Loading...
HomeMy WebLinkAboutMFP23004871.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP23004871 IVR Number: 23004871 Permit Information Permit Name: Comcast Cable Franchise Permit Address/Location:09/22/2023Application Date:3664500338Parcel Number: 15801 SE 128TH ST Permit Type:11/09/2023Issue Date:Franchise Permit Work Class:11/08/2024Expiration Date:Major Utility Job Number: JB0001415603Franchise Type:Cable Description: Comcast proposes to replace equipment at UG and aerial locations. Contacts Name Address PhoneTypeBilling Ashley Kiehn 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Jessamin Santos Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (206) 401-2188Contact Scott Nall SEFNCO Communications Inc. 2904 4th Ave NE Puyallup, WA 98372 B: (877) 385-2903 C: (253) 444-9057 Contractor Business License Number: 41108Construction Contractor: SEFNCCI850QD ELLIFRITS KEVIN 15801 SE 128TH ST RENTON , WA 98059 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date 425-977-9120 SEFNCO Communications, Inc. SEFNCC1850QD BLO29666 Comcast Cable Communications Management, LLC JB0001415603 OSP DE KE26B Rena Watts rena_watts@comcast.com 15801 SE 128TH ST, RENTON, WA 98059 JB0001415603 OSP DE KE26B Comcast proposes to replace equipment at aerial and UG locations. 9/21/2023 MFP23004871 Scott Warlick 11/9/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 3/18/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 3/18/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: ▪ Include map(s) showing the location of the project and work area. ▪ Be legible lettering and clear, contrasting, symbols of viewing or printing. ▪ Must indicate street names, and north arrow and scale. ▪ Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering SEFNCO Communications SEFNCO Permit Coordinator info (253) 999-2271 4610 Tacoma Ave Sumner, WA 98390 9:00am 3:30pm JB0001415603 OSP DE KE26B 15801 SE 128TH ST, RENTON, WA 98059 10/21/2023 11/21/2023 Comcast proposes to replace equipment at aerial and UG locations. MFP23004871 Monday - Friday Scott Warlick CED 11/9/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 3/18/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: • Must have approved Traffic Control Plan (TCP) prior to commencing the work. • Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. • WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • All permit conditions shall be met. NOTES: • Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. • In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 3/18/2021 • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) 9/22/2023 Gayle Berner REVISIONSDATEDESCRIPTIONINITIAL10-27-23R1: revised per commentsHBB17CITY OF RENTON - TCP VICINITY KEY-MAP TTC SET-UPHAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27NO SCALEKEY TAG# TYP./SIM. TTC SET-UP:SITE ADDRESS:1.FOR TTC SET-UP, SEE SHEET-315800 SE 128th ST15822 SE 128th ST2.FOR TTC SET-UP, SEE SHEET-315801 SE 128TH ST15632 SE 128th ST3.FOR TTC SET-UP, SEE SHEET-413006 162nd AVE SE4.FOR TTC SET-UP, SEE SHEET-213005 160th AVE SE5.FOR TTC SET-UP, SEE SHEET-513404 160th AVE SE6831 NE 1st PL13425 160th AVE SE6.FOR TTC SET-UP, SEE SHEET-56792 SE 2nd ST6793 SE 2nd ST16016 SE 136th ST6777 SE 2ND ST7.FOR TTC SET-UP, SEE SHEET-51260 YAKIMA AVE SE286 YAKIMA AVE SE32 ZILLAH PL SE8.FOR TTC SET-UP, SEE SHEET-516007 SE 137th TER16043 SE 137th TER9.FOR TTC SET-UP, SEE SHEET-26822 SE 5th ST10.FOR TTC SET-UP, SEE SHEET-716354 SE 140th ST11.FOR TTC SET-UP, SEE SHEET-216212 SE 138th PL13920 163rd