________________
______________________
Slopes
________________________
________________________
________________________
________________________
Erosion Potential
_________________________
_________________________
_________________________
_________________________
High Groundwater Table (within 5 feet)
Other ________________________________
Sole Source Aquifer
Seeps/Springs
Additional Sheets Attached
Part 11 DRAINAGE DESIGN LIMITATIONS
REFERENCE
Core 2 – Offsite Analysis_________________
Sensitive/Critical Areas__________________
SEPA________________________________
LID Infeasibility________________________
Other________________________________
_____________________________________
LIMITATION / SITE CONSTRAINT
_______________________________________
_______________________________________
_______________________________________
_______________________________________
_______________________________________
_______________________________________
Additional Sheets Attached
Part 12 TIR SUMMARY SHEET (provide one TIR Summary Sheet
per Threshold Discharge Area)
Threshold Discharge Area:
(name or description)
Core Requirements (all 9 apply):
Discharge at Natural Location Number of Natural Discharge Locations:
Offsite Analysis Level: 1 / 2 / 3 dated:__________________
Flow Control (include facility
summary sheet)
Standard: _______________________________
or Exemption Number: ____________
Conveyance System Spill containment located at: _____________________________
Erosion and Sediment Control /
Construction Stormwater Pollution
Prevention
CSWPP/CESCL/ESC Site Supervisor: _____________________
Contact Phone: _________________________
After Hours Phone: _________________________
Maintenance and Operation Responsibility (circle one): Private / Public
If Private, Maintenance Log Required: Yes / No
Financial Guarantees and Liability Provided: Yes / No
Discharging to catch basin on 116th Ave SE
tributary to Ginger Creek Sub Basin
1
12/01/2022
Flow Control Duration Standard Matching Forested Site Conditions
TBD
TBD
TBD
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
REFERENCE 8: PLAN REVIEW FORMS AND WORKSHEET
TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
6/22/2022 2022 City of Renton Surface Water Design Manual
8-A-4
Part 12 TIR SUMMARY SHEET (provide one TIR Summary Sheet
per Threshold Discharge Area)
Water Quality (include facility
summary sheet)
Type (circle one): Basic / Sens. Lake / Enhanced Basic / Bog
or Exemption No. _______________________
On-site BMPs Describe:
Special Requirements (as applicable):
Area Specific Drainage
Requirements
Type: SDO / MDP / BP / Shared Fac. / None
Name: ________________________
Floodplain/Floodway Delineation Type (circle one): Major / Minor / Exemption / None
100-year Base Flood Elevation (or range): _______________
Datum:
Flood Protection Facilities Describe:
Source Control
(commercial / industrial land use)
Describe land use:
Describe any structural controls:
Oil Control High-Use Site: Yes / No
Treatment BMP: _________________________________
Maintenance Agreement: Yes / No
with whom? _____________________________________
Other Drainage Structures
Describe:
N/A
N/A
N/A
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
REFERENCE 8-A: TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
2022 City of Renton Surface Water Design Manual 6/22/2022
Ref 8-A-5
Part 13 EROSION AND SEDIMENT CONTROL REQUIREMENTS
MINIMUM ESC REQUIREMENTS
DURING CONSTRUCTION
Clearing Limits
Cover Measures
Perimeter Protection
Traffic Area Stabilization
Sediment Retention
Surface Water Collection
Dewatering Control
Dust Control
Flow Control
Control Pollutants
Protect Existing and Proposed
BMPs/Facilities
Maintain Protective BMPs / Manage
Project
MINIMUM ESC REQUIREMENTS
AFTER CONSTRUCTION
Stabilize exposed surfaces
Remove and restore Temporary ESC Facilities
Clean and remove all silt and debris, ensure
operation of Permanent BMPs/Facilities, restore
operation of BMPs/Facilities as necessary
Flag limits of sensitive areas and open space
preservation areas
Other _______________________
Part 14 STORMWATER FACILITY DESCRIPTIONS (Note: Include Facility Summary and Sketch)
Flow Control Description Water Quality Description On-site BMPs Description
Detention
Infiltration
Regional
Facility
Shared
Facility
Other
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
Vegetated
Flowpath
Wetpool
Filtration
Oil Control
Spill Control
Other
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
Full Dispersion
Full Infiltration
Limited Infiltration
Rain Gardens
Bioretention
Permeable
Pavement
Basic Dispersion
Soil Amendment
Perforated Pipe
Connection
Other
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
Detention Vault
Stormfilter
Reduced
Impervious Surface
Roof Downspout
Connections
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
REFERENCE 8: PLAN REVIEW FORMS AND WORKSHEET
TECHNICAL INFORMATION REPORT (TIR) WORKSHEET
6/22/2022 2022 City of Renton Surface Water Design Manual
8-A-6
Part 15 EASEMENTS/TRACTS Part 16 STRUCTURAL ANALYSIS
Drainage Easement
Covenant
Native Growth Protection Covenant
Tract
Other ____________________________
Cast in Place Vault
Retaining Wall
Rockery > 4′ High
Structural on Steep Slope
Other _______________________________
Part 17 SIGNATURE OF PROFESSIONAL ENGINEER
I, or a civil engineer under my supervision, have visited the site. Actual site conditions as observed were
incorporated into this worksheet and the attached Technical Information Report. To the best of my
knowledge the information provided here is accurate.
____________________________________________________________________________________
Signed/Date
2/2/2023
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Horizontal:
Scale:
Vertical:
For:
Title:
V I C I N I T Y M A P
Job Number
N.T.S.N/A 22298
DATE: 11/14/22
Harmony Ridge
Renton, Washington
P:\22000s\22298\exhibit\graphics\22298 vmap.cdr
RE FER ENC E: MapQuest (2022)
SITE
Figure 1.0.2DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
For:Title:
22298
1
ICHIJO USA CO., LTD.
1406 140TH PL NE, SUITE 104
BELLEVUE, WA 98007 HARMONY RIDGECITY OF RENTON, KING COUNTY, WASHINGTONA PORTION OF SECTION 20, TOWNSHIP 23 N., RANGE 05 E., W.M.HARMONY RIDGE FORPREDEVELOPED BASIN MAPPREDEVELOPED BASIN MAP
FOR
1 SCALE: 1"=50'116TH AVE SESE 19TH STSE 19TH STPREDEVELOPEDBASIN 1PREDEVELOPED BASIN 1PREDEVELOPED BASIN 2PREDEVELOPEDBASIN 1PREDEVELOPEDBASIN 1PREDEVELOPEDBASIN 2Figure 1.0.3DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Horizontal:
Scale:
Vertical:
For:
Title:
S O I L S U RV E Y M A P
Job Number
N.T.S.N/A 22298
DATE: 11/14/22
Harmony Ridge
Renton, Washington
P:\22000s\22298\exhibit\graphics\22298 soil.cdr
HS G
B
B/D
RE FER ENCE: US DA, Natural Resources Conservation Service
LE GEN D:
SITE
AgC = Alderwood gravelly sandy loam, 8-15% slopes
AmC = Arents, Alderwood material, 6-15% slopes
Figure 1.0.4DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Horizontal:
Scale:
Vertical:
For:
Title:
A S S E S S O R M A P
Job Number
N.T.S.N/A 22298
DATE: 11/14/22
Harmony Ridge
Renton, Washington
P:\22000s\22298\exhibit\graphics\22298 amap.cdr
SITE
RE FER ENC E: King County Department of Assessments (July 2022)
Figure 1.0.5DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Horizontal:
Scale:
Vertical:
For:
Title:
F E M A M A P
Job Number
N.T.S.N/A 22298
DATE: 11/14/22
Harmony Ridge
Renton, Washington
P:\22000s\22298\exhibit\graphics\22298 fema.cdr
REFER EN CE: Federal Emergency Management Agency (Portion of Map 53033C0979G, Aug. 2020)
SITE
L E GEND
Areas determined to be outside the 0.2% annual chance floodplain.ZONE X
OTHER AREAS
Figure 1.0.6
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Horizontal:
Scale:
Vertical:
For:
Title:
S E N S I T I V E A R E A S
M A P
Job Number
N.T.S.N/A 22298
DATE: 11/14/22
Harmony Ridge
Renton, Washington
P:\22000s\22298\exhibit\graphics\22298 sens.cdr
SITE
RE FER ENC E: King County iM AP (2022)
Figure 1.0.7DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
NO PARKINGNO PARKING FIRE LANE12345678910111218171615141320211922For:Title:
22298
1
ICHIJO USA CO., LTD.
1406 140TH PL NE, SUITE 104
BELLEVUE, WA 98007 HARMONY RIDGECITY OF RENTON, KING COUNTY, WASHINGTONA PORTION OF SECTION 20, TOWNSHIP 23 N., RANGE 05 E., W.M.HARMONY RIDGE FORDEVELOPED BASIN MAPDEVELOPED BASIN MAP
FOR
1 SCALE: 1"=50'116TH AVE SESE 19TH STSE 19TH STDEVELOPED BASIN 1DEVELOPED BASIN 2TRACT ATRACT BTRACT DDETENTIONVAULTROAD AROAD B
DEVELOPEDBASIN 1DEVELOPEDBASIN 2PUGET DR SE DEVELOPEDBASIN 1DEVELOPEDBASIN 1TRACT CFigure 1.0.8DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
SDSD
SD
SD
SDSD
SD SD
SDSDSDSDSDSDFor:Title:
22298
1
ICHIJO USA CO., LTD.
1406 140TH PL NE, SUITE 104
BELLEVUE, WA 98007 HARMONY RIDGECITY OF RENTON, KING COUNTY, WASHINGTONA PORTION OF SECTION 20, TOWNSHIP 23 N., RANGE 05 E., W.M.HARMONY RIDGE FORDOWNSTREAM BASIN MAPDOWNSTREAM BASIN MAP
FOR
1 SCALE: 1"=100'DEVELOPEDBASIN 2FLOWPATH LEGENDSDSPECIAL NOTE1/4 MILE DOWNSTREAMFROM SITESE 157TH ST116TH AVE SESE 19TH STPUGET DR SEABERDEEN AVE SE
C
AM
A
S
C
T
S
E
ROLLING HILLS AVE SESE 18TH CTSE 17TH CTSE 18TH PLRO
Y
A
L
H
I
L
S
D
R
S
E
116TH AVE SE
SE
1
6
TH
S
T
FERNDALE AVE SEDEVELOPEDBASIN 11/4 MILE DOWNSTREAMFROM SITETHUNDER HILLSCREEKSE 19TH STDEVELOPEDBASIN 1Figure 1.0.9DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 2.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
2.0 CONDITIONS AND REQUIREMENTS SUMMARY
This section contains the following information:
2.1 Analysis of the Core Requirements and Special Requirements
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
2.1 Analysis of the Core Requirements and Special Requirements
CORE REQUIREMENTS HOW PROJECT HAS ADDRESSED REQUIREMENT
No. 1: Discharge at Natural
Location
The majority of stormwater runoff from the site sheetflows in a
southwest manner and eventually enters the existing conveyance
system within the Rolling Hills Village plat to the southwest. From
there, runoff flows west for approximately 550 feet and enters the
conveyance system on Puget Dr SE and eventually flows into
Thunder Hills Creek. A smaller portion of the site consisting of
the existing church buildings, parking lot and frontage
improvements on the north side of the site flows to the northeast
and is tributary to the Ginger Creek sub basin.
In the developed site, runoff tributary to Thunder Hills Creek will
be conveyed to the west and discharged into the existing
conveyance system on Puget Dr SE, thus maintaining the existing
natural discharge location of the site. Runoff tributary to the
Ginger Creek sub basin as discussed above will continue to be
collected by the existing conveyance system on 116th Ave SE and
discharging to the Ginger Creek sub basin. Please refer to the
Predeveloped and Developed Basin Maps in this Section 1.0 and
the Developed Site Hydrology in Section 4.0 for further detail.
No. 2: Off-Site Analysis The off-site analysis has been included within Section 3.0 of this
Technical Information Report.
No. 3: Flow Control Runoff from all target surfaces in the developed site is designed
to be collected and detained per Flow Control Duration Standard
Matching Forested Site Conditions.
No. 4: Conveyance System The conveyance system will be designed per the 2022 City of
Renton Surface Water Design Manual and will be included in
Section 5.0 of the Technical Information Report at final
engineering.
No. 5: Erosion and Sediment
Control
Temporary erosion control measures for this project will include:
stabilized construction entrances, perimeter runoff control, cover
practices, sedimentation facilities, and construction sequencing.
No. 6: Maintenance and
Operations
An Operations and Maintenance Manual, if required, will be
provided at final engineering.
No. 7: Bonds and Liability Bonding will be completed as required by the City of Renton at
final engineering.
No. 8: Water Quality Basic Water Quality will be provided using a Stormfilter system.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
No. 9: Flow Control BMPs According to the Geotechnical Engineering Study in Section 6.1,
the underlying glacial till soil found onsite is not considered
feasible for infiltration facilities. Because of this, the following
BMP’s are infeasible for the lots and roads: Full Infiltration, Limited
Infiltration, Bioretention and Permeable Pavement. Full
Dispersion cannot be applied as a native vegetated flowpath
cannot be provided due to site constraints. As such, the Reduced
Impervious Surface Credit BMP and the Basic Sheet Flow
Dispersion BMP will be applied where feasible for each lot to meet
the 2022 CORSWDM requirements. Further detail on the
application of these BMP’s for each lot will be addressed during
final engineering. Finally, roof downspout connections to the
permanent storm conveyance system will be done with perforated
pipe connections. All pervious surfaces will incorporate soil
amendment as detailed in the 2022 CORSWDM.
SPECIAL REQUIREMENTS HOW PROJECT HAS ADDRESSED REQUIREMENT
No. 1: Other Adopted Area
Specific Requirements
This special requirement does not apply to this project.
No. 2: Floodplain/Floodway
Delineation
The proposed development is not located within the 100-year
floodplain.
No. 3: Flood Protection
Facilities
This project does not rely on an existing flood protection facility
nor propose to modify or construct a new flood protection facility,
therefore this special requirement does not apply.
No. 4: Source Controls This project is a single-family residential project and is not subject
to this special requirement.
No. 5: Oil Control This site is not classified as a high-use site given the criteria found
in the 2022 City of Renton Surface Water Design Manual,
therefore no special oil control treatment is necessary.
No. 6: Aquifer Protection Area This site is not located within an aquifer protection area.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 3.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
3.0 OFF-SITE ANALYSIS
This section contains the following information:
Task 1 – Study Area Definitions and Maps
Task 2 – Resource Review
Task 3 – Field Inspection
3.1 Conveyance System Nuisance Problems (Type 1)
3.2 Severe Erosion Problems (Type 2)
3.3 Severe Flooding Problems (Type 3)
3.4 Downstream Water Quality Problems
Task 4 – Drainage System Description and Problem Descriptions
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
TASK 1 – STUDY AREA DEFINITION AND MAPS
The Harmony Ridge project consists of the development of 21 single-family lots in a 6.2 acre site.
The site is located at 15509 116th Ave SE, Renton, WA 98058 in a portion of Section 20, Township
23 North, Range 5 East, Willamette Meridian, in the City of Renton, Washington.
The site is adjacent to existing single-family residences to the south and forested land to the west.
Runoff tributary to the single-family residences to the south is routed to a closed conveyance system
that is downstream of the project site, therefore no upstream runoff is expected from those
developments. The general topography of the forested area to the west of the site slopes in a
southwest manner, therefore no upstream runoff is expected from this area. This site is also bordered
by 116th Ave SE to the east, which conveys runoff to the northeast through an existing conveyance
system.
The project proposes to collect and detain stormwater which originates onsite. Following detention,
stormwater runoff will receive water quality treatment by a Stormfilter System which will be routed to
the existing conveyance system on Puget Dr SE. Runoff eventually discharges to Thunder Hills Creek
to the southwest of the project site.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
TASK 2 – RESOURCE REVIEW
· Adopted Basin Plans: The site is tributary to the Thunder Hills Creek sub basin and the Ginger
Creek sub basin. There are no known basin plans which impact the proposed project.
· Finalized Drainage Studies: There are no finalized drainage studies found within one mile of the
downstream of the project site.
· Basin Reconnaissance Summary Report: This is not applicable.
· Floodplain and Floodway FEMA Maps: The project site is not located in a floodplain area, therefore
this is not applicable.
· Other Off-Site Analysis Reports: A site investigation was conducted as a Level 1 Off-Site Drainage
Analysis.
· Critical and Sensitive Area maps: Based on a review of King County iMap, the site is located within
a Moderate Coal Mine Hazard Area. According to the Geotechnical Engineering Study included in
Section 6.0 of this report, no buffers or setbacks should be applied to the project with respect to
the coal mine hazard area and the development is not expected to increase the potential for ground
subsidence on the project site.
· Sensitive Area maps from City of Renton were also reviewed. According to the City of Renton Map,
the site is not located within a Wellhead Protection Area and is located within an Erosion Hazard
Area. The Geotechnical Engineering Study in Section 6.0 of this report states that this site
possesses low erosion hazard potential. Typical best management practices and landscaping will
mitigate any potential of soil erosion during and after construction.
