Loading...
HomeMy WebLinkAboutCOR FIELD NOTE RECORDS - C19004381 - 2800 Unit Lot SubdivisionDEVELOPMENT ENGINEERING jchavez 12/06/2019 WASTEWATER UTILITY Ann Fowler 12/06/2019 SURFACE WATER UTILITY jfarah 12/06/2019 WATER UTILITY agafour 12/06/2019 REGIONAL FIRE AUTHORITY cthomas 12/09/2019 APPROVED DEVELOPMENT ENGINEERING jchavez 12/06/2019 W-408201 S-408201 DEVELOPMENT ENGINEERING jchavez 12/06/2019 DEVELOPMENT ENGINEERING jchavez 12/06/2019 Condition of Approval: this triangle piece shall be landscaping, not hardscape. Condition of Approval: this triangle piece shall be landscaping, not hardscape. Condition of Approval: follow trench restoration details and coordinate with inspector on overlay extent. Condition of Approval: extend saw cut and grind/overlay limits. follow trench restoration details and coordinate with inspector on overlay extent. DEVELOPMENT ENGINEERING jchavez 12/06/2019 SURFACE WATER UTILITY jfarah 12/06/2019 Condition of Approval: Use c900 pvc or ductile iron pipe in-lieu of minimum horizontal clearance between storm and water main. Condition of Approval: Use c900 pvc or ductile iron pipe in-lieu of minimum horizontal clearance between storm and water main. DEVELOPMENT ENGINEERING jchavez 12/06/2019 SURFACE WATER UTILITY jfarah 12/06/2019 HARRINGTON AVE N.E.N.E. 13TH ST. N.E. 12TH ST.UNIT LOT1234567891011Know what'sCallbelow.before you dig.REastern Washington Division407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433Western Washington Division165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250ncompassENGINEERING & SURVEYINGEIN COMPLIANCE WITH CITY OF RENTON STANDARDSS.W. 1/4 OF S.W. 1/4 OF SECTION 04, T. 23 N., R. 05 E., W.MCITY OF RENTON, STATE OF WASHINGTONNORTHEXISTING STRUCTURES:CONSTRUCTION NOTES:VERTICAL BEND ENLARGEMENTMINIMUM CLEARANCE DETAILWITH CONCRETE BLOCKINGWITH CONCRETE BLOCKINGWITH CONCRETE BLOCKINGWATER UTILITYagafour 12/15/20213.0 ft 3.0 ft4.5 ft2.0 ft2.0 ft2.0 ft//////////////////////////////////////////////////////////////////////////////////////////EXISTINGDUCT BANK8" SS13 FT DEEP6" MIN SEPARATION BETWEENBOTTOM OF DUCT BANK TO TOP OFWATER LINETEMPORARY END CAP AND TEMPBLOCKING8"-45° BEND (MJxMJ) WITHMEGALUG(TYPICAL ALL BENDS)CITY FORCES WILL PERFORM FINAL CONNECTIONWITH CUT-IN TEE, VALVES AND CONNECTIONWITH 8" SLEEVE3.0 ft 2-3/4' SHACKLE RODS (TYPICAL)VERTICAL BLOCKING8" WATER FROM SITEDUCT BANK BEHIND CURB LINECONTRACTOR SHALL INSTALL AND TEST ALL NEW WATER MAIN AND FITTINGS UP TO 5 FEETFROM EXISTNG 8" WATER MAIN IN NE 12TH ST.CITY FORCES WILL PERFORM FINAL CONNECTION TO EXISTING 8" WATER IN NE12TH WITH THEVALVES CUT-IN AND CONNECTION WITH 8" SLEEVE8"-45° BEND (MJxMJ) WITHMEGALUG(TYPICAL ALL BENDS)SKETCH PREPARED BY ABDOUL GAFOURCITY OF RENTON WATER UTILITY MANAGER12/16/21EXISTING CURB AND GUTTER DEVELOPMENT ENGINEERING jchavez 12/06/2019 SURFACE WATER UTILITY jfarah 12/06/2019 DEVELOPMENT ENGINEERING jchavez 12/06/2019 DEVELOPMENT ENGINEERING jchavez 12/06/2019 WATER UTILITY agafour 12/06/2019 W-408203 DEVELOPMENT ENGINEERING jchavez 12/06/2019 WASTEWATER UTILITY Ann Fowler 12/06/2019 S-408203 APPROVED 12/09/2019 jding PLANNING DIVISION