PL SE12.FOR TTC SET-UP, SEE SHEET-213706 161st PL SE13.FOR TTC SET-UP, SEE SHEET-413420 162nd AVE SECITY OF RENTONJURISDICTIONCITY OF RENTONJURISDICTIONCITY OF RENTONJURISDICTION13246789CITY OF RENTONJURISDICTION5160th AVE 156th AVE SE 128th STNE 4th ST156th AVE SE YAKIMA AVE SE 160th AVE SE 162nd AVE SESE 134th ST158th AVE SE 10111213CITY OF RENTONJURISDICTIONFOR TTC SET-UP, SEE SHEET-5SE 1st PLSE 2nd STSE 136th STSE 135th STFOR TTC SET-UP, SEE SHEET-515822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFNOTE:ALL TTC PLANS ARE TYPICAL / SIMILARTO ACTUAL ROAD CONDITIONS, ALL TTCDEVICES TO HAVE MINIMALADJUSTMENTS IN FIELD AS DETERMINEDBY THE FIELD TRAFFIC CONTROLSUPERVISOR TO REFLECT THE NEEDEDTTC FOR WORK CONDITIONS.R1MFP23004871 REVISIONSDATEDESCRIPTIONINITIAL215822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RF 7CIY OF RENTON / TCP-2 TYPICAL / SIMILAR TTC SET-UPADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27LEGEND(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.URBAN STREETS35 / 40 MPH25 / 30 MPH45 / 55 MPH60 / 65 MPH50/65TAPERTANGENT10 TO 20MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3010 TO 2010 TO 20406080SIGN SPACING = X (1)RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS25 MPH OR LESS100'  (2)200'  (2)350'  500' 800'  ONE-LANE, TWO-WAY TRAFFIC CONTROLWITH FLAGGERSW20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)FLAGGING STATIONTEMPORARY SIGN LOCATIONCHANNELIZING DEVICESPROTECTIVE VEHICLEWORKAREA1.2.3.4.50' TO 100'6 DEVICEMIN.50' TO 100'6 DEVICEMIN.50' TO300'NOTESALL SIGNS ARE BLACK ON ORANGE.EXTENDING THE CHANNELIZING DEVICE TAPER ACROSSSHOULDER IS RECOMMENDED.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING ATFLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONSFOR ADDITIONAL DETAILS.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 OEs.HOST VEHICLE WEIGHT! 22,000 OEs.PROTECTIVE VEHICLE (WORK VEHICLE) = R50' TO300'NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000NOTE:WHERE USED, ADJACENT BUSINESSESAND/OR RESIDENT'S WILL BE NOTIFIEDIN WRITING 72 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.SEE VICINITY KEY-MAP TTC SET-UP ONSHEET-1 FOR TTC SET-UP ORIENTATION.AS NOTEDMFP23004871 REVISIONSDATEDESCRIPTIONINITIAL315822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RF 7CIY OF RENTON / TCP-3 TYPICAL / SIMILAR TTC SET-UPADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27NOTE:WHERE USED, ADJACENT BUSINESSESAND/OR RESIDENT'S WILL BE NOTIFIEDIN WRITING 72 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.SEE VICINITY KEY-MAP TTC SET-UP ONSHEET-1 FOR TTC SET-UP ORIENTATION.AS NOTEDMFP23004871 REVISIONSDATEDESCRIPTIONINITIAL415822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RF 7CIY OF RENTON / TCP-4 TYPICAL / SIMILAR TTC SET-UPADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27LEGEND(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.URBAN STREETS35 / 40 MPH25 / 30 MPH45 / 55 MPH60 / 65 MPH50/65TAPERTANGENT10 TO 20MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3010 TO 2010 TO 20406080SIGN SPACING = X (1)RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS25 MPH OR LESS100'  (2)200'  (2)350'  500' 800'  ONE-LANE, TWO-WAY TRAFFIC CONTROL W/ FLAGGERS @ INTERSECTIONINTERSECTING ROADWAYW20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)FLAGGING STATIONTEMPORARY SIGN LOCATIONCHANNELIZING DEVICESPROTECTIVE VEHICLEWORKAREA1.2.3.4.50' TO 100'6 DEVICEMIN.50' TO 100'6 DEVICEMIN.MIN. 50'NOTESALL SIGNS ARE BLACK ON ORANGE.EXTENDING THE CHANNELIZING DEVICE TAPER ACROSSSHOULDER IS RECOMMENDED.