· United States Department of Agriculture Web Soil Survey: Based on the Soils Map (Figure 1.0.4)
for this area, the site is located on Alderwood gravelly sandy loam and Alderwood material. This
soils type is confirmed by the Geotechnical Engineering Study prepared for the project.
· Wetland Inventory Map: The City of Renton Map does not show any wetlands within or adjacent
to the project site.
· Drainage Complaints along both downstream paths from the site were reviewed on the King County
iMap. There were no complaints found within one mile downstream of the project site. In addition,
no flooding issues were observed in the area during the downstream analysis. Because of this, the
proposed development will not impact the downstream system.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
TASK 3 – FIELD INSPECTION
Level 1 Off-Site Drainage Analysis:
The field reconnaissance for the Level 1 Off-Site Drainage Analysis was conducted on December 1,
2022. On the day of the visit, conditions were partly cloudy. Several days of rainfall had occurred
prior to the site visit with snowfall occurring the day before. As mentioned earlier in this report, runoff
from the existing site discharges to two drainage basins, the Thunder Hills Creek sub basin and
Ginger Creek sub basin. In the developed condition, most of the stormwater runoff tributary to this
development will be collected and routed to a single onsite detention vault which discharges runoff
to the Thunder Hills Creek sub basin. Although not disturbed with this project, a UCC building was
included in the Predeveloped and Developed Basin 1 areas because rooftop runoff from this building
discharges to the onsite forested area and sheetflows to the southwest. This runoff will be collected
and routed to the onsite detention vault in the developed condition.
Runoff tributary to the northern portion of the frontage improvements required for this development
will not be routed to the onsite detention vault. This runoff is tributary to the Ginger Creek sub basin
in the existing conditions and will continue to discharge to that basin in the developed conditions.
Please refer to the Predeveloped Basin Map (Figure 1.0.3) and the Developed Basin Map (Figure
1.0.8) for further detail regarding the existing and developed drainage basins.
Developed Basin 1 (Discharges to the Thunder Hills Creek Sub Basin)
The majority of onsite runoff in the existing and developed conditions will flow to the Thunder Hills
Creek sub basin. Runoff from the proposed detention vault will be conveyed westward by a new
closed conveyance system through the adjacent property before reaching Puget Dr SE. Runoff will
flow in a southwest manner along Puget Dr SE through a new closed conveyance system for
approximately 420 feet before connecting to the existing roadside conveyance system at the
intersection of Puget Dr SE and SE 19th St. A series of photos were taken during the site visit
describing the conditions of the existing conveyance system along the downstream flowpath. The
locations of each of these photos are shown in the Downstream Basin Map (Figure 1.0.9) included
in this report.
Photo #1 – Looking Southwest Photo #2 – Looking Southwest
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
Photo #1 shows the existing culvert inlet of the roadside ditch on the east side of Puget Dr SE
approximately 30 feet northeast of the Puget Dr SE and SE 19th St intersection. Existing runoff along
Puget Dr SE flows southwest along the roadside ditch and enters the culvert inlet at this location.
Photo #2 shows the existing catch basin on the northeast side of the intersection. After entering the
culvert shown on Photo #1, runoff flows southwest and enters the catch basin shown on Photo #2.
The new conveyance system routing runoff along Puget Dr SE will connect to the existing conveyance
system by installing a new catch basin along the culvert that outlets to the catch basin shown in Photo
#2. The connection point location is shown on the Developed Basin Map (Figure 1.0.8) and the
Downstream Basin Map (Figure 1.0.9).
Photo #3 – Looking Southwest Photo #4 – Looking Northeast
After entering the catch basin shown in Photo #2, runoff continues to flow southwest across the SE
19th St intersection and outlets to the roadside ditch on the east side of Puget Dr SE shown in Photo
#3. From there, runoff continues to flow southwest along the roadside ditch for approximately 330
feet until reaching the end of the ditch at the low point of Puget Dr SE. At the low point location, runoff
is conveyed northeast through a culvert and outlets to a roadside ditch on the west side of Puget Dr
SE. The location of the culvert inlet is shown in Photo #4.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
Photo #5 – Looking Southwest Photo #6 – Looking West
Once entering the Puget Dr SE west roadside ditch, runoff flows southwest for approximately 100
feet through a culvert and discharges to another section of the ditch shown in Photo #5. After entering
this ditch, runoff continues to flow southwest and enters the manhole shown in Photo #6 through
another culvert approximately 40 feet downstream.
Photo #7 – Looking West Photo #8 – Looking South
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
Once entering the manhole shown in Photo #6, runoff begins to flow west across the neighboring
property through an existing drainage easement. After approximately 190 feet of flow, runoff outlets
to the manhole shown in Photo #7. From there, runoff continues to flow west for approximately 100
feet and outlets into Thunder Hills Creek. Photo #8 above shows the 24-inch outlet culvert into
Thunder Hills Creek.
Photo #9 – Looking West
After entering Thunder Hills Creek, runoff will flow for approximately 130 feet before reaching one-
quarter mile downstream. After this point, runoff will continue to flow southwest along the path of
Thunder Hills Creek as shown in Photo #9.
Developed Basin 2 (Discharges to the Ginger Creek Sub Basin)
A small portion of runoff tributary to a portion of the frontage improvements required along 116th Ave
SE will continue to flow north along this road in the developed condition. This area is located on the
northeast side of the site and is delineated as Developed Basin 2 in the Developed Basin Map (Figure
1.0.8). A series of photos were taken during the site visit describing the conditions of the existing
conveyance system along the downstream flowpath. The locations of each of these photos are shown
in the Downstream Basin Map (Figure 1.0.9) included in this report.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
Photo #1 – Looking North Photo #2 – Looking Southeast
Photo #1 above shows the existing catch basin located on the west side of 116th Ave SE near the
northeast corner of the site. In the developed condition, runoff tributary to the frontage improvements
in that area will continue to flow north and enter the catch basin shown in Photo #1. Once entering
this catch basin, runoff will continue to flow north for approximately 350 feet before entering the catch
basin shown in Photo #2 above at the intersection of 116th Ave SE and Puget Dr SE.
Photo #3 – Looking Northeast Photo #4 – Looking Northeast
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
After entering the catch basin shown in Photo #2, runoff begins to flow southeast for approximately
130 feet before discharging to the manhole shown in Photo #3 within Ginger Creek Park. From there,
runoff flows northeast for approximately 90 feet and connects to the existing storm main running
southeast through a tee. Runoff begins to flow southeast for approximately 120 feet before entering
the manhole on SE 16th St shown in Photo #4.
Photo #5 – Looking Northeast Photo #6 – Looking Northeast
Once entering the manhole shown in Photo #4, runoff begins to flow northeast along SE 16th St.
Runoff continues to flow in this direction for approximately 320 feet before discharging into the
manhole shown in Photo #5. After another 310 feet of flowpath to the northeast runoff reaches one-
quarter downstream just before discharging into the manhole shown in Photo #6.
3.1 Conveyance System Nuisance Problems (Type 1)
Conveyance system nuisance problems are minor but not chronic flooding or erosion problems that
result from the overflow of a constructed conveyance system that is substandard or has become too
small as a result of upstream development. Such problems warrant additional attention because of
their chronic nature and because they result from the failure of a conveyance system to provide a
minimum acceptable level of protection. There were no conveyance system nuisance problems
observed during the December 1, 2022 site visit.
3.2 Severe Erosion Problems (Type 2)
Severe erosion problems can be caused by conveyance system overflows or the concentration of
runoff into erosion-sensitive open drainage features. Severe erosion problems warrant additional
attention because they pose a significant threat either to health and safety, or to public or private
property. Runoff within one-quarter mile downstream of the project site is not discharged into any
erosion-sensitive open drainage features. In addition, there were no conveyance system overflows
observed during the December 1, 2022 site visit. Because of this, no future erosion problems should
occur downstream.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
3.3 Severe Flooding Problems (Type 3)
Severe flooding problems can be caused by conveyance system overflows or the elevated water
surfaces of ponds, lakes, wetlands, or closed depressions. Severe flooding problems are defined as
follows:
· Flooding of the finished area of a habitable building for runoff events less than or equal to
the 100-year event. Examples include flooding of finished floors of homes and commercial or
industrial buildings. Flooding in electrical/heating systems and components in the crawlspace or
garage of a home. Such problems are referred to as "severe building flooding problems."
· Flooding over all lanes of a roadway or severely impacting a sole access driveway for runoff
events less than or equal to the 100-year event. Such problems are referred to as "severe
roadway flooding problems."
Based on a review of the FEMA Map (Section 1.0) the proposed site is not located in any
floodplain areas therefore no severe flooding problems are expected.
3.4 Downstream Water Quality Problems
After reviewing the Washington State Department of Ecology Water Quality Atlas, there are no
Category 5, 4 or 2 Waterbodies located within one-quarter mile downstream of the project site
therefore no water quality problems are expected from this development.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
TASK 4 – DRAINAGE SYSTEM DESCRIPTION AND PROBLEM DESCRIPTIONS
UPSTREAM DRAINAGE ANALYSIS
The site is adjacent to existing single-family residences to the south and forested land to the west.
Runoff tributary to the single-family residences to the south is routed to a closed conveyance system
that is downstream of the project site, therefore no upstream runoff is expected from those
developments. The general topography of the forested area to the west of the site slopes in a
southwest manner, therefore no upstream runoff is expected from this area. This site is also bordered
by 116th Ave SE to the east, which conveys runoff to the northeast through an existing conveyance
system.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 4.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
4.0 FLOW CONTROL AND WATER QUALITY FACILITY ANALYSIS AND DESIGN
This section contains the following information:
4.1 Existing Site Hydrology
4.2 Developed Site Hydrology
4.3 Performance Standards
4.4 Flow Control System
4.5 Water Quality System
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
4.1 Existing Site Hydrology
The existing conditions of the project site consist of four existing buildings and a parking lot gaining
access from 116th Ave SE along the east boundary line. Aside from these existing developed areas,
the site mostly consists of undisturbed forested area. There are no natural drainage courses of any
kind on the property. Elevations range from 465 to 420 feet across the site with slopes ranging from
approximately 2 to 25%. The Geotechnical Engineering Study prepared by Earth Solutions NW, LLC
identified the underlying native soil as glacial till deposits between the depths of 0.5 to 14 feet. These
soils are considered infeasible for infiltration facilities per the Geotechnical Engineering Study
included in Section 6.1 of this report.
The majority of stormwater runoff from the existing site (5.29 acres) flows in a southwest manner and
enters the existing conveyance system within the Rolling Hills Village Plat to the southwest. This area
was delineated as Predeveloped Basin 1 in the Predeveloped Basin Map included in Section 1.0 of
this report. Although not disturbed with this development, an existing UCC building was included in
the Predeveloped Basin 1 area because rooftop runoff from this building discharges to the forested
area onsite and sheetflows to the southwest. Once entering the existing conveyance system within
the Rolling Hills Village Plat, runoff flows west for approximately 550 feet before entering the
conveyance system on Puget Dr SE. Runoff continues to flow southwest and eventually discharges
to Thunder Hills Creek.
A smaller portion of the existing site flows towards 116th Ave SE and is tributary to the Ginger Creek
sub basin to the northeast. This area is approximately 1.2 acres in size and consists of three UCC
buildings and a parking lot. The parking lot was confirmed to flow towards 116th Ave SE due to the
relative elevations of the parking lot shown in the topographic survey. Based on the invert elevations
of the adjacent yard drains and a field reconnaissance conducted on January 18th, it can be
reasonably assumed that rooftop runoff from the three UCC buildings near the northeast corner of
the site flows to a nearby onsite yard drain and connects to the existing conveyance system on 116th
Ave SE. The majority of this area of the site will not be disturbed with this development. The only
disturbance to this area consists of the frontage improvements along 116th Ave SE that will be
constructed with this development on the north side of the site. This frontage improvement area is
0.16 acres in size and is delineated as Predeveloped Basin 2 in the Predeveloped Basin Map in
Section 1.0 of this report. Please refer to this map for further detail on the predeveloped basin areas.
Per the requirement of the 2022 CORSWDM, all predeveloped basin areas were modeled as forested
till soil.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
4.2 Developed Site Hydrology
When completed, the Harmony Ridge project will create 21 new single-family residences. The project
development will consist of access roads, planter strips, sidewalks, driveways, utilities and a
detention vault. As shown in the Developed Basin Map, the site will consist of two basins in the
developed condition: Developed Basins 1 and 2.
Developed Basin 1
Developed Basin 1 is tributary to the Thunder Hills Creek sub basin and consists of all onsite
impervious and pervious areas including access roads, sidewalks, driveways, lot areas and lawn
areas. This basin will also include the frontage improvements on 116th Ave SE to the south of the
entrance of the site. A conveyance system consisting of catch basins and storm pipes will be
constructed to collect and route stormwater runoff from the target surfaces to the onsite detention
vault. This conveyance system will also connect to the existing outlet of the UCC church building near
Lot 21 and route its rooftop runoff to the onsite detention vault. This is done to maintain the existing
discharge location of rooftop runoff tributary to the building. As previously stated, infiltration is not
feasible for this site due to the presence of glacial till soils. Because of this, all lots will provide
perforated stub-out connections that will be tightlined to the proposed stormwater conveyance
system.
A breakdown of the impervious and pervious areas in the Developed Basin is shown in the table
below. A more detailed breakdown is shown in the Developed Basin Map included as Figure 1.0.8 in
this report.
Developed Basin
Impervious
Roads
Impervious
Bypass Road
Existing UCC
building
Impervious
Lots
Pervious
Lawn
Tree Protection
Tracts
Total
Area
1.36 Ac(1) 0.09 Ac(2) 0.07 Ac 1.63 Ac(3) 1.40 Ac(4) 0.74 Ac(5) 5.29 Ac
Notes:
1. Consists of 100% impervious right-of-way area, alley roads, and vault access road
2. Offsite Sewer manhole access roads
3. 65% maximum impervious coverage per lot. See Section 4.3 for further detail
4. Modeled as till grass
5. Modeled as forested
Developed Basin 2
As shown in the Developed Basin Map (Figure 1.0.8), a portion of the runoff tributary to the frontage
improvements required along 116th Ave SE on the north side of the site entrance (0.16 acres in size)
will not be routed to the onsite vault because it is tributary to the Ginger Creek sub basin. It should
be noted that although the three UCC buildings and parking lot in this area of the site also discharge
to the Ginger Creek sub basin, they were not included in the Developed Basin 2 area because they
will not be disturbed with this development. Please refer to Sections 4.4 and 4.5 for further detail on
the flow control and water quality calculations for this basin.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
4.3 Performance Standards
This project is subject to Core Requirement #9 of the 2022 CORSWDM requiring the application of
onsite BMP’s to mitigate stormwater runoff. A feasibility table has been provided below discussing
the evaluation of each BMP found in the 2022 CORSWDM.
In addition, the 2017 CORSWDM states that the assumed impervious coverage for each lot shall
not be less than 4,000 square feet per lot or the maximum impervious coverage permitted per Table
3.2.2.C, whichever is less. The largest lot size proposed for this project is 5,935 SF which results
in a maximum impervious surface of 3,857 for the site. This means that the maximum lot impervious
surface coverage of 65% will be used for sizing the onsite detention vault.
The WWHM program was used to size the detention vault for this project. The flow control
requirement for this project is the Flow Control Duration Standard Matching Forested Site
Conditions. Please refer to the WWHM calculations located in Section 4.4 of this report for further
detail. This project is also required to provide Basic Water Quality and will do so via a Stormfilter
System. Please refer to Section 4.5 for further detail.
Core Requirement #9 – Onsite BMP Evaluation
Full Dispersion Not feasible for this site due to lot constrains
Full infiltration Not feasible due to onsite native soil being glacial till. See Geotechnical
Engineering Study in Section 6.0 for further detail.
Limited
Infiltration
Not feasible due to onsite native soil being glacial till. See Geotechnical
Engineering Study in Section 6.0 for further detail.
Basic
Dispersion
May be feasible for portions of driveways and walks depending on the
specific site plan for each lot. Feasibility of this BMP will be verified during
the building permit stage.
Farmland
Dispersion
Not applicable.
Bioretention Not feasible due to onsite native soil being glacial till. See Geotechnical
Engineering Study in Section 6.0 for further detail.
Permeable
Pavement
Not feasible due to onsite native soil being glacial till. See Geotechnical
Engineering Study in Section 6.0 for further detail.
Rainwater
Harvesting
Feasible but impractical, evaluated on an individual lot basis at developer’s
discretion.
Reduced
Impervious
Surface Credit
Will be applied as required on each lot. Further detail will be provided during
final engineering.
Native Growth
Retention Credit
Not feasible due to site constrains.
Perforated Pipe
Connection
All lots will provide perforated stub out connections when tight lined to the
proposed stormwater conveyance system.
Rain Gardens Not feasible for this site due to limitation caused by landscape requirements
and utility placement.
Soil Amendment The soil amendment BMP will be applied to all disturbed pervious surfaces.
Tree Retention
Credit
Not feasible due to site constrains.
Vegetated Roofs All roofs are pitch roofs and are unsuitable for this BMP implication.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
4.4 Flow Control System
Developed Basin 1
The onsite detention vault was sized per the Flow Control Duration Standard Matching Forested Site
Conditions based on the 2022 CORSWDM. This standard requires that discharges are designed to
match developed discharge durations to predeveloped durations (historical) for the range of 50
percent of the 2-year peak flow up to the 50-year peak flow. This standard also requires that the 2-
year and 10-year predeveloped (historical) peak flows be matched in the developed condition. After
sizing the detention vault for these standards, the volume required for the vault is 62,552 cubic feet.
The volume provided for the detention pond is 64,045 cubic feet. Please see the WWHM calculations
provided in this section for further detail.
Developed Basin 2
As noted earlier, there is approximately 0.16 acres of runoff from the frontage improvements on 116th
Ave SE to the north of the site entrance that will not be routed to the onsite detention vault. This runoff
is tributary to the Ginger Creek sub basin and has a separate threshold discharge area from
Developed Basin 1. According to Section 1.2.3.1B of the 2022 CORSWDM, the facility requirement
in Flow Control Duration Standard Matching Forested Site Conditions is waived for any threshold
discharge area in which there is no more than a 0.15 cfs difference in the sum of developed 100-year
peak flows for those target surfaces and the sum of historical site conditions 100-year peak flows for
the same surfaces. As shown in Figure 4.4.2, the difference in the 100-year peak flows between the
historical site conditions and developed site conditions does not exceed 0.15 cfs, therefore a flow
control facility is not required for this basin.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
WWHM2012
PROJECT REPORT
Figure 4.4.1
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:11 PM Page 2
General Model Information
Project Name:Detention Vault
Site Name:
Site Address:
City:
Report Date:2/1/2023
Gage:Seatac
Data Start:1948/10/01
Data End:2009/09/30
Timestep:15 Minute
Precip Scale:1.000
Version Date:2019/09/13
Version:4.2.17
POC Thresholds
Low Flow Threshold for POC1:50 Percent of the 2 Year
High Flow Threshold for POC1:50 Year
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:11 PM Page 3
Landuse Basin Data
Predeveloped Land Use
Basin 1
Bypass:No
GroundWater:No
Pervious Land Use acre
C, Forest, Flat 3.36
C, Forest, Mod 1.93
Pervious Total 5.29
Impervious Land Use acre
Impervious Total 0
Basin Total 5.29
Element Flows To:
Surface Interflow Groundwater
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:11 PM Page 4
Mitigated Land Use
Basin 1
Bypass:No
GroundWater:No
Pervious Land Use acre
C, Lawn, Flat 1.4
C, Forest, Flat 0.74
Pervious Total 2.14
Impervious Land Use acre
ROADS FLAT 1.36
ROOF TOPS FLAT 1.7
Impervious Total 3.06
Basin Total 5.2
Element Flows To:
Surface Interflow Groundwater
Vault 1 Vault 1
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:11 PM Page 5
Bypass Basin 1
Bypass:Yes
GroundWater:No
Pervious Land Use acre
Pervious Total 0
Impervious Land Use acre
ROADS FLAT 0.09
Impervious Total 0.09
Basin Total 0.09
Element Flows To:
Surface Interflow Groundwater
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:11 PM Page 7
Mitigated Routing
Vault 1
Width:64 ft.
Length:64 ft.
Depth:15.8 ft.
Discharge Structure
Riser Height:15.3 ft.
Riser Diameter:18 in.
Orifice 1 Diameter:1 in.Elevation:0 ft.
Orifice 2 Diameter:1.32 in.Elevation:8.5 ft.
Orifice 3 Diameter:1.5 in.Elevation:12 ft.
Element Flows To:
Outlet 1 Outlet 2
Vault Hydraulic Table
Stage(feet)Area(ac.)Volume(ac-ft.)Discharge(cfs)Infilt(cfs)
0.0000 0.094 0.000 0.000 0.000
0.1756 0.094 0.016 0.011 0.000
0.3511 0.094 0.033 0.016 0.000
0.5267 0.094 0.049 0.019 0.000
0.7022 0.094 0.066 0.022 0.000
0.8778 0.094 0.082 0.025 0.000
1.0533 0.094 0.099 0.027 0.000
1.2289 0.094 0.115 0.030 0.000
1.4044 0.094 0.132 0.032 0.000
1.5800 0.094 0.148 0.034 0.000
1.7556 0.094 0.165 0.036 0.000
1.9311 0.094 0.181 0.037 0.000
2.1067 0.094 0.198 0.039 0.000
2.2822 0.094 0.214 0.041 0.000
2.4578 0.094 0.231 0.042 0.000
2.6333 0.094 0.247 0.044 0.000
2.8089 0.094 0.264 0.045 0.000
2.9844 0.094 0.280 0.046 0.000
3.1600 0.094 0.297 0.048 0.000
3.3356 0.094 0.313 0.049 0.000
3.5111 0.094 0.330 0.050 0.000
3.6867 0.094 0.346 0.052 0.000
3.8622 0.094 0.363 0.053 0.000
4.0378 0.094 0.379 0.054 0.000
4.2133 0.094 0.396 0.055 0.000
4.3889 0.094 0.412 0.056 0.000
4.5644 0.094 0.429 0.058 0.000
4.7400 0.094 0.445 0.059 0.000
4.9156 0.094 0.462 0.060 0.000
5.0911 0.094 0.478 0.061 0.000
5.2667 0.094 0.495 0.062 0.000
5.4422 0.094 0.511 0.063 0.000
5.6178 0.094 0.528 0.064 0.000
5.7933 0.094 0.544 0.065 0.000
5.9689 0.094 0.561 0.066 0.000
6.1444 0.094 0.577 0.067 0.000
6.3200 0.094 0.594 0.068 0.000
6.4956 0.094 0.610 0.069 0.000
Volume Required: 62,552 CF
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:11 PM Page 8
6.6711 0.094 0.627 0.070 0.000
6.8467 0.094 0.643 0.071 0.000
7.0222 0.094 0.660 0.071 0.000
7.1978 0.094 0.676 0.072 0.000
7.3733 0.094 0.693 0.073 0.000
7.5489 0.094 0.709 0.074 0.000
7.7244 0.094 0.726 0.075 0.000
7.9000 0.094 0.742 0.076 0.000
8.0756 0.094 0.759 0.077 0.000
8.2511 0.094 0.775 0.077 0.000
8.4267 0.094 0.792 0.078 0.000
8.6022 0.094 0.808 0.094 0.000
8.7778 0.094 0.825 0.105 0.000
8.9533 0.094 0.841 0.113 0.000
9.1289 0.094 0.858 0.119 0.000
9.3044 0.094 0.874 0.125 0.000
9.4800 0.094 0.891 0.130 0.000
9.6556 0.094 0.907 0.135 0.000
9.8311 0.094 0.924 0.139 0.000
10.007 0.094 0.940 0.143 0.000
10.182 0.094 0.957 0.147 0.000
10.358 0.094 0.974 0.151 0.000
10.533 0.094 0.990 0.155 0.000
10.709 0.094 1.007 0.159 0.000
10.884 0.094 1.023 0.162 0.000
11.060 0.094 1.040 0.165 0.000
11.236 0.094 1.056 0.169 0.000
11.411 0.094 1.073 0.172 0.000
11.587 0.094 1.089 0.175 0.000
11.762 0.094 1.106 0.178 0.000
11.938 0.094 1.122 0.181 0.000
12.113 0.094 1.139 0.204 0.000
12.289 0.094 1.155 0.220 0.000
12.464 0.094 1.172 0.231 0.000
12.640 0.094 1.188 0.241 0.000
12.816 0.094 1.205 0.250 0.000
12.991 0.094 1.221 0.258 0.000
13.167 0.094 1.238 0.266 0.000
13.342 0.094 1.254 0.273 0.000
13.518 0.094 1.271 0.280 0.000
13.693 0.094 1.287 0.287 0.000
13.869 0.094 1.304 0.294 0.000
14.044 0.094 1.320 0.300 0.000
14.220 0.094 1.337 0.306 0.000
14.396 0.094 1.353 0.312 0.000
14.571 0.094 1.370 0.318 0.000
14.747 0.094 1.386 0.323 0.000
14.922 0.094 1.403 0.329 0.000
15.098 0.094 1.419 0.334 0.000
15.273 0.094 1.436 0.339 0.000
15.449 0.094 1.452 1.253 0.000
15.624 0.094 1.469 3.130 0.000
15.800 0.094 1.485 4.993 0.000
15.976 0.094 1.426 6.152 0.000
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:11 PM Page 9
Analysis Results
POC 1
+ Predeveloped x Mitigated
Predeveloped Landuse Totals for POC #1
Total Pervious Area:5.29
Total Impervious Area:0
Mitigated Landuse Totals for POC #1
Total Pervious Area:2.14
Total Impervious Area:3.15
Flow Frequency Method:Log Pearson Type III 17B
Flow Frequency Return Periods for Predeveloped. POC #1
Return Period Flow(cfs)
2 year 0.154691
5 year 0.249196
10 year 0.307422
25 year 0.374071
50 year 0.418569
100 year 0.458886
Flow Frequency Return Periods for Mitigated. POC #1
Return Period Flow(cfs)
2 year 0.114226
5 year 0.173507
10 year 0.221899
25 year 0.294743
50 year 0.358375
100 year 0.430804
Annual Peaks
Annual Peaks for Predeveloped and Mitigated. POC #1
Year Predeveloped Mitigated
1949 0.162 0.090
1950 0.200 0.129
1951 0.343 0.303
1952 0.108 0.072
1953 0.087 0.086
1954 0.134 0.083
1955 0.214 0.086
1956 0.171 0.159
1957 0.137 0.094
1958 0.155 0.105
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:51 PM Page 10
1959 0.133 0.084
1960 0.234 0.241
1961 0.131 0.124
1962 0.081 0.065
1963 0.112 0.086
1964 0.151 0.092
1965 0.105 0.145
1966 0.101 0.083
1967 0.223 0.101
1968 0.132 0.086
1969 0.129 0.084
1970 0.106 0.082
1971 0.116 0.098
1972 0.257 0.191
1973 0.116 0.141
1974 0.127 0.098
1975 0.173 0.097
1976 0.123 0.083
1977 0.016 0.082
1978 0.108 0.121
1979 0.065 0.071
1980 0.266 0.226
1981 0.097 0.087
1982 0.191 0.199
1983 0.168 0.087
1984 0.103 0.077
1985 0.061 0.080
1986 0.270 0.151
1987 0.238 0.191
1988 0.094 0.081
1989 0.061 0.077
1990 0.525 0.259
1991 0.301 0.218
1992 0.119 0.121
1993 0.121 0.071
1994 0.041 0.066
1995 0.173 0.128
1996 0.377 0.300
1997 0.306 0.286
1998 0.071 0.087
1999 0.305 0.193
2000 0.120 0.106
2001 0.022 0.084
2002 0.132 0.151
2003 0.183 0.086
2004 0.219 0.286
2005 0.159 0.090
2006 0.184 0.150
2007 0.390 0.352
2008 0.495 0.292
2009 0.238 0.162
Ranked Annual Peaks
Ranked Annual Peaks for Predeveloped and Mitigated. POC #1
Rank Predeveloped Mitigated
1 0.5248 0.3521
2 0.4949 0.3031
3 0.3904 0.2998
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:51 PM Page 11
4 0.3772 0.2919
5 0.3431 0.2864
6 0.3060 0.2858
7 0.3048 0.2588
8 0.3010 0.2406
9 0.2697 0.2259
10 0.2657 0.2177
11 0.2573 0.1987
12 0.2384 0.1934
13 0.2382 0.1913
14 0.2337 0.1907
15 0.2226 0.1622
16 0.2193 0.1595
17 0.2137 0.1511
18 0.1995 0.1509
19 0.1908 0.1499
20 0.1845 0.1454
21 0.1826 0.1408
22 0.1734 0.1287
23 0.1729 0.1280
24 0.1710 0.1243
25 0.1681 0.1215
26 0.1617 0.1208
27 0.1593 0.1065
28 0.1546 0.1054
29 0.1510 0.1013
30 0.1372 0.0980
31 0.1340 0.0978
32 0.1326 0.0966
33 0.1319 0.0937
34 0.1317 0.0921
35 0.1306 0.0899
36 0.1290 0.0899
37 0.1267 0.0872
38 0.1232 0.0868
39 0.1206 0.0865
40 0.1202 0.0865
41 0.1186 0.0864
42 0.1158 0.0864
43 0.1157 0.0863
44 0.1116 0.0857
45 0.1080 0.0842
46 0.1079 0.0841
47 0.1064 0.0837
48 0.1052 0.0834
49 0.1028 0.0832
50 0.1011 0.0826
51 0.0966 0.0823
52 0.0941 0.0816
53 0.0873 0.0805
54 0.0813 0.0799
55 0.0713 0.0772
56 0.0653 0.0769
57 0.0614 0.0718
58 0.0610 0.0715
59 0.0405 0.0705
60 0.0216 0.0664
61 0.0161 0.0654
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:51 PM Page 13
Duration Flows
The Facility PASSED
Flow(cfs)Predev Mit Percentage Pass/Fail
0.0773 17935 17040 95 Pass
0.0808 16506 12211 73 Pass
0.0842 14919 10692 71 Pass
0.0877 13836 10029 72 Pass
0.0911 12478 9456 75 Pass
0.0946 11516 9137 79 Pass
0.0980 10414 8645 83 Pass
0.1015 9666 8301 85 Pass
0.1049 9007 8012 88 Pass
0.1084 8224 7593 92 Pass
0.1118 7670 7238 94 Pass
0.1153 6979 6770 97 Pass
0.1187 6511 6436 98 Pass
0.1222 5978 5976 99 Pass
0.1256 5634 5653 100 Pass
0.1290 5191 5168 99 Pass
0.1325 4883 4864 99 Pass
0.1359 4605 4588 99 Pass
0.1394 4259 4205 98 Pass
0.1428 4021 3910 97 Pass
0.1463 3705 3553 95 Pass
0.1497 3493 3320 95 Pass
0.1532 3215 2988 92 Pass
0.1566 3037 2791 91 Pass
0.1601 2802 2535 90 Pass
0.1635 2627 2344 89 Pass
0.1670 2470 2169 87 Pass
0.1704 2278 1932 84 Pass
0.1739 2147 1781 82 Pass
0.1773 1972 1525 77 Pass
0.1807 1854 1347 72 Pass
0.1842 1725 1178 68 Pass
0.1876 1626 1111 68 Pass
0.1911 1485 1044 70 Pass
0.1945 1382 1005 72 Pass
0.1980 1295 979 75 Pass
0.2014 1203 950 78 Pass
0.2049 1137 924 81 Pass
0.2083 1069 889 83 Pass
0.2118 1017 858 84 Pass
0.2152 944 810 85 Pass
0.2187 893 773 86 Pass
0.2221 828 732 88 Pass
0.2256 781 697 89 Pass
0.2290 731 665 90 Pass
0.2324 699 640 91 Pass
0.2359 653 615 94 Pass
0.2393 609 581 95 Pass
0.2428 581 552 95 Pass
0.2462 543 515 94 Pass
0.2497 500 493 98 Pass
0.2531 468 459 98 Pass
0.2566 428 435 101 Pass
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:57:51 PM Page 14
0.2600 383 386 100 Pass
0.2635 360 368 102 Pass
0.2669 341 345 101 Pass
0.2704 302 301 99 Pass
0.2738 281 278 98 Pass
0.2773 252 242 96 Pass
0.2807 233 216 92 Pass
0.2841 209 180 86 Pass
0.2876 192 155 80 Pass
0.2910 164 127 77 Pass
0.2945 148 112 75 Pass
0.2979 135 101 74 Pass
0.3014 121 84 69 Pass
0.3048 111 71 63 Pass
0.3083 96 65 67 Pass
0.3117 89 62 69 Pass
0.3152 78 57 73 Pass
0.3186 72 54 75 Pass
0.3221 66 48 72 Pass
0.3255 58 45 77 Pass
0.3290 50 42 84 Pass
0.3324 42 39 92 Pass
0.3358 38 37 97 Pass
0.3393 31 27 87 Pass
0.3427 25 20 80 Pass
0.3462 21 11 52 Pass
0.3496 20 2 10 Pass
0.3531 19 0 0 Pass
0.3565 17 0 0 Pass
0.3600 14 0 0 Pass
0.3634 12 0 0 Pass
0.3669 10 0 0 Pass
0.3703 6 0 0 Pass
0.3738 6 0 0 Pass
0.3772 6 0 0 Pass
0.3807 5 0 0 Pass
0.3841 5 0 0 Pass
0.3875 5 0 0 Pass
0.3910 4 0 0 Pass
0.3944 3 0 0 Pass
0.3979 3 0 0 Pass
0.4013 3 0 0 Pass
0.4048 3 0 0 Pass
0.4082 3 0 0 Pass
0.4117 3 0 0 Pass
0.4151 3 0 0 Pass
0.4186 3 0 0 Pass
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:35 PM Page 17
Model Default Modifications
Total of 0 changes have been made.
PERLND Changes
No PERLND changes have been made.