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING ATFLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONSFOR ADDITIONAL DETAILS.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 OEs.HOST VEHICLE WEIGHT! 22,000 OEs.PROTECTIVE VEHICLE (WORK VEHICLE) = RMIN. 50'NOTE:WHERE USED, ADJACENT BUSINESSESAND/OR RESIDENT'S WILL BE NOTIFIEDIN WRITING 72 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.SEE VICINITY KEY-MAP TTC SET-UP ONSHEET-1 FOR TTC SET-UP ORIENTATION.AS NOTEDMFP23004871 515822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RF 7TYPICAL / SIMILAR TTC SET-UPADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27NOTE:WHERE USED, ADJACENT BUSINESSESAND/OR RESIDENT'S WILL BE NOTIFIEDIN WRITING 72 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.SEE VICINITY KEY-MAP TTC SET-UP ONSHEET-1 FOR TTC SET-UP ORIENTATION.LEGEND(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.URBAN STREETS35 / 40 MPH25 / 30 MPH45 / 55 MPH60 / 65 MPH50/65TAPERTANGENT10 TO 20MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3010 TO 2010 TO 20406080SIGN SPACING = X (1)RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS25 MPH OR LESS100'  (2)200'  (2)350'  500' 800'  ONE-LANE, TWO-WAY TRAFFIC CONTROLWITH FLAGGERS @ INTERSECTIONINTERSECTING ROADWAYW20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)FLAGGING STATIONTEMPORARY SIGN LOCATIONCHANNELIZING DEVICESPROTECTIVE VEHICLEWORKAREA1.2.3.4.50' TO 100'6 DEVICEMIN.50' TO 100'6 DEVICEMIN.50' TO300'NOTESALL SIGNS ARE BLACK ON ORANGE.EXTENDING THE CHANNELIZING DEVICE TAPER ACROSSSHOULDER IS RECOMMENDED.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING ATFLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONSFOR ADDITIONAL DETAILS.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 OEs.HOST VEHICLE WEIGHT! 22,000 OEs.PROTECTIVE VEHICLE (WORK VEHICLE) = RCIY OF RENTON / TCP-5AS NOTEDR1ADDED TTC SHEETREVISIONSDATEDESCRIPTIONINITIAL10-27-23R1: revised per commentsHBBMFP23004871 615822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RF 7TYPICAL / SIMILAR TTC SET-UPADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27NOTE:WHERE USED, ADJACENT BUSINESSESAND/OR RESIDENT'S WILL BE NOTIFIEDIN WRITING 72 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.SEE VICINITY KEY-MAP TTC SET-UP ONSHEET-1 FOR TTC SET-UP ORIENTATION.CIY OF RENTON / TCP-61PCMS RURAL ROADS & URBAN ARTERIALS35 / 40 MPH350'  45 / 55 MPHRURAL ROADS500' 25 / 30 MPH200'  (2)URBAN STREETS25 MPH OR LESS100'  (2) PCMS10550605660105125150205270165225295180245320540115-----7206607808402530354045505510'6040406570SHOULDERWIDTH(feet)160200220170190240150190130170120150406060909090WORK AREA260 / 65 MPHRURAL HIGHWAYSFREEWAYS & EXPRESSWAYS2530354050551260116570LANEWIDTH(feet)8'55 / 70 MPH800' 1 MILEAHEADLEGENDTEMPORARY SIGN LOCATIONTRAFFIC SAFETY DRUMSEQUENTIAL ARROW SIGNTRANSPORTABLE ATTENUATORPORTABLE CHANGEABLE MESSAGE SIGNMPH50/7035/4525/30TAPERTANGENT403020806040RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.50055060049545045USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'.SINGLE-LANE CLOSURE FOR MULTI-LANE ROADWAYSRIGHTLANECLOSUREFIELD LOCATE 1 MILE  INADVANCE OF LANE CLOSURE SIGNING.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 OEs.HOST VEHICLE WEIGHT! 22,000 OEs.