IMPLND Changes
No IMPLND changes have been made.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:35 PM Page 18
Appendix
Predeveloped Schematic
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:39 PM Page 19
Mitigated Schematic
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 20
Predeveloped UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 Detention Vault.wdm
MESSU 25 PreDetention Vault.MES
27 PreDetention Vault.L61
28 PreDetention Vault.L62
30 POCDetention Vault1.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
PERLND 10
PERLND 11
COPY 501
DISPLY 1
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Basin 1 MAX 1 2 30 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
10 C, Forest, Flat 1 1 1 1 27 0
11 C, Forest, Mod 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
10 0 0 1 0 0 0 0 0 0 0 0 0
11 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 21
10 0 0 4 0 0 0 0 0 0 0 0 0 1 9
11 0 0 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
10 0 0 0 0 0 0 0 0 0 0 0
11 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
10 0 4.5 0.08 400 0.05 0.5 0.996
11 0 4.5 0.08 400 0.1 0.5 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
10 0 0 2 2 0 0 0
11 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
10 0.2 0.5 0.35 6 0.5 0.7
11 0.2 0.5 0.35 6 0.5 0.7
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
10 0 0 0 0 2.5 1 0
11 0 0 0 0 2.5 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
END GEN-INFO
*** Section IWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
END ACTIVITY
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
END PRINT-INFO
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
# - # CSNO RTOP VRS VNN RTLI ***
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
END IWAT-PARM2
IWAT-PARM3
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 22
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
END IWAT-STATE1
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
Basin 1***
PERLND 10 3.36 COPY 501 12
PERLND 10 3.36 COPY 501 13
PERLND 11 1.93 COPY 501 12
PERLND 11 1.93 COPY 501 13
******Routing******
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
in out ***
END GEN-INFO
*** Section RCHRES***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
END HYDR-PARM2
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
END HYDR-INIT
END RCHRES
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 23
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
END FTABLES
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 501 FLOW ENGL REPL
END EXT TARGETS
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
END MASS-LINK
END RUN
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 24
Mitigated UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 Detention Vault.wdm
MESSU 25 MitDetention Vault.MES
27 MitDetention Vault.L61
28 MitDetention Vault.L62
30 POCDetention Vault1.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
PERLND 16
PERLND 10
IMPLND 1
IMPLND 4
RCHRES 1
COPY 1
COPY 501
COPY 601
DISPLY 1
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Vault 1 MAX 1 2 30 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
601 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
16 C, Lawn, Flat 1 1 1 1 27 0
10 C, Forest, Flat 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
16 0 0 1 0 0 0 0 0 0 0 0 0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 25
10 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
16 0 0 4 0 0 0 0 0 0 0 0 0 1 9
10 0 0 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
16 0 0 0 0 0 0 0 0 0 0 0
10 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
16 0 4.5 0.03 400 0.05 0.5 0.996
10 0 4.5 0.08 400 0.05 0.5 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
16 0 0 2 2 0 0 0
10 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
16 0.1 0.25 0.25 6 0.5 0.25
10 0.2 0.5 0.35 6 0.5 0.7
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
16 0 0 0 0 2.5 1 0
10 0 0 0 0 2.5 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
1 ROADS/FLAT 1 1 1 27 0
4 ROOF TOPS/FLAT 1 1 1 27 0
END GEN-INFO
*** Section IWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
1 0 0 1 0 0 0
4 0 0 1 0 0 0
END ACTIVITY
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
1 0 0 4 0 0 0 1 9
4 0 0 4 0 0 0 1 9
END PRINT-INFO
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 26
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
# - # CSNO RTOP VRS VNN RTLI ***
1 0 0 0 0 0
4 0 0 0 0 0
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
1 400 0.01 0.1 0.1
4 400 0.01 0.1 0.1
END IWAT-PARM2
IWAT-PARM3
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
1 0 0
4 0 0
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
1 0 0
4 0 0
END IWAT-STATE1
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
Basin 1***
PERLND 16 1.4 RCHRES 1 2
PERLND 16 1.4 RCHRES 1 3
PERLND 10 0.74 RCHRES 1 2
PERLND 10 0.74 RCHRES 1 3
IMPLND 1 1.36 RCHRES 1 5
IMPLND 4 1.7 RCHRES 1 5
Basin 2***
IMPLND 1 0.09 COPY 501 15
IMPLND 1 0.09 COPY 601 15
******Routing******
PERLND 16 1.4 COPY 1 12
PERLND 10 0.74 COPY 1 12
IMPLND 1 1.36 COPY 1 15
IMPLND 4 1.7 COPY 1 15
PERLND 16 1.4 COPY 1 13
PERLND 10 0.74 COPY 1 13
RCHRES 1 1 COPY 501 16
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 27
in out ***
1 Vault 1 1 1 1 1 28 0 1
END GEN-INFO
*** Section RCHRES***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
1 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
1 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
1 0 1 0 0 4 0 0 0 0 0 0 0 0 0 2 2 2 2 2
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
1 1 0.01 0.0 0.0 0.5 0.0
END HYDR-PARM2
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
1 0 4.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
END HYDR-INIT
END RCHRES
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
FTABLE 1
91 4
Depth Area Volume Outflow1 Velocity Travel Time***
(ft) (acres) (acre-ft) (cfs) (ft/sec) (Minutes)***
0.000000 0.094031 0.000000 0.000000
0.175556 0.094031 0.016508 0.011370
0.351111 0.094031 0.033015 0.016080
0.526667 0.094031 0.049523 0.019694
0.702222 0.094031 0.066031 0.022740
0.877778 0.094031 0.082539 0.025424
1.053333 0.094031 0.099046 0.027851
1.228889 0.094031 0.115554 0.030083
1.404444 0.094031 0.132062 0.032160
1.580000 0.094031 0.148569 0.034110
1.755556 0.094031 0.165077 0.035956
1.931111 0.094031 0.181585 0.037711
2.106667 0.094031 0.198092 0.039387
2.282222 0.094031 0.214600 0.040996
2.457778 0.094031 0.231108 0.042543
2.633333 0.094031 0.247616 0.044036
2.808889 0.094031 0.264123 0.045481
2.984444 0.094031 0.280631 0.046880
3.160000 0.094031 0.297139 0.048239
3.335556 0.094031 0.313646 0.049561
3.511111 0.094031 0.330154 0.050849
3.686667 0.094031 0.346662 0.052105
3.862222 0.094031 0.363169 0.053331
4.037778 0.094031 0.379677 0.054529
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 28
4.213333 0.094031 0.396185 0.055702
4.388889 0.094031 0.412693 0.056851
4.564444 0.094031 0.429200 0.057977
4.740000 0.094031 0.445708 0.059081
4.915556 0.094031 0.462216 0.060165
5.091111 0.094031 0.478723 0.061230
5.266667 0.094031 0.495231 0.062277
5.442222 0.094031 0.511739 0.063306
5.617778 0.094031 0.528247 0.064319
5.793333 0.094031 0.544754 0.065317
5.968889 0.094031 0.561262 0.066299
6.144444 0.094031 0.577770 0.067267
6.320000 0.094031 0.594277 0.068221
6.495556 0.094031 0.610785 0.069162
6.671111 0.094031 0.627293 0.070090
6.846667 0.094031 0.643800 0.071007
7.022222 0.094031 0.660308 0.071911
7.197778 0.094031 0.676816 0.072804
7.373333 0.094031 0.693324 0.073687
7.548889 0.094031 0.709831 0.074559
7.724444 0.094031 0.726339 0.075421
7.900000 0.094031 0.742847 0.076273
8.075556 0.094031 0.759354 0.077116
8.251111 0.094031 0.775862 0.077950
8.426667 0.094031 0.792370 0.078775
8.602222 0.094031 0.808877 0.094708
8.777778 0.094031 0.825385 0.105319
8.953333 0.094031 0.841893 0.113035
9.128889 0.094031 0.858401 0.119488
9.304444 0.094031 0.874908 0.125185
9.480000 0.094031 0.891416 0.130361
9.655556 0.094031 0.907924 0.135151
9.831111 0.094031 0.924431 0.139639
10.00667 0.094031 0.940939 0.143881
10.18222 0.094031 0.957447 0.147919
10.35778 0.094031 0.973954 0.151783
10.53333 0.094031 0.990462 0.155496
10.70889 0.094031 1.006970 0.159077
10.88444 0.094031 1.023478 0.162542
11.06000 0.094031 1.039985 0.165901
11.23556 0.094031 1.056493 0.169165
11.41111 0.094031 1.073001 0.172343
11.58667 0.094031 1.089508 0.175443
11.76222 0.094031 1.106016 0.178470
11.93778 0.094031 1.122524 0.181430
12.11333 0.094031 1.139032 0.204882
12.28889 0.094031 1.155539 0.219984
12.46444 0.094031 1.172047 0.231563
12.64000 0.094031 1.188555 0.241532
12.81556 0.094031 1.205062 0.250512
12.99111 0.094031 1.221570 0.258799
13.16667 0.094031 1.238078 0.266562
13.34222 0.094031 1.254585 0.273908
13.51778 0.094031 1.271093 0.280911
13.69333 0.094031 1.287601 0.287625
13.86889 0.094031 1.304109 0.294090
14.04444 0.094031 1.320616 0.300337
14.22000 0.094031 1.337124 0.306390
14.39556 0.094031 1.353632 0.312271
14.57111 0.094031 1.370139 0.317995
14.74667 0.094031 1.386647 0.323577
14.92222 0.094031 1.403155 0.329028
15.09778 0.094031 1.419662 0.334359
15.27333 0.094031 1.436170 0.339579
15.44889 0.094031 1.452678 1.253684
15.62444 0.094031 1.469186 3.130535
15.80000 0.094031 1.485693 4.993734
END FTABLE 1
END FTABLES
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 29
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
RCHRES 1 HYDR RO 1 1 1 WDM 1000 FLOW ENGL REPL
RCHRES 1 HYDR STAGE 1 1 1 WDM 1001 STAG ENGL REPL
COPY 1 OUTPUT MEAN 1 1 48.4 WDM 701 FLOW ENGL REPL
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 801 FLOW ENGL REPL
COPY 601 OUTPUT MEAN 1 1 48.4 WDM 901 FLOW ENGL REPL
END EXT TARGETS
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 2
PERLND PWATER SURO 0.083333 RCHRES INFLOW IVOL
END MASS-LINK 2
MASS-LINK 3
PERLND PWATER IFWO 0.083333 RCHRES INFLOW IVOL
END MASS-LINK 3
MASS-LINK 5
IMPLND IWATER SURO 0.083333 RCHRES INFLOW IVOL
END MASS-LINK 5
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
MASS-LINK 15
IMPLND IWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 15
MASS-LINK 16
RCHRES ROFLOW COPY INPUT MEAN
END MASS-LINK 16
END MASS-LINK
END RUN
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Detention Vault 2/1/2023 3:58:41 PM Page 32
Disclaimer
Legal Notice
This program and accompanying documentation are provided 'as-is' without warranty of any kind. The
entire risk regarding the performance and results of this program is assumed by End User. Clear
Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either
expressed or implied, including but not limited to implied warranties of program and accompanying
documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever
(including without limitation to damages for loss of business profits, loss of business information,
business interruption, and the like) arising out of the use of, or inability to use this program even
if Clear Creek Solutions Inc. or their authorized representatives have been advised of the
possibility of such damages. Software Copyright © by : Clear Creek Solutions, Inc. 2005-2023; All
Rights Reserved.
Clear Creek Solutions, Inc.
6200 Capitol Blvd. Ste F
Olympia, WA. 98501
Toll Free 1(866)943-0304
Local (360)943-0304
www.clearcreeksolutions.com
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
WWHM2012
PROJECT REPORT
Figure 4.4.2
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:13:51 AM Page 2
General Model Information
Project Name:Basin 2
Site Name:
Site Address:
City:
Report Date:12/15/2022
Gage:Seatac
Data Start:1948/10/01
Data End:2009/09/30
Timestep:15 Minute
Precip Scale:1.000
Version Date:2019/09/13
Version:4.2.17
POC Thresholds
Low Flow Threshold for POC1:50 Percent of the 2 Year
High Flow Threshold for POC1:50 Year
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:13:51 AM Page 3
Landuse Basin Data
Predeveloped Land Use
Basin 2
Bypass:No
GroundWater:No
Pervious Land Use acre
C, Forest, Flat 0.16
Pervious Total 0.16
Impervious Land Use acre
Impervious Total 0
Basin Total 0.16
Element Flows To:
Surface Interflow Groundwater
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:13:51 AM Page 4
Mitigated Land Use
Basin 2
Bypass:No
GroundWater:No
Pervious Land Use acre
C, Lawn, Flat 0.07
Pervious Total 0.07
Impervious Land Use acre
ROADS FLAT 0.04
SIDEWALKS FLAT 0.05
Impervious Total 0.09
Basin Total 0.16
Element Flows To:
Surface Interflow Groundwater
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:13:51 AM Page 7
Analysis Results
POC 1
+ Predeveloped x Mitigated
Predeveloped Landuse Totals for POC #1
Total Pervious Area:0.16
Total Impervious Area:0
Mitigated Landuse Totals for POC #1
Total Pervious Area:0.07
Total Impervious Area:0.09
Flow Frequency Method:Log Pearson Type III 17B
Flow Frequency Return Periods for Predeveloped. POC #1
Return Period Flow(cfs)
2 year 0.004704
5 year 0.007388
10 year 0.008909
25 year 0.01052
50 year 0.011518
100 year 0.012366
Flow Frequency Return Periods for Mitigated. POC #1
Return Period Flow(cfs)
2 year 0.038924
5 year 0.051168
10 year 0.059746
25 year 0.071145
50 year 0.080055
100 year 0.089335
Annual Peaks
Annual Peaks for Predeveloped and Mitigated. POC #1
Year Predeveloped Mitigated
1949 0.005 0.055
1950 0.006 0.050
1951 0.010 0.034
1952 0.003 0.025
1953 0.003 0.028
1954 0.004 0.032
1955 0.006 0.035
1956 0.005 0.035
1957 0.004 0.042
1958 0.005 0.031
100-year peak flow not
increased by more than
0.15 cfs.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:14:29 AM Page 8
1959 0.004 0.029
1960 0.007 0.035
1961 0.004 0.035
1962 0.002 0.028
1963 0.003 0.034
1964 0.004 0.031
1965 0.003 0.044
1966 0.003 0.027
1967 0.006 0.050
1968 0.004 0.054
1969 0.004 0.040
1970 0.003 0.036
1971 0.003 0.043
1972 0.008 0.051
1973 0.004 0.024
1974 0.004 0.041
1975 0.005 0.043
1976 0.004 0.032
1977 0.000 0.030
1978 0.003 0.038
1979 0.002 0.050
1980 0.007 0.058
1981 0.003 0.040
1982 0.006 0.061
1983 0.005 0.044
1984 0.003 0.029
1985 0.002 0.040
1986 0.008 0.034
1987 0.007 0.050
1988 0.003 0.029
1989 0.002 0.036
1990 0.015 0.087
1991 0.009 0.065
1992 0.004 0.029
1993 0.004 0.024
1994 0.001 0.024
1995 0.005 0.035
1996 0.011 0.042
1997 0.009 0.040
1998 0.002 0.036
1999 0.009 0.082
2000 0.004 0.039
2001 0.001 0.039
2002 0.004 0.054
2003 0.005 0.042
2004 0.007 0.076
2005 0.005 0.035
2006 0.006 0.032
2007 0.011 0.078
2008 0.014 0.064
2009 0.007 0.045
Ranked Annual Peaks
Ranked Annual Peaks for Predeveloped and Mitigated. POC #1
Rank Predeveloped Mitigated
1 0.0151 0.0875
2 0.0144 0.0821
3 0.0112 0.0785
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:14:29 AM Page 9
4 0.0110 0.0757
5 0.0104 0.0653
6 0.0092 0.0641
7 0.0091 0.0605
8 0.0086 0.0578
9 0.0082 0.0546
10 0.0077 0.0540
11 0.0073 0.0537
12 0.0072 0.0506
13 0.0071 0.0502
14 0.0070 0.0502
15 0.0066 0.0501
16 0.0065 0.0498
17 0.0064 0.0445
18 0.0058 0.0440
19 0.0056 0.0437
20 0.0056 0.0434
21 0.0052 0.0426
22 0.0052 0.0423
23 0.0051 0.0420
24 0.0051 0.0420
25 0.0050 0.0410
26 0.0047 0.0401
27 0.0047 0.0399
28 0.0046 0.0399
29 0.0044 0.0397
30 0.0042 0.0390
31 0.0041 0.0386
32 0.0040 0.0377
33 0.0040 0.0363
34 0.0040 0.0363
35 0.0040 0.0356
36 0.0039 0.0353
37 0.0038 0.0351
38 0.0037 0.0349
39 0.0036 0.0349
40 0.0036 0.0348
41 0.0035 0.0346
42 0.0035 0.0343
43 0.0034 0.0340
44 0.0034 0.0339
45 0.0033 0.0318
46 0.0033 0.0317
47 0.0032 0.0317
48 0.0032 0.0313
49 0.0031 0.0310
50 0.0031 0.0301
51 0.0029 0.0292
52 0.0028 0.0291
53 0.0026 0.0290
54 0.0025 0.0290
55 0.0021 0.0278
56 0.0020 0.0275
57 0.0019 0.0268
58 0.0018 0.0255
59 0.0012 0.0242
60 0.0007 0.0239
61 0.0004 0.0238
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:14:56 AM Page 15
Model Default Modifications
Total of 0 changes have been made.