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.EXTEND DEVICE TAPER AT L/3 ACROSS SHOULDER.DEVICES SHALL NOT ENCROACH INTO THE ADJACENT LANE.USE TRANSVERSE DEVICES IN CLOSED LANE EVERY 1000' (FT)(RECOMMENDED).DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE20' (FT).ALL SIGNS ARE BLACK ON ORANGE.1.2.3.4.5.6.NOTES2' MIN.SEENOTE 4AS NOTEDR1ADDED TTC SHEETREVISIONSDATEDESCRIPTIONINITIAL10-27-23R1: revised per commentsHBBMFP23004871 715822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RF 7TYPICAL / SIMILAR TTC SET-UPADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27NOTE:WHERE USED, ADJACENT BUSINESSESAND/OR RESIDENT'S WILL BE NOTIFIEDIN WRITING 72 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.SEE VICINITY KEY-MAP TTC SET-UP ONSHEET-1 FOR TTC SET-UP ORIENTATION.CIY OF RENTON / TCP-7AS NOTEDRURAL ROADS & URBAN ARTERIALS35 / 40 MPH350'  45 / 55 MPHRURAL ROADS500' 25 / 30 MPH200'  (2)URBAN STREETS25 MPH OR LESS100'  (2) 10550605660105125150205270165225295180245320540115-----7206607808402530354045505510'6040406570SHOULDERWIDTH(feet)16020022017019024015019013017012015040606090909060 / 65 MPHRURAL HIGHWAYSFREEWAYS & EXPRESSWAYS2530354050551260116570LANEWIDTH(feet)8'55 / 70 MPH800' LEGENDTEMPORARY SIGN LOCATIONTRAFFIC SAFETY DRUMTRANSPORTABLE ATTENUATORMPH50/7035/4525/30TAPERTANGENT403020806040RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.50055060049545045USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'.SHOULDER WORK/SHOULDER CLOSEDSPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 OEs.HOST VEHICLE WEIGHT! 22,000 OEs.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.EXTEND DEVICE TAPER AT L/3 ACROSS SHOULDER.DEVICES SHALL NOT ENCROACH INTO THE ADJACENT LANE.USE TRANSVERSE DEVICES IN CLOSED LANE EVERY 1000' (FT)(RECOMMENDED).DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE20' (FT).ALL SIGNS ARE BLACK ON ORANGE.1.2.3.4.5.6.NOTESWORKAREASHOULDERWORKSHOULDERWORKW21-5W21-5RIGHTSHOULDERCLOSEDRIGHTSHOULDERCLOSEDW21-5W21-515'±NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000R1ADDED TTC SHEETREVISIONSDATEDESCRIPTIONINITIAL10-27-23R1: revised per commentsHBBMFP23004871 SEFNCOCOMMUNICATIONSCOMCASTT2A - WAISD01W00 1x2 - WAISD01V00 2x4 (KE26B 3x4) - RF15801 SE 128TH ST, RENTON, WA 98059JB0001415603PROPOSED SPLICE LOCATIONS - FOR FIBER INSTALLATIONMFP23004871 CONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5 - 17SITE-PLANDESCRIPTION OF WORKTOTAL(16) AERIAL SPLICE LOCATIONS - SEE VICINITY KEY- MAPFOR APPROXIMATE LOCATIONS0LF(8) GROUND SPLICE LOCATIONS - SEE VICINITY KEY-MAPFOR APPROXIMATE LOCATIONSTOTAL:0LFVICINITY KEY-MAPSEFNCO - PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE:253-999-2271EMAIL: ASKIEHN@SEFNCO.COM172R.O.W. PERMIT - DESIGNNTSREVISIONSDATEDESCRIPTIONINITIALCOMCAST - OPESEFNCO - OPE15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFJESSAMIN SANTOS410 VALLEY AVEPUYALLUP, WA 98371PHONE: (206) 401-2188Jessami_Santos@cable.comcast.comSTACEY PENNEWELL4610 TACOMA AVE.SUMNER, WA 98390253-457-0628spennewell@sefnco.com KEY TAG# SPLICE LOCATION SHEET #:SITE ADDRESS:1.SPLICE LOCATION, SEE SHEET-515800 SE 128th ST15822 SE 128th ST2.SPLICE LOCATION, SEE SHEET-615801 SE 128TH ST15632 SE 128th ST3.SPLICE LOCATION, SEE SHEET-713006 162nd AVE SE4.SPLICE LOCATION, SEE SHEET-813005 160th AVE SE5.SPLICE LOCATION, SEE SHEET-913404 160th AVE SE6831 NE 1st PL13425 160th AVE SE6.SPLICE LOCATION, SEE SHEET-106792 SE 2nd ST6777 SE 2nd ST6793 SE 2nd ST16016 SE 136th ST7.SPLICE LOCATION, SEE SHEET-111260 YAKIMA AVE SE286 YAKIMA AVE SE32 ZILLAH PL SE8.SPLICE LOCATION, SEE SHEET-1216007 SE 137th TER16043 SE 137th TER9.SPLICE LOCATION, SEE SHEET-136822 SE 5th ST10.SPLICE LOCATION, SEE SHEET-1416354 SE 140th ST11.SPLICE LOCATION, SEE SHEET-1516212 SE 138th PL13920 163rd PL SE12.SPLICE LOCATION, SEE SHEET-1613706 161st PL SE13.SPLICE LOCATION, SEE SHEET-1713420 162nd AVE SECITY OF RENTONJURISDICTIONCITY OF RENTONJURISDICTIONCITY OF RENTONJURISDICTION13246789CITY OF RENTONJURISDICTION5160th AVE 156th AVE SE 128th STNE 4th ST156th AVE SE YAKIMA AVE SE 160th AVE SE 162nd AVE SE SE 130th ST158th AVE SE 10111213MFP23004871 15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFGENERAL NOTES GENERAL NOTESTHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.173R.O.W. PERMIT - DESIGNN/AREVISIONSDATEDESCRIPTIONINITIALMFP23004871 15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFLEGEND 174R.O.W. PERMIT - DESIGN LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERELECTRICALRAILROADRIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILFENCESDSDWWSSSSGGEETTR/WLIPD/LEOPFOCRWRWTRENCHDIRECT BOREDBDBPROPOSED AERIAL OVERLASH PROPOSEDBASE LAYERSEXISTING UTILITIESEXISTING UTILITIES SYMBOLS POWER HANDHOLEPOWER MANHOLEPOWER CABINETSTREET LIGHT HANDHOLEPOWER SIDEWALK GUY SEWER CLEANOUTSTORM CATCH BASIN STORM MANHOLEWATER VALVEWATER METERTELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALPOWER VAULTSTREET LIGHT POLETRAFFIC SIGNAL VAULTTRAFFIC SIGNAL HANDHOLESIGN POSTPARKING METERCATV MANHOLECATV HANDHOLEPOWER PEDESTALGAS METERTEST VALVETRAFFIC LOOP DETECTORCATV PEDESTALBOLLARDWATER MANHOLETRAFFIC SIGNAL POLEPOWER GUYTRAFFIC DETECTORADA RAMPPEDESTAL(UNKNOWN UTILITY)MANHOLECULVERTFIRE HYDRANTGAS VALVE(UNKNOWN UTILITY)POWER ANCHORPOWER POLESEWER MANHOLETELECOM POLETELECOM PEDESTALPROPOSED VAULTPROPOSED PEDESTALPROPOSED MANHOLEPROPOSED SIDEWALK ANCHOR & GUYPROPOSED SYMBOLS ADA RAMP COMPLIANCEPEXISTING COMCAST VAULTEXISTING COMCAST SPLICEEXISTING COMCAST ANCHOREXISTING COMCAST GUYEXISTING COMCAST MANHOLEEXISTING COMCAST SIDEWALK ANCHOR & GUYP=VLP=GAS TEST POINTGAS MANHOLEPOWER UNKNOWN STORM CLEANOUTSTORM DRAIN VALVESTORM DRAIN UNKNOWN WATER UNKNOWNWATER WELLWATER PUMPWATER VAULTWATER RESERVOIRPPPPPP?PSLSLTSTSTSTSTSTSCCCTTTP=??TTSSSCSDD?DCDWWWWWVW?WELLPUMPGGGTLTLSEWER CATCH BASIN SSWATER SAMPLING STATIONOTHER UNKNOWNSTORM ACCESS POINTSEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?SUB STATIONTRANSIT STOPSTORM DRAIN VAULT SDTREE PROPOSED RISEREXISTING COMCAST SYMBOLS BORE PITPROOF/PULLEXISTING COMCAST PEDPEXISTING COMCAST POLE W/ NEW RISERFMHMHBUILDING OUTLINEFLFOG LINETRENCHPSPLICE CASEPROPOSED AERIAL STORAGEEXISTING AERIAL STORAGE0'0'POTHOLESWSIDEWALK LINEPROPOSED AERIAL STRAND N/AREVISIONSDATEDESCRIPTIONINITIALMFP23004871 SITE ADDRESS:15822 SE 128TH STCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONSE 128th ST160th AVE SE 160th AVE SE SE 127th PLSITE ADDRESS:15800 SE 128TH ST15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-1 15822 SE 128TH ST51 17Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.REVISIONSDATEDESCRIPTIONINITIALCITY OF RENTON R.O.W. PERMIT - DESIGN1 MFP23004871 SE 128th STSITE ADDRESS:15632 SE 128TH ST158th AVE SE SITEADDRESS:15801 SE128TH ST15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-2 13005 160TH AVE SE6 17Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NREVISIONSDATEDESCRIPTIONINITIAL1SCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.CITY OF RENTON R.O.W. PERMIT - DESIGN1 MFP23004871 SITE ADDRESS:13006 162ND AVE SESE 130th ST162nd AVE SE162nd AVE SE S E 1 3 0 t h S T CITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTION15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-3 15822 SE 128TH ST71REVISIONSDATEDESCRIPTION