PERLND Changes
No PERLND changes have been made.
IMPLND Changes
No IMPLND changes have been made.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:14:56 AM Page 16
Appendix
Predeveloped Schematic
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:14:59 AM Page 17
Mitigated Schematic
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 18
Predeveloped UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 Basin 2.wdm
MESSU 25 PreBasin 2.MES
27 PreBasin 2.L61
28 PreBasin 2.L62
30 POCBasin 21.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
PERLND 10
COPY 501
DISPLY 1
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Basin 2 MAX 1 2 30 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
10 C, Forest, Flat 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
10 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
10 0 0 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 19
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
10 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
10 0 4.5 0.08 400 0.05 0.5 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
10 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
10 0.2 0.5 0.35 6 0.5 0.7
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
10 0 0 0 0 2.5 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
END GEN-INFO
*** Section IWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
END ACTIVITY
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
END PRINT-INFO
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
# - # CSNO RTOP VRS VNN RTLI ***
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
END IWAT-PARM2
IWAT-PARM3
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
END IWAT-STATE1
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 20
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
Basin 2***
PERLND 10 0.16 COPY 501 12
PERLND 10 0.16 COPY 501 13
******Routing******
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
in out ***
END GEN-INFO
*** Section RCHRES***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
END HYDR-PARM2
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
END HYDR-INIT
END RCHRES
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
END FTABLES
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 21
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 501 FLOW ENGL REPL
END EXT TARGETS
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
END MASS-LINK
END RUN
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 22
Mitigated UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 Basin 2.wdm
MESSU 25 MitBasin 2.MES
27 MitBasin 2.L61
28 MitBasin 2.L62
30 POCBasin 21.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
PERLND 16
IMPLND 1
IMPLND 8
COPY 501
DISPLY 1
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Basin 1 MAX 1 2 30 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
16 C, Lawn, Flat 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
16 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
16 0 0 4 0 0 0 0 0 0 0 0 0 1 9
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 23
END PRINT-INFO
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
16 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
16 0 4.5 0.03 400 0.05 0.5 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
16 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
16 0.1 0.25 0.25 6 0.5 0.25
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
16 0 0 0 0 2.5 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
1 ROADS/FLAT 1 1 1 27 0
8 SIDEWALKS/FLAT 1 1 1 27 0
END GEN-INFO
*** Section IWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
1 0 0 1 0 0 0
8 0 0 1 0 0 0
END ACTIVITY
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
1 0 0 4 0 0 0 1 9
8 0 0 4 0 0 0 1 9
END PRINT-INFO
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
# - # CSNO RTOP VRS VNN RTLI ***
1 0 0 0 0 0
8 0 0 0 0 0
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
1 400 0.01 0.1 0.1
8 400 0.01 0.1 0.1
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 24
END IWAT-PARM2
IWAT-PARM3
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
1 0 0
8 0 0
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
1 0 0
8 0 0
END IWAT-STATE1
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
Basin 1***
PERLND 16 0.07 COPY 501 12
PERLND 16 0.07 COPY 501 13
IMPLND 1 0.04 COPY 501 15
IMPLND 8 0.05 COPY 501 15
******Routing******
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
in out ***
END GEN-INFO
*** Section RCHRES***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
END HYDR-PARM2
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 25
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
END HYDR-INIT
END RCHRES
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
END FTABLES
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
COPY 1 OUTPUT MEAN 1 1 48.4 WDM 701 FLOW ENGL REPL
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 801 FLOW ENGL REPL
END EXT TARGETS
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
MASS-LINK 15
IMPLND IWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 15
END MASS-LINK
END RUN
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Basin 2 12/15/2022 10:15:02 AM Page 28
Disclaimer
Legal Notice
This program and accompanying documentation are provided 'as-is' without warranty of any kind. The
entire risk regarding the performance and results of this program is assumed by End User. Clear
Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either
expressed or implied, including but not limited to implied warranties of program and accompanying
documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever
(including without limitation to damages for loss of business profits, loss of business information,
business interruption, and the like) arising out of the use of, or inability to use this program even
if Clear Creek Solutions Inc. or their authorized representatives have been advised of the
possibility of such damages. Software Copyright © by : Clear Creek Solutions, Inc. 2005-2022; All
Rights Reserved.
Clear Creek Solutions, Inc.
6200 Capitol Blvd. Ste F
Olympia, WA. 98501
Toll Free 1(866)943-0304
Local (360)943-0304
www.clearcreeksolutions.com
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
4.5 Water Quality System
Developed Basin 1
This project is required to provide Basic Water Quality treatment according to the 2022 CORSWDM.
This requirement will be met by providing a Stormfilter System directly downstream of the onsite
detention vault. The Stormfilter System will be designed to treat the 2-year release rate from the
detention facility as outlined in the 2022 CORSWDM.
Developed Basin 2
According to Section 1.2.8 of the 2022 CORSWDM, any threshold discharge area is exempt from the
water quality facility requirement if less than 5,000 square feet of new plus replaced pollution
generating surface area will be created. This basin contains less than 5,000 square feet of new plus
replaced pollution generating surface areas, therefore a water quality facility will not be required for
this basin.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 5.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
5.0 CONVEYANCE SYSTEM ANALYSIS AND DESIGN
The onsite and frontage conveyance system will consist of curb, gutter, catch basins and storm
drainage pipe. Conveyance calculations for the pipes will be completed using the rational method
and will be provided during final engineering. These conveyance systems will be designed in
accordance with the 2022 CORSWDM.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 6.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
6.0 SPECIAL REPORTS AND STUDIES
6.1 Geotechnical Engineering Study prepared by Earth Solutions NW, LLC. dated November 21,
2022
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
EarthSolutionsNWLLC
EarthSolutions
NW LLC
15365 N.E.90th Street,Suite 100 Redmond,WA 98052
(425)449-4704 Fax (425)449-4711
www.earthsolutionsnw.com
Geotechnical Engineering
Construction Observation/Testing
Environmental Services
GEOTECHNICAL ENGINEERING STUDY
PROPOSED RESIDENTIAL PLAT
15509 –116 AVENUE SOUTHEAST
RENTON,WASHINGTON
ES-8888
TH
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
PREPARED FOR
ICHIJO USA CO., LTD.
November 21, 2022
_________________________
Chase G. Halsen, L.G.
Senior Project Geologist
_________________________
Keven D. Hoffmann, P.E.
Associate Principal Engineer
GEOTECHNICAL ENGINEERING STUDY
PROPOSED RESIDENTIAL PLAT
15509 – 116TH AVENUE SOUTHEAST
RENTON, WASHINGTON
ES-8888
Earth Solutions NW, LLC
15365 Northeast 90th Street, Suite 100
Redmond, Washington 98052
Phone: 425-449-4704 | Fax: 425-449-4711
www.earthsolutionsnw.com
11/21/2022
11/21/2022
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Geotechnical-Engineering Report
Important Information about This
Subsurface problems are a principal cause of construction delays, cost overruns, claims, and disputes.
While you cannot eliminate all such risks, you can manage them. The following information is provided to help.
The Geoprofessional Business Association (GBA)
has prepared this advisory to help you – assumedly
a client representative – interpret and apply this
geotechnical-engineering report as effectively as
possible. In that way, you can benefit from a lowered
exposure to problems associated with subsurface
conditions at project sites and development of
them that, for decades, have been a principal cause
of construction delays, cost overruns, claims,
and disputes. If you have questions or want more
information about any of the issues discussed herein,
contact your GBA-member geotechnical engineer.
Active engagement in GBA exposes geotechnical
engineers to a wide array of risk-confrontation
techniques that can be of genuine benefit for
everyone involved with a construction project.
Understand the Geotechnical-Engineering Services
Provided for this Report
Geotechnical-engineering services typically include the planning,
collection, interpretation, and analysis of exploratory data from
widely spaced borings and/or test pits. Field data are combined
with results from laboratory tests of soil and rock samples obtained
from field exploration (if applicable), observations made during site
reconnaissance, and historical information to form one or more models
of the expected subsurface conditions beneath the site. Local geology
and alterations of the site surface and subsurface by previous and
proposed construction are also important considerations. Geotechnical
engineers apply their engineering training, experience, and judgment
to adapt the requirements of the prospective project to the subsurface
model(s). Estimates are made of the subsurface conditions that
will likely be exposed during construction as well as the expected
performance of foundations and other structures being planned and/or
affected by construction activities.
The culmination of these geotechnical-engineering services is typically a
geotechnical-engineering report providing the data obtained, a discussion
of the subsurface model(s), the engineering and geologic engineering
assessments and analyses made, and the recommendations developed
to satisfy the given requirements of the project. These reports may be
titled investigations, explorations, studies, assessments, or evaluations.
Regardless of the title used, the geotechnical-engineering report is an
engineering interpretation of the subsurface conditions within the context
of the project and does not represent a close examination, systematic
inquiry, or thorough investigation of all site and subsurface conditions.
Geotechnical-Engineering Services are Performed
for Specific Purposes, Persons, and Projects,
and At Specific Times
Geotechnical engineers structure their services to meet the specific
needs, goals, and risk management preferences of their clients. A
geotechnical-engineering study conducted for a given civil engineer
will not likely meet the needs of a civil-works constructor or even a
different civil engineer. Because each geotechnical-engineering study
is unique, each geotechnical-engineering report is unique, prepared
solely for the client.
Likewise, geotechnical-engineering services are performed for a specific
project and purpose. For example, it is unlikely that a geotechnical-
engineering study for a refrigerated warehouse will be the same as
one prepared for a parking garage; and a few borings drilled during
a preliminary study to evaluate site feasibility will not be adequate to
develop geotechnical design recommendations for the project.
Do not rely on this report if your geotechnical engineer prepared it:
• for a different client;
• for a different project or purpose;
• for a different site (that may or may not include all or a portion of
the original site); or
• before important events occurred at the site or adjacent to it;
e.g., man-made events like construction or environmental
remediation, or natural events like floods, droughts, earthquakes,
or groundwater fluctuations.
Note, too, the reliability of a geotechnical-engineering report can
be affected by the passage of time, because of factors like changed
subsurface conditions; new or modified codes, standards, or
regulations; or new techniques or tools. If you are the least bit uncertain
about the continued reliability of this report, contact your geotechnical
engineer before applying the recommendations in it. A minor amount
of additional testing or analysis after the passage of time – if any is
required at all – could prevent major problems.
Read this Report in Full
Costly problems have occurred because those relying on a geotechnical-
engineering report did not read the report in its entirety. Do not rely on
an executive summary. Do not read selective elements only. Read and
refer to the report in full.
You Need to Inform Your Geotechnical Engineer
About Change
Your geotechnical engineer considered unique, project-specific factors
when developing the scope of study behind this report and developing
the confirmation-dependent recommendations the report conveys.
Typical changes that could erode the reliability of this report include
those that affect:
• the site’s size or shape;
• the elevation, configuration, location, orientation,
function or weight of the proposed structure and
the desired performance criteria;
• the composition of the design team; or
• project ownership.
As a general rule, always inform your geotechnical engineer of project
or site changes – even minor ones – and request an assessment of their
impact. The geotechnical engineer who prepared this report cannot accept
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
responsibility or liability for problems that arise because the geotechnical
engineer was not informed about developments the engineer otherwise
would have considered.
Most of the “Findings” Related in This Report
Are Professional Opinions
Before construction begins, geotechnical engineers explore a site’s
subsurface using various sampling and testing procedures. Geotechnical
engineers can observe actual subsurface conditions only at those specific
locations where sampling and testing is performed. The data derived from
that sampling and testing were reviewed by your geotechnical engineer,
who then applied professional judgement to form opinions about
subsurface conditions throughout the site. Actual sitewide-subsurface
conditions may differ – maybe significantly – from those indicated in
this report. Confront that risk by retaining your geotechnical engineer
to serve on the design team through project completion to obtain
informed guidance quickly, whenever needed.
This Report’s Recommendations Are
Confirmation-Dependent
The recommendations included in this report – including any options or
alternatives – are confirmation-dependent. In other words, they are not
final, because the geotechnical engineer who developed them relied heavily
on judgement and opinion to do so. Your geotechnical engineer can finalize
the recommendations only after observing actual subsurface conditions
exposed during construction. If through observation your geotechnical
engineer confirms that the conditions assumed to exist actually do exist,
the recommendations can be relied upon, assuming no other changes have
occurred. The geotechnical engineer who prepared this report cannot assume
responsibility or liability for confirmation-dependent recommendations if you
fail to retain that engineer to perform construction observation.
This Report Could Be Misinterpreted
Other design professionals’ misinterpretation of geotechnical-
engineering reports has resulted in costly problems. Confront that risk
by having your geotechnical engineer serve as a continuing member of
the design team, to:
• confer with other design-team members;
• help develop specifications;
• review pertinent elements of other design professionals’ plans and
specifications; and
• be available whenever geotechnical-engineering guidance is needed.
You should also confront the risk of constructors misinterpreting this
report. Do so by retaining your geotechnical engineer to participate in
prebid and preconstruction conferences and to perform construction-
phase observations.
Give Constructors a Complete Report and Guidance
Some owners and design professionals mistakenly believe they can shift
unanticipated-subsurface-conditions liability to constructors by limiting
the information they provide for bid preparation. To help prevent
the costly, contentious problems this practice has caused, include the
complete geotechnical-engineering report, along with any attachments
or appendices, with your contract documents, but be certain to note
conspicuously that you’ve included the material for information purposes
only. To avoid misunderstanding, you may also want to note that
“informational purposes” means constructors have no right to rely on
the interpretations, opinions, conclusions, or recommendations in the
report. Be certain that constructors know they may learn about specific
project requirements, including options selected from the report, only
from the design drawings and specifications. Remind constructors
that they may perform their own studies if they want to, and be sure to
allow enough time to permit them to do so. Only then might you be in
a position to give constructors the information available to you, while
requiring them to at least share some of the financial responsibilities
stemming from unanticipated conditions. Conducting prebid and
preconstruction conferences can also be valuable in this respect.
Read Responsibility Provisions Closely
Some client representatives, design professionals, and constructors do
not realize that geotechnical engineering is far less exact than other
engineering disciplines. This happens in part because soil and rock on
project sites are typically heterogeneous and not manufactured materials
with well-defined engineering properties like steel and concrete. That
lack of understanding has nurtured unrealistic expectations that have
resulted in disappointments, delays, cost overruns, claims, and disputes.
To confront that risk, geotechnical engineers commonly include
explanatory provisions in their reports. Sometimes labeled “limitations,”
many of these provisions indicate where geotechnical engineers’
responsibilities begin and end, to help others recognize their own
responsibilities and risks. Read these provisions closely. Ask questions.
Your geotechnical engineer should respond fully and frankly.
Geoenvironmental Concerns Are Not Covered
The personnel, equipment, and techniques used to perform an
environmental study – e.g., a “phase-one” or “phase-two” environmental
site assessment – differ significantly from those used to perform a
geotechnical-engineering study. For that reason, a geotechnical-engineering
report does not usually provide environmental findings, conclusions, or
recommendations; e.g., about the likelihood of encountering underground
storage tanks or regulated contaminants. Unanticipated subsurface
environmental problems have led to project failures. If you have not
obtained your own environmental information about the project site,
ask your geotechnical consultant for a recommendation on how to find
environmental risk-management guidance.
Obtain Professional Assistance to Deal with
Moisture Infiltration and Mold
While your geotechnical engineer may have addressed groundwater,
water infiltration, or similar issues in this report, the engineer’s
services were not designed, conducted, or intended to prevent
migration of moisture – including water vapor – from the soil
through building slabs and walls and into the building interior, where
it can cause mold growth and material-performance deficiencies.
Accordingly, proper implementation of the geotechnical engineer’s
recommendations will not of itself be sufficient to prevent
moisture infiltration. Confront the risk of moisture infiltration by
including building-envelope or mold specialists on the design team.
Geotechnical engineers are not building-envelope or mold specialists.
Copyright 2019 by Geoprofessional Business Association (GBA). Duplication, reproduction, or copying of this document, in whole or in part, by any means whatsoever, is strictly
prohibited, except with GBA’s specific written permission. Excerpting, quoting, or otherwise extracting wording from this document is permitted only with the express written permission of
GBA, and only for purposes of scholarly research or book review. Only members of GBA may use this document or its wording as a complement to or as an element of a report of any kind.
Any other firm, individual, or other entity that so uses this document without being a GBA member could be committing negligent or intentional (fraudulent) misrepresentation.
Telephone: 301/565-2733
e-mail: info@geoprofessional.org www.geoprofessional.org
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
November 21, 2022
ES-8888
Ichijo USA Co., Ltd.
1406 – 140th Place Northeast, Suite 104
Bellevue, Washington 98007
Attention: Mr. Kanon Kupferer
Greetings, Mr. Kupferer:
Earth Solutions NW, LLC (ESNW) is pleased to present this geotechnical report to support the
proposed project. Based on the results of our investigation, the construction of a residential
development is feasible from a geotechnical standpoint. Our study indicates the site is underlain
by ground moraine deposits (glacial till) that consist primarily of silty sand with gravel, with an
isolated area of near-surface fill. Groundwater was not exposed at the test pit locations during
the October 2022 exploration.