INITIAL17Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.CITY OF RENTON R.O.W. PERMIT - DESIGN MFP23004871 SITE ADDRESS:13005 160TH AVE SE160th AVE SECITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONSE 130th ST15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-4 13005 160TH AVE SE8 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.1MFP23004871 SITE ADDRESS:6831 NE 1ST PL160th AVE SE SE 134th STSITE ADDRESS:13404 160TH AVE SECITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONSITE ADDRESS:13425 160TH AVE SE15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-5 13404 160th AVE SE 6831 NE 1st PL 13425 160TH AVE SE9 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.111MFP23004871 SITE ADDRESS:6793 SE 2ND STSITE ADDRESS:6777 SE 2ND STSITE ADDRESS:6792 SE 2ND STSITE ADDRESS:16016 SE 136th STCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTION160th AVE SE SE 135th STSE 2nd STSE 136th STCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTION15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-6 6792 SE 2nd ST / 6777 SE 2ND ST 6793 SE 2nd ST / 16016 SE 136th ST10 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.APPROXIMATE GROUND SPLICE LOCATION.11122MFP23004871 SITE ADDRESS:302 ZILLAH PL SESITE ADDRESS:286 YAKIMA AVE SESITE ADDRESS:260 YAKIMA AVE SEYAKIMA PL SE SE 3rd STZILLAH PL SEYAKIMA PL SE 15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-7 1260 YAKIMA AVE SE 286 YAKIMA AVE SE 302 ZILLAH PL SE11 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.111MFP23004871 SITE ADDRESS:16043 SE137TH TERSITE ADDRESS:16007 SE137TH TER160th AVE SESE 137th TERSE 137th TER161sr PL SE 15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-8 16007 SE 137th TER 16043 SE 137th TER12 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.APPROXIMATE GROUND SPLICE LOCATION.212MFP23004871 SITE ADDRESS:6822 SE 5TH ST160th AVE SE SE 5th ST15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-9 6822 SE 5th ST13 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE GROUND SPLICE LOCATION.1MFP23004871 SE 140th ST163rd PL SE SITE ADDRESS:16354 SE140TH ST164th AVE SE SE 139th STCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTION15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-10 16354 SE 140th ST14 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE GROUND SPLICE LOCATION.1MFP23004871 162nd AVE SE SE 138th PLSE 139th CT163rd PL SE SITEADDRESS:13920163RD PL SESITE ADDRESS:16212 SE 138TH PL15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-11 16212 SE 138th PL 13920 163rd PL SE15 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE GROUND SPLICE LOCATION.11MFP23004871 SITE ADDRESS:13706 161ST PL SESE 137th TER161sr PL SE162nd AVE SE 15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-12 13706 161st PL SE16 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.1MFP23004871 SITE ADDRESS:16016 SE 136TH STSITE ADDRESS:13420 162ND AVE SESITE ADDRESS:13414 162ND AVE SECITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONCITY OF RENTONJURISDICTIONKING COUNTYJURISDICTIONSE 135th ST162nd AVE SE 163rd AVE SE SITE ADDRESS:13411 163RD AVE SE15822 SE 128TH ST, RENTON, WA 98059 JB0001415603 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB9/19/2023T2A - WAISD01W00 1X2 - WAISD01V00 2X4 (KE26B 3X4) - RFSITE PLAN-13 13414 162nd AVE SE / 13420 162nd AVE SE 13411 163rd AVE SE / 16016 SE 136th ST17 CITY OF RENTON R.O.W. PERMIT - DESIGNREVISIONSDATEDESCRIPTIONINITIAL17 Know what'sbelow.CallR 81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.1MFP23004871