Based on our findings, the proposed single-family residences may be constructed on
conventional continuous and spread footing foundations that bear directly on competent native
soil, recompacted native soil, or new structural fill that is placed and compacted directly on
competent native soil. Native soil conditions considered suitable for support of the proposed
structures will likely be encountered beginning at a depth of about two feet below existing grades
across most of the property. Areas of existing fill will need to be removed or reworked to establish
suitable bearing conditions in proposed structural areas, as recommended by ESNW at the time
of construction. Where loose or unsuitable soil conditions are exposed at foundation subgrade
elevations, compaction of the soil to the specifications of structural fill or overexcavation and
replacement with suitable structural fill will be necessary.
From a geotechnical standpoint, full infiltration designs are not recommended for the project due
to the widespread prevalence of glacially consolidated soils. The dense to very dense nature of
these deposits, in addition to areas of appreciable fine contents, are the primary bases for this
opinion. Further discussion of infiltration feasibility is provided within this report.
Pertinent geotechnical recommendations are provided in this study. We appreciate the
opportunity to be of service to you on this project. If you have any questions regarding the content
of this geotechnical engineering study, please call.
Sincerely,
EARTH SOLUTIONS NW, LLC
Chase G. Halsen, L.G.
Senior Project Geologist
15365 N.E. 90th Street, Suite 100 • Redmond, WA 98052 •(425) 449-4704 • FAX (425) 449-4711
Earth Solutions NW LLC
Geotechnical Engineering, Construction
Observation/Testing and Environmental Services
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Earth Solutions NW, LLC
Table of Contents
ES-8888
PAGE
INTRODUCTION ................................................................................. 1
General .................................................................................... 1
Project Description ................................................................. 2
SITE CONDITIONS ............................................................................. 2
Surface ..................................................................................... 2
Subsurface .............................................................................. 2
Topsoil and Fill ............................................................. 3
Native Soil and Geologic Setting ................................ 3
Groundwater ................................................................. 3
Geologically Hazardous Areas .............................................. 3
Erosion Hazard ............................................................. 4
Coal Mine Hazard ......................................................... 4
DISCUSSION AND RECOMMENDATIONS ....................................... 4
General .................................................................................... 4
Site Preparation and Earthwork ............................................. 4
Temporary Erosion Control ......................................... 5
Stripping ....................................................................... 5
Excavations and Slopes .............................................. 5
In-situ and Imported Soil ............................................. 6
Subgrade Preparation .................................................. 6
Structural Fill ................................................................ 6
Foundations ............................................................................ 7
Seismic Design ....................................................................... 8
Slab-on-Grade Floors ............................................................. 9
Retaining Walls ....................................................................... 9
Drainage................................................................................... 10
Infiltration Feasibility ................................................... 10
Preliminary Detention Vault Design ............................ 10
Preliminary Pavement Sections ............................................. 11
Utility Support and Trench Backfill ....................................... 12
LIMITATIONS ...................................................................................... 13
Additional Services ................................................................. 13
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Earth Solutions NW, LLC
Table of Contents
Cont’d
ES-8888
GRAPHICS
Plate 1 Vicinity Map
Plate 2 Test Pit Location Plan
Plate 3 Retaining Wall Drainage Detail
Plate 4 Footing Drain Detail
APPENDICES
Appendix A Subsurface Exploration
Test Pit Logs
Appendix B Laboratory Test Results
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Earth Solutions NW, LLC
GEOTECHNICAL ENGINEERING STUDY
PROPOSED RESIDENTIAL PLAT
15509 – 116TH AVENUE SOUTHEAST
RENTON, WASHINGTON
ES-8888
INTRODUCTION
General
This geotechnical engineering study was prepared for the proposed residential development to
be constructed at the United Christian Church campus in Renton, Washington. This study was
prepared to provide geotechnical recommendations for currently proposed development plans
and included the following geotechnical services:
Test pits to characterize soil and groundwater conditions.
Laboratory testing of representative soil samples collected at the test pit locations.
Geotechnical engineering analyses.
The following documents and maps were reviewed as part of the preparation of this study:
Online Web Soil Survey (WSS) resource, maintained by the Natural Resources
Conservation Service under the United States Department of Agriculture (USDA).
Geologic Map of the Renton Quadrangle, King County, Washington, prepared by D.R.
Mullineaux, 1965.
Soil Survey of the King County Area, Washington, prepared by Dale E. Snyder, Philip S.
Gale, and Russell F. Pringle, in association with the USDA SCS, November 1973.
Map of the Seattle Electric Co.’s Renton Coal Mine, Map ID K31, 1919.
Mine Workings from George Watkins Evans’ Report for Renton Coal Company, Map ID
K32, 1920.
COR Maps (City of Renton GIS database).
Preliminary Plat Map, prepared by Barghausen Consulting Engineers, Inc., dated July 13,
2022.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 2
Earth Solutions NW, LLC
Project Description
The proposed project is currently pursuing construction of 20 single-family residences and
associated infrastructure improvements, which will be targeted to the central and southern site
areas. The existing church and associated improvements located within the northeast site corner
are to remain. Site ingress and egress will be provided via the west edge of 116th Avenue
Southeast, with a future potential road extension to the west. Stormwater management is
currently proposed via detention within the southwest site corner (Tract A).
At the time of report submission, specific building load plans were not available for review;
however, based on our experience with similar developments, the proposed residential structures
will likely be two stories and constructed using relatively lightly loaded wood framing supported
on conventional foundations. Perimeter footing loads will likely be about 2 to 3 kips per lineal foot.
Slab-on-grade loading is anticipated to be approximately 150 pounds per square foot (psf). Grade
cuts and/or fills of up to about five feet are expected to achieve the design elevation of most lots.
More extensive earthwork operations will likely be required to install site utilities and construct
the stormwater facility.
If the above design assumptions either change or are incorrect, ESNW should be contacted to
review the recommendations provided in this report. ESNW should review the final designs to
confirm that appropriate geotechnical recommendations have been incorporated into the plans.
SITE CONDITIONS
Surface
The subject site is located southwest of the intersection between Southeast 16th Street and 116th
Avenue Southeast, in Renton, Washington. The approximate site location is depicted on Plate 1
(Vicinity Map) and consists of King County parcel number 202305-9067, totaling a gross site area
of about 6.23 acres. The northeast site corner is currently developed with a church and
associated improvements. The remaining portions of the site are surfaced with trees and an
understory of brush and brambles. Topography generally descends to the south and southwest,
with about 25 feet of elevation change occurring within the property confines.
Subsurface
An ESNW representative observed, logged, and sampled the excavation of 12 test pits within
readily accessible areas of the site on October 17, 2022. The test pits ranged in depths from
about 8 to 14 feet below the existing ground surface (bgs) and were excavated using a trackhoe
and operator retained by ESNW. The approximate locations of the test pits are depicted on Plate
2 (Test Pit Location Plan). Please refer to the test pit logs provided in Appendix A for a more
detailed description of the encountered subsurface conditions. Representative soil samples
collected at the test pit locations were analyzed following both Unified Soil Classification System
(USCS) and USDA methods and procedures.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 3
Earth Solutions NW, LLC
Topsoil and Fill
Topsoil was encountered in approximately the upper 6 to 12 inches of existing grades at the test
pit locations. The topsoil was characterized by a dark brown color, the presence of fine organic
material, and small root intrusions. Based on our observations, an average topsoil thickness of
about six inches was encountered at the test locations during the field exploration.
Silty sand with gravel fill soil was exposed at TP-4 and observed extending to a depth of about
five feet bgs. The fill was characterized by a dense and damp condition at the time of the field
exploration. Fill was not encountered at any of the other test pit locations during the October 2022
fieldwork.
Native Soil and Geologic Setting
Underlying topsoil, native soils were classified primarily as silty sand with gravel (USCS: SM),
consistent with local geologic mapping designations of ground moraine deposits (Qgt), otherwise
known as glacial till. Variations in soil gradation were locally observed and included areas of
increased gravel, silt, and sand contents; however, silty sand with gravel sand should be
considered the predominant underlying soil type. Soils within the upper approximate three to five
feet of existing grades were generally characterized as medium dense; thereafter, native soils
become dense to very dense, extending to the terminus of each test pit location, which occurred
between about 8 and 14 feet bgs. An exception occurred at TP-4, where the native soil was
characterized as medium dense to the terminus of the test pit. Native soils were primarily
observed in a moist condition at the time of the October 2022 fieldwork.
The referenced WSS resource indicates the site is underlain by Alderwood gravelly sandy loam
(Map Unit Symbol: AgC). This soil series is associated with ridges and hills and is derived from
glacial drift. Based on the soil conditions encountered during the subsurface exploration, native
soils are considered representative of ground moraine deposits, in accordance with local mapping
designations.
Groundwater
Groundwater was not encountered within the explored depths of the test pit locations during the
October 2022 exploration. Groundwater seeps are common within glacial deposits, and the
elevations and/or flow volumes of seepages can fluctuate depending on many factors, including
precipitation duration and intensity, the time of year, and soil conditions. In general, groundwater
elevations are higher during the winter, spring, and early summer months.
Geologically Hazardous Areas
Renton Municipal Code (RMC) 4-3-050 classifies geologically hazardous areas as those areas
susceptible to damage relating to steep slopes, landslides, erosion, seismic activity, and coal
mines. Based on review of COR Maps, the site has been designated as a potential moderate
coal mine hazard area. Furthermore, based on our review of the RMC, the site is considered to
possess low erosion hazard potential.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 4
Earth Solutions NW, LLC
Erosion Hazard
RMC 4-3-050G5ci defines a low erosion hazard (EL) as areas with soil characterized as having
a slight or moderate erosion potential and a slope less than 15 percent. Based on review of the
referenced King County Soil Survey, on-site Alderwood series (AgC) soils are considered to have
a moderate erosion potential. As such, the site may be considered to possess a low erosion
hazard. A review of the development standards table presented in section 4-3-050G2 indicates
there are no required buffers or setbacks associated with EL areas. From a geotechnical
standpoint, typical best management practices (BMPs) and permanent landscaping installations
can successfully mitigate any potential soil erosion both during and after construction.
Coal Mine Hazard
COR Maps indicates the subject site is within a moderate coal mine hazard (CM) area. As defined
in RMC 4-3-050G5eii, CM areas are defined as areas where mine workings are deeper than 200
feet for steeply dipping seams, or deeper than 15 times the thickness of the seam or workings for
gently dipping seams. These areas may be affected by subsidence.
Review of the referenced coal mine hazard maps suggests the site is within the vicinity of a
historical coal mine operation. However, it appears that mining activity beneath the site area is
greater than 200 feet. On this basis, the subject site is considered appropriately mapped within a
CM area per the RMC definition. Per the development standards table presented in RMC 4-3-
050G2, there are no code-specified buffers or setbacks for CM areas “based on the results of a
geotechnical report and/or independent review.” From a geotechnical standpoint, it is our opinion
buffers and/or setbacks need not be applied to the project with respect to the CM area.
Construction of the proposed residential development is not expected to increase the potential
for ground subsidence on the subject site. This opinion relies on the validity of the information
presented in the referenced coal mine maps.
DISCUSSION AND RECOMMENDATIONS
General
Based on the results of our investigation, the construction of the proposed residential
development is feasible from a geotechnical standpoint. The primary geotechnical considerations
for the proposed development concern structural fill placement and compaction, foundation
design, and stormwater management design.
Site Preparation and Earthwork
Initial site preparation activities will consist of installing temporary erosion control measures,
establishing grading limits, and site clearing and stripping activities. Subsequent earthwork
activities will involve mass site grading and installation of infrastructure and stormwater
management improvements.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 5
Earth Solutions NW, LLC
Temporary Erosion Control
The following temporary erosion and sediment control Best Management Practices (TESC
BMPs) are offered:
Temporary construction entrances and drive lanes should be constructed with at least six
inches of quarry spalls to both minimize off-site soil tracking and provide a stable access
entrance surface. A woven geotextile fabric can be placed beneath the quarry spalls to
provide greater stability, if needed.
Silt fencing should be placed around the site perimeter.
When not in use, soil stockpiles should be covered or otherwise protected.
Temporary measures for controlling surface water runoff, such as interceptor trenches,
sumps, or interceptor swales, should be installed before beginning earthwork activities.
Dry soils disturbed during construction should be wetted to reduce dust.
When appropriate, permanent planting or hydroseeding will help to stabilize site soils.
Additional TESC BMPs, as specified by the project civil engineer on the plans, should be
incorporated into construction activities. TESC measures will require upkeep and potential
modification during construction to ensure proper function; such upkeep should be coordinated
with the site erosion control lead, where applicable.
Stripping
Topsoil was generally encountered in the upper approximately 6 to 12 inches of existing grades
at the test pit locations. For stripping estimations, an average topsoil thickness of about six inches
can be assumed, based on our field observations. Where encountered, organic-rich topsoil
should be stripped and segregated into a stockpile for later use on site or to be exported.
Excavations and Slopes
Based on the soil conditions observed at the test pit locations, the following allowable temporary
slope inclinations, as a function of horizontal to vertical (H:V) inclination, may be used. The
applicable Federal Occupation Safety and Health Administration (OSHA) and Washington
Industrial Safety and Health Act (WISHA) soil classifications are also provided:
Loose to medium dense soil 1.5H:1V (Type C)
Areas exposing groundwater seepage 1.5H:1V (Type C)
Dense to very dense, undisturbed native soil 0.75H:1V (Type A)
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 6
Earth Solutions NW, LLC
Steeper temporary slope inclinations within undisturbed, very dense native soil may be feasible
based on the soil and groundwater conditions exposed within the excavations. ESNW can
evaluate the feasibility of utilizing steeper temporary slopes on a case-by-case basis at the time
of construction. In any case, an ESNW representative should observe temporary slopes to
confirm inclinations are suitable for the exposed soil conditions and to provide additional
excavation and slope stability recommendations, as necessary.
If the recommended temporary slope inclinations cannot be achieved, temporary shoring may be
necessary to support excavations. Permanent slopes should be graded to 2H:1V (or flatter) and
planted with vegetation to enhance stability and minimize erosion potential. Permanent slopes
should be observed by ESNW before vegetation and landscaping.
In-situ and Imported Soil
Successful use of the on-site soil as structural fill will largely be dictated by the moisture content
at the time of placement and compaction. Based on the conditions observed during the
subsurface exploration, the native soils are considered to possess a moderate to high moisture
sensitivity. Depending on the time of year construction occurs, remedial measures (such as soil
aeration) may be necessary as part of site grading and earthwork activities. If the on-site soil
cannot be successfully compacted, the use of imported soil may be necessary. In our opinion, a
contingency should be provided in the project budget for the export of soil that cannot be
successfully compacted as structural fill, particularly if grading activities take place during periods
of extended rainfall activity. In general, soils with fines contents greater than 5 percent typically
degrade rapidly when exposed to periods of rainfall.
Imported structural fill soil should consist of well-graded, granular soil that can achieve a suitable
working moisture content. During wet weather conditions, imported soil intended for use as
structural fill should consist of a well-graded, granular soil with a fines content of 5 percent or less
(where the fines content is defined as the percent passing the Number 200 sieve, based on the
minus three-quarter-inch fraction).
Subgrade Preparation
Foundation and slab subgrade surfaces should consist of competent, undisturbed native soil or
structural fill placed and compacted atop competent native soil. ESNW should observe subgrade
areas before placing formwork. Supplementary recommendations for subgrade improvement
may be provided at the time of construction; such recommendations would likely include further
mechanical compaction effort or overexcavation and replacement with suitable structural fill.
Structural Fill
Structural fill is defined as compacted soil placed in foundation, slab-on-grade, roadway,
permanent slope, retaining wall, and utility trench backfill areas. The following recommendations
are provided for soils intended for use as structural fill:
Moisture content At or slightly above optimum
Relative compaction (minimum) 95 percent (per ASTM D1557)
Loose lift thickness (maximum) 12 inches
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 7
Earth Solutions NW, LLC
Existing site soil may only be considered suitable for use as structural fill if a suitable moisture
content is achieved at the time of placement and compaction. If the on-site soil cannot achieve
the above specifications, the use of imported structural fill material will likely be necessary.
Concerning underground utility installations and backfill, local jurisdictions will likely dictate soil
type(s) and compaction requirements.
Foundations
Based on our findings, the proposed single-family residences may be constructed on
conventional continuous and spread footing foundations that bear directly on competent native
soil, recompacted native soil, or new structural fill that is placed and compacted directly on
competent native soil. Native soil conditions considered suitable for support of the proposed
structures will likely be encountered beginning at a depth of about two feet bgs across most of
the site. Areas of existing fill (such as at TP-4) will need to be removed or reworked to establish
suitable bearing conditions in proposed structural areas, as recommended by ESNW at the time
of construction. Where loose or unsuitable soil conditions are exposed at foundation subgrade
elevations, compaction of the soil to the specifications of structural fill or overexcavation and
replacement with suitable structural fill will be necessary.
Provided the foundations will be supported as prescribed, the following parameters may be used
for the design:
Allowable soil bearing capacity 2,500 psf
Passive earth pressure 350 pcf (equivalent fluid)
Coefficient of friction 0.40
The above passive pressure and friction values include a factor-of-safety (FOS) of 1.5. A one-
third increase in the allowable soil bearing capacity may be assumed for short-term wind and
seismic loading conditions. With structural loading as expected, total settlement in the range of
one inch and differential settlement of about one-half inch is anticipated. Most settlements should
occur during construction when dead loads are applied.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 8
Earth Solutions NW, LLC
Seismic Design
The 2018 International Building Code (2018 IBC) recognizes the most recent edition of the
Minimum Design Loads for Buildings and Other Structures manual (ASCE 7-16) for seismic
design, specifically concerning earthquake loads. Based on the soil conditions encountered at
the test locations, the parameters and values provided below are recommended for seismic
design per the 2018 IBC.
Parameter Value
Site Class C*
Mapped short-period spectral response acceleration, SS (g) 1.407
Mapped 1-second period spectral response acceleration, S1 (g) 0.48
Short period site coefficient, Fa 1.2
Long-period site coefficient, Fv 1.5
Adjusted short-period spectral response acceleration, SMS (g) 1.689
Adjusted 1-second period spectral response acceleration, SM1 (g) 0.72
Design short-period spectral response acceleration, SDS (g) 1.126
Design 1-second period spectral response acceleration, SD1 (g) 0.48
* Assumes very dense soil conditions, encountered to a maximum depth of 14 feet bgs during the October 2022
field exploration, remain very dense to at least 100 feet bgs. Based on our experience with the project geologic
setting (glacial till) across the Puget Sound region, soil conditions are likely consistent with this assumption.
Further discussion between the project structural engineer, the project owner (or their
representative), and ESNW may be prudent to determine the possible impacts on the structural
design due to increased earthquake load requirements under the 2018 IBC. ESNW can provide
additional consulting services to aid with design efforts, including supplementary geotechnical
and geophysical investigation, upon request.
Liquefaction is a phenomenon that can occur within a soil profile as a result of an intense ground
shaking or loading condition. Most commonly, liquefaction is caused by ground shaking during
an earthquake. Soil profiles that are loose, cohesionless, and present below the groundwater
table are most susceptible to liquefaction. During the ground shaking, the soil contracts, and
porewater pressure increases. The increased porewater pressure occurs quickly and without
sufficient time to dissipate, resulting in water flowing upward to the ground surface and a liquefied
soil condition. Soil in a liquefied condition possesses very little shear strength in comparison to
the drained condition, which can result in a loss of foundation support for structures. In our
opinion, site susceptibility to liquefaction may be considered negligible. The absence of a shallow
groundwater table and the dense characteristics of the native soil were the primary bases for this
opinion.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 9
Earth Solutions NW, LLC
Slab-on-Grade Floors
Slab-on-grade floors for the proposed residential structures should be supported by competent,
firm, and unyielding subgrades. Unstable or yielding subgrade areas should be recompacted or
overexcavated and replaced with suitable structural fill before slab construction. A capillary break
consisting of at least four inches of free-draining crushed rock or gravel should be placed below
each slab. The free-draining material should have a fines content of 5 percent or less (where the
fines content is defined as the percent passing the Number 200 sieve, based on the minus three-
quarter-inch fraction). In areas where slab moisture is undesirable, the installation of a vapor
barrier below the slab should be considered. Vapor barriers should be made from material
specifically designed for use as a vapor barrier and should be installed in accordance with the
manufacturer’s recommendations.
Retaining Walls
Retaining walls must be designed to resist earth pressures and applicable surcharge loads. The
following parameters may be used for the design:
Active earth pressure (unrestrained condition) 35 pcf (equivalent fluid)
At-rest earth pressure (restrained condition) 55 pcf
Traffic surcharge* (passenger vehicles) 70 psf (rectangular distribution)
Passive earth pressure 350 pcf (equivalent fluid)
Coefficient of friction 0.40
Seismic surcharge 8H psf†
* Where applicable.
† Where H equals the retained height (in feet).
The above passive pressure and friction values include a FOS of 1.5 and are based on a level
backfill condition and level grade at the wall toe. Revised design values will be necessary if
sloping grades are to be used above or below retaining walls. Additional surcharge loading from
adjacent foundations, sloped backfill, or other relevant loads should be included in the retaining
wall design.
Retaining walls should be backfilled with free-draining material that extends along with the height
of the wall and a distance of at least 18 inches behind the wall. The upper 12 inches of the wall
backfill may consist of less permeable soil, if desired. A sheet drain may be considered instead
of using free-draining backfill. A perforated drainpipe should be placed along the base of the wall
and connected to an approved discharge location. A typical retaining wall drainage detail is
provided on Plate 3. If drainage is not provided, hydrostatic pressures should be included in the
wall design.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 10
Earth Solutions NW, LLC
Drainage
Zones of perched groundwater seepage could develop in site excavations depending on the time
of year grading operations take place, particularly within deeper excavations for utilities and
stormwater facilities. Temporary measures to control surface water runoff and groundwater
during construction would likely involve interceptor trenches, interceptor swales, and sumps.
ESNW should be consulted during preliminary grading to both identify areas of seepage and
provide recommendations to reduce the potential for seepage-related instability.
Finish grades must be designed to direct surface drain water away from structures and slopes.
Water must not be allowed to pond adjacent to structures or slopes. In our opinion, foundation
drains should be installed along building perimeter footings. A typical foundation drain detail is
provided on Plate 4.
Infiltration Feasibility
From a geotechnical standpoint, full infiltration designs are considered infeasible for the project.
The site is predominately underlain by glacially consolidated deposits that consist primarily of
silty sand with gravel. As a result of the dense in-situ condition of the native soil and areas of
appreciable fines contents, large-scale infiltration implementations would likely exhibit poor to
negligible functionality and would not be expected to have suitable long-term performance.
Small-scale BMP or LID designs (such as permeable pavement or shallow gravel-filled trenches)
may be viable for the project; however, feasibility will largely depend on the grading plan, since
any such implementation would need to target the weathered soil horizon located within the upper
few feet of existing grades. As such, if significant grade cuts are proposed, small-scale BMP or
LID designs will likely not be feasible from a geotechnical standpoint. If desired, ESNW can
further evaluate the feasibility of incorporating small-scale BMP or LID designs into the project. If
pursued, in-situ infiltration testing will likely be necessary to confirm the feasibility of utilizing such
designs and to develop a suitable design infiltration rate.
Preliminary Detention Vault Design
We presume that stormwater management will likely be provided via a stormwater detention vault
located within the southwestern site corner (Tract A). We anticipate grade cuts of 10 or more feet
will be necessary to achieve the subgrade elevation of the vault foundation. Based on our field
observations, grade cuts for the vault are likely to expose competent, native glacial till deposits.
The vault foundation should be supported directly on very dense native soil or quarry spalls
placed directly on competent native soil. The final vault design must incorporate adequate space
from property boundaries such that temporary excavations to construct the vault structure may
be successfully completed using the recommended temporary slope inclinations provided in this
report. Perimeter drains should be installed around the vault and conveyed to an approved
discharge point. In our opinion, perched groundwater seepage should be anticipated along the
temporary excavation made for construction of the vault; however, buoyancy is not expected to
impact the vault design.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 11
Earth Solutions NW, LLC
The following preliminary design parameters may be used for the vault:
Allowable soil bearing capacity 5,000 psf
Active earth pressure (unrestrained) 35 pcf
Active earth pressure (unrestrained, hydrostatic) 80 pcf
At-rest earth pressure (restrained) 55 pcf
At-rest earth pressure (restrained, hydrostatic) 100 pcf
Coefficient of friction 0.40
Passive earth pressure 350 pcf
Seismic surcharge 8H psf*
* Where H equals the retained height (in feet).
The passive earth pressure and coefficient of friction values include a FOS of 1.5. Vault retaining
walls should be backfilled with free-draining material or suitable sheet drainage that extends
along the height of the walls. The upper one foot of the wall backfill may consist of a less
permeable soil, if desired. A perforated-rigid drainpipe should be placed along the base of the
wall and connected to an approved discharge location. If the elevation of the vault bottom is such
that gravity flow to an outlet is not possible, the portions of the vault below the drain should be
designed to include hydrostatic pressure.
It is our recommendation that ESNW, the owner, and the contractor observe the excavation of a
test pit within the vault area prior to excavation activities. The test pit exploration will assist in
confirming anticipated soil conditions at the vault subgrade and characterizing seasonal
groundwater conditions, which may impact the temporary excavation and grading plan.
Preliminary Pavement Sections
The performance of site pavements is largely related to the condition of the underlying subgrade.
To ensure adequate pavement performance, the subgrade should be in a firm and unyielding
condition when subjected to proofrolling with a loaded dump truck. Structural fill in pavement
areas should be compacted to the specifications previously detailed in this report. Soft, wet, or
otherwise unsuitable subgrade areas may still exist after base grading activities. Areas containing
unsuitable or yielding subgrade conditions will require remedial measures, such as
overexcavation and/or placement of thicker crushed rock or structural fill sections, before
pavement.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 12
Earth Solutions NW, LLC
We anticipate new pavement sections will be subjected primarily to passenger vehicle traffic. For
lightly loaded pavement areas subjected primarily to passenger vehicles, the following
preliminary pavement sections may be considered:
A minimum of two inches of hot-mix asphalt (HMA) placed over four inches of crushed
rock base (CRB).
A minimum of two inches of HMA placed over three inches of asphalt-treated base (ATB).
Heavier traffic areas generally require thicker pavement sections depending on site usage,
pavement life expectancy, and site traffic. For preliminary design purposes, the following
pavement sections for occasional truck traffic and access roadways areas may be considered:
Three inches of HMA placed over six inches of CRB.
Three inches of HMA placed over four-and-one-half inches of ATB.
An ESNW representative should be requested to observe subgrade conditions before the
placement of CRB or ATB. As necessary, supplemental recommendations for achieving
subgrade stability and drainage can be provided. If the on-site roads will be constructed with an
inverted crown, additional drainage measures may be recommended to assist in maintaining road
subgrade and pavement stability.
Final pavement design recommendations, including recommendations for heavy traffic areas,
access roads, and frontage improvement areas, can be provided once final traffic loading has
been determined. Road standards utilized by the governing jurisdiction may supersede the
recommendations provided in this report. The HMA, ATB, and CRB materials should conform to
WSDOT specifications, where applicable. All soil base material should be compacted to a relative
compaction of 95 percent, based on the laboratory maximum dry density as determined by ASTM
D1557.
Utility Support and Trench Backfill
In our opinion, the native soil will generally be suitable for the support of utilities. Remedial
measures may be necessary for some areas to provide support for utilities, such as
overexcavation and replacement with structural fill and/or placement of geotextile fabric.
Groundwater seepage may be encountered within utility excavations, and caving of trench walls
may occur where groundwater is encountered. Depending on the time of year and conditions
encountered, dewatering or temporary trench shoring may be necessary during utility excavation
and installation.
The on-site soil is not considered suitable for use as structural backfill throughout the utility trench
excavations unless the soil is at (or slightly above) the optimum moisture content at the time of
placement and compaction. Moisture conditioning of the soil may be necessary at some locations
before use as structural fill. Each section of the utility lines must be adequately supported by the
bedding material. Utility trench backfill should be placed and compacted to the structural fill
specifications previously detailed in this report or to the applicable specifications of the presiding
jurisdiction.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Ichijo USA Co., Ltd. ES-8888
November 21, 2022 Page 13
Earth Solutions NW, LLC
LIMITATIONS
This study has been prepared for the exclusive use of Ichijo USA Co., Ltd. and its representatives.
The recommendations and conclusions provided in this study are professional opinions
consistent with the level of care and skill that is typical of other members in the profession
currently practicing under similar conditions in this area. No warranty, express or implied, is made.
Variations in the soil and groundwater conditions observed at the test locations may exist and
may not become evident until construction. ESNW should reevaluate the conclusions provided
in this study if variations are encountered.
Additional Services
ESNW should have an opportunity to review the final project plans concerning the geotechnical
recommendations provided in this report. ESNW should also be retained to provide testing and
consultation services during construction.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Geotechnical Engineering,Construction
Observation/Testing and Environmental Services
Drwn.MRS
Checked CGH Date Nov.2022
Date 11/21/2022 Proj.No.8888
Plate 1
Earth Solutions NWLLCEarthSolutionsNWLLC
EarthSolutions
NW LLC
Vicinity Map
United Christian Church Property
Renton,Washington
Reference:
King County,Washington
OpenStreetMap.org
NORTH
NOTE:This plate may contain areas of color.ESNW cannot be
responsible for any subsequent misinterpretation of the information
resulting from black &white reproductions of this plate.
SITE
Renton
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Plate
Proj.No.
Date
Checked By
Drwn.ByEarthSolutionsNWLLCGeotechnicalEngineering,ConstructionObservation/TestingandEnvironmentalServicesEarthSolutionsNWLLCEarthSolutionsNWLLCMRS
NORTH
NOTE:This plate may contain areas of color.ESNW cannot be
responsible for any subsequent misinterpretation of the information
resulting from black &white reproductions of this plate.
NOTE:The graphics shown on this plate are not intended for design
purposes or precise scale measurements,but only to illustrate the
approximate test locations relative to the approximate locations of
existing and /or proposed site features.The information illustrated
is largely based on data provided by the client at the time of our
study.ESNW cannot be responsible for subsequent design changes
or interpretation of the data by others.
LEGEND
Approximate Location of
ESNW Test Pit,Proj.No.
ES-8888,Oct.2022
Subject Site
Existing Buildings
(to remain)
Proposed Lot Number
0 1 0 0 2 0 0
Scale in Feet1"=2 0 0 '
CGH
11/21/2022
8888
2TestPitLocationPlan UnitedChristianChurchPropertyRenton,WashingtonTP-1
10
TP-1
TP-2
TP-3
TP-4
TP-5TP-6
TP-7
TP-8 TP-10
TP-11
TP-12
TP-9
1
2
3
4
5
67
8
9
10
11
1213
14
15
16
17
18
19 20
116TH AVENUE S.E.S.E. 157THSTREET
E
D
MO
N
DS WA
Y S.E.
Tract C
Tract B
Tract A
S.E. 19
T
H
S
T
R
E
E
T
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Geotechnical Engineering,Construction
Observation/Testing and Environmental Services
Drwn.MRS
Checked CGH Date Nov.2022
Date 11/21/2022 Proj.No.8888
Plate 3
Earth Solutions NWLLCEarthSolutionsNWLLC
EarthSolutions
NW LLC
NOTES:
Free-draining Backfill should consist
of soil having less than 5 percent fines.
Percent passing No.4 sieve should be
25 to 75 percent.
Sheet Drain may be feasible in lieu
of Free-draining Backfill,per ESNW
recommendations.
Drain Pipe should consist of perforated,
rigid PVC Pipe surrounded with 1-inch
Drain Rock.
LEGEND:
Free-draining Structural Backfill
1-inch Drain Rock
18"Min.
Structural
Fill
Perforated Rigid Drain Pipe
(Surround in Drain Rock)
SCHEMATIC ONLY -NOT TO SCALE
NOT A CONSTRUCTION DRAW ING
Retaining Wall Drainage Detail
United Christian Church Property
Renton,Washington
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Geotechnical Engineering,Construction
Observation/Testing and Environmental Services
Drwn.MRS
Checked CGH Date Nov.2022
Date 11/21/2022 Proj.No.8888
Plate 4
Earth Solutions NWLLCEarthSolutionsNWLLC
EarthSolutions
NW LLC
Slope
Perforated Rigid Drain Pipe
(Surround in Drain Rock)
18"Min.
NOTES:
Do NOT tie roof downspouts
to Footing Drain.
Surface Seal to consist of
12"of less permeable,suitable
soil.Slope away from building.
LEGEND:
Surface Seal:native soil or
other low-permeability material.
1-inch Drain Rock
SCHEMATIC ONLY -NOT TO SCALE
NOT A CONSTRUCTION DRAW ING
Footing Drain Detail
United Christian Church Property
Renton,Washington
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Earth Solutions NW, LLC
Appendix A
Subsurface Exploration
Test Pit Logs
ES-8888
Subsurface conditions at the subject site were explored on October 17, 2022. Twelve test pits
were excavated using a trackhoe and operator retained by ESNW. The approximate locations of
the test pits are illustrated on Plate 2 of this study. The test pit logs are provided in this Appendix.
The test pits were advanced to a maximum depth of approximately 14 feet bgs.
The final logs represent the interpretations of the field logs and the results of laboratory analyses.
The stratification lines on the logs represent the approximate boundaries between soil types. In
actuality, the transitions may be more gradual.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
>12%Fines<5%FinesHighlyOrganicSoilsSiltsandClaysLiquidLimit50orMoreSiltsandClaysLiquidLimitLessThan50Fine-GrainedSoils-50%orMorePassesNo.200SieveCoarse-GrainedSoils-MoreThan50%RetainedonNo.200SieveSands-50%orMoreofCoarseFractionPassesNo.4SieveGravels-MoreThan50%ofCoarseFractionRetainedonNo.4Sieve>12%Fines<5%FinesGW
GP
GM
GC
SW
SP
SM
SC
ML
CL
OL
MH
CH
OH
PT
Well-graded gravel with
or without sand,little to
no fines
Poorly graded gravel with
or without sand,little to
no fines
Silty gravel with or without
sand
Clayey gravel with or
without sand
Well-graded sand with
or without gravel,little to
no fines
Poorly graded sand with
or without gravel,little to
no fines
Silty sand with or without
gravel
Clayey sand with or
without gravel
Silt with or without sand
or gravel;sandy or
gravelly silt
Clay of low to medium
plasticity;lean clay with
or without sand or gravel;
sandy or gravelly lean clay
Organic clay or silt of
low plasticity
Elastic silt with or without
sand or gravel;sandy or
gravelly elastic silt
Clay of high plasticity;
fat clay with or without
sand or gravel;sandy or
gravelly fat clay
Organic clay or silt of
medium to high plasticity
Peat,muck,and other
highly organic soils
EEaarrtthh SSoolluuttiioonnss NNWW LLC
Geotechnical Engineering,Construction
Observation/Testing and Environmental Services
EXPLORATION LOG KEYFillFILLMadeGround
Classifications of soils in this geotechnical report and as shown on the exploration logs are based on visual
field and/or laboratory observations,which include density/consistency,moisture condition,grain size,and
plasticity estimates,and should not be construed to imply field or laboratory testing unless presented herein.
Visual-manual and/or laboratory classification methods of ASTM D2487 and D2488 were used as an
identification guide for the Unified Soil Classification System.
Terms Describing Relative Density and Consistency
Coarse-Grained Soils:
Fine-Grained Soils:
SPT blows/foot
SPT blows/foot
Test Symbols &Units
Fines =Fines Content (%)
MC =Moisture Content (%)
DD =Dry Density (pcf)
Str =Shear Strength (tsf)
PID =Photoionization Detector (ppm)
OC =Organic Content (%)
CEC =Cation Exchange Capacity (meq/100 g)
LL =Liquid Limit (%)
PL =Plastic Limit (%)
PI =Plasticity Index (%)
Component Definitions
Descriptive Term Size Range and Sieve Number
Smaller than No.200 (0.075 mm)
Boulders
Modifier Definitions
Percentage by
Weight (Approx.)
<5
5 to 14
15 to 29
>30_
Modifier
Trace (sand,silt,clay,gravel)
Slightly (sandy,silty,clayey,gravelly)
Sandy,silty,clayey,gravelly
Very (sandy,silty,clayey,gravelly)
Moisture Content
Dry -Absence of moisture,dusty,dry to
the touch
Damp -Perceptible moisture,likely below
optimum MC
Moist -Damp but no visible water,likely
at/near optimum MC
Wet -Water visible but not free draining,
likely above optimum MC
Saturated/Water Bearing -Visible free
water,typically below groundwater table
Symbols
Cement grout
surface seal
Bentonite
chips
Grout
seal
Filter pack with
blank casing
section
Screened casing
or Hydrotip with
filter pack
End cap
ATD =At time
of drilling
Static water
level (date)
_>50
Density
Very Loose
Loose
Medium Dense
Dense
Very Dense
Consistency
Very Soft
Soft
Medium Stiff
Stiff
Very Stiff
Hard
<4
4 to 9
10 to 29
30 to 49
<2
2 to 3
4 to 7
8 to 14
15 to 29
_>30
EEaarrtthh
NNWWLLC
EarthSolutions
NW LLC
Cobbles
Gravel
Coarse Gravel
Fine Gravel
Sand
Coarse Sand
Medium Sand
Fine Sand
Silt and Clay
Larger than 12"
3"to 12"
3"to No.4 (4.75 mm)
3"to 3/4"
3/4"to No.4 (4.75 mm)
No.4 (4.75 mm)to No.200 (0.075 mm)
No.4 (4.75 mm)to No.10 (2.00 mm)
No.10 (2.00 mm)to No.40 (0.425 mm)
No.40 (0.425 mm)to No.200 (0.075 mm)
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 5.3
MC = 3.0
MC = 5.5
Fines = 8.7
MC = 10.9
MC = 8.8
Fines = 7.6
OC = 0.8
CEC = 4.8
TPSL
SM
SP-
SM
Dark brown TOPSOIL, root intrusions to 2'
Brown silty SAND with gravel, medium dense to dense, damp
-becomes dense
-becomes weakly cemented
Brown poorly graded SAND with silt, loose to medium dense, damp
[USDA Classification: slightly gravelly SAND]
-becomes medium dense, moist
-increasing gravels
[USDA Classification: gravelly SAND]
Test pit terminated 13.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
6.5
13.0SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-1
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46358 LONGITUDE -122.188
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 6.8
MC = 4.7
MC = 6.2
TPSL
SM
SP-
SM
Dark brown TOPSOIL, root intrusions to 2'
Brown silty SAND with gravel, medium dense, damp
-becomes gray, dense
-weakly cemented
Gray poorly graded SAND with silt and gravel, medium dense, damp
Test pit terminated at 11.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
7.5
11.0SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-2
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46387 LONGITUDE -122.18776
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 4.4
Fines = 36.0
MC = 9.9
MC = 6.1
MC = 4.1
TPSL
SM
SP-
SM
Dark brown TOPSOIL, root intrusions to 1.5'
Brown silty SAND with gravel, medium dense, damp
[USDA Classification: gravelly sandy LOAM]
-becomes dense
-weakly cemented
Brown poorly graded SAND with silt, medium dense, damp
Test pit terminated at 10.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
9.0
10.0SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-3
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46418 LONGITUDE -122.1872
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 6.0
MC = 5.8
MC = 4.8
MC = 3.8
TPSL
SM
SM
Dark brown TOPSOIL, shallow root intrusions (Fill)
Brown silty SAND with gravel, dense, damp (Fill)
-becomes gray, dense pieces
-topsoil horizon at 5'
Brown silty SAND with gravel, medium dense, damp
-weathered soils
Test pit terminated at 10.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
5.0
10.0SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-4
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46371 LONGITUDE -122.18641
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 4.4
MC = 9.9
MC = 6.8
Fines = 53.5
MC = 6.4
TPSL
SM
ML
Dark brown TOPSOIL, root intrusions to 3'
Brown silty SAND with gravel, medium dense to dense, damp
Brown sandy SILT, dense, damp
-becomes gray, dense to very dense
[USDA Classification: slightly gravelly LOAM]
Test pit terminated at 10.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
3.5
10.0SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-5
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46325 LONGITUDE -122.18844
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 6.5
MC = 8.9
MC = 3.2
TPSL
SM
SM
Dark brown TOPSOIL, root intrusions to 2'
Brown silty SAND with gravel, medium dense, damp
-becomes gray, weakly cemented
-becomes dense
Brown silty SAND, dense, moist
Test pit terminated at 14.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
1.0
13.0
14.0SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-6
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46336 LONGITUDE -122.18776
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 3.7
MC = 4.7
OC = 0.7
CEC = 3.0
MC = 6.1
MC = 4.5
Fines = 13.8
TPSL
GM
SM
Dark brown TOPSOIL, root intrusions to 3'
Brown silty GRAVEL with sand, medium dense, damp
-becomes dense
-weakly cemented
Brown silty SAND, dense, damp
[USDA Classification: gravelly loamy SAND]
Test pit terminated at 12.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
6.5
12.0SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-7
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46364 LONGITUDE -122.18817
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 2.9
MC = 4.5
MC = 4.1
Fines = 15.2
MC = 7.2
OC = 0.7
CEC = 3.4
TPSL
GM
SM
Dark brown TOPSOIL, root intrusions to 2'
Brown silty GRAVEL with sand, medium dense, damp
-becomes gray, dense
Brown silty SAND with gravel, medium dense, damp
[USDA Classification: very gravelly loamy SAND]
Test pit terminated at 10.5 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
1.0
7.5
10.5SAMPLE TYPENUMBERDEPTH(ft)0
5
10
PAGE 1 OF 1
TEST PIT NUMBER TP-8
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46361 LONGITUDE -122.18772
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 7.2
MC = 3.0
TPSL
SM
Dark brown TOPSOIL, minimal root intrusions
Brown silty SAND with gravel, medium dense, damp
-becomes gray, dense
-weakly cemented
Test pit terminated at 8.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
8.0SAMPLE TYPENUMBERDEPTH(ft)0
5
PAGE 1 OF 1
TEST PIT NUMBER TP-9
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46352 LONGITUDE -122.18669
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 8.6
MC = 9.4
TPSL
SM
Dark brown TOPSOIL, minimal root intrusions
Brown silty SAND with gravel, medium dense, damp
-becomes gray, dense
-weakly cemented
Test pit terminated at 9.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
9.0SAMPLE TYPENUMBERDEPTH(ft)0
5
PAGE 1 OF 1
TEST PIT NUMBER TP-10
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46357 LONGITUDE -122.1873
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 5.0
MC = 12.2
MC = 3.2
TPSL
GM
SM
Dark brown TOPSOIL, minimal root intrusions
Brown silty GRAVEL with sand, medium dense, damp
Gray silty SAND with gravel, dense, moist
-becomes damp
Test pit terminated at 9.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
4.0
9.0SAMPLE TYPENUMBERDEPTH(ft)0
5
PAGE 1 OF 1
TEST PIT NUMBER TP-11
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46386 LONGITUDE -122.18699
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
MC = 6.8
MC = 5.4
MC = 7.0
TPSL
SM
Dark brown TOPSOIL, root intrusions to 2'
Brown silty SAND with gravel, medium dense, damp
-becomes gray, dense
-weakly cemented
Test pit terminated at 9.0 feet below existing grade. No groundwater encountered during
excavation. No caving observed.
LIMITATIONS: Ground elevation (if listed) is approximate; the test location was not surveyed.
Coordinates are approximate and based on the WGS84 datum. Do not rely on this test log as a
standalone document. Refer to the text of the geotechnical report for a complete understanding
of subsurface conditions.
0.5
9.0SAMPLE TYPENUMBERDEPTH(ft)0
5
PAGE 1 OF 1
TEST PIT NUMBER TP-12
EXCAVATION CONTRACTOR NW Excavating
DATE STARTED 10/17/22 COMPLETED 10/17/22
GROUND WATER LEVEL:
GROUND ELEVATION
LATITUDE 47.46394 LONGITUDE -122.18649
LOGGED BY SES CHECKED BY KDH
NOTES
SURFACE CONDITIONS Duff
AT TIME OF EXCAVATIONAT TIME OF EXCAVATION
AFTER EXCAVATION
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GENERAL BH / TP / WELL - 8888.GPJ - GINT US.GDT - 11/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
TESTS
U.S.C.S.MATERIAL DESCRIPTION
GRAPHICLOGDocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Earth Solutions NW, LLC
Appendix B
Laboratory Test Results
ES-8888
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
0.0010.010.1110100
3
D100
140
Specimen Identification
1
fine
6
HYDROMETER
304
8.7
7.6
36.0
53.5
13.8
101/2
COBBLES
Specimen Identification
4
coarse
20 401.5 8 14
USDA: Brown Slightly Gravelly Sand. USCS: SP-SM.
USDA: Brown Gravelly Sand. USCS: SP-SM with Gravel.
USDA: Brown Gravelly Sandy Loam. USCS: SM with Gravel.
USDA: Gray Slightly Gravelly Loam. USCS: Sandy ML.
USDA: Brown Gravelly Loamy Sand. USCS: SM.
6 60
PERCENT FINER BY WEIGHTD10
0.232
0.315
0.259
0.362
0.544
0.399
0.156
0.486
GRAIN SIZE DISTRIBUTION
100
4.02
3.45
LL
TP-01
TP-01
TP-03
TP-05
TP-07
0.09
0.158
3/4
U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS
GRAVEL SAND
4.75
19
37.5
19
19
%Silt
1.65
1.16
TP-01
TP-01
TP-03
TP-05
TP-07
2 2003
Cc CuClassification
%Clay
16
PID60 D30
coarse SILT OR CLAYfinemedium
GRAIN SIZE IN MILLIMETERS
3/8 50
7.5ft.
13.0ft.
2.0ft.
5.5ft.
12.0ft.
7.50ft.
13.00ft.
2.00ft.
5.50ft.
12.00ft.
PL
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GRAIN SIZE USDA ES-8888 UNITED CHRISTIAN CHURCH PROPERTY.GPJ GINT US LAB.GDT 10/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
0.0010.010.1110100
3
D100
140
Specimen Identification
1
fine
6
HYDROMETER
304
15.2
21.8
101/2
COBBLES
Specimen Identification
4
coarse
20 401.5 8 14
USDA: Brown Very Gravelly Loamy Sand. USCS: SM with Gravel.
USDA: Brown Very Gravelly Sandy Loam. USCS: GM with Sand.
6 60
PERCENT FINER BY WEIGHTD10
0.33
0.266
4.135
9.182
GRAIN SIZE DISTRIBUTION
100
LL
TP-08
TP-11
3/4
U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS
GRAVEL SAND
37.5
37.5
%Silt
TP-08
TP-11
2 2003
Cc CuClassification
%Clay
16
PID60 D30
coarse SILT OR CLAYfinemedium
GRAIN SIZE IN MILLIMETERS
3/8 50
8.0ft.
3.0ft.
8.00ft.
3.00ft.
PL
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
GRAIN SIZE USDA ES-8888 UNITED CHRISTIAN CHURCH PROPERTY.GPJ GINT US LAB.GDT 10/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
TP-01, 13.0'10/21/22 8.8 99.2 0.8
TP-07, 7.0'10/21/22 4.7 99.3 0.7
TP-08, 10.5'10/21/22 7.2 99.3 0.7
SUMMARY OF LABORATORY RESULTS
PAGE 1 OF 1
Sample
Location
Date Test
Completed
Water Content
(%)
Ash Content
(%)
Organic Content
(%)
Borehole,
Depth
PROJECT NUMBER ES-8888 PROJECT NAME United Christian Church Property
ESNW ORGANIC CONTENT REPORT ES-8888 UNITED CHRISTIAN CHURCH PROPERTY.GPJ ESNW_DATATEMPLATE.GDT 10/21/22Earth Solutions NW, LLC
15365 N.E. 90th Street, Suite 100
Redmond, Washington 98052
Telephone: 425-449-4704
Fax: 425-449-4711
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Am Test Inc.
13600 NE 126TH PL
Suite C
Kirkland, WA 98034
(425) 885-1664
www.amtestlab.com
Professional
Analytical
Services
ANALYSIS REPORT
EARTH SOLUTIONS NW Date Received: 10/18/22
1805 136TH PL NE Date Reported: 11/ 2/22
BELLEVUE, WA 98005
Attention: KEVEN HOFFMANN
Project Name: UNITED CHRISTIAN CHURCH PROPERTY
Project #: ES-8888
All results reported on an as received basis.
_________________________________________________________________________________________________
AMTEST Identification Number 22-A018146
Client Identification TP-01, 13'
Sampling Date 10/18/22
Conventionals
PARAMETER RESULT UNITS Q D.L. METHOD ANALYST DATE
Cation Exchange Capacity 4.8 meq/100g 0.5
SW-846 9081 CM 11/02/22
_________________________________________________________________________________________________
AMTEST Identification Number 22-A018147
Client Identification TP-07, 7'
Sampling Date 10/18/22
Conventionals
PARAMETER RESULT UNITS Q D.L. METHOD ANALYST DATE
Cation Exchange Capacity 3.0 meq/100g 0.5
SW-846 9081 CM 11/02/22
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
EARTH SOLUTIONS NW
Project Name: UNITED CHRISTIAN CHURCH PROPERTY
AmTest ID: 22-A018148
_________________________________________________________________________________________________
AMTEST Identification Number 22-A018148
Client Identification TP-08,10.5'
Sampling Date 10/18/22
Conventionals
PARAMETER RESULT UNITS Q D.L. METHOD ANALYST DATE
Cation Exchange Capacity 3.4 meq/100g 0.5
SW-846 9081 CM 11/02/22
_________________________________
Kathy Fugiel
President
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Earth Solutions NW, LLC
Report Distribution
ES-8888
EMAIL ONLY Ichijo USA Co., Ltd.
1406 – 140th Place Northeast, Suite 104
Bellevue, Washington 98007
Attention: Mr. Kanon Kupferer
EMAIL ONLY Barghausen Consulting Engineers, Inc.
18215 – 72nd Avenue South
Kent, Washington 98032
Attention: Mr. Barry Talkington, P.E.
Ms. Ivana Halvorsen
Mr. Vicente Varas, P.E.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 7.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
7.0 OTHER PERMITS
All permits required will be provided during final engineering.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 8.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
8.0 ESC ANALYSIS AND DESIGN
An erosion and sediment control plan will be provided during final engineering.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 9.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
9.0 BOND QUANTITIES AND FACILITY SUMMARIES
This section will be completed during final engineering.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
Tab 10.0
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755
22298.001-DRNG
10.0 OPERATIONS AND MAINTENANCE MANUAL
An Operations and Maintenance Manual will be provided during final engineering.
DocuSign Envelope ID: 88ED493A-1813-4C83-AC0E-63